Series Advanced Vector Control Inverter User's Manual 'su800 e Thank you very much for your buying SU800 series High- performance Vector Control Inverter. Before use, please read this manual thoroughly to ensure proper usage. Keep this manual at an easily accessible place so that can refer anytime as necessary. Safety Precautions Please read this operation manual carefully before installation, operation, maintenance or inspection In this manual, the safety precautions were sorted to “WARNING?” or “CAUTION”. Indicates a potentially dangerous situation which, Awarnine if can not avoid will result in death or serious injury. Indicates a potentially dangerous situation which, if can not avoid will cause minor or moderate Z\ caution injury and damage the device. This Symbol is also used for warning any un-safety operation. In some cases, even the contents of “CAUTION” still can cause serious accident. Please follow these important precautions in any situation. In some cases, even the contents of “CAUTION” still can cause serious accident. Please follow these important precautions in any situation. In some cases, even the contents of “CAUTION” still can cause serious accident. Please follow these important precautions in any situation. % NOTE indicate the necessary operation to ensure the device run properly. Warning Marks are placed on the front cover of the inverter. Please follow these indications when using the inverter. WARNING May cause injury or electric shock. © Please follow the instructions in the manual before) installation or operation. Disconnect all power line before opening front cover of unit. Wait at least 10 minutes until DC Bus capacitors discharge. e Use proper grounding techniques. e Never connect AC power to output UVW terminals. Operation Instruction of SU800 Series Inverter Contents Chapter 1 Introduction .......:sscccssecseeceennssseeraeeneeraeesaneneraneseeeeees 3 1.1 Description of Name Plate ...............cccesceeeseeeseesesseeneeeeneeee 3 1-2 Technology Features .....csusssssssesssesssessessesssssssssesssnseseeseeses 3 1-3 Installation... 1-4 Selection Gui Chapter 2 Wiring ....csssesecsscsssaeeeesrenesseecsneensseeransnneranevaneoneranenensens 1 2-1 Terminal Configuration .........cesccssesesssesssesseseesssnessenessesnee 11 2-2 Wiring Diagram ....sesscsssesssssssessesssessenssesssssrsssssnsensesssesssesess 12 Chapter 3 Operationn.........csscsseesseererensseeranseneraeeraneeneraceraneeee 16 3-1 Keypad Description .........sceseeceeeeteeenesseseeseneeeseseeseneese 16 Chapter 4 List of Function Parameters ... Chapter 1 Introduction Chapter 1 Introduction 1-1 Description of Name Plate MODEL: SU800-3R7G/5RS5P-4 INPUT: 3PH 380V SOHz/60Hz OUTPUT: 3PH 380V 9.0/13.0 RANGE: 0.1-320Hz 3.7/5. FREQ skW ANTM ETN 14011311111) MODE: SU800-3R7G/SR5P-4 —— 2: 1PH AC220V 4: 3PH AC380V 3R7: 3.7kW G: Constant torque P: Variable torque Series Advanced Vector Control Inverter 1-2 Technology Features Item SU800 VIF control Control Mode ‘Sensorless flux vector control (SVC)(Above 3.7K), \Close-loop vector control (FVC)(Above 3.7kW) Maximum frequency |0~600Hz_ 0.5kHz~8kHz Carrier frequency |The carrier frequency is automatically adjusted based on the load features. uojouny o1seq Input frequency | Digital setting: 0.01Hz resolution Analog setting: Maximum frequency x 0.025% IG Type: 0.5Hz/150%(SVC) Starttorque |p Type: 0.5Hz/100% Speed range 1: 100 (SVC) Operation Instruction of SU800 Series Inverter Item SU800 Speed stability accuracy 0.5% (SVC) |G Type: 60s for 150% of the rated current, ‘3s for 180% of the rated current. Overload capaclly /p Ty5¢: 60s for 120% of the rated current, 3s for 150% of the rated current. Auto-boost; Torque boost [customized boost: 0.1%~30.0% Straight-line V/F curve Multi-point V/F curve VIF Curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) V/F separation [2 types: complete separation; half separation Straight-line ramp. Ramp Mode Four groups of acceleration/deceleration time with the range of 0.00°6500.0s DC braking frequency: 0.00Hz~Maximum frequency z DC braking Braking time: 0.0s~36.0s ey Braking action current value: 0.0%~100.0% a |JOG frequency range: 0.00Hz~50.00Hz. s JOG control JOG acceleration/deceleration time: |0.0s~6500.0s. wee Man It implements up to 16 speeds via the simple pie Ps PLC function or combination of terminal states speeds It realizes process-controlled closed loop control Onboard PID system easily Auto voltage It can keep constant output voltage automatically tegulation(AVR) _|when the mains voltage changes Overvoltage/ ‘The current and voltage are limited automatically