You are on page 1of 1

The test data given are based on tests done according to the referred standards or methods.

The data are


quality assured extracts from comprehensive test reports. If not specified differently Drying/Curing is done at
room temperature (23°C) and relative humidity below 85%. The test results may be influenced by factors not
specified in the summary.

Straight comparison of test data can not be made unless application, curing and testing are done under
identical conditions.

Test Report
Test Coating System Basic Parameters Test Results
No
ISO 6270-1:1998- 1 RESIST 86 - 80 µm Substrate : Mild Steel DFT : 245 µm 2015-00143
Resistance to humidity, 2 HARDTOP OPTIMA - 100
Continuous Condensation µm Substrate : 5 mm Blistering : 0
[Jotun Performance 3 HARDTOP OPTIMA - 100 thickness (ISO 4628)
Coatings Testing µm Surface : Sa2 1/2 Rusting (ISO : Ri 0
Department, Sandefjord] assessment (ISO 8501 4628)
-1) Cracking : 0
Surface : Medium (ISO 4628)
roughness Flaking (ISO : 0
(ISO 8503-2) 4628)
Comments : Cross-cut :
classification
Curing : 38 d
(ISO 2409)
duration
Exposure : 768 h
Pull-off : 12.2 MPa
adhesion
duration
Adhesion : B/C
fracture type
Result : 90% B/C
comments 10% Y/-

Comments:

Performance Coatings Page 1 of 1


2018.12.07