You are on page 1of 14
eG swe ENDOR ANDHIKA PARAMARTHA, FYROM Sal oe Ni Stadart Bubble CPAP Ventilator for Neonatus and Pediatric Patients SPECIFICATION Power 350 Watt Weight 15 Kg Dimensio 580 X 310 X 1000 Oxygen / air blender Humidifier PEEP Bottle Reusable tube set Portable mini compressor CPAP frame with I.V. Pole System is 100% reusable Neonatus and Pediatric Patient Automatic control Up to 20 litre per minutes flow capability Stable censor for accuratee temperature control Solid stay relay for long life operation Automatic velve to cut off the O? (if the power is off) for safety Five alarm : Too high tempeerature, Too low tempeerature, No Tube set, Humidity fault PT, PENOAR ANDHIKA PARAMARTHA Mixesare 7 INFANT BLENDING RESUSCITATOR | SPECIFICATION Dimesion Oxygen / Ar Bleder System is 100% Reusale Portable Miini Compressor Input gas flow range Manometer Range Max Pressure relief 8L/Min Peak Inspiratory Pressure 8L/Min Recomended body weight Weight Power Supplay Operating Time Charging Time Pressure Maximum a ~YNTROL IX SAFE 221 X 200 X 170mm 10 L/Min flow capability 0 - 80cm H*O 5 - 70cm H*O 1-9cm HO Up to 10kg (22 Ib) Approx. 4kg 12 VDC Aprrox, 120 - 180 minutes 3 hours (at complete discharge) 2542 Psi /2+0.2 bar Advantage system is compact and easy use PT, PENOAR ANDHIKA PARAMARTHA = Ve RIDAR ANDHIKA PARAMART! OX 102s CONCENTRATOR FILTER REGULATOR NASAL AIR FILTER CANNULA SPECIFICATION Oxygen Flow Range 1-51/min Oxygen Concentration 90 % - 92 % +3 Max. Outlet Pressure 8 Psit1 Noise Level Below 55 dBA Voltage 230 V /50 Hz Current 1,60 Amp +10% Operating Temperature Range 10°C - 40°C Operating Humidity Range 10 - 90 % RH Weight 17 Kg Electrical Safety Type B - Classic Il Filter, Air Filter, Regulator, Nasal Cannula Failure PLP Petiba, ANDHIKA Pana R_ANDHIKA PARAMARTH, ~ae P Phototherapy Cuivr™ (D - — J SPECIFICATION Dimension (Lx W x H) Power Requirement LED output Blue light wave length Blue light radiation power Lamp house angle Phototherapy lamp Castor Timer PT. FYROM INTERNATIONAL Medical Equipment Manufacture 600 X 680 X 1200 X 1700 AC 220 V, 50 Hz 81 Pcs x @ 1.03 VA (84 Wa’ 420 475 nm > 30 u W/cm2 300 to every direction with ball joint and 3600 vertical rotation 81 Pcs Blue Led 2 Inch 1 Automatic Timer and 1 Hour meter for LED Lamp MOBILE SPECIFICATION Capacity ot Suction Vacuum adjustment Overflow Protection Vacuum Display Power Supply Operating Time Condensate Trap Sound Level Dimension Ambient Conditions Reservoir Volume Vacuum Max (at Sea Level) Warranty Weight Battery Level Indication Charging Time PT. FYROM INTERNATIONAL Medical Equipment Manufacture S- 20 L/Min Infinitely Variable Integrated Overflow Protecti Into the machine, with Bacterial F Precision Indication Vacuum Gaus NS 8.5VDC Battery Operated 40 minute | \ Quick Visual Inspection Whether Device is Contaminated or over sucked 50.0 dB (A) @ 1m (ace to ISO 7779 221 x 200 x 170 mm (H x W xD) -30...450°C, 5...90%, Air Humility withoi Transport/Storage at Air, Preasure 700 -1060 Kl 2x 2500 mi +80 kPa +2 kPa/-800 mbar +20 mbar/-600 mmHg #15 mmHg One Year limited Warranty 20 kg Digital display 2.5 hour (at complete discharge) — = ane NDAR ANDHIKA PARAMARTI (NEA Li TRANSPORM § SPECIFICATION Power Source Power Consumption Power Supplay Battery life time Dimention Max. Hight Castors Mattres size Mattrees to hood Control Panel type Control Mode Controller type Air mode control range Skin mode control range Warm-up time Humidity range Noise levelin Power failure Information on Panel Control Alarms PT. FYROM INTERNATIONAL Medical Equipment Manufacture CUBATOR AC 220 V / 50 He DC 12V/28 Ah 110 w Battery Sealed Lead Acid