overcurrent stall |during the running process so as to avoid control frequent tripping due to over voltage/over current . ja |{t helps to avoid frequent over current faults of Rapid current limit the AC drive. It can limit the torque automatically and prevent Torque limit and frequent over current tripping during the running control process. Torque control can be implemented in ithe FVC mode. > ‘Control of asynchronous motor are implemented @ &| High performance |through the high-performance current vector a & control technology g s oi ins vt The load feedback energy compensates the ow re ide ‘voltage reduction so that the AC drive can = 7 continue to run for a short time Chapter 1 Introduction Item SU800 ‘suoqouny pezi!enpyAjpuy Rapid current limit It helps to avoid frequent over current faults of ithe AC drive. Timing control Timing range: 0.0Min~6500.0Min Communication methods RS - 485 Buluuny Command source ‘Operation panel/Control terminals/Serial |communication port You can perform switchover between these ‘sources in various ways. Frequency source ‘There are ten frequency sources. Digital setting, analog voltage setting, analog current setting, pulse setting, serial port setting. ‘You can perform switchover in various ways. Auxiliary frequency source There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. Input terminal ‘Standard: 4 digital input terminals(Below 5.5kW) /6 digital input terminals(Above 7.5kW); 1 analog input terminal(Below 5.5kW)/2 analog input terminals(Above 7.5kW); 1 voltage input (only support for O~10V, above 7.5kW), 1 voltage input(0~10V) or current input (4~20mA) Output terminal 1 High-speed pulse output terminal (Open- collector) (Above 3.7kW) 1 replay output terminal (Below 5.5kW)/2 replay output terminals(Above 7.5kW) 1 analog output terminal(3.7kW~5.5kW)/2 analog output terminal(Above 7.5kW), Support for '4~20mA current output or 0~10V voltage output Jeued uojjessdo pue Aejdsiq LED display It displays the parameters Key locking and function selection It can lock the keys partially or completely and define the function range of some keys so as to prevent mal-function. Protection mode Motor short-circuit detection at power-on, input/ output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection and overload protection Operation Instruction of SU800 Series Inverter Item SU800 Indoor, free from direct sunlight, dust, corrosive Installation location |gas, combustible gas, oil smoke, vapor, drip or salt. Fy Altitude Lower than 1000m 3 Ambient |-10°C ~+ 40°C ( de-rated if the ambient 3 temperature temperature is between 40°C ~50°C ) 3 Humidity Less than 95%RH, without condensing Vibration Less than 5.9m/s*(0.6g) Storage 0 Yo temperature [20°C ~* 60°C 1-3 Installation SIZE A Chapter 1 Introduction SIZE Model A od SU800-0R4G-2 $U800-0R75G-2 SU800-1R5G-2 $U800-2R2G-2 SU800-0R4G-4 SU800-0R75G-4 $U800-1R5G-4 SU800-2R2G-4 72 142 127 130 61 45 SU800-3R7G-2 SU800-3R7G/5R5P-4 | 85 SU800-5R5G/7R5P-4 180 134 167 72 5.5 SU800-7R5G/11P-4 $U800-11G/15P-4 106 240 168 230 96 45 $U800-15G/18.5P-4 $U800-18.5G/22P-4 $U800-22G/30P-4 151 332 183 318 137 $U800-30G/37P-4 $U800-37G/45P-4 217 400 216 385 202 SIZE C ———— SIZE Model od $U800-45G/55P-4 SU800-55G-4 SU800-75P-4 300 440 | 470 | 240 200 $U800-75G/90P-4 SU800-90G/110P-4 $U800-110G/132P-4 275 590 | 630 | 310 200 612 $U800-132G/160P-4 SU800-160G/185P-4 400 675 | 715 | 310 320 695 aul Operation Instruction of SU800 Series Inverter SIZE D Ao, & xe Outline dimention | Installation | Wall-mounted SIZE Model ‘mm! Size(mm) |_ Size (mm) WH [H1|H2] D [at [bt] dt | a2]a3|b2| 02 $U800-185G/200P-4] |_| calles D |susco-2o0G220P-4| 8/8 )S)8/8/8/8la\8lalgla SU800-220G/250P-4| ° | b |susco-2s0cr2e0r-4| 8/8 )8/8/2|8/S]2|\Sia/Sla suso0-2806/315P-4| ele lS/elgiyjalaixlel/a|a Bp susoosiscasor-4| 8/8/38) 8/S|S/S/=|8/8/s |= $U800-350G/400P-4] |. | = D |susoo-oocasop-4| 8/5) %) 8/2) R) Sl a/8/3/8 la SU800-450G/500P-4 Chapter 1 Introduction 1-4 Selection Guide Mod Input Rated Rated Rated Motor lel voltage output input output Power power(kW) |current(A)| current(A) | (kW) SU800-0R4G-2 0.4 5.4 25 04 SU800-0R75G-2 + 0.75 7.2 5 0.75 $U800-1R5G-2 Rg. 15 10 T 15 SU800-2R2G-2 2 2 22 16 "1 2.2 $U800-3R7G-2 g 3.7 17 16.5 3.7 SU800-5R5G-2 5.5 21 25 5.5 SU800-7R5G-2 75 31 32 75 SU800-0R4G-4 04 34 1.2 04 SU800-0R75G-4 0.75 3.8 25 0.75 $U800-1R5G-4 15 5 3.7 1.5 SU800-2R2G-4 2.2 5.8 5 2.2 SU800-3R7G/5R5P-4 3.7/5.5 10/15 9/13 3.7/5.5 SU800-5R5G-4 5.5 15 13 55 SU800-7R5P-4 75 20 17 75 SU800-7R5G/11P-4 7.5/1 20/26 17/25 7.5/1 $U800-11G/15P-4 Se 115 26/35 25/32 11/15 SU800-15G/18.5P-4 3 15/18.5 35/38 32/37 (| 