You are on page 1of 1

ATA 26 FDCU test Page 93/ 95

2 amber lights and 1 BITE switch with 3 positions permit the testing functions of the FDCU.
BITE instructions are displayed on the front face of the FDCU.
When a loop failure is sensed, the BITE switch permits the failure on the control unit or sensing elements to be identified.
Note: BITE indicators are taken into account only when flight compartment confirms a failure condition.
3 positions are available with the BITE switch.
Loop A is fault on overhead panel. Please set BITE switch to POS 1 to test LOOP A.
3 positions are available with the BITE switch.
LOOP A light does not illuminate. FDCU must not be replaced. Loop A short circuit is detected.
Note: if LOOP A light illuminates:
FDCU must be replaced.
Loop A short circuit is not detected.
Please set BITE switch to POS 3 to confirm loop fault diagnosis.
3 positions are available with the BITE switch.
LOOP A light illuminates. FDCU must not be replaced. Loop A short circuit is detected.
Note: if LOOP A light does not illuminate:
FDCU must be replaced.
Loop A short circuit is not detected.