Rechargeable 3 hours (Opt) 1150 X 550 X 999 mm. 1250 mm (folded trolley for ambulance fixtation) ” 300 X 600 X 30 mm 260 mm Soft touch botton Manual (air mode) Microcontroller 26.0°C - 37.0°C, Override 38.0°C, Resuolution 0.5°C 26.0°C - 37.0°C, Override 38.0°C, Resuolution 0.5°C £15 minutes 15 - 990% RH(A) £50 db Audible (Buzzer) Alarms, Fan indication failure, Sensor room alarm, Sensor Skin alarm, Heater indication failure system failure Skin over temperature (37.5°C) Air over temperature (37.5°C) Sensor failure Fan failuree PL PENDOR ANOHIKA PaRAMaRTHg aap ag INFANT INCUBATO im INTRODUCTION - Two temperature control mode bt micro - computer - Set & baby temprature can e display separetely - User friendit operating control - Max. Power output 350 Watt PT. FYROM INTERNATIONAL Medical Equipment Manufacture 5 seetremintcom a seu ~ Bian notes pan asaoeri FEATURE Control System Control Module BBaby’s Compartment Mai Body Power System/Heater Accesories Microcontroller temperature system with air & skin sensor Actual and Setting temperaturee LED digital display Soft touched control panel Skin and air sensor On-Off heaterindikator Panel indikator consists off lamp indicator Operatonal button snd LED display __ 4 accss point with silicone seal, Acrylicbaby hood Heater with Fan 2 drawers and Cabinet attachmen, 2 side safety side guard Oxyge port Replaceable air filter, Replaceable water reservoir SPECIFICATION Dimension Power Requirement Heater Output Panel Indicator Temperature Control Range Castor Ambent Air Temperature Room Humidity Setting Temperature Fluctuation Temperature Controller Alarm Mattres Temperature Range Heater Warm up Time Sound Level PT. FYROM INTERNATIONAL Medical Equipment Manufacture 930 (L) X 600 (W) X 1320(H) mm AC 220 V, 50 HZ, 350 VA 350 Watt Max heater indicator, air temperature indicator, temperature indicator 26°C - 37°C (air and skin temperature) qr 18°C - 30°C 25% - 75% Max 0,5°C Power, air censor, skin censor, over temprature, failure identification Broken heater & fan circuit Max 0.5°C in every point Max 30 min Max 60d PL PEOAR ANDHIKA PaRAMARTHA Cx NZ INFANT WARMER (ZC 7-2m Cc — J Tas MRODUCTIANe © - Two temperature control mode bt micro - computer - Set & baby temperature can be display separately - User friendlt operating control - Max. power output 670 Watt FEATURE Control System Baby’s Compartment Main Body SPECIFICATION Dimension Power Requirement Power System/Heater APGAR Timer Heater Output Temperature control range Temperature Accuracy Room Humidity Temperature Control Mode Temperature Controller LED Heater Indicator Display Skin Censor Accuracy Alarm Identification APGAR TIMER INDICATOR Mattrass Temperature Setting Temperature Rise Time Setting Temperature Fluctuation Radiator Rotation Angle PT. FYROM INTERNATIONAL Medical Equipment Manufacture &.. wwe WARMER QZ "2-2 Air or skin temperature controlled by microcontroller Soft Touch Control Panel Floor and Baby’s basinet distance 950mm for easy usage Adjustable baby bassinet with Lock button gas spring Acrylic side-guard 2 Decks oxygen tube 500L X-ray Cassete tray 660 X 1130 X 1700 mm AC 220 V, 50 HZ, 680 VA Ceramic Heater Reminder tone ( adjustable ) Up to 24 hours set tiff 650 Watt Ss 26°C - 37°C ( air and skin temperature ) i 1°C-3°C 25% - 75% Skin or air/ bed p Hi temperature alarm over 37°C, Temperature set up / down indicator on LED display, Temperature set up and down button, Silence alarm button 20VA On/Off Max 0.3°C Power failure, Air censor failure, Skin censor failure, Hi temperature, Low temperature, Air/ skin censor broken circuit, Heater broken circuit alarm, Alarm silence button Reminder