15/18.5 SU800-18.5G/22P-4 = 3 18.5/22 38/46 37/45 | 18.5/22 SU800-22G/30P-4 g 22/30 46/62 45/60 22/30 SU800-30G/37P-4 30/37 62/76 60/75 30/37 SU800-37G/45P-4 37/45 76/90 75/90 37/45 $U800-45G/55P-4 45/55 90/105 90/110 | 45/55 SU800-55G-4 55 105 110 55 $U800-75P-4 75 140 150 75 SU800-75G/90P-4 75/90 140/160 | 150/176 | 75/90 $U800-90G/110P-4 90/110 160/210 | 176/210 | 90/110 $U800-110G/132P-4 110/132 | 210/240 | 210/253 | 110/132 $U800-132G/160P-4 132/160 | 240/290 | 253/300 | 132/160 Operation Instruction of SU800 Series Inverter ee Input Rated Rated Rated Motor lel voltage output input output Power power(kW) | current(A)| current(A)| (kW) SU800-160G/185P-4 160/185 | 290/330 | 300/340 | 160/185 SU800-185G/200P-4 185/200 | 330/370 | 340/380 | 185/200 SU800-200G/220P-4 200/220 | 370/410 | 380/420 | 200/220 SU800-220G/250P-4 3 220/250 | 410/460 | 420/470 | 220/250 $U800-250G/280P-4 g 3 250/280 | 460/500 | 470/520 | 250/280 SU800-280G/315P-4 | # t | 280/315 | 500/580 | 520/600 |280/315 SU800-315G/350P-4 $ 315/350 | 580/620 | 600/640 | 315/350 SU800-350G/400P-4 350/400 | 620/670 | 640/690 | 350/400 SU800-400G/450P-4 400/450 | 670/790 | 690/790 | 400/450 $U800-450G/500P-4 450/500 | 790/835 | 790/860 |450/500 10 Chapter 2. wiring Chapter 2 wiring 2-1 Terminal Configuration 1) 0.4KW-2.2kW AAAAAAAAIAZAZ RB RC S2 §1 REVFWD RS- RS+ FIC +10V GND 2) 3.7KW-5.5kW QAADAAAAA AA AAA A!D RB RC FWOREV S1 S2 $3 24V_MO1FOV FIC 10V GND RS+ RS-GND 3) Above 7.5kW 24V COMFWDREV S1 S2 S3 S4 COMMO1 QAAA AAA Ao QO AA) Z| ZZ) JID |D|D|D|DB RB 10V GND FIC FIV GNDFOC FOVGNDRS+ RS- TA TC RA RC Operation Instruction of SU800 Series Inverter 2-2 Wiring Diagram 1) 0.4kW-2.2kW Suggestion cirgilt for] Abnormal oF power ot Sort ie tection | - u AC three Ho phases power ‘oh mail v Ac 3a0V ti58 —® ; we 50/80 ie SIH E = smulei-fanction Unput tarainal 1 —_ input tarninal | Talc-Bcsin pit tral f rmulti-finetion (nput ternal RS+7 485+ Communication RS-} 485. Terminal B elt Delay 1 output +OV Ponsr supply for fen aay (00 [KEY AL anclog Ipotentionster keypad _ 19 TOV input ! FIG: wees | OA. 200 Sut SS i$ GND inputs | eee @ ismaincicuitterminal ismmain circuitterminal {is main circuit terminal Note: It is only for V/F control 12 Chapter 2 wiring 2) 3.7KW-5.5kW ‘Suggestion cireytt for] AmomeL or powgr instont short cireuit photection | AC chree | et phases porar . He | AG ga0v 415% —* eT 50/60 Ha riltI-furetlon (opt ternal | ulet-function input sarninal 2 lailti-functisn input terminal 3 multi-function input tereial 4 feti-furetion input tarainal 5 vith hish-sreed pula TE) MON) option for high speed GND, pulse output and open Ae GND | collector output = | 2av| "| a5 12) RSt 485+ communication RS-¢ 485. terminal fe RC wl ke } Delay 1 output ‘ADV Power swoply for Lee BB Fremieney setting NO Peguencyoting PID fing z FIC eine | vokagelcuant jo/s zonh tupnt | ty inuteuiech 1 jumper | ortfor FG caid/other CNA | external card @ismain circuitterminal » is main drcuit terminal Ef is main circuit terminal 13 Operation Instruction of SU800 Series Inverter 3) 7.5kW-160kW Suggestion cireygit oF ‘Abncrmsl oF pow i short circuit peprection | AG three ey phases power Ac say tisy —° | 7 50/60 He rulticfonetion input termine 1 fae wot tial | ey waist woot tmiale tT gy ani 1 seilog ae o-10¥i02 i pez ‘| rultctawsion to tmia¢ zea | ‘echscmel Be pe ae eal” Avot | EES austin won omit |] gq TERE [LGD suppore external 1 a oe at |keyped | MG:suppore encoder {keypad {S42 rogue | function |ST0: external serem [function 1 ag [OrC07 Tapa ey | 0/s°20n8 Trout iu option for high speed pulse output and open collector output 485+ communication 4g5- terminal Delay 1 output Delay 2 output @ismaincreuitterminal ip main drcutteminal “[} ismain circuit terminal Note: It is built-in braking unit for below 37kW, the braking unit is optional for 45-160kW 14 Chapter 2 wiring 4) 185kW-450kW Suggestion einer 70—~] Ainermal oo por Srstant shore cireaft re AC three phases power AC 280V 15% —? 