Descriptions Orifice Flow Max. working Max. working Apparent power (VA) Power consumption (W)
EX- Port Rated Weight
XPLNprf size characteristics press diff MPa pressure When holding When starting AC
Model No. size voltage DC (kg)
(mm) C[dm3/(s·bar)] b AC DC MPa 50 Hz 60 Hz 50 Hz 60 Hz 50/60 Hz
XPLNprf
NC
HVB/ FAB11- M5 -Z 1 0.12 0.64 0.7 0.7
HVL M5 3.4 2.6 5 4.6 2.3/1.6 3 0.07
S AV B/ -1 1.5 0.28 0.52 0.3 0.3
1.0
NAB FAB21- 6 -1 1.5 0.28 0.52 1.0 1.0
Rc1/8 5.3 3.7 10 9 2.7/2 4 0.12
LAD/ -2 2 0.55 0.59 0.6 0.6
NAD FAB31- 6 -2 2 0.55 0.56 1.4 1.4 100 VAC
Water- 8 Rc1/8 50/60 Hz
Rela -3 3 1.2 0.56 1.0 0.6 7.5 5.5 20 17 4/3.4 6.5 0.21
Rc1/4
NP/NAP/ -6 5 3.1 0.50 0.3 0.15 200 VAC
NVP 8 50/60 Hz
FAB41- -3 3 1.2 0.56 1.4 1.4
10 Rc1/4
SNP -5 4 2.1 0.54 1.0 0.9 24 VDC 15 11 40 35 7.5/6.5 8 0.37
Rc3/8 1.4
-7 7 5.7 0.48 0.25 0.15 12 VDC
CHB/G FAB51- 10 -5 4 2.1 0.54 1.2 1.2
Rc3/8
MXB/G -6 5 3.1 0.50 0.7 0.8
10
20 16 55 45 11/9.5 11.5 0.60
FAB51- -7 Rc3/8 7 5.7 0.48 0.3 0.3
Other 15
valves -8 Rc1/2 10 5.5 0.41 0.15 0.15
SWD/ NO
MWD FAB32- 6 -2 2 0.57 0.53 1.1 1.1
8 Rc1/8
DustColl -3 3 1.2 0.57 0.55 0.55 11.5 8 25 22 4.6/3.2 6 0.31
Rc1/4 100 VAC
CVE/ -6 5 3.0 0.48 0.2 0.2
50/60 Hz
CVSE FAB42- 8 -3 3 1.2 0.50 0.9 0.9 *3
10 200 VAC
CCH / -5 4 2.1 0.54 0.55 0.55 1.4 50/60 Hz 18 14 45 40 7.5/6.5 8 0.54
CPE/D -7 Rc1/4 7 5.2 0.41 0.15 0.15
24 VDC
LifeSci FAB52- 8 -5 Rc3/8 4 2.1 0.54 0.8 0.8
10 12 VDC
Gas- -6 5 3.0 0.52 0.5 0.5 25 20 60 50 11/10 11.5 0.71
Combus -7 7 5.2 0.41 0.25 0.25
Auto-
Water *1 : The voltage fluctuation range must be within ±10% of the rated voltage. Voltage
Leakage current
*2 : The leakage current must be less than or equal to the values shown 100 VAC 200 VAC 24 VDC 12 VDC
SpecFld on the right. Model No.
*3 : 8.6 (W) for 12 VDC. FAB1 2 mA or less 1 mA or less
1 mA or 2 mA or
Custom *4 : Effective cross-sectional area S and sonic conductance C are FAB2 3 mA or less 1.5 mA or less
converted as S ≈ 5.0 x C. less less
FAB3/4/5 6 mA or less 3 mA or less
*5 : The 100 VAC (50/60 Hz) can be used with 110 VAC (60 Hz).
Ending The 200 VAC (50/60 Hz) can be used with 220 VAC (60 Hz).
