You are on page 1of 1

60PK750 POWER SUPPLY START UP SEQUENCE

In Stand-By Primary side is 158V


In Run (Relay On) Primary side is 337.5V 7
M5V
POWER SUPPLY 7
Reg
AC In (SMPS)
10
+5V Vs
1 Stand
Reg 10
By 5V Reg Regulator
Vs
STBY RUN 17V
3.46V 5V Reg 9 Va Va
5 Reg 10 7 10 7
9

AC Stand By Error Det. 5V 17V


Det. 5V Va Vs Vs
M5V M5V
9 10 7 10 7
6 2 6 6 6 M5V
RL On On Y-SUS Z-SUS CONTROL
Not Va 5VFG 18V 18V / M5V 3.3V
Used 5 7
9 8 8
8
8
8
5V 18V / M5V
Error Det. 7V 17V At point 3
Floating
Via Audio TV is in
AC Det. Gnd Y DRIVE Upper
IC404 IC300 Stand-By
If missing, state. It is
set turns Energy Star Y DRIVE Lower
off within +5V HDMI Compliant.
10 sec. EDID Tuner Less than 1 8 3.3V
And other 5V Watt Va Va
circuits Via X PWB X PWB X PWB
IC405 9
3.3VST 5 MAIN Left Center Right
3.3V Reg 9 9
IC400 2 Error Relay M5V On Board STBY 5V
Det. On 7
Reset 3 2 Soft
Microprocessor Power On Front IR
IC707
IC701
Touch
4 4 Board
Key Pad
Remote Power Key
Power Key

You might also like