50/50 Ha ahpaaiacnteoces ty, ictal oer ma att-foeton ipo tenia $ a rove = y + i patscfoetion tp amin | | gp ot Ta Toesion apa ariel “ith Ih ape ulse-tuye) 83 al [misters we smi § TT 4 at = Toou ptonforhighspost j pobeceipitees ope r9 pic GND | Caliactor output av Phe sapeart eater ae Bre 9 7] RSt+ 485+ Comniostion ‘BNO: support, encoder | RS-+ Terminal keypad. tcp va | ee SA: regular cerminal stoop | function RC STO: exter seran Q | 84 i = RB cicuriae waives Delay 1 output Frequency setting RA TA ‘voltage /ugtenif aT arith juslper met Delay 2 output porter afi TC [extermaleard s+ @ ismain crcuitterminal @ ismain circuit terminal “FY is main circuit terminal 15 Operation Instruction of SU800 Series Inverter Chapter 3 Operation 3-1 Keypad Description 1) 0.4KW-5.5kW Chapter 3 Operation 3) Function key description Key Name Description PRG Progrerning Entry or escape of first-level menu ENTER _ Data enter key’ Progressively enter menu and confirm parameters A up oe Progressively increase data or function codes DOWN v Decrement |Progressively decrease data or function codes Key In parameter setting mode, press this button . to select the bit to be modified. In stop and » Shift Key running display modes, cyclically displays, parameters by shift key. Start to run the inverter in keypad control @ Run key mode In running status, restricted by P7.02, can be| © Stop/Fault jused to stop the inverter. When fault alarm, reset key can be used to reset the inverter without any’ restriction. Determined by function code P7.01 0: No function 1: Switchover between operation panel command and remote operation command. It indicates the switchover between the current! command source and operation panel control (local operation). If the current command ame SRR Bey source is operation panel control, the key is| invalid. 2: Switch between forward and reverse, it ‘only valid when command source is operation panel channel. 3: Forward JOG |4: Reverse JOG M No function 4) Indicator light description Indicator Light Name Indicator light description Hz Frequency unit A Current unit v Voltage unit FWD) Extinguished: Forward operation HREY Light on: Reverse operation 17 Operation Instruction of SU800 Series Inverter Indicator Light Name Indicator light description Extinguished: Local operation LOCAL/REMOT Flickering: Terminal operation Light on: Communication control Extinguished: Running state FUNC/ERR, Flickering: Pre-alarm of overload Light on: Fault Extinguished: Stop mode Flickering: In the process of auto-tuning Light on: Running mode 18 Chapter 4 List of Function Parameters Chapter 4 List of Function Parameters lf PP-00 is set to a non-zero number, parameter protection is enabled. You must enter the correct user password to enter the menu. To cancel the password protection function, enter with password and set PP-00 to 0. Parameters menu the user customizes are not protected by password.Group P is the basic function parameters , Group D is to monitor the function parameters.The symbols in the function code table are described as follows: "ys": The parameter can be modified when the AC drive is in either stop or running state. "%&": The parameter cannot be modified when the AC drive is in the running state. "e": The parameter is the actually measured value and cannot be modified. v«": The parameter is factory parameter and can be set only by the manufacturer. Standard Function Parameters: pein Parameter Name Setting range Default | Property Group PO Standard Function Parameters 1: G type (Constant torque load) Model 2: P type (variable torque | dependent load e.g. fan and pump) (0: No PG (speed sensor) vector control Centro} mode 4: With PG (speed sensor)| 2 * vector control 2: VIF control 0: Operation panel control (LED off) Command 1: Terminal control (LED source selection | on} 2: Communication control (LED linking) P0.00 | G/P type display PO0.01 P0.02 19 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property 0: Digital setting (P0.08 preset frequency, can modify the UP/DOWN, power lost don’t memory) 1: Digital setting (P0.08, preset frequency, can modify the UP/DOWN, Main frequency |,.. power lost memory) P0.03 | —sourcex [2 Fv (above 7.5kW) 0 x elociion 4: Potentiometer on operation panel (below 5.5kW) 5: PULSE (S3, Above 3.7KW) 6: Multistage instruction 7: Simple PLC. 8: PID '9: Communication setting Auxiliary The same as P0.03 P0.04 frequency source | (frequency source X 0 * Yselection (selection) Auxiliary 0: Relative to the frequency source/maximum frequency F0,05 superposition Y |1: Relative to the main q * range selection |frequency source X Auxiliary frequency source] 9, _ P0.06 superposition Y 0%~150% 100% * range 20 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default | Property Unit's digit (Frequency source) (0: Main frequency source x 1: X and Y operation (operation relationship determined by ten's digit) Frequency _|2: Switchover between X source and Y POO7 superposition |3: Switchover between X ad * selection and "X and Y operation" 4: Switchover between Y and "X and Y operation" Ten's digit (X and Y operation) (0: X+¥ 1 XY 2: Both the maximum 3: Both the minimum Frequency |0.00Hz~maximum P0.08 praset frequency (PO.10) 50.00Hz | x Rotation 0: Same direction PO.08 direction 