‘Saudi Arameo 2616-ENG (03/99) [z SAUD! ARABIAN OIL COMPANY : ne a LL} aypgoul gSoly Saudi Aramco | WELL CORE FACILITIES : BI-10-02118-0001 [LL] SPRINKLER HYDRAULIC CALCULATIONS ISSUED FOR CONSTRUCTION PREPARED BY: JACOBS ZATE CONSULTING ENGINEERS AL-KHOBAR, SAUDI ARABIA. MARCH, 2018 =| HYDRAULIC CALCULATIONS: ‘owarvee] rawr wa] woex] _90eN0. ‘sw ¥0. ‘SPRINKLER HYDRAULIC CALCULATIONS Doc a eo i WELLCORE FACILITIES S04 oa DHAMRAN ‘SRUDTARABIA | Jorwo: _Bi-10-02718-0001 199 ‘Saudi Aramco 2616-£NG (03/09) SAUDI ARABIAN OIL COMPANY Fexoo]oenr] pr orang] DESSRPTION REVISION CERTIFICATION 4.0 PROJECT SUMMARY 1.1 The purpose of this report is to evaluate the adequacy of the pipe size for automatic sprinkler system by means of hydraulic analysis, and to determine whether the fire sprinkler main and system riser is adequately sized to supply maximum firewater demand and pressure at newly proposed Well core facility at Dhahran in Kingdom of Saudi Arabia 1.2, Well core facility is located in the light industrial park section of Dhahran. The proposed Well Core facility is required to consolidate the storage, handling and characterization ‘operations of the well cores and cuttings. 1.3 Well core facility fire water system consists of one electric motor driven fire pump, one diesel engine driven fire pump and two jockey fire pumps connected to a fire water main header with a minimum nominal pipe size of 8-inch (200-mm) that runs through the mechanical plant room and supplies water to six risers R1, R2, R3, R4 R5 and R6. Rt to Ré are of single interlock Preaction system risers, RS is Automatic Sprinkler system riser and R6 is one Double interlock Preaction system riser. The six riser’s location and istribution is selected such as to provide adequate protection for entire Well core facility 2.0 CODES & STANDARDS / REFERENCES IBC (ED: 2009) International Building Code IFC (ED: 2009) International Fire Code ‘vais NEPA, 13 (ED: 2013) Standard for the Installation of Sprinkler Systems. ‘SnER6.017 Fire Water System Design , SAES'S-450 ‘Sprinkler and standpipe system components in buildings “saebiva 4100 ‘Saudi Aramco Building Code "te calculation is based on the folowing project drawings: * — HA-041445.001 Ground floor Fire Protection Layout, Sht 1 * —-HA-041445.002 Ground floor Fire Protection Layout, Sht 2 © HA-041445.003 Ground floor Fire Protection Layout, Sht 3 © HA-041445.004 Ground floor Fire Protection Layout, Sht 4 © HA-041446.001 First floor Fire Protection Layout, Sht 1 © -HA-041446.001 First floor Fire Protection Layout, Sht 2 © HA-041446.001 First floor Fire Protection Layout, Sht 3 © —-HA-041446.001 _ First floor Fire Protection Layout, Sht 4 EE ATR ID TNT CORTES TERED BETTE PERT FET AACS PRISTON FLO PRT SR BETES PSO TS SORT WT WT CSET TSO HYDRAULIC CALCULATIONS owarvre| panna] wack] _woewa errno | avn SPRINKLER HYDRAULIC CALCULATIONS Doc WELLCORE FACILITIES sos} A} wecuse | o | oo ana RUDY ARITA vos: — BraOUETEaDOT is ‘Sau aramco 2616-ENG (03/99) SAUDI ARABIAN OIL COMPANY 4.0 PROPOSED FIRE PROTECTION SYSTEM DESIGN BASIS. 4.1. Design Basis Input is as follows: NGG|CERT] put [ore 4.1.1. Single Interlock Preaction System: a. Hazard Classification is High Piled Storage. b. Minimum ceiling design density is 0.3 GPM/ FT?. c. Maximum area per sprinkler is 100 Sq. Ft d. Combined Hose Stream allowance is 500 GPM, however it is not connected with this pre-action system. e. Minimum design area of operation is 2600 FT? (System area of operation increased by 30% for dry pipe systems). Riser — 1 design area: 2611 FT? Riser - 2 design area: 2630 FT? Riser — 3 design area: 2608 FT? Riser - 4 design area: 2608 FT? Ceiling/Roof height is 44.5 FT. Ceiling Sprinkler type is Standard response. Ceiling Sprinkler K-Factor is 11.2 (161.3) ‘Commodity classification: Single or double row rack storage of Class I! non- encapsulated