Professional Documents
Culture Documents
Snubber Design (RC Snubber)
Snubber Design (RC Snubber)
T1 D202 L201
EER3016 MBRF10100
12V, 2.5A
1 +10 C201 C202
1000uF 1000uF
C104 25V 25V
R103
10nF 2 -8
Ω
56kΩ
R102 1kV
2W D101
C103 Ω
30kΩ
100uF UF 4007
3
400V
BD101 2 R105
2KBP06M3N257 Ω
40kΩ IC1
FSDM07652R
6
1 3 Vstr 1
Drain
5 D201
NC L202
MBRF1045
Vcc 3
4 5V, 2A
4 Vfb 4 7
GND C105 D102 R104 C203 C204
C102 C106
2 ZD101 22uF TVR10G Ω
5Ω 1000uF 1000uF
220nF 47nF
22V 50V 10V 10V
275VAC 50V
6
5
C301
LF101 4.7nF
23mH
R201
Ω
1kΩ
R101 R204
Ω
560kΩ Ω
5.6kΩ
1W R202
R203 C205
Ω
1.2kΩ
Ω
1.2kΩ 47nF
IC301
H11A817A
F1 IC201
C101
RT1 FUSE KA431
220nF R205
5D-9 250V
275VAC Ω
5.6kΩ
2A
4. Snubber design (RC snubber)
Llk
Llk Llk
3Cout
Cout Z Cout
(1) Measure the original resonance period (Tr) (2) Find a capacitor value that doubles the
of the diode voltage waveforms. resonance period when connected in
parallel with the diode.
Csn
D202
MBRF10100
10
C201
1000uF
25V
8
680pF 30
(3) Calculate the snubber resistor with the following equation.
D202
MBRF10100
10
C201
1000uF
25V
8
4. Snubber design (RCD snubber)
Ω, fs=66kHz)
Experimental results (Csn=2.2nF, Rsn=56kΩ
Design Procedure
Measure the leakage inductance : measure the primary side
inductance with all other windings shorted
– LCR meter is not always correct (Normally 50% error) especially the
leakage inductance is small
Determine the snubber capacitor voltage (Vsn) considering voltage
margin of BVdss
Calculate the snubber resistor using 2V (V − V )
Rsn = sn sn 2RO
Llk f s I pk
Determine the snubber capacitor considering the snubber capacitor
voltage ripple (1~10nF)
If the measured drain voltage is different from the designed value,
leakage inductance should be calibrated using
Ω, Csn=2.2nF
Rsn=56kΩ
Vsn=520-370=150V
Ω, Csn=2.2nF
Rsn=96kΩ
Vsn=543-370=173V
The drain voltage is lower than the designed value by 9V due to the
stray resistance (Measured:543V, Designed:552)