1: Reverse direction 7 * Maximum P0.10 frequency 50.00Hz~600.00Hz 50.00Hz * 0: P0.12 setting 1: Potentiometer on operate panel (below 5.5kW) Upper limit [FIV (above 7.5kW) POM frequency source|2: FIC 9 x 3: Reserved 4: PULSE (S3, above 3.7kW) 5: Communication setting Frequency lower limit Po.1z | Upper limit lo. 14-Maximum 50.00Hz | xr raquency. frequency P0.10 Upper limit |0.00Hz~Maximum PO.13 frequency offset |frequency P0.10 0.00Hz * Frequency lower |0.00Hz~Upper limit P0.14 limit frequency P0.12 0.00Hz * 7 Model P0.15 | Carrier frequency /0.5kHz~16.0kHz dependent * 21 Operation Instruction of SU800 Series Inverter Function code Parameter Name Setting range Default Property P0.16 Carrier frequency adjustment with temperature 10: No 1: Yes PO.17 Acceleration time| 41 0.00s~65000s Model dependent P0.18 Deceleration time ‘1, 0.00s~65000s Model dependent P0.19 Acceleration/ Deceleration time} unit 0: 1s 1: 0.18 2: 0.018 41 P0.21 Frequency offset of auxiliary frequency source| for X and Y operation 0.00Hz~Maximum frequency P0.10 0.00Hz P0.22 Frequency instruction resolution 2: 0.01Hz P0.23 Retentive of digital setting frequency upon power 0: Not retentive 1: Retentive P0.25 Acceleration/ Deceleration time base frequency (0: Maximum frequency (P0.10) 1: Set frequency 2: 100Hz P0.26 Base frequency for UP/DOWN modification during running (0: Running frequency 1: Set frequency Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property Unit's digit: Binding operation panel command to frequency source No binding Frequency source by digital setting 2: Potentiometer on operation panel (below 5.5kW) Binding be (soove 7.5kW) Po.ar |ommand SOurc® 4: Reserved ooo0 | vortes |S: PULSE (S3, above 3.7kW) 6:Multi-Reference '7:Simple PLC 8:PID '9:Communication setting Ten's digit: Binding terminal command to frequency source Hundred's digit: Binding communication command to frequency source 92 Group P1 Motor parameter 0: Gommon asynchronous Motor type motor Pig selection 1: Variable frequency 4 * asynchronous motor Rated motor Model P1.01 : 0.1kW~1000.0kW dependent * Rated motor Model P1.02 ge 1V~2000V dependent * 10.01A~655.35A, P1.03 Rated motor | (AC drive power <=55kW)| + Model * . current 0.1A~6553.5A, dependent (AC drive power >55kW) P1.04 Rated motor |0.01Hz~maximum Model * * frequency _|frequency dependent P1.05 | Rated motor /4rom-65535rpm Model | rotational speed dependent 23 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property 10.0010~65.5350 Stator resistance 3 (AC drive power <=55kW)| Tuned ree en et |0.00010~6.55350 parameter] * (AC drive power >55kW) 7 10.0010~65.5350 Rotor resistance i (AC drive power <=55kW)| Tuned PT ee |0.00010-6.55350 parameter] * (AC drive power >55kW) peakeg® —|o.01mH~655.35mH P1.08 feactancs (AC drive power <=55kW)|} Tuned * . (asynchronous 0.001mH~65.535mH parameter motor) (AC drive power >55kW) Mutual inductive |0.1mH~6553.5mH P1.09 reactance (AC drive power <=55kW)| Tuned * . (asynchronous |0.01mH~655.35mH parameter motor) (AC drive power >55kW) 10.01A~P1.03 (AC drive P1.10 Newco power <=55kW) Tuned * . gia ator) 10.1A~P1.03 (AC drive parameter power >55kW) Encoder pulses |, _ P1.27 per revolution 1~65535 1024 * 0: ABZ incremental P1.28 | Encoder type encoder 0 * 2: Resolver AB phase sequence of 7 P1.30 | ABZ incremental |: Fonward 0 x encoder AB . phase sequence Encoder install a e P1.31 angle 10.0~359.9° 0.0' * Rotation pole |, _, P1.34 logarithm 1~65535 1 * Speed feedback PG card break |0.0: No action P1.36 | ‘line detection |0.1s~10.0s 9.0 * time (0: No operation 1 1: static auto-tuning P1.37 Auf funina 2; dynamic auto-tuning 9 * 3: complete static auto- tuning 24 Chapter 4 List of Function Parameters aan Parameter Name Setting range Default |Property P2 Motor vector control parameter Speed loop P2.00 | proportional gain |1~100 30 * 1 Speed loop ~ P2.01 | time 1 (0-01s~10.00s 0.50s te Switchover P202 | frequency 1 _|0-00~P2.05 5.00Hz | xx Speed loop P2.03 | proportional gain |1~100 20 * 2 Speed loop ~ P2.04 i time 2 0.01s~10.00s. 1.00s * Switchover |P2.02~Maximum P2.05 frequency 2__|frequency 10.00Hz * Vector control P2.06 slip gain 50%~200% 100% * Time constant of P2.07 | FIC 17: Frequency upper limit reached 18: Frequency lower limit reached (Relate to running) 19: Under voltage state output 34 Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property 20: Communication setting Relay function |21: (Reserved) P5.03 | selection (TA- |22: (Reserved) 0 * TC) 23: Zero-speed running 2 (having output at stop) 24: Accumulative power- on time reached Pat Reserved 25: Frequency level 1 x detection