PHARMA ENGINEE

[HOW TO] Select A Motor Capac

INPUT DATA

Volume to be
10 Cu.m
pumped

Differential Head 18 m

OUTPUT DATA

Motor Capacity
Required
ARMA ENGINEERING

[HOW TO] Select A Motor Capacity

INPUT DATA

Density of Solvent 1000 Kg/Cu.m

Average Pump
0.75
Efficiency

OUTPUT DATA

0.65 KW

0.88 HP