DURBAR LOAD FORMULA (CHAPAS GOTA)

Type Thickness oMass (kg/m2) Design Constants


4.5 36.9 a1 1.333
5/7 5 45.0 a2 0.187
6/8 6 48.7 a3 0.351
8/10 8 64.4 a4 0.142
10 80.1 a5 0.211
12.5 99.7 a6 0.393
a7 2.000
Thickness 8 a8 11.350
Steel Grade 235 MPa a9 0.560
Young's Modulus 210 GPa a10 0.028
a11 0.224
Self W. 0.63 kN/m² a12 0.387
Dead Loads 0.0 kN/m² Poisson Ratio 0.3
Imposed Loads 12.0 kN/m²

Design Load 18.84 kN/m² Allowable deflection for imposed loads only
Service Load 12.63 kN/m² 1 / 250

Geometry
Bx By B L k Support Limit defl. Load capacity
(m) (m) Type (mm) (kN/m²)

1.00 10000.00 1.0 10000.0 1.00 SS 4.0 20.05


1.00 10000.00 1.0 10000.0 1.00 E 4.0 30.08

1.00 0.90 0.9 1.0 0.60 SS 3.6 41.66


1.00 0.90 0.9 1.0 0.60 E 3.6 309.10
Max. defl. Allowb. defl. Design
(mm) (mm)

15.87 4.00 No good


3.17 4.00 Design ok!

34.94 3.60 No good


1.45 3.60 Design ok!