52 E
FAB Series
How to order EXA
F A B 2 1 6 1 1 2C A B 1 Model No. FWD
F A B 21
F A B 31
F A B 41
F A B 51
F A B 32
F A B 42
F A B 52
F A B 11
(2-port valve)
USB/G
Code Content
Working fluid A Series size
(Compressed air) A Series size FAB/G
1 18 mm ●
2 22 mm ● FGB/G
3 28 mm ● ●
4 34 mm ● ● FVB
5 40 mm ● ●
FWB/G
B Actuation
B Actuation
1 NC ● ● ● ● ●
FHB
2 NO ● ● ●
Model : FAB
2CG Conduit (CTC19) ● ● ● ● ● ● MXB/G
2CH Conduit (G1/2) ● ● ● ● ● ●
●
A Series size : 22 mm Other
3T With T type terminal box (G1/2) ● ● ● ● ● ●
●
B Actuation : NC valves
●
C Port size : Rc1/8 3RS
T type terminal box with lamp/
● ● ● ● ● ● SWD/
●
D Orifice size : φ1.5 surge suppressor (G1/2) MWD
●
E Body/sealant combination G Manual override DustColl
: Body - aluminum, sealant - NBR, G Manual override Blank Std. None ● ● ● ● ● ● ● ●
actuation - NC *6 CVE/
A Manual locking ● ● ● ● ●
Option
●
F Coil option : Grommet lead wire CVSE
N Manual non-locking ● ● ●
●
G Manual override : Manual locking CCH /
●
H Other options : Mounting plate H Other options CPE/D
H Other
●
I Voltage : 100 VAC50/60 Hz
options
Blank Std. None ● ● ● ● ● ● ● ● LifeSci
Option
53
FAB Series
FAB*1 Series: NC
EXA Internal structure and parts list
● FAB*1 Series
FWD
1
HNB/G
USB/G
FAB/G 2
FGB/G
FVB 3
FWB/G
4
FHB
5
FLB IN OUT
AB
AG
AP/
AD No. Part name Material
APK/ 1 Coil assembly - -
ADK
2 Plunger assembly SUS, NBR Stainless steel, nitrile rubber
DryAir 3 O-ring NBR Nitrile rubber
EX- 4 Spring SUS Stainless steel
XPLNprf 5 Body ADC Aluminum die-casting
XPLNprf
HVB/
HVL
S AV B/ Dimensions
NAB
LAD/ ● Grommet lead wire
NAD FAB*1-*-*-*2C
Water-
Rela F G H
NP/NAP/
NVP L
K
SNP
CHB/G
MXB/G
Other
E
valves
D
Ending
54
FAB Series
FAB*1 Series: NC
Optional dimensions EXA
(Refer to the dimensions of grommet lead wire on the left page for common dimensions.)
● Grommet lead wire with surge suppressor
FWD
● DIN terminal box (with lamp/surge suppressor)
FAB*1-*-*-* 2CS FAB*1-*-*-* 2G
HNB/G
A B 2HS
A
F E (Coil width)
USB/G
B
FAB/G
C
FGB/G
OUT
FVB
IN OUT
D
OUT
IN OUT FWB/G
B
35 EX-
D XPLNprf
XPLNprf
HVB/
HVL
D
36 S AV B/
C NAB
B
OUT IN OUT
IN OUT LAD/
G1/2 NAD
Water-
Rela
Model No. A B C D
NP/NAP/
Model No. A B C D E
CTC19
NVP
FAB31 39 48.5 28 G1/2 FAB31 92 60.5 48.5 74.5 28
FAB41 43 57.5 34
CTC19
FAB41 96 64.5 57.5 83.5 34
SNP
G1/2
CTC19
FAB51 46.5 71.5 40 FAB51 99.5 68 71.5 97.5 40
G1/2 CHB/G
CVE/
CVSE
E CCH /
6-H 4-G CPE/D
L
IN OUT
LifeSci
J
Gas-
K
Combus
Model No. A B C D E F G H J K L Auto-
FAB11 40 30 30 21 10 10 φ5 φ4.5 6 1.2 19 Water
Manual override
FAB21 40 34 30 25 15 15 φ5 φ4.5 6 1.2 20 SpecFld
FAB31 52 42 40 30 18 18 φ6 φ5.5 7 1.6 25
FAB41 56 48 44 36 18 18 φ6 φ5.5 7 1.6 30 Note : Non-locking is available only Custom
for sizes 3/4/5.
FAB51 62 50 50 38 20 20 φ6 φ5.5 7 1.6 36
Ending
55
FAB Series
FAB*2 Series: NO
EXA Internal structure and parts list
● FAB*2 Series
FWD
1
HNB/G
USB/G
2
FAB/G
FGB/G
3
FVB
FWB/G
4
FHB 5
FLB 6
IN OUT
AB
AG
AP/
AD No. Part name Material
APK/ 1 Coil assembly - -
ADK
2 Core assembly SUS, Cu Stainless steel, copper
DryAir 3 Valving element guide assembly PPS, SUS, NBR Polyphenylene sulfide, stainless steel, nitrile rubber
EX- 4 O-ring NBR Nitrile rubber
XPLNprf 5 Spring SUS Stainless steel
XPLNprf 6 Body C3771 Copper alloy
HVB/
HVL
S AV B/ Dimensions
NAB
LAD/ ● Grommet lead wire
NAD FAB*2-*-*-*2C
Water-
Rela F G H
NP/NAP/
NVP
L
SNP
K
CHB/G
MXB/G
Other
valves
SWD/
E
MWD
View A
D
DustColl
* Lead wire length 300 mm
CVE/
CVSE IN OUT
CCH /
C
CPE/D
LifeSci A J
B
Gas- ↑
Combus View A
Auto-
Water Model No. A B C D E F G H J K L
SpecFld FAB32 36 18 11 62.5 84 18.5 22.5 28 Rc1/8, Rc1/4 18 M5 depth 6
FAB42 40 21 12 71.5 96 22.5 26 34 Rc1/4, Rc3/8 18 M5 depth 8
Custom
FAB52 40 21 12 78 103.5 26 29.5 40 Rc1/4, Rc3/8 18 M5 depth 8
Ending
56
FAB Series
FAB *2 Series: NO
Optional dimensions EXA
(Refer to the dimensions of grommet lead wire on the left page for common dimensions.)
