You are on page 1of 2
LineTroll 110Epr Fault Passage Indicator for overhead lines (6-69 [kv]) Product Ne: 04-1200-05 ‘Achister of red LED's for permanent faut and one green LED for transiont faut. {addition a single LED wil give indication on low battery status. High vic Features: ‘= Programmable operating parameters, High visbty (> 12 umens) 950 degrees. ‘= Usable on a Medium Voltage dlemtution networks 6-69 (KV. ‘= Usable on mut circu systems. ' Vortage or current as stat erteria (programmable) = innish biking, ‘= Dual inieation, permanent and transient faults. ‘+ Resistant tough weather condions. ‘= Battery capacity monitoring Functional description: LineTretl 110 continuously moritors the line voltage and phase curent the sources of information it needs to operate, The units fully seltcontained, ro extemal transformers or connections is required, During normal line conditions, LineTrol NOE. remains estingushed The indicator is looking for specific sequence of line conditions to happen before itstarts ashing. The general sequence is as follows: ‘A The ine should be energised (votage or current present) for a minimum ot § seconds, BB DVDE: The line current should increase rapidly by the amount of 3 user set valve (the step level). Treshold, the line current ‘exceeding a present curent lev. . The lie should be de-energised,(Votage or curent not present) The user may progrem the erteria for operation to suit his local requirements by manipulating @ bank of micto-switshes inside the indicator Note: Voltage or current as start and stop criteria is user programmable. Application: ‘Short cirouit and Earth faut incation fr overhead tines. ‘System voltage: 6-69 [KV] medium voage networks. Grounding eystemt eolated resistor and solaly grounded. Fault detection: ‘Sensitty DVDR SO(H2: 6, 12, 25, 6 oF 1208] * Sensitivity Treshold, SOQH2} 250, $09, 750 or 1000 [A]* Duration: > 60 fos) (20fms] on quest) Irnush blocking 5 see, (CB-Tipping: Waitin 5 see; Reset: Automatic: Re-eneraised tine (Voltage or curent, programmable) Timer 2, 8, 12 0°24 hours * ‘Monual: By magnet / Mounting resettool Note: Alresholds, timers ste ae selectable and programmatls by dip-switches. Indication: Permanent fats: 4 red and 1 green LED, Transient fauts:1 green LED. Intensiy:> 12 lumens for permanent faut. isa: Day. 250m) Night 2 thd Direction: 350 degrees. Flashing frequency: F= 0.2 [HS after 12 h reduced to f20.1 [He ‘Low battery nication: 1 LED (0.1 (Ha). Power Supply: 1 Lithium cet: Dsize total capacty 16.5 [Ah [Battery change: every 1500 flash hours, normal conditions every 7-8 years. ‘Mounting: Hetstick: Live ine mounting wth KENS mounting tool (Conitucter sae: 5-24 frm) Temperature: ~ 40 to #86 [0] Housina: Pohearbonate, UV stabized Dimension: 202 x 5 fr (th box, 295,658) Weight: 460 [a] (Box and battery included) agree of protectin IPS

You might also like