You are on page 1of 1

DESIGN OF COLUMN FOUNDATION DWELLING UNIT

INPUT DATA UNIT F1 -JT-


---------------------------------- DL+LL
LOAD FACTOR lf 1.500
UNIT WT OF SOIL GAMMA D T/m3 1.800
DEPTH OF FDN D m 1.000
DIRECT LOAD P Ton 6.000
GROUND BEAM LOAD GBL Ton 0.000
TOTAL VERTICAL LOAD Vl Ton 6.000
MOMENT about X-DIR Mx Tm 0.150
MOMENT about Y-DIR My Tm 0.150
HOR.LOAD X-DIR(BASE) Hx T 0.150
HOR.LOAD Y-DIR(BASE) Hy T 0.150

ASSUMED INPUT DATA


----------------------------------
OVERALL THK OF SLAB d0 m 0.200

LENGTH OF FOOTING L m 1.200


WIDTH OF FOOTING B m 1.200
LENGTH OF COL Lc m 0.250
BREADTH OF COL Bc m 0.250
DIA OF BAR X-DIR Dbx mm 10.000
DIA OF BAR Y-DIR Dby mm 10.000

DERIVED DATA
----------------------------------
WT.OF FDN&SOIL W=L*B*d0*2.5+(L*B-Lc T 2.704
*Bc)*(D-d0)*GammaD

TOTAL WT Wt=W+Vl T 8.704


TOT MOM AT BASE abt X Mbx=Mx+Hx*D0/2 Tm 0.165
TOT MOM AT BASE abt Y Mby=My+Hy*D0/2 Tm 0.165
MAX CANTELEVER X-DI C=(L-Lc)/2 m 0.475
MAX CANTELEVER Y-DI Cy=(B-Bc)/2 m 0.475
GROSS Pr(Max) Pmax=Wt/LB+Mbx*6/BL T/m2 7.419
+Mby*6/BL*B
GROSS Pr(Min) Pmin=Wt/LB-Mbx*6/BL T/m2 4.669
-Mby*6/BL*B
Ecc X-DIR EccX=Mbx/Wt m 0.019
Ecc Y-DIR EccY=Mby/Wt m 0.019

DESIGN OF SLAB F1 -JT-


---------------------------------- DL+LL
NET Pr X-DIR pn=Pmax-d0*2.5-(D-d0)* T/m2 5.48