commodities stored over 25 ft (7.6 m) in height, 8.0 feet aisle width, with ordinary temperature ceiling sprinklers and in rack sprinklers, as per NFPA(3, Figure:16.3.1.3.1.1 (A)(d) ‘DScrLr j. Minimum water demand for in-rack sprinklers where more than one level is installed in racks with Class II commodity is ten sprinklers i.e. five on each top foe, two levels. ERGnER Minimum In-rack sprinkler discharge is 30 GPM co |. In-rack sprinkler K-factor is 8.0 (115) Leiiiiaed 4.1.2 Double Interlock Preaction System: DESCRPTION -Fes a. Hazard Classification is Ordinary Hazard group-1 ane b. Minimum ceiling design density is 0.15 GPM/ FT?, — c, Maximum area per sprinkler is 130 Sq. Ft d. Combined Hose Stream allowance is 500 GPM per NFPA 13, Table 12.8.6.1, however itis not connected with pre-action systems. Minimum design area of operation is 2036 FT?, (System area of operation increased by 30% for dry pipe systems). Ceiling/Roof height is 9.84 FT. Ceiling Sprinkler type is Standard response. Celling Sprinkler K-Factor is 5.6 (80) Minimum residual pressure at the hydraulically most remote sprinkler is 7 PSI (0.5 Bar) per NFPA 13. ‘OPERATIONS oaziecotast HYDRAULIC CALCULATIONS: ‘waTYPE] puneT a] woEX] BONO. ‘nro, REVI, SPRINKLER HYDRAULIC CALCULATIONS Doc 3 WELLCORE FACILITIES soa | A| ecw | | og panna SAUDTARABIA | soiewo: _ 6110-02118.0008 199 REVISION CERTIFICATION Saudi Aramco 2616-£NG (03/95) SAUDI ARABIAN OIL COMPANY 4.1.3 Automatic Sprinkler System: Hazard Classification is ordinary hazard group-1. Minimum ceiling design density is 0.15 GPM/ FT? Maximum area per sprinkler is 130 Sq. Ft DESCRIPTION Hose Stream allowance: Inside: 100 GPM riser/system) . Minimum design area of operation is 1027 FT?. . Ceiling/Roof height is 13.9 FT. g. Ceiling Sprinkler type is Quick response. h. Ceiling Sprinkler K-Factor is 5.6 (80) (0.5 Bar) per NFPA 13. 5.0 CALCULATION SUMMARY aa [SSUED FOR CONSTRUTON 5.1 FIRE WATER FLOW TEST REPORT: DATE oro] venitcanon FE | REVISION CERTIFICATION Test Static Pressure: 70 PS! Total Residual Pressure: 20 PSI Test Flow: 2364 GPM Raw water allowance: 100 GPM. GPM at 20 PSI. 5.2 FIRE WATER SOURCE INFORMATION: Floor Fire Pump room. ‘Outside: 150 GPM, (Outside hose demand is not connected with this After deducted the Outside Hose stream & raw water, the available water flo * One (1) Electric fire pump capacity: 750 GPM @115 psi diffrential head i. Minimum residual pressure at the hydraulically most remote sprinkler is 7 PSI Fire hydrant flow test conducted at hydrant FH 444, & 406 conducted by Saudi Aramco Fire Protection Division at Area 9020, Dhahran, dated October 30, 2017 is as follows: Outside hose stream allowance: 400 GPM at 20 PSI, as per NFPA 13, section 12.8 1864 The Calculated System water demand for Single interlock, Double interlock and ‘Automatic sprinkler system is achieved through dedicated fire pumps (Electric and Diesel driven) connected to an external fire water network. All fire pumps are in Ground ¢ * One (1) Diesel driven fire pump capacity: 750 GPM@115 psi differential head ‘* Two (2) Jockey Pumps capacity: 30 GPM@125 psi differential head TS RAINS HD THE BORAT CONTR HERE ARE THE SOE PROP OF ST RES TIO WTO PTS BETAS POSH TS OCR WRT TT WEN CONSENT OFS OER TVORADUG GALGULATIONS ower] wom] oon rae [ee SPRINKLER HYDRAULIC CALCULATIONS boc 7 WELLCORE FAGITES 504] A] ecm | 4] op TATTRAN SAUDIARABIA | Jomwo: Bi10.02110-0001 199 eR ‘Saud Aramco 216-£NG (03/99) Calculation output is as follows: Calculated Residual Pressure Riser 3 Calculation output is as follows: a. Calculated Sprinkler Flow is 1121.73 GPM. b. Calculated In-rack sprinkler Flow is 347.7 GPM . Inside Hose Stream Allowance is 100 GPM (Not connected to this riser, considered to size fire pump as per NFPA 13, 12.8.2) . Total Firewater Demand is 1569.43 GPM e. is 122.00 PSI. a. Calculated Sprinkler Flow is 1069.32 