FDT2 output 26: Frequency 1 reached output 27: Frequency 2 reached output 28: Current 1 reached output 29: Current 2 reached output 30: Timing reached output 34: FIV input limit exceeded 32: Load becoming 0 33: Reverse running P5.05 Reserved 34: Zero current state 4 * 35: Module temperature reached 36: Output current limit} exceeded 37: Frequency lower limit} reached (having output at stop) 38: Alarm output( Keep running) 40: Current running time reached 41: Fault 35 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property (0: Running frequency 1: Setting frequency YOP output 2: Output current P8.08 | sunction selection|3: Output torque 9 * 4: Output power 5: Output voltage 6: PULSE input (100.% corresponding to 100.0kHz) FOV output [7° FY P5.07 |function selection 9: Raseried 0 * (above 3.7K) 11. Length 411: Count value 12: Communication setting 13: Motor rotational speed 14: Output current (100.0% corresponding to 1000.0A) FOC output 15: Output voltage ; P5.08 |function selection|(100.0% corresponding to}, * (above 7.5kW) |1000.0V) 16: Motor output torque (Actual value, corresponding to the motor percentage) YOP output P5.09 maximum —|0.01kHz~100.00kHz 50.00kHz * frequency FOV bias P5.10 coefficient '-100.0%~+100.0% 0.0% « P5.11 FOV gain /-10.00~+10.00 1.00 * FOC bias P5.12 coefficient '-100.0%~+100.0% 0.0% * P5.13 FOC gain —_|-10.00~+10.00 1.00 * YOR output P5.17 delay time 0.0s~3600.0s 0.0s * RA-RB-RC/RB- P5.18 | RC output delay /0.0s~3600.0s 0.0s * time TA-TC output P5.19 delay time 0.0s~3600.0s 0.0s Bsa P5.20 Reserved _[0.0s~3600.0s 0.0s * P5.21 Reserved —_[0.0s~3600.0s 0.0s * 36 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default |Property 0: Positive logic 1: Negative logic Unit's digit: YOR Output terminal fy 's digit: RA-RB-RC/RB- P5.22 | valid mode Hundred's digi TATC | 00000 | Thousand’s digit: FOV (Above 3.7kW) Ten thousand’s digit: FOC (above 7.5kW) Group P6 Start/Stop parameter 0: Direct start 1: Rotational speed tracking restartidi BEARER P6.00 Start mode Hah 0 * 2: Pre-excited start (AC asynchronous motor) 3: SVC quick start 0: Start from the stop - frequency FO AOE a eget: Start from 0 0 * 2: Start from maximum frequency Rotational speed | , |. P6.02 tracking 1~100 20 * Startup ns P6.03 frequency 0.00Hz~10.00Hz 0.00Hz * Startup P6.04 frequency |0.0s~100.0s. 0.0s * holding time Startup DC braking current/ a P6.05 Pre-excited 10%~100% 0% * current Startup DC P6.06 | braking time/Pre-/0.0s~100.0s 0.0s * excited time 0: Straight-line acceleration/ " deceleration Acceleration/ i : 1: S curve acceleration/ P6.07 Peceleration dadaleration:A 0 * 2: Dynamic S curve acceleration/ deceleration 37 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property S curve of beginning a P6.08 segment time 10.0%~({100.0%-P6.09) 30.0% * proportional S curve of end P6.09 | segment time /0.0%~(100.0%-P6.08) 30.0% * proportional 0: Deceleration to stop P6.10 Stop mode 1: Coast to stop 0 * Initial frequency — P6.11 | ofstopDC _ |?.00kz~maximum o.00Hz | braking frequency Waiting time of P6.12 stop DC braking 0.0s~100.0s 0.0s * Stop DC braking | ,9, _. P6.13 current 0%~100% 0% * P6.14 | St0P DG braking |g o5~100.0s oos | P6.15 | Brakeuse rate |0%~100% 100% * Rotational speed at Model P6.18 tracking current 30%~200% dependent * Demagnetization Pé.21 time __|0.00-5.00s | (Valid for SVC) Pe 0: Not effective Over-excitation |1: Effective only when P6.23 selection deceleration 9 * 2: Effective always Over-excitation P6.24 suppression |0~150% 100% * current value Pe.zs | Oversartation /4.00~2.60 125 | 38 Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property Group P7 Operation display and Display ° No function 1: Switchover between operation panel command and remote operation command. It indicates the switchover| between the current command source and operation panel control (local operation). If the current command JOG function source is operation PHO parameter panel control, the key is 9 x invalid. 2: Switchover between forward and reverse through JOG, it only valid when command source is operation Panel channel. 