tone can be adjustable, Up to 24 hour set time Max tolerance +- 0.5°C in every position Max 30 min Max 0.5°C 30- 130 degree in two ways ( with lock button ) PL PENDOR ANOHIKA PanAMtaRTHg = NZ DNDHIK A PARAMARTH: ~ai- iniusion Pump A038 SPECIFICATION Unique Human The device Triggered the human voice prompt and stop injection Voice Alarm system Automaticly when there is any malfunction, making the infuson process safer and more relabble innfusion rate 1ml/h - 1,200mI/h ee Purge rate 100ml/h - 1000mI/h (100mI/h increment) = a KVO Rate ml/h - Sml/h(1ml/h increment) Accuracy of flow rate — Within +5% (after correct calibration) (Nominal Value) Infusion Volume ml - 9999ml Total Infusion Volume —0,1ml - 9999,9ml & Occlusion detection High : 800 + 200 mmHg (106.7 + 26.7 kPa) Pressure Medium : 500 + 100 mmHg ( 66.7 + 13.3 kPa) Low : 300 + 100 mmHg ( 40.7 + 13.3 kPa) Bubble detector Ultrasonic wave detector; detection sensitivity >25yL Alarms End of injection, occlusion, door open, bubble the tube, wrong setting, low battery, AC power pulld out Power source AC 100V - 240V, 50/60Hz; Internal rechargeable Li battery, ect. capacity 2 16.00mAh, 4 hours internal battery backup Operation conditions | Ambient tempereture : -30°C - + 55°C Relative humidity : <90% Atmospheric pressure : 86.0kkpa - 106.0kpa Storage conditions Ambient temperature: -30°C-+55°C Relative humidity: <95% Equipment Classification Class II, internal power supply, Type BF IP Grade IPX1 Dimension 140mm (L) x 157mm (W) x 220mm (H) Weight 1.8kg (net weight) PL PENDOR ANOHIKA PaRAMaRTHg Ce NZ Syringe Pump Mai} Large LCD Alarm Indicator Light 90° Rotatable Pole Clamp Features * Large & Colorful LCD display * History records * Interface * Adjustable buzzer volume * Anti-bolus function * Various visual and audible alarms * 900 rotatible pole clamp convenient for horizotal bar & vertical IV pole * Unique syring intelligent recognition techology * Dinamcally display the pressure * Double CPU ensuring safe infusion PT. FYROM INTERNATIONAL Medical Equipment Manufacture PT, PENOAR ANDHIKA PARAMARTHA Cen we 2 ANDHIKA PARAMARTH Syringe Pump Daw SPECIFICATION Infusion mode Applicable Syringe accuracy Infusion Rate Volume to be infused Volume infused KVO rate Bolus rate Alarms Power supplay Power consumption Nurse call alarm Classifications Dimensions Weight Waterproof Level Occulasion pressure Battery Operating conditions Transport conditions Operating conditions PT. FYROM INTERNATIONAL Medical Equipment Manufacture @3 o. Rate mode, Time mode, Dose mode Various brands of sterile syringe: Sml, 10ml, 20m, 30m, 50m, 60m + 2% (after syringe correct calibration) Sml syringe : 0.1- 150 ml/h 10ml syringe : 0.1 - 300 ml/h 20mI syringe :0.1- 600mI/h 30mI syringe : 0.1- 900mI/h 50m syringe : 0.1- 1500mI/h 0 - 1000(m!) 0-9999,9(ml) 0.1-2ml/h adjustable; default value:0.1ml/h Sm syringe : 100 - 150 ml/h 10m| syringe : 100 - 300 mi/h 20ml syringe : 100 - 600mI/h 30ml syringe : 100 - 900ml/h 50m syringe : 100 - 1500mI/h Infusion completion, Empty, Occulasion, Near completion, low battery, Syringe disengaged, No AC Power supplay, battery exhausted, Malfunction ect DC :12#1.2V AC: 100 - 240V, 50/60Hz 25VA Optional Class |, Type CF 300 X 130 X 125 mm 1.8kg 1Px3 (40 - 60) kPa Li_Polymer 7.4V 1900mAh. Recharge time : 10h with power on, 3h with power off Temperature :50°C - 40°C Relative humidity : 10 - 95% Atmosphere pressure : 86 — 106kPa Temperature :-20°C - 60°C Relative humidity : 10 - 95% Atmosphere pressure : 50- 106kPa Temperature : 20°C - 45°C Relative humidity : 10 - 95% Atmosphere pressure : 50- 106kPa PL ren ANDHIWA PARAMARTH i)

You might also like