ANTRIEBSTECHNIK
GB4001 EA4001
Purpose: Encoder connection TTL or HTL and buffered Purpose: Encoder connection TTL or HTL (can be switched),
encoder output TTL or HTL (can be switched), one binary 5 additional binary inputs, 1 binary output, external 24 V supply
output, external 24 V supply for encoder and inverter for encoder and inverter
Application: High-quality encoder connection, synchronous Application: Positioning, synchronous running
running
Terminals: Plug connectors X20 and X21 on top of device Terminals: Plug connectors X20 and X21 on top of device
Caution:
Fixed
encoder
power
supply
UB = 18 V
* Bin. output
BA2 is EA-4000-compatible
contained in
basic device
as
relay2/BA2.
Plug connector X21: Buffered encoder output for GB4001 Plug connector X21: I/O expansion for EA4001
1: Reference ground, connected internally with X20.7 + X20.9 A: BA4, Binary output, for data see BA1 (left)
2: BA1, binary output Techical data, BA1: B: BA3, Binary output
3: / C Inverted encoder track C 1: 0 V Ref. ground
4: C Encoder track C (zero track) L level 1 V at 20 mA, 2: BA1, Bin. output
5: / B Inverted encoder track B Ri = 10 3: BE10, Bin. input
6: B Encoder track B H level = Uext 4 V at 4: BE9, Bin. input
7: / A Inverted encoder track A 20 mA, Ri = 120 5: BE8, Bin. input
8: A Encoder track A 6: BE7, Bin. input 0 V on X21.1, X20.7 and X20.9 are
connected but galvanically isolated
7: BE6, Bin. input from X1.8 device ground!
Encoder output: Imax = 20 mA. Resolution can be set in 5
stages (1/1 to 1/16) with parameter H21. Technical data - binary inputs:
Important: The negated tracks must be connected. All three tracks are monitored for wire break (fault 3 :n- eed c ). This
does not apply to the evaluation of the stepper motor signals. The signal rise time from 10% to 90% of the level must be 2
µsec. The type of option board is automatically recognized and indicated in parameter E54. The external 24 V voltage supply
(terminals 9 and 10) must be connected and must already be present when the inverter is turned on.
H20=2:encoder in specifies the X20 function as input for incremental encoder. The motor encoder must be set to B26=1:X20
with vector control via X20. The signals "direction" and "sign" can be used with H20=3:Stepmotor In as reference value for the
electronic gearbox (activation with parameter G20).
Interference immunity: EN 61000-4-4. All cables shielded. Cables: Use original STÖBER cables!