● Grommet lead wire with surge suppressor FWD
● DIN terminal box (with lamp/surge suppressor)
FAB*2-*-*-* 2CS FAB*2-*-*-* 2G
HNB/G
A B 2HS E (Coil width)
A
USB/G
B
FAB/G
FGB/G
FVB
D
FWB/G
IN OUT F
IN OUT
FHB
FLB
Model No. A B Model No. A B C D E F
FAB32 29.5 28 FAB32 58.5 47 39 56.5 28 Pg11 AB
FAB42 34 34 FAB42 62 50.5 39 65 34 Pg11
AG
FAB52 37.5 40 FAB52 65.5 54 39 73.5 40 Pg11
AP/
● Conduit (CTC19 / G1/2) ● T type terminal box (with lamp/surge suppressor) AD
FAB*2-*-*-* 2CG (G1/2) FAB*2-*-*-* 3T APK/
2CH 3RS ADK
C (Coil width) E (Coil width)
A A DryAir
B 35 EX-
XPLNprf
D
XPLNprf
HVB/
HVL
36
D
S AV B/
C
NAB
B
IN OUT LAD/
IN OUT G1/2 NAD
Water-
Rela
Model No. A B C D Model No. A B C D E
NP/NAP/
CTC19 NVP
FAB32 39 58 28 G1/2 FAB32 92 60.5 58 84 28
FAB42 43 67 34
CTC19
FAB42 96 64.5 67 93 34
SNP
G1/2
CTC19
FAB52 46.5 75 40 FAB52 99.5 68 75 101 40
G1/2 CHB/G
● Mounting plate Material : S
teel MXB/G
FAB*2-*-*-** B Zinc plated
Other
A valves
C SWD/
MWD
DustColl
CVE/
D
B
CVSE
CCH /
CPE/D
E LifeSci
6-H 4-G
Gas-
L
Combus
Auto-
J
Water
K
SpecFld
Model No. A B C D E F G H J K L
FAB32 52 42 40 30 18 18 φ6 φ5.5 7 1.6 25 Custom
FAB42/52 56 48 44 36 18 18 φ6 φ5.5 7 1.6 30
Ending
57
Direct acting 2-port solenoid valve for compressed air, manifold
(Special purpose valve)
58
GFAB Series
How to order EXA
● Manifold
G F A B 3 1 2 7 1 2C N 1 FWD
● Manifold with masking plate HNB/G
G F A B 2 5 1 X 1 2G N 2 5 2
USB/G
No. of ports Model No. FAB/G
GFAB21/25
GFAB31/35
GFAB41/45
GFAB51/55
GFAB11/15
(2-port valve)
FGB/G
Working fluid
(Compressed air) Code Content
FVB
A Series size
A Series size 1 18 mm ●
●
FWB/G
2 22 mm
3 28 mm ●
4 34 mm ●
FHB
5 40 mm ●
FLB
B Circuit configuration
B Circuit configuration 1 NC/common supply ● ● ● ● ● AB
5 NC/individual supply ● ● ● ● ●
C Orifice size AG
C Orifice size Z φ1 ●
1 φ1.5 ● ●
AP/
2 φ2 ● ●
AD
3 φ3 ● ● APK/
5 φ4 ● ● ADK
6 φ5 ● ● DryAir
7 φ7 ● ●
EX-
D Manifold station No. XPLNprf
D Manifold station No. 2 2 stations
*1 ● ● ● ● ● XPLNprf
to to
*2
10 10 stations
HVB/
0 Actuator only ● ● ● ● ●
HVL
X With masking plate ● ● ● ● ●
S AV B/
E Body/sealant combination NAB
E Body/sealant combination Body Seal LAD/
1 PPS NBR ● ● ● ● ● NAD
F Coil option Water-
F Coil option 2C Std. Grommet lead wire ● ● ● ● ● Rela
*3
*4
2CS Grommet lead wire
With surge suppressor ● ● ● ● ● NP/NAP/
*5
2G With DIN terminal box (Pg11) ● ● ● ● ● NVP
2HS DIN terminal box with lamp/
● ● ● ●
Option
59
GFAB Series
EXA Internal structure and parts list
● GFAB actuator
FWD
HNB/G 1
USB/G
FAB/G
2
FGB/G
FVB
FWB/G
3
FHB
4
FLB
AB 5
AG
6
AP/
AD
APK/ OUT IN
ADK
DryAir
EX-
XPLNprf
● GFAB manifold
XPLNprf
HVB/
HVL 1
S AV B/
NAB
LAD/
NAD 2
Water-
Rela
NP/NAP/
NVP 3
SNP
CHB/G 4
MXB/G
5
Other
valves
SWD/ 6
MWD
DustColl 7
CVE/
CVSE
CCH /
CPE/D
LifeSci
Gas-
Combus No. Part name Material No. Part name Material
Auto-
1 Coil assembly - - 5 Body PPS Polyphenylene sulfide
Water
2 Plunger assembly SUS, NBR Stainless steel, nitrile rubber 6 Gasket NBR Nitrile rubber
SpecFld
3 O-ring NBR Nitrile rubber 7 Sub-plate A6063 Aluminum
60
GFAB Series
Dimensions: Manifold EXA
● Grommet lead wire
FWD
GFAB**-*-*-12C
G H J K HNB/G
USB/G
FAB/G
F
FGB/G
E
FVB
M
D
L
FWB/G
B 2-C
A (C port)
FHB
2-S
FLB
AB
AG
T
N P n-Q
R AA (A port)
AP/
BB AD
APK/
Lead wire length 300 mm ADK
DryAir
Model No.
