BENCHMARK
GP marke DETAL Xmarle™ DETAL an et a
ormark” Vela Amark™ UElAIL (BOX CONNECTION LENGTH)
ii = 0.063 ——] See BENCHVARK —
See Note 2 1.500 Min
! PRIMARY MAKE-UP SHOULDER —=| Pit Free Zone
(SEAL) See Note 6
Bevel dia, “>
b -- La,
_.| L- 0.125 T NN LLY
See Note 2 m7 | — Zt
3219 ‘Otte ie Nole"S |
Bevel Dia SECONDARY MAKE-UP SHOULDER
3234 Nin 2.862 40.031 (MECHANICAL STOP) \ DANY Re
NOTES: Outside Oia. Core Dia Cyfndrica Di
1. Lead tolerance: See Note 4
«a, For 2 inches +0.006 inch,
b. Recut threads if stretch exceeds 0.006 inch in 2 inches.
2. Either benchmark type is applicable but not both.
a. GPmark: 0.125 is new condition, shall be 0.062 min. after refacing,
b. Xmark: 0.063 is new condition. After refacing a visible step
on the benchmark shall remain on the primary shoulder.
Rethreading is required if there is no visible benchmark.
3. At Outside Diameter less than 3.281, Bevel Diameter is void
Thread taper 0.750” per ft
35 Threads per inch
=F
0.188 wl
and 1/32" x 45° becomes effective. 1 0! wok ie bet
4. Minimum 0.0. based on wall thickness at counterbore. Larger 0. sete 3
may be required for specific grade performance ee Note
5, Surface finish requirement only applies during refacing operation
6. Area of the connection where pitting is not permitted in the thread roots
ag E ‘ oweasions wreout |
Kesgredt SSS qs | Grant Prideco, jiitners we tog! XTF™ 26 / uXT™ 26 Box
by CI REFERENCE | FIELD INSPECTION DIMENSIONS:
ay _ 3 INFORMATION ONLY
S| Per ew [4/28/2000 bce $F
Oe : ea 71786 [ran 01