Eaton 9390 UPS: Product Brochure
Eaton 9390 UPS: Product Brochure
100-160 kVA
UPS EFFICIENCY
in energy costs over traditional UPS designs. Now with the 90%
available Energy Saver System (ESS), the 9390 achieves over
99 percent efficiency no matter how large or small the load.
This additional energy savings is achieved through advanced
power core technology, and continues to provide the load with 80%
maximum protection. Unlike traditional “eco” modes, ESS is
not just a utility bypass. The load is always protected. Learn TYPICAL
more at Eaton.com/ESS and see how much money you can OPERATION
save with our UPS efficiency calculator.
70%
20% 30% 40% 50% 60% 70% 80% 90% 100%
UPS LOAD
* Includes savings realized through minimizing UPS energy losses and reduced cooling requirements.
“The units’
efficiency
definitely played
a role in our
selecting the 9390
… ESS will pay
for itself within
the year.”
- Tim Cooper,
data center
facilities
manager,
Travelport
Retrofit applications
Competition’s
The 9390 is perfect for retrofit operations. When an existing UPS is
exceeding capacity but has no room to expand, or when the service Weight = 2700 pounds
contract is expiring, the existing UPS can be removed and replaced 32.5 in. x 34.9 in.
with a 9390 that offers more power in less space.
Service Plans
PowerTrust™ PowerTrust
Eaton 9390 UPS Service Plans Value ProActive PowerTrust Preferred Flex Contracts
• Included feature
Optional
Proven warranty and support services Extensive service options for enhanced reliability
Customers consistently rank Eaton services number one in quality. For support beyond the warranty period, Eaton offers enhanced
Eaton’s comprehensive, world-class service solutions are designed service options including onsite startup, corrective and preventive
to improve costs, uptime, reliability, power quality and safety. And maintenance, battery solutions, training, remote monitoring and
with 240 field technicians in North America and 1,200 international factory spare parts and upgrades. Customizable three-phase UPS
authorized service providers, Eaton has more service personnel services packages allow customers to select the plan that provides
than any other UPS manufacturer. the right combination of system uptime, convenience and value.
The standard factory warranty covers:
• System warranty: One year parts / 90 days labor
• Battery warranty: Two years parts / 90 days labor
Leading kW Lagging
Without derating
0.25
Connectivity options
Flexibility
• A variable battery bus accommodates 384 to 480V configurations,
so the battery capacity can be matched to your exact runtime
requirements – either a specific runtime, an extended runtime, an
extension to an existing battery, or legacy battery installations 73.7”
31.6”
42.7”
Features
• Two, three or four-breaker maintenance bypass
• Transformer options up to K20
• (2) 42-pole panelboards
Or
• (1) 42-pole panelboard and up to (3) 250A distribution breakers
Or
• Up to (6) 250A distribution breakers
• Line and match or remote
• Casters and leveling feet
• Panelboards come with individual 225A main breaker
• Neutral rated for harmonic loads (200%)
• Distribution breakers are Eaton JG electronic trip
- Two electronic sensors available 100A and 250A
- 100A settings 40-100A trip (eight settings)
- 250A setting 100-250A trip (eight settings)
40-80 kVA IDC Bypass/transformer/
distribution cabinet
8” 22.5”
Rectifier input
(not shown)
System load
Bypass input
breaker (SLB)
Bypass breaker
UPS #2 output
(MOB 2)
UPS output
(isolation)
UPS #1 output
(MOB 1)
80 kVA 208 & 160 kVA 208V IAC-B Maintenance IAC-T Parallel Tie Cabinet
480V IAC-B bypass (160 kVA)
160 kVA 480V
IAC-SC
100-160 kVA (H x W x D, in) 73.7 x 22.5 x 31.6 73.7 x 42.7 x 31.6 73.7 x 22.5 x 31.6 73.7 x 22.5 x 31.6
100-160 kVA (H x W x D, in) 73.7 x 22.5 x 31.6 Up to 90 x 36 x 11.5 Up to 90 x 36 x 11.5 73.7 x 42.7 x 31.6
Redundant
power
supplies
DC connections
Modular static
switch assembly
Bottom cable
entry area
20-80 kVA
Replaceable converter/
inverter modules
Redundant power
supplies
Redundant
power
supplies
Input/output
connections
DC connections
Modular static
switch assembly
Bottom cable
entry area
100-160 kVA
kW 18 27 36 45 54 72 90 108 144 100-160 kVA modules HxWxD: 73.7 x 35.6 x 31.6 in./1872 x 904 x 803 mm
General characteristics 20-80 kVA modules 640 lb./290 kg (208V); 568 lb./258 kg (480V)
Efficiency Up to 94% 100-160 kVA modules 1,060 lb./481 kg (208V, 480V)
>99% with Energy Saver System
Serviceability
Parallel capability Four modules with tie cabinet
Back/side against Standard
Audible noise <65 dBA @ 1 meter wall installation
Altitude (max) 2000m at 40ºC , 104ºF Certification
Input characteristics Safety UL1778, cUL
Voltage 208, 380, 400, 415, 480, 6002 EMC IEC62040-2 EN50091 Class A (restricted access)
Voltage range +10% / -15% 3
Surge ANSI C62, 41 Cat, A&B
Frequency range 55-65 Hz Optional accessories
Power factor 0.99 (min) Module tie cabinet
Input current <4.5% (no input filter required) External maintenance bypass
distortion Integrated distribution cabinet
Isolation transformer
Soft start capability Yes
eNotify Remote Monitoring service option
Internal backfeed Yes
protection 24x7 remote monitoring of UPS and battery alarms, daily heartbeat
check and monthly report required.
Broadcast global Yes
support Communication options
Output characteristics Software compatibility - Intelligent Power Manager, FORESEER, Power Xpert
Communications cards - Two communications bays standard. Four
Voltage 208 , 380 , 400 , 415 , 480 , 600
4 4 4 4 4 5
communication bays included.
Regulation ±1% The following connectivity options can be installed at any time:
- Modus Card
Inverter PWM with IGBT switching - Relay Interface Card (Use for AS400s)
Voltage THD <2% (100% linear load); <5% (non-linear load) - Industrial Relay Card (5A@120V)
- Hot Sync CAN Bridge Card provides CAN communications,
Load power factor Down to 0.9pf leading without de-rating
isolated RS-485 port
range
- Environmental Monitoring Probe (EMP)
Heat dissipation 80 kVA, 208V: 23.6 - Power Xpert cards
(BTU/Hr x 1000/Hr) 160 kVA, 208V: 47.3 Remote inputs/outputs - two building alarms inputs and on summary alarm
80 kVA, 380-480V: 21.9 contact (5A@120V) standard
160 kVA, 380-480V: 43.8 Four more building alarm inputs available with the Communications Expansion
Battery Option Remote panel - eight backlit status indicator lamps plus an audible horn
*See the Limited Factory Warranty for 9390 products for details. Batteries are warranted by the battery
Battery types VRLA, AGM, Gel, Wet, Eaton batteries also available manufacturer and not by Eaton.
**Requires the Parallel Card option (RS-485 port) and requires an external 120V power supply to drive the
Battery voltage 384-480V remote monitor panel.
1. Due to continuing improvements, specifications are subject to change without notice.
Temperature Optional 2. 600V applications require an input transformer.
3. At full load without battery discharge.
compensation 4. Output transformers are required if the desired output voltage is not the same as the input voltage.
5. 600V applications require an output transformer.
Charging method ABM Technology
Learn more at
powerquality.eaton.com