Station
No. 2 3 4 5 6 7 8 9 10 EX-
Code
GFAB1
XPLNprf
AA 48 68 88 108 128 148 168 188 208
BB 58 78 98 118 138 158 178 198 218 XPLNprf
GFAB2 AA 58 84 110 136 162 188 214 240 266 HVB/
BB 68 94 120 146 172 198 224 250 276 HVL
GFAB3 S AV B/
AA 74 106 138 170 202 234 266 298 330
NAB
BB 88 120 152 184 216 248 280 312 344 LAD/
GFAB4 AA 86 124 162 200 238 276 314 352 390 NAD
BB 100 138 176 214 252 290 328 366 404 Water-
GFAB5
Rela
AA 100 146 192 238 284 330 376 422 468
NP/NAP/
BB 114 160 206 252 298 344 390 436 482 NVP
Model No. A B C D E F G H J K L M N P Q R S T SNP
GFAB1 25 10 Rc1/8 8 44.5 54 13 17 19 20 11 16 21.5 20 M5 5 φ4.5 6.5
GFAB2 30 12 Rc1/8 8 49 60 15.5 19.5 21 26 8 16 25 26 Rc1/8 5 φ4.5 9
CHB/G
GFAB3 36 13 Rc3/8 12 64 76 18.5 22.5 28 32 15 24 34.5 32 Rc1/4 7 φ6.5 10
MXB/G
GFAB4 43 18 Rc3/8 12 71 85 22.5 26 31 38 15 24 31 38 Rc1/4 7 φ6.5 11.5
GFAB5 50 20 Rc3/8 12 79 95 26 29.5 34 46 12 24 34 46 Rc1/4 7 φ6.5 14
Other
valves
SWD/
Dimensions: Actuator MWD
● Grommet lead wire DustColl
GFAB**-*-0-12C
CVE/
D E F
CVSE
Model No. A B C D E F CCH /
GFAB1 25 28.5 38 13 17 18 CPE/D
GFAB2 30 33 44 15.5 19.5 22 LifeSci
C
B
Custom
Ending
* Lead wire length 300 mm
61
GFAB Series
EXA Actuator installation dimensions
● GFAB1*/2*/3*
FWD
Machining drawing when
using 2 actuators.
HNB/G
A
2n-H
USB/G
FAB/G
FGB/G
FVB
G
E
F
FWB/G
FHB
2n-J
FLB B
AB C
2n-K
AG D
AP/
AD
APK/
ADK
DryAir Model No. A B C D E F G H J K
+0.1
GFAB1 20 or more 5±0.15 12.4±0.1 14.4±0.1 10±0.15 11.2±0.1 17±0.1 φ3 φ1.6 depth 2.5±0.5 M2.5 effective thread depth 5.5 or more
EX- 0
XPLNprf GFAB2 26 or more 8±0.15 15.5±0.1 18.4±0.1 10±0.15 12.4±0.1 19.4±0.1 φ3.5 φ1.6 depth
+0.1
0 2.5±0.5 M3 effective thread depth 6 or more
GFAB3 32 or more 13±0.15 20±0.1 23.6±0.1 11.4±0.15 15±0.1 24.2±0.1 φ5.5 φ2.1 depth
+0.1
2.5±0.5 M4 effective thread depth of 6 or more
XPLNprf 0
HVB/
HVL
S AV B/
NAB ● GFAB4*/5*
LAD/
NAD Machining drawing when
Water- using 2 actuators.
Rela n-K
NP/NAP/
NVP A
2 × 2n-L
SNP 2n-J
CHB/G
MXB/G
F
Other
G
valves
E
SWD/
MWD
DustColl
CVE/ 2n-M
B
CVSE
CCH / C
CPE/D
D
LifeSci
Gas-
Combus
Auto-
Water
SpecFld Model No. A B C D E F G H J K L M
+0.1
GFAB4 38 or more 6±0.2 25±0.1 26±0.1 8.5±0.2 11±0.2 28±0.1 37±0.1 φ2.6 depth
0 2.5±0.5 φ8 M4 effective thread depth 9 or more φ5
Custom GFAB5 46 or more 8±0.2 30±0.1 30±0.1 11.5±0.2 14.5±0.2 33±0.1 43±0.1 φ2.6 depth
+0.1
0 2.5±0.5 φ11 M5 effective thread depth 8 or more φ7
Ending
62
GFAB Series
Optional dimensions EXA
(Refer to the grommet lead wire actuator dimensions on page 61 for common dimensions.)
