Professional Documents
Culture Documents
3
What is SVMPC1
• SVMPC1 saves energy by reducing wasteful operation
SVMPC1 can limit the setpoint range to prevent too low/high
setpoint.
• SVMPC1 has user-friendly operation screen
Everyone can use SVMPC1 without special training by simple easy
screen on tablet.
• SVMPC1 allows to control air-conditioning from anywhere
Your smartphone will be a remote controller for VRV through WiFi
and the Internet.
• SVMPC1 notifies malfunction to service contractor (not in
the premises)
SVMPC1 sends alert e-mail to registered person who in charge of
maintenance.
4
SVMPC1: System Structure
SVMPC1 DTA116A51
WiFi router
Internet
DTA116A51
5
SVMPC1: Functions *: only admin user can set
Category Function Detail
Access security User login User name, password
Device registration Registered device(Tablet, Smartphone) can access
through the internet
Main screen Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error,
Error code, Room Temperature
Manual operation On/Off, Setpoint, Operation mode, Fan step, Flap
Automatic control Setpoint range Cool setpoint min/max, Heat setpoint min/max
limitation*
Off timer* Off timer on/off, Off timer duration(5min – 12h, every
5min)
Setback operation* Setback setpoint range (Cool: 24-35C, Heat: 10-20C)
Schedule* Action registration: Time, On/Off, Setpoint, Operation
mode, Fan step, Flap, Off timer on/off, Setback setpoint
7
SVMPC1: Specifications
Category Specification Detail
Connectable units Number of indoor units Max 32 (with additional DTA116A51)
8
SVMPC2
Smartphone Remote Controller
for building
What is SVMPC2
SVMPC2 is a VRV remote controller
• User’s smartphone will be a remote controller of VRV in a building.
Wall mounted remote controller is not
necessary.
• VRV can be controlled through the internet.
Whole building WiFi is not necessary.
SVMPC2
Internet
DCM601A51
Router
DCM601A51
11
Outside of the building In the building
SVMPC2: Functions *: only admin user can set
Category Function Detail
Access security User login User name, password
Device registration Registered device(Tablet, Smartphone) can access
through the internet
Main screen Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error,
Error code, Room Temperature
Automatic control Setpoint range limitation* Cool setpoint min/max, Heat setpoint min/max
Off timer* Off timer on/off, Off timer duration(5min – 12h, every 5min)
12 Password setting
SVMPC2: Screen image
Setpoint range
Operation limitation
screen
Monitor
Login screen
screen
Language
User
Password
Pointsetting
setting
setting
13
SVMPC2: Specifications
Category Specification Detail
Connectable units Number of indoor units Max 1024 (with 2 iTMs)
14