User‘s Guide
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
5 Technical Data
5.1 Dimensions 11
5.2 Mechanical data 12
5.3 Electrical data 12
5.4 Operating conditions 12
5.5 Function indicators 13
Apendix
Product ordering code 15
Order information 15
2 www.balluff.com www.balluff.com 15
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
1.1 About this guide This guide describes the Balluff IO-Link Sensor-Hub. Connection to the superordinate
IO-Link master assembly is established by means of IO-Link protocol. From functional
perspective this compact and inexpensive module is comparable to a passive junction
box: accepting digital and analogue sensor signals and conveying them through the
IO-Link-Interface.
Status I/O LED 1...8/16
1.2 Structure of the The guide is organized so that the sections build on one another.
Indicator Function guide Section 2: Basic safety information.
Section 3: The main steps for installing the device.
Yellow Input/-Output signal = 1 Section 4: IO-Link, parameter and process data for the device.
Section 5: Technical data for the device.
Out Input/-Output signal = 0
1.3 Typographical The following typographical conventions are used in this guide.
conventions
1.3.1 Enumerations Enumerations are shown in list form with bullet points.
- Entry 1,
- Entry 2.
1.3.2 Actions Action instructions are indicated by a preceding triangle. The result of an action is
indicated by an arrow.
¾ Action instruction 1
Ö Action result.
¾ Action instruction 2.
1.3.4 Cross references Cross references indicate where additional information on the topic can be found (see
section 5 „Technical Data”)
Note!
This symbol indicates a security notice which must be observed.
14 www.balluff.com www.balluff.com 3
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
2.1 Intended use This guide describes the Balluff Network Interface BNI IOL-… for the application as 5.5 LED Indicators
peripheral in-/ output module to establish connection of binary standard sensors or
actuators. Hereby it is about an IO-Link device which communicates by means of IO-Link
protocol with the superordinate IO-Link master assembly.
Status LED 2
Indicator Function
Green Module supply voltage is OK
Green ßasing Module supply voltage < 18V
Green, slowly ßashig Overload, total current > 1A
Out Module is without voltage
Indicator Function
Green No communication
Green, negative pulsed Communication ok
Red ßashing Communication overload
Out Module is without voltage
4 www.balluff.com www.balluff.com 13
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
Ripple < 1%
12 www.balluff.com www.balluff.com 5
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
3.2 Mechanical BNI IOL-309/310-000-K024/K025: Standard DIN rail mounting 5.1 Dimensions
connections
3.3 Electrical The Sensor-Hub Modules require no separate supply voltage connection.
connections Power is provided through the IO-Link interface by the host IO-Link Master.
Pin Requirement
24V Power supply controller, +24V, max. 1,0A
AUX
24V
IOL
0V
3.6 Connecting
Sensors/Actuators Figure 5-1: BNI IOL-310-000-K025
Pin Requirements
1 2 3 4 5 6 7 8
Input / Output
Input: EN: 61131-2, Type: max 30V
I/O
I/O
Note:
For the digital sensor inputs follow the input guideline per EN 61131-2, type 2.
Outputs may be loaded by max. 350mA.
6 www.balluff.com www.balluff.com 11
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
Vendor ID 0x0378
4.5 Events Class / QualiÞer
Code ( high + low) Device ID 0x050901
Mode Type Instance
Appears Error AL Device Hardware Supply Supply low voltage U2 = Supply +24V BNI IOL-310-000-K025
C0 hex 30 hex 03 hex 5000 hex 0100 hex 0010 hex 0002 hex
IO-Link Version 1.0
Frame type 1
Parameter Data
Disappears Error AL Device Hardware Supply Supply low voltage U2 = Supply +24V
80 hex 30 hex 03 hex 5000 hex 0100 hex 0010 hex 0002 hex
Minimal cycle time 3 ms
80 hex 30 hex 03 hex 5000 hex 0100 hex 0060 hex Input Data: Data that are transmitted from the device to the master.
Output Data: Data that are transmitted from the Master to the device.
B3 hex 5160 hex
10 www.balluff.com www.balluff.com 7
Balluff Network Interface / IO-Link BNI IOL IP20 Device Balluff Network Interface / IO-Link BNI IOL IP20 Device
0 = Input
1 = Output
0x42 In case of error Pin 1 to Pin 16 (reading /writing)
Byte 0 1
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Pin 8 7 6 5 4 3 2 1
Subindex 8 7 6 5 4 3 2 1
8 www.balluff.com www.balluff.com 9