FWD
● Grommet lead wire with surge suppressor ● Conduit (CTC19 / G1/2)
GFAB**-*-*-1 2CS GFAB**-*-*-1 2CG
2CH
HNB/G
A B
A C (Coil width)
USB/G
D FAB/G
FGB/G
B
FVB
FWB/G
HVL
S AV B/
D
NAB
36
D
LAD/
NAD
G1/2 Water-
Rela
Model No. A B C D E F Model No. A B C D E NP/NAP/
NVP
GFAB1 36 28.5 22 26.5 18 G1/4 GFAB4 96 64.5 42.5 68.5 34
GFAB2 53 44 38 26.5 22 Pg9 GFAB5 99.5 68 52 78 40 SNP
GFAB3 58.5 47 39 33.5 28 Pg11
CHB/G
GFAB4 62 50.5 39 40.5 34 Pg11
GFAB5 65.5 54 39 50.5 40 Pg11 MXB/G
Other
● Manual override (non-locking) valves
GFAB**-*-*-** N SWD/
MWD
DustColl
CVE/
CVSE
CCH /
CPE/D
LifeSci
Gas-
Combus
Manual override Auto-
Water
Position of manual override SpecFld
● Common supply : Opposite side to port A
Custom
● Individual supply : Port A side
Ending
63
Direct acting 3-port solenoid valve for compressed air, single unit
(Special purpose valve)
64
FAG Series
How to order EXA
F A G 1 1 M5 Y 1 2C A B 1 FWD
Model No. HNB/G
No. of ports
FAG31/33
FAG41/43
(3-port valve)
USB/G
FAG21
FAG51
FAG11
Working fluid
Code Content FAB/G
(Compressed air)
A Series size
A Series size 1 18 mm ● FGB/G
2 22 mm ●
3 28 mm ●
FVB
4 34 mm ●
FWB/G
5 40 mm ●
B Actuation FHB
B Actuation
1 Universal ● ● ● ● ●
3 NC pressurization ● ● FLB
C Port size AB
C Port size
M5 M5 ●
6 Rc1/8 ● ● AG
8 Rc1/4 ● ● ●
AP/
10 Rc3/8 ● ●
AD
D Orifice size APK/
D Orifice size ADK
Y φ0.8 ●
Z φ1 ● DryAir
0 φ1.5 ● ●
1 φ2 ● ● ● ●
EX-
XPLNprf
4 φ3 ● ● ●
8 φ4 ● ● XPLNprf
E Body/sealant combination HVB/
E Body/sealant combination Body Seal HVL
1 Aluminum NBR ● ● ● ● ● S AV B/
NAB
F Coil option LAD/
F Coil option 2C Grommet lead wire ● ● ● ● ●
*1 NAD
*2 2CS
Grommet lead wire
● ● ● ● ●
Water-
*3 with surge suppressor Rela
2G With DIN terminal box (Pg11) ● ● ● ● ● NP/NAP/
DIN terminal box with lamp/ NVP
2HS ● ● ● ●
surge suppressor (Pg11) SNP
2CG Conduit (CTC19) ● ● ●
2CH Conduit (G1/2) ● ● ● CHB/G
3T With T type terminal box (G1/2) ● ● ●
T type terminal box with lamp/ MXB/G
[Example of model No.] 3RS ● ● ●
surge suppressor (G1/2) Other
FAG11-M5-Y-12CAB-1 valves
G Manual override
Model : FAG G Manual
Blank Std. None ● ● ● ● ●
SWD/
●
A Series size : 18 mm override MWD
A Manual locking ● ● ● ● ●
Option
●
B Actuation : Universal
N Manual non-locking ● ● ● DustColl
●
C Port size : M5
●
D Orifice size : φ0.8 H Other options CVE/
H Other CVSE
●
E Body/sealant combination : Body - aluminum, sealant - NBR Blank Std. None ● ● ● ● ●
options CCH /
●
F Coil option : Grommet lead wire B Option Mounting plate ● ● ● ● ●
CPE/D
●
G Manual override : Manual locking I Voltage
●
H Other options : Mounting plate I Voltage
1 100 VAC 50/60 Hz ● ● ● ● ●
LifeSci
●I Voltage : 100 VAC 50/60 Hz *4
Gas-
2 200 VAC 50/60 Hz ● ● ● ● ●
3 24 VDC ● ● ● ● ●
Combus
Auto-
4 12 VDC ● ● ● ● ●
Water
Precautions for model No. selection Specify the desired voltage if it is not listed above.
SpecFld
*1 : For FAG11 Item F 2G, the compact terminal box (G1/4) is used. Select from the combinations indicated with ● in the table above.
*2 : For FAG21 Item F 2G/2HS, the DIN terminal box (Pg9) is used.
Custom
*3 : The surge suppressor is built into the coil for Item F 2CS and in the
terminal box for 2HS and 3RS.
