S De-energised closed
S Guided valve spool and poppet
S Available in two mounting versions
S With or without manual override
S Hand lever can be fitted on solenoid
S All external parts zinc plated, chromited (CrVI-free)
S High pressure wet-armature solenoids
S The slip-on coil can be rotated, and it can be
replaced without opening the hydraulic envelope
S Can be fitted in a line-mounting body
1 Description
The W1C… series of 2/2 solenoid operated directional seat applications where leak-tight shut-off functions are crucially
valves are size 6, direct acting, pressure balanced, push-in important. Examples are where loads, tensions, or clam-
cartridges. In the normal condition (de-energised closed), ping forces must be held without leakage. All external parts
flow is shut off without leakage. The core element operates of the cartridge are zinc plated and chromited (CrVI-free)
on the tried and tested principle of the guided poppet, and and are thus suitable for use in the harshest operating envi-
the guide spool has a seal. Two different mounting versions ronments. The slip-on coils can be replaced without ope-
are available, which allows the designer to choose the inser- ning the hydraulic envelope and can be positioned at any
tion depth (flange 10.1 mm or 18 mm). These cartridge seat angle through 360°. If you intend to manufacture your own
valves are also available with or without manual override, cavities or are designing a line-mounting installation, please
and with the option of an additional hand lever. These val- refer to the section “Related data sheets”.
ves are predominantly used in certain mobile and industrial
2 Symbol
1 1 Important
A “de-energised open” function can be created by
using the 3/2 solenoid cartridge valve and the
2 2 GADA line-mounting body. In this case, ports 2
and 3 are used. Port 1 is plugged.
3 Technical data
Reference: 400-P-110110-E-00/04.07
Classification: 430.300.-.305.310.300 (W-2.11) 1/5
Hydraulic characteristics Description, value, unit
Maximum operating pressure …315 bar
Maximum flow rate 20 l/min
Flow direction 1 → 2 / 2 → 1, see symbols
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please consult BUCHER
Hydraulic fluid temperature range -25 °C … +80 °C
Viscosity range 10…500 mm2/s (cSt), recommended 15...250 mm2/s (cSt)
Minimum fluid cleanliness class 20/18/15
Cleanliness class to ISO 4406 : 1999
4 Performance graphs
measured with oil viscosity 33 mm2/s (cSt), coil at steady-state temperature and 10 % undervoltage
300
8
250
200 6
150
4
100
2
50
0 0
0 5 10 15 20 Q [l/min] 0 5 10 15 20 Q [l/min]
400-P-110110-E-00/04.07 2/5
Series W1C…
5 Dimensions & sectional view
5.1 Shallow insertion model 5.2 Deep insertion model
(shown here without manual override)
Ma = 2.7 ± 0.3 [Nm]
80.7
58.2
47.5
1)
2.1
2.6
Ø 45
59.9
93.3
85.5
118
4
18
10.1
4
Ma = 5.5 ± 0.25 [Nm]
M5 3 3)
24.7
6.1
3 2)
2
40 1
400-P-110110-E-00/04.07 3/5
Series W1C…
6 Installation information
Attention
Only qualified personnel with mechanical skills Important
may carry out any maintenance work. Generally, These size 6, 2/2 solenoid operated directional
the only work that should ever be undertaken is to cartridges can also be fitted in the AC or AD ca-
check, and possibly replace, the seals. When vities, and in such cases port 3 then has the same
changing seals, oil or grease the new seals tho- function as port 2.
roughly before fitting them.
Important
When fitting the cartridges, use the specified
tightening torque for the mounting screws. No ad-
justments are necessary, since the cartridges are
set in the factory.
126.9
4
Ø 23
15˚
50.9
4)
111.9
155
Ø 45
4) Operated position
400-P-110110-E-00/04.07 4/5
Series W1C…
8 Ordering code
Ex. W1 C B A _ 24 VDC + HHB _
info.ch@bucherhydraulics.com www.bucherhydraulics.com
E 2007 by Bucher Hydraulics AG, CH-3714 Frutigen
All rights reserved.
Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
400-P-110110-E-00/04.07 5/5
Series W1C…