Setpoints (set the System Voltage with DIP switches 2 3):
Regulation Voltage: 13.65 V (12V), 27.30 V (24V) Float Voltage: disabled V (12V), disabled V (24V) Time Before Float: 3:00:00 h:m:s (12V), 3:00:00 h:m:s (24V) Time Before Float (low battery): 3:00:00 h:m:s (12V), 3:00:00 h:m:s (24V) Float Low Battery Threshold: 0.00 V (12V), 0.00 V (24V) Equalize Voltage: disabled V (12V), disabled V (24V) Reference Charge Limit: 13.75 V (12V), 27.50 V (24V) Battery Current Limit: 15.00 A (12V), 15.00 A (24V) Temperature Compensation: -0.000 V/degC (12V), -0.000 V/degC (24V) High Voltage Disconnect: 0.00 V (12V), 0.00 V (24V) Max charge reference: disabled V (12V), disabled V (24V) Max Temperature Compensation: 40 degC (12V), 40 degC (24V) Min Temperature Compensation: -30 degC (12V), -30 degC (24V) Battery Temperature Limit for 100%: disabled degC (12V), disabled degC (24V) Array Voltage Fixed Target: 0.00 V (12V), 0.00 V (24V) Low Voltage Disconnect: 12.50 V (12V), 25.00 V (24V) Low Voltage Reconnect: 13.30 V (12V), 26.59 V (24V) Load High Voltage Disconnect: disabled V (12V), disabled V (24V) Load Current Compensation: 0.010 ohm (12V), 0.010 ohm (24V) LVD Warning Timeout: 1 min (12V), 1 min (24V) LED G -> G/Y: 13.20 V (12V), 26.41 V (24V) LED G/Y -> Y: 13.10 V (12V), 26.20 V (24V) LED Y -> Y/R: 13.00 V (12V), 26.00 V (24V) LED Y/R -> R: 12.80 V (12V), 25.59 V (24V) Modbus ID: 1 (12V), 1 (24V) Meterbus ID: 1 (12V), 1 (24V) Va sunrise threshold: 53.0 % (12V), 53.0 % (24V) Va sunset threshold: 42.0 % (12V), 42.0 % (24V) Channel 0 invert: false (12V), false (24V) Channel 0 combine: OR (12V), OR (24V) Channel 0 Timer 0: turn on 0:30 before sunset min (12V), turn on 0:30 before sunset min (24V) Channel 0 Timer 1: turn off 1:00 before midnight min (12V), turn off 1:00 before midnight min (24V) Channel 1 invert: false (12V), false (24V) Channel 1 combine: OR (12V), OR (24V) Channel 1 Timer 0: turn on 4:00 after midnight min (12V), turn on 4:00 after midnight min (24V) Channel 1 Timer 1: turn off 0:20 after sunrise min (12V), turn off 0:20 after sunrise min (24V)