*4 : Other voltages may not be available. Contact CKD for details. Ending
65
FAG Series
EXA Internal structure and parts list
● FAG*1/*3 Series
FWD 1
HNB/G
2
USB/G
FAB/G 3
FGB/G
4
FVB
FWB/G
5
FHB
6
COM NC
FLB
7
AB
AG 8
AP/ NO
AD
APK/ 9
ADK
No. Part name Material No. Part name Material
DryAir
1 Coil assembly - - 6 Valving element guide assembly PPS, SUS, NBR Polyphenylene sulfide, stainless steel, nitrile rubber
EX- 2 Plunger assembly SUS, NBR Stainless steel, nitrile rubber 7 Spring SUS Stainless steel
XPLNprf
3 O-ring NBR Nitrile rubber 8 O-ring NBR Nitrile rubber
XPLNprf 4 Spring SUS Stainless steel 9 Cover ADC Aluminum die-casting
HVB/ 5 Body ADC Aluminum die-casting
HVL
S AV B/
NAB Dimensions
LAD/
NAD ● Grommet lead wire
Water- FAG**-*-*-12C F G H
Rela
NP/NAP/
NVP
SNP
CHB/G
E
D
NO NC
COM NC
MXB/G
Other
C
valves
B
SWD/
MWD
NO A J K
DustColl N
CVE/
CVSE
CCH /
M
LifeSci L
Gas-
Combus
Auto- Model No. A B C D E F G H J K L M N
Water FAG1 28 14 13.5 42 51.5 13 17 18 12 M5×0.8 21 7 M4 depth 5.5
66
FAG Series
Optional dimensions EXA
(Refer to the dimensions of grommet lead wire on the left page for common dimensions.)
● Grommet lead wire with surge suppressor ● DIN terminal box (with lamp/surge suppressor)
FWD
FAG**-*-*-1 2CS FAG**-*-*-1 2G
2HS HNB/G
C
FGB/G
NO NC
COM NC
FVB
D
NO NC
COM NC
NO FWB/G
NO
FHB
Model No. A B Model No. A B C D E F
FLB
FAG1 24.5 18 FAG1 36 28.5 22 40 18 G1/4
FAG2 26.5 22 FAG2 53 44 38 44.5 22 Pg9 AB
FAG3 29.5 28 FAG3 58.5 47 39 54 28 Pg11
AG
FAG4 34 34 FAG4 62 50.5 39 68 34 Pg11
FAG5 37.5 40 FAG5 65.5 54 39 76.5 40 Pg11 AP/
AD
● Conduit (CTC19 / G1/2) ● T type terminal box (with lamp/surge suppressor) (G1/2) APK/
FAG**-*-*-1 2CG FAG**-*-*-1 3T ADK
2CH 3RS DryAir
E (Coil width)
EX-
A C (Coil width) A
XPLNprf
D B 35
XPLNprf
HVB/
36 HVL
D
S AV B/
NO NO
B
NO
C
COM NC COM NC NAB
G1/2
LAD/
NO NO NAD
Water-
Rela
NP/NAP/
Model No. A B C D Model No. A B C D E NVP
CTC19
FAG3 39 55.5 28 FAG3 92 60.5 55.5 81.5 28
G1/2
CTC19
SNP
FAG4 43 70 34 G1/2 FAG4 96 64.5 70 96 34
FAG5 46.5 78 40
CTC19
G1/2 FAG5 99.5 68 78 104 40 CHB/G
● Mounting plate Material : Steel ● Manual override (locking/non-locking) MXB/G
FAG**-*-*-1** B Zinc plated FAG**-*-*-1* A
N Other
A valves
C SWD/
4-G
MWD
DustColl
D
B
CVE/
6-H E
CVSE
CCH /
NC COM
CPE/D
J
L LifeSci
K
Manual override
Gas-
Model No. A B C D E F G H J K L Combus
FAG1 40 30 30 21 7 21 φ5 φ4.5 6 1.2 19
Auto-
Water
FAG2 40 34 30 25 8 25 φ5 φ4.5 6 1.2 20
FAG3 52 42 40 30 11 32 φ6 φ5.5 7 1.6 25 Note: Non-locking is available only for sizes 3/4/5. SpecFld
FAG4 56 48 44 36 15 35 φ6 φ5.5 7 1.6 30
Custom
FAG5 62 50 50 38 15 35 φ6 φ5.5 7 1.6 36
Ending
67
Direct acting 3-port solenoid valve for compressed air, manifold
(Special purpose valve)
Descriptions Port size Orifice Flow Max. working Max. working Apparent power (VA) Power consumption (W)
EX- Rated
XPLNprf 2-port 1. 3-port size characteristics pressure pressure When holding When starting AC
Model No. voltage DC
(Ind) (common) (mm) C[dm3/(s·bar)] b differential MPa MPa 50 Hz 60 Hz 50 Hz 60 Hz 50/60 Hz
XPLNprf
GFAG11 -Y 0.8 0.08 0.55 0.7
HVB/ M5 Rc1/8 3.4 2.6 5 4.6 2.3/1.6 3
-0 1.5 0.25 0.29 0.2
HVL
S AV B/ GFAG21 -Z Rc1/8 Rc1/8
1 0.12 0.44 0.7
5.3 3.7 10 9 2.7/2 4
NAB -1 2 0.42 0.19 0.15 1.0
100 VAC
LAD/ GFAG31 -0 1.5 0.28 0.46 0.7 50/60 Hz
NAD -1 Rc1/4 Rc1/4 2 0.49 0.36 0.4 7.5 5.5 20 17 4/3.4 6.5
Water- 200 VAC
Rela -4 3 0.90 0.20 0.2 50/60 Hz
NP/NAP/ GFAG41 -1 2 0.50 0.31 0.7
24 VDC
NVP -4 Rc1/4 Rc1/4 3 1.1 0.20 0.3 15 11 40 35 7.5/6.5 8
12 VDC
SNP -8 4 1.6 0.14 0.15
1.2
GFAG51 -1 2 0.50 0.31 1.2(0.6)