GPM b. Calculated In-rack sprinkler Flow is 347.7 GPM ©. Inside Hose Stream Allowance is 100 GPM (Not connected to this riser, considered to size fire pump as per NFPA 13, 12.8.2) d. Total Firewater Demand is 1517.02 GPM z SAUDI ARABIAN OIL COMPANY, || The fire pumps are sized in accordance with SAES-B-017, section 13.1.4 and NFPA 13, ele section 12.8.2. eR 5.3 SYSTEM DEMAND INFORMATION: In-Rack Sprinkler: Calculation output is as follows: a. Calculated In-rack sprinkler Flow is 344.40 GPM 3 b. Calculated Residual Pressure is 38.17 PS! Sle In-rack sprinkler Balance a a. K-factor: 55.74 is b. Pressure at POC (point of connection) node 65: 38.90 4 cc. In-rack sprinkler flow: 347.7 GPM fe Riser 1: ze Calculation output is as follows: 82 a. Calculated Sprinkler Flow is 1121.5 GPM e b. Calculated In-rack sprinkler Flow is 357.7 GPM g c. Inside Hose Stream Allowance is 100 GPM (Not connected to this riser, considered 2 to size pump as per NFPA 13, 12.8.2) leg] © d. Total Firewater Demand is 1569.25 GPM ag ©. Calculated Residual Pressure is 118.47 PSI. eNonecr = Brine Riser 2: Zz é e. Calculated Residual Pressure is 126.75 PSI. Belz Ee ai Bec girl HYDRAULIC CALCULATIONS owarvre] panto] moex] _0OcNO. ‘sno. REVO. & ‘SPRINKLER RYORAULIC CALCULATIONS boc a i s it | i WeLtcone Facimes 504 [A [ween | 3] gy 21 EEE tpn Ss a RET ATT CED RTCA TSE TE TTT EROS TT HT BETES TET BOTT TTT TS TH ie ‘Saudi Aramco 2616-ENG (03/95) = Jescs|cert] purr DESORPTION, jOEVO| SAUDI ARABIAN OIL COMPANY Riser 4 Calculation output is as follows: a b. ij 4 Calculated Sprinkler Flow is 1069.57 GPM Inside Hose Stream Allowance is 100 GPM (Not connected to this riser, considered to size fire pump as per NFPA 13, 12.8.2) Total Firewater Demand is 1169.57 GPM Calculated Residual Pressure is 99.00 PSI. Riser 5 Calculation output is as follows: a b. © 4. Calculated Sprinkler Flow is 255.70 GPM Inside Hose Stream Allowance is 100 GPM Total Firewater Demand is 355.7 GPM Calculated Residual Pressure is 59.2 PSI. Riser 6 Calculation output is as follows: a. b. ©. a. Calculated Sprinkler Flow is 613.52 GPM Inside Hose Stream Allowance is 100 GPM (Not connected to this riser, considered to size fire pump as per NFPA 13, 12.8.2) Total Firewater Demand is 713.52 GPM Calculated Residual Pressure is 83.00 PSI Hence the highest fire sprinkler system water demand is 1517 GPM at 126.75 PSI and below is the hydraulic supply/demand curve for Riser 3. TS BTS ST TORTI CONTAINED REI FE THE SOE PROPERTY OF ROT HR” WS TEPRODTC TON FT TT BE REG PR TS BORER WHO TE WATT COST OFT ERTS ee « » z Bali ree ae _ Fa . = i Flowrate(x100) gpm ag? Eile 8232 £5 | hvonmuconcuanons Sint cwaree|arrvo] woor] eon: wane [aoe 01) [Semcenmomuue cxcuanons Doc e B29] 2 #[weitcore races 504 | A] wecaao | 6 | 26 82 dpwanran SAUDTARABIA | TOEWO: — Bi10-02116-0001 199 aul Aramco 2616-€NG (03/95) SAUDI ARABIAN OIL COMPANY Legend Description Public Water supply Fire Pam 3 Fire Pump & Public Water spp Paar a 6.0 RECOMMENDATION Construction Contractor shall perform the Hydraulics Calculations in accordance with SAES-S-050, 23.1.1.1 if the Shop Drawings are deviating from the IFC drawings. 7.0 CONCLUSION Proposed Fire pumps are adequate in size to fulfil the calculated Single interlock pre- action system, double interlock, and automatic wet sprinkler system demand. DESGRIPTION 8.0 ATTACHEMENTS 8.1 Hydraulic Calculation report generated using Elite Fire software. 82 Fire Protection Isometric drawings. 83 Fire Protection layout, which is providing Design Operation Area coverage details, 8.4 Fire Hydrant flow test report. XXX Bai zee a eeee g |bee? eegieg Bestia z i 2 | * [ivorauuc catcovarions aware] ruawr wo] woex] _ooeno, Sur. e 3 boc {| SPRINKLER HYDRAULIC CALCULATIONS 7 Hy i § s[WeLicone Facies soa] A | necamso | 7. @ 26 3 = B|DHAHRAN ‘SAUDTARABIA | Jorewo: _1-10-02118-0001

You might also like