You are on page 1of 1
460mm Typ “F © S15M 3000mm long \ | S15M C— 560 For anchorage see OPSD 2215.02 250mm depth PLAN Barrier wall not shown Anchorage and conduit This surfoce to be steel float finished level | | 3 300 it 50mm 10mm — clear cover S15M _ 1M NOTES: SECTION A-A ‘~ S15! Siew CE A Reinforcing steel for deck and barrier wall not shown. 15M 3000mm long B Cover to reinforcing steel 70mm +20mm, except as noted. C Stainless steel bors shall be Type 316LN or Duplex 2205 with a minimum yield strength of 500 MPa. © Read in conjunction with bridge electrical details. E Anchorage based on 4-32mm dia studs on 406mm bolt circle diameter. F_All_dimensions_are_in_millimetres_unless_otherwise_shown. ONTARIO PROVINCIAL STANDARD DRAWING. DECK LIGHT POLE BASES STRUCTURES WITH BARRIER WALLS OPSD 3360. 100