CHB/G -4 Rc1/4 Rc1/4 3 1.1 0.20 0.6(0.3) 20 16 55 45 11 /9.5 11.5
100 VAC 200 VAC 24 VDC 12 VDC The 200 VAC (50/60 Hz) can be used with 220 VAC (60 Hz).
DustColl Model No.
GFAG1 2 mA or less 1 mA or less
CVE/ 1 mA or 2 mA or
GFAG2 3 mA or less 1.5 mA or less
CVSE less less
GFAG3/4/5 6 mA or less 3 mA or less
CCH /
CPE/D Weight
LifeSci Model No. Actuator weight (kg) Masking weight (kg) Sub-plate weight (kg) (n: manifold station No.) Formula for product weight
Gas- (Product weight (kg)) = 0.07 x (Actuator quantity) + 0.008 x
GFAG11 0.07 0.008 0.024+0.025×n
Combus (Masking quantity) + 0.024 + 0.025 x (Manifold station No.)
Auto- GFAG21 0.12 0.012 0.027+0.043×n
(Product weight (kg)) = 0.12 x (Actuator quantity) + 0.012 x
Water (Masking quantity) + 0.027 + 0.043 x (Manifold station No.)
(Product weight (kg)) = 0.2 x (Actuator quantity) + 0.026 x
SpecFld GFAG31 0.2 0.026 0.06+0.08×n
(Masking quantity) + 0.06 + 0.080 x (Manifold station No.)
(Product weight (kg)) = 0.36 x (Actuator quantity) + 0.034 x
Custom GFAG41 0.36 0.034 0.067+0.11×n
(Masking quantity) + 0.067 + 0.11 x (Manifold station No.)
(Product weight (kg)) = 0.55 x (Actuator quantity) + 0.048 x
Ending GFAG51 0.55 0.048 0.08+0.15×n
(Masking quantity) + 0.08 + 0.15 x (Manifold station No.)
68
GFAG Series
How to order EXA
● Manifold
FWD
G F A G 2 1 Z 5 1 2C N 1
● Manifold with masking plate Model No. HNB/G
G F A G 3 1 1 X 1 2G N 2 4 1
G F A G 21
G F A G 31
G F A G 41
G F A G 51
G F A G 11
USB/G
69
GFAG Series
EXA Internal structure and parts list
● GFAG actuator
FWD
1
HNB/G
USB/G 2
FAB/G
3
FGB/G
FVB 4
FWB/G
5
FHB
FLB 6
AB
7
AG
AP/ 8
AD
APK/
ADK 9
DryAir
EX-
XPLNprf ● GFAG manifold
XPLNprf
1
HVB/
HVL
S AV B/ 2
NAB
LAD/
NAD 3
Water-
Rela
NP/NAP/ 4
NVP
SNP
5 6
CHB/G
MXB/G
Other
valves
SWD/ 7
MWD
DustColl
8
CVE/
CVSE
CCH /
9
CPE/D
LifeSci
10
Gas-
Combus
Auto- No. Part name Material No. Part name Material
Water 1 Coil assembly - - 6 Valving element guide assembly PPS, SUS, NBR Polyphenylene sulfide, stainless steel, nitrile rubber
SpecFld 2 Plunger assembly SUS, NBR Stainless steel, nitrile rubber 7 Gasket NBR Nitrile rubber
3 O-ring NBR Nitrile rubber 8 Holder SUS Stainless steel
Custom 4 Spring SUS Stainless steel 9 Spring SUS Stainless steel
5 Body PPS Polyphenylene sulfide 10 Sub-plate A6063 Aluminum
Ending * 4 body mounting screws and 2 O-rings are attached to the actuator only.
70
GFAG Series
Dimensions: Manifold EXA
● Grommet lead wire
J K
FWD
GFAG*1-*-*-12C G H
HNB/G
USB/G
FAB/G
E
F
FGB/G
M
FVB
L
D
U B
4-C
A 2-S
FWB/G
FHB
FLB
T
N P n-Q AB
R AA (Port 2) R
BB AG
Lead wire length 300 mm AP/
Model No.
Station
2 3 4 5 6 7 8 9 10 AD
Code No.
