You are on page 1of 1

T-7200- Touch Series

Specifications
Twin Column Floor Models 1. High Resolution LCD Touch Screen Console
T-72103 T-72203 T- 72253 T-72303 T- 72403 T- 72603
2. Stiffness Compensation virtually giving machine
stiffness of 0.1mm/100kN
Load Capacity : kN 100 200 250 300 400 600
kgf 10 Ton 20 Ton 25 Ton 30 Ton 40 Ton 60 Ton 3. Load Control, Strain Control, PID Loop rate up to
6khz.
Maximum Speed : mm / min 1016 508 508 508 508 508
(Optional) in / min 40 20 20 20 20 20 4. Video Extensometer connectivity through Wi--Fi,
LAN Connectivity for measuring Proof Stress-Strain,
Minimum Speed : mm / min 0.001 0.001 0.001 0.001 0.001 0.001
True Stress- Strain based a non-contact measurement
principle.
Maximum Force kN 75 100 125 150 250 400
at full Speed : kgf 7.5 Ton 10 Ton 12.5 Ton 15 Ton 25 Ton 40 Ton 5. High Speed data conversion rate up to 15,000/sec
6. TCPIP Connectivity to PC for high speed & long
Maximum Speed mm / min 762 254 254 254 254 254
at full Load : distance measurement up to 100mbps, immune to
industrial electrical noisy environment.
Return Speed : mm / min 1016 508 508 508 508 508
7. Remote connectivity through net, giving easy system
Position Control mm 0.001 0.00 1 0.001 0.001 0.001 0.001
access for serving back-up & software updates.
Resolution : 8. Advantage of touch screen console is it's a user
Total Crosshead mm 1450 1450 1450 1450 2050 2000
friendly console having a GUI(Graphical User
Travel : Interface) exhibiting menus, controls & parameters
Space Between mm 600 600 675 825 825 825 specific to processes making system easy to use and
Columns : analyze.
Height : 9. Direct port to connect digital measuring gauges like
Floor Model mm 2400 2400 2500 2500 3150 3150 digital vernier, micrometer etc enabling measurement
and feeding of specimen dimensions to the system for
Width : mm 1170 1170 1200 1200 1600 1600 calculation of cross sectional area.
10.Acceleration and deceleration time setting of the
Depth : mm 750 810 810 810 950 1056 cross head motion is settable for each test depending
Maximum Power on the material type giving precise loading on the
Requirement : VA 3000 * 3500 * 4000 * 4800 * 5200 * 6000 * specimen avoiding impact load at the stand of the test.
Common Specifications :
- Crosshead Speed Accuracy ( zero or constant load ) : ± 0.05 % of set speed.
- Position Measurement Accuracy:±0.02mm or 0.05% of displacement(whichever is higher)
- Data Acquisition Rate at the PC: Up to 1kHz simultaneously on extension, load and strain channels.
- Load cells: Low Profile Universal (LPU, Pan-cake) type load cells are supplied.
- Load cells have safe overload of 150% of its capacity.
- Class A type of Load cell & pre-amplifier: Load Measurement Accuracy of ± 0.5 % of reading down to 1/500 of load cell capacity.
- Class B type of Load cell & pre-amplifier: Load Measurement Accuracy of ± 0.5 % of reading down to 1/250 of load cell capacity.
- Class C type of Load cell & pre-amplifier: Load Measurement Accuracy of ± 0.5 % of reading down to 1/100 of load cell capacity. Meets or
exceeds ASTM E-4, Bs1610, DIN 51221, ISO 7500/1, EN 10002-2. JIS B7721 standards.
- Strain Measurement Accuracy : ± 0.5 % of reading down to 1/100 of full scale with ASTM E-83 class B or ISO 9513 class 0.5 extensometer.
Meets or exceeds ASTM E-83, BS 3846, ISO 9513 and EN 10002-4 standards.
- Single Phase Voltage : 100, 120, 220 or 240 VAC ± 10 % 47 to 63 Hz. Power supply must be free of spikes, surges or sags exceeding 10 % Of
the average voltage.(*220 or 440 VAC AC + 10% 47 TO 63 Hz., 3 Phase)
- Operating Temperature : 10 ° to 38 °C (+50 to +100 °F)
- Storage Temperature : - 40°C to 66°C (-40 to 150° F)
- Humidity Range : 10 % to 90 % non- condensing.
Notes :
- Extra-high or wide load frames and extra-high or low speed drive systems are also available. Contact your nearest Dak office for details.
- Total vertical test space is the distance from the top surface of the base platen to the bottom surface of the moving crosshead, excluding load
cell, Grips and fixtures.
- Total Test Stroke (with standard tensile grips) = 600 mm.(min).
- the above specifications were developed in accordance with Dak system Inc’s standard procedures and are subject to change without Notice.