CPE/D
LifeSci
Model No. A B C D E F
Gas-
A Combus
GFAG1 25 33.5 43 13 17 18
Auto-
GFAG2 30 43 54 15.5 19.5 22 Water
GFAG3 36 51 63 18.5 22.5 28
SpecFld
GFAG4 43 60.5 74.5 22.5 26 34
GFAG5 50 67 83 26 29.5 40 Custom
* Lead wire length 300 mm
Ending
71
GFAG Series
EXA Actuator installation dimensions
● GFAG1*/2*/3*
FWD
Machining drawing when
using 2 actuators.
HNB/G
A
FGB/G
FVB
FWB/G
G
F
FHB
FLB
2n-L
AB B
n-H (NO side (or NC side))
C
AG 4n-M
AP/ D
AD
APK/
ADK
DryAir
Model No. A B C D E F G H J K L M
EX-
+0.1 +0.2 +0.1 +0.1
XPLNprf GFAG1 20 or more 9±0.15 12.4±0.1 14.4±0.1 11.2±0.1 16.4±0.15 17±0.1 φ2
0 φ12 ±0.1 depth 7 0 φ2 0 φ1.6 depth
0 2.5±0.5 M2.5 effective depth 5
0.1 0.2
GFAG2 26 or more 12±0.15 15.5±0.1 18.4±0.1 12.4±0.1 20±0.15 19.4±0.1 φ2.5 +0 φ14.5 ±0.1 depth 6.7 + 0 φ2.5 +00.1 φ1.6 depth
+0.1 2.5±0.5 M3 effective depth 6
XPLNprf 0.2
0
GFAG3 32 or more 17±0.15 20±0.1 23.6±0.1 15±0.1 24±0.15 24.2±0.1 φ3.4 +00.1 φ19.5 ±0.1 depth 7.6 + 0 φ3.4 +00.1 φ2.1 depth
+0.1
0 2.5±0.5 M4 effective depth 6
HVB/
HVL
S AV B/ ● GFAG4*/5*
NAB
LAD/ Machining drawing when
NAD using 2 actuators.
Water-
Rela
NP/NAP/ A
NVP n-K (NC side (or NO side))
CHB/G
MXB/G
Other
valves
E
G
F
SWD/
MWD
DustColl
CVE/ 4n-M
CVSE B
n-H (NO side (or NC side))
CCH /
CPE/D
C 2n-L
LifeSci
Gas- D
Combus
Auto-
Water
SpecFld
Model No. A B C D E F G H J K L M
Custom GFAG4 38 or more 11.8±0.15 25±0.1 26±0.1 28±0.1 31.8±0.15 37±0.1 φ4.1 +0.1 +0.2
0 φ22 ±0.15 depth 11.2 0 φ4.1 φ2.6 depth 2.5±0.5 +0.1
0 M4 effective depth 12
GFAG5 46 or more 11.8±0.15 30±0.1 30±0.1 33±0.1 31.8±0.15 43±0.1 φ4.1 0 φ22 ±0.15 depth 11.2 +00.2
+0.1
φ4.1 φ2.6 depth 2.5±0.5 +0.1
0 M5 effective depth 8
Ending
72
GFAG Series
Optional dimensions EXA
(Refer to the grommet lead wire actuator dimensions on page 71 for common dimensions.)
FWD
● Grommet lead wire with surge suppressor ● Conduit (CTC19 / G1/2)
GFAG*1-*-*-1 2CS GFAG*1-*-*-1 2CG HNB/G
2CH
A B USB/G
A C (Coil width)
FAB/G
D
FGB/G
FVB
B
FWB/G
FHB
Model No. A B
GFAG1 24.5 18 FLB
GFAG2 26.5 22 Model No. A B C D
GFAG3 29.5 28
AB
GFAG3 39 46 28 CTC19 / G1/2
GFAG4 34 34 GFAG4 43 56 34 CTC19 / G1/2 AG
GFAG5 37.5 40 GFAG5 46.5 64 40 CTC19 / G1/2
AP/
AD
● DIN terminal box (with lamp/surge suppressor) ● T type terminal box (with lamp/surge suppressor) (G1/2)
APK/
ADK
GFAG*1-*-*-1 2G GFAG*1-*-*-1 3T
2HS 3RS DryAir
E (Coil width)
EX-
A
E (Coil width) XPLNprf
A
B XPLNprf
F B 35 HVB/
HVL
S AV B/
C
CKD NAB
LAD/
NAD
Water-
D
D
36
Rela
C
NP/NAP/
NVP
G1/2
SNP
Model No. A B C D E F
GFAG1 36 28.5 22 31.5 18 G1/4 CHB/G
GFAG2 53 44 38 36.5 22 Pg9
GFAG3 58.5 47 39 44.5 28 Pg11
MXB/G
Model No. A B C D E
GFAG4 62 50.5 39 54 34 Pg11 GFAG4 96 64.5 56 82 34 Other
GFAG5 65.5 54 39 62.5 40 Pg11
valves
GFAG5 99.5 68 64 90 40
SWD/
MWD
● Manual override (non-locking) DustColl
GFAG*1-*-*-** N
CVE/
CVSE
CCH /
CPE/D
LifeSci
Gas-
Combus
Auto-
Water
Manual override SpecFld
73