3: Forward Jog (JOG-FWD) 4: Reverse Jog (JOG-REV) 0: STOP/RESET key enabled only in P7.02 STOP/RESET operation panel control . key function /1: STOP/RESET key enabled in any operation mode 39 Operation Instruction of SU800 Series Inverter Function code Parameter Name Setting range Default Property P7.03 LED display running Parameter 1 }0000~FFFF Bit00: Running frequency 1 (Hz) Bit01: Setting frequency (Hz) Bit02: Bus voltage (V) Bit03: Output voltage (V) Bit04: Output current (A) Bit05: Output power (kW) Bit06: Output torque (%) Bit07: S input status Bit08: MO1 output status Bit09: FIV/Voltage of potentiometer on operation panel (V) Bit10: FIC Voltage (V) Bit11: Reserved Bit12: Count value Bit13: Length value Bit14: Load speed display Bit15: PID setting 1F Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property }0000~FFFF Bit00: PID feedback Bit01: PLC stage Bit02: Pulse input frequency({kHz) Bit03: Running frequency 2 (Hz) Bit04: Remaining running time Bit05: Fiv/Voltage of potentiometer on operation panel before correction ) Bit06: FIC voltage before LED display correction (V) P7.04 running Bit07: Reserved 0 * parameter 2 | Bit08: Motor rotational speed Bit09: Current power-on time(Hour) Bit10: Current running time (Min) Bit11: Pulse input frequency(Hz) Bit12: Communication setting value Bit13: Speed feedback of Encoder(Hz) Bit14: Main frequency X display(Hz) Bit15:Auxiliary frequency Y display (Hz) 41 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property }0000~FFFF Bit00: Set frequency (Hz) Bit01: Bus voltage (V) Bit02: S input status Bit03: MO1 output status Bit04: FiV/Voltage of potentiometer on LED display stop) operation panel(V) PLoS parameter | Bit05: FIC voltage (V) al * Bit07: Count value Bit08: Length value Bit09: PLC stage Bit10: Load speed Bit11: PID setting Bit12: Pulse input frequency(kHz) Load speed o P7.06 display coefficient 0.0001~6.5000 1.0000 * Heatsink P7.07 | temperature of |0.0°C ~120.0°C - e inverter |IGBT ‘Group P8 Auxiliary Functions JOG running = |0.00Hz~maximum P8.00 frequency _|frequency 2.00Hz od paot | “OC mmnInG |o.05~6500.0s 20.08 | x |__| frequency ft pa.o2 | “PG Tunning |.05~6500.0s 2008 | x requency JOG running ~ Model P8.03 frequency 0.00s~65000s dependent * JOG running Model P8.04 frequency 0.0s~65000s dependent * JOG running Model P8.05 frequency 0.0s~65000s dependent * JOG running Model P8.06 frequency 0.0s~65000s dependent * JOG running Model P8.07 frequency 0.0s~65000s dependent * deceleration time Model P8.08 4 0.0s~65000s dependent * Jump frequency |0.00Hz~maximum P8.09 1 frequency 0.00Hz ve Jump frequency |0.00Hz~maximum P8.10 2 frequency 0.00Hz * 42 Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property Frequency jump |0.00Hz~maximum Pet amplitude frequency 0.00Hz * Forward/Reverse| P8.12 | rotation dead- |0.0s~3000.0s 0.0s * zone time P8.13__| Reverse control [0: Enabled 1: Disabled 0 * Running mode when set P8.14 | frequency lower than frequency lower limit 0: Run at frequency lower limit 1: Stop 2: Run at zero speed P8.15 | Droop control |0.00Hz~10.00Hz 0.00Hz * Accumulative P8.16 | power-on time |Oh~65000h Oh * threshold setting Accumulative P8.17 | running time /Oh~65000h Oh * threshold setting Startup 0: No protect Pa protection 1: Protect Frequency ccna P8.19 | detection value |[0-00H2-maximum or frequency 50.00Hz * Frequency detection 0.0%~100.0% hysteresis |(FDT1 level) (FDT1) P8.20 5.0% * Detection range P8.21 of frequency teached 0.0%~100.0% (maximum frequency) 0.0% * Jump frequency during the P8.22 process of acceleration/ deceleration 0: Disabled 1: Enabled Frequency switchover point between P8.25 acceleration oe maximum time 1 and any acceleration time 2 0.00Hz * 43 Operation Instruction of SU800 Series Inverter aaa Parameter Name Setting range Default |Property Frequency switchover point between ‘ P8.26 | deceleration aque 0.00Hz * time 1 and deceleration time 2 P8.27 Toate 0: Disabled 4:Enabled| 4 Frequency maxi P8.28 | detection value [Ook z=maximum 50.00Hz | (FDT2) _ [frequency Frequency detection 0.0%~100.0% P8.29 | hysteresis _|(FDT? level) soy) kK (FDT2) Any frequency i . Pe30 | reaching |innemum 50.00Hz | detection value 1 ey Any frequency reaching 0.0%~100.0% Poet detection (maximum frequency) 0.0% x amplitude 1 Any frequency ew Pesz | reaching |i 50.00Hz | x detection value 2 ey Any frequency reaching 0.0%~100.0% Pied detection (maximum frequency) a0 x amplitude 2 (0.0%-300.0% P|.s4 | Zoro.curent | 100.0% corresponding to | 6.0% | % rated motor current Zero current P8.35 | detection delay /0.01s~600.00s 0.10s * time 0.0% (no detection) P8.36 | Output over: |0.1%-300.0% (rated 200.0% | motor current) Output over- P8.37 | current detection |0.00s~600.00s 0.00s * delay time Any current —/0.0%~300.0% FESS reaching 1 (rated motor current) 100.0% x 44 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default |Property Any current " }0.0%~300.0% P8.39 reaching 1 0.0% x amplitude (rated motor current) Any current |0.0%~300.0% PB.40 reaching 2 _|(rated motor current) 100.0% * Any current a }0.0%~300.0% P8441 reaching 2 ( motor current) 0.0% * amplitude Timing function |0:Disabled P8.42 | “selection —_|1:Enabled 9 * 0: P8.44 1: FlV/potentiometer on operation panel Timing duration |2: FIC P8.43 ‘source 3: Reserved ° * 100% of analog input ‘corresponds to the value of P8.44, P8.44 | Timing duration |0.0Min~6500.0Min 0.0Min FIV input voltage P8.45, lower limit |0.00V~P8.46 3.10V protection value FIV input voltage P8.46 upper limit |P8.45~10.00V 6.80V * protection value Module P8.47 temperature |0°C ~100°C 75°C * threshold (0: Fan working during Cooling fan running Faas control 41: Fan working 5 x continuously Dormant frequency peg | Wakeup |(pg.51)~maximum o.oohz | * reauency | frequency (P0.10) paso | Wakeup delay |o o5-6500.0s oos | Dormant (0.00H2~wakeup frequency) P8.51 frequency _|(P8.49) 0.00Hz x pas2 | Dormant delay |9 o5~6500.0s oos | Current running at P8.53 time reached 0.0Min~6500.0Min 0.0Min. * 45 Operation Instruction of SU800 Series Inverter Function code Parameter Name Setting range Default Property P8.54 Output power correction coefficient 10~200% 100% P8.55 Emergency deceleration time 0~6553.5s. Model dependent Group P9: Fault and Protection P9.00 Motor overload protection selection 0: Disabled 1: Enabled P9.01 Motor overload protection gain 0.20~10.00 1.00 P9.02 Motor overload warning coefficient 50%~100% 80% P9.03 Over voltage stall gain 0~100 30 P9.04 Protection voltage of over voltage stall 120%~150% 130% P9.07 Short-circuit to ground upon power on 0: Disabled 1: Enabled P9.09 Fault auto reset times (0~20 P9.10 YO action selection during fault auto reset 0: No act 1: Act P9.11 Time interval of fault auto reset 0.1s~100.0s 1.0s P9.12 Input phase lost/ contactor suction protection selection Unit's digit: Input phase lost protection Ten’s digit: contactor ‘suction protection 0: disabled 1: enabled 00 P9.13 Output phase loss protection selection 0: Disabled 41: Enabled Unit's digit: output phase loss protection Ten’s digit: output phase loss protection before running Chapter 4 List of Function Parameters Function code Parameter Name Setting range Default Property P9.14 1st fault type 10: No fault 1: Reserved 2: Over-current during acceleration 3: Over-current during deceleration 4: Over-current at constant speed 5: Over-voltage during acceleration 6: Over-voltage during deceleration 7: Over-voltage at constant speed 8: Over-load of butter resistance 9: Under voltage 10:AC drive overload 11: Motor overload 12: Input Phase lost P9.15, 2nd fault type 13: Power output phase loss 14: Module overheat 15: External equipment fault 16: Communication fault 17: Contactor fault 18: Current detection fault 19: Motor auto-tuning fault 20: Encoder/PG card fault 21: Parameters read-write fault 22: AC drive hardware fault 23: Short circuit to ground 24: Reserved 25: Reserved 47 Operation Instruction of SU800 Series Inverter Function Pea Parameter Name Setting range Default Property ‘3rd (latest) fault P9.1 9.16 26:Running time reached 27: User-defined fault 1 28: User-defined fault 2 29: Power-on time reached 30: Load becoming 0 31: PID feedback lost during running 40: Fast limit overtime 41: Switchover motor when running 42: Speed deviation too large 43: Motor over speed 45: Motor over temperature 51: Initial position fault Group PA PID function PID setting PA.0O source 0: PA.O1 1: FlV/potentiometer on operation panel : FIC Reserved PULSE (S3, above 3.7kW) 5: Communication setting 6: Multi-reference PON PA.O1 | PID digit setting }0.0%~100.0% 50.0% PID feedback PA.02 ‘source 0: FlV/potentiometer on operation panel 41: FIC. 2: Reserved 3: FIV-FIC/ potentiometer on operation panel-FIC 4; PULSE (S3, above 3.7kW) 5: Communication setting 6: FIV+FIC/ potentiometer on operation panel +FIC 7: MAX (|FIV|, |FIC|)/ MAX (| potentiometer on operation panel |, |FIC|) 8: MIN (|FIV|, |FIC|)/ MIN (| potentiometer on operation panel |, |FIC|) 48 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default |Property PID action —_/0: Forward action PAS direction 1: Reverse action ® * PID setting PA.04 feedback range 0~65535 1000 * Pa.os | Proportional ge!" /o.0~100.0 200 | PA.06 | Integral time Ti1 |0.01s~10.00s 2.00s * paor | Piferential time /9 oo9s~10,0008 0.000s | x Cut-off frequency, PA.08 | of PID reverse |0.00~maximum frequency | 2.00Hz * rotation paog | PIP deviation lo 9%,~100.0% 0.0% | x Pato | PIP diferent lo o9%4~100.00% 0.10% | PID setting PA.11 change time 0.00~650.00s 0.00s * PID feedback PA12 filter time 0.00~60.00s 0.00s * pata | PID output fter |p 99-60.008 000s | x PA14 Reserved = - * pa.ts, |Proportional gain |o 9.499,0 20.0 | x PA.16_| Integral time Ti2 |0.01s~10.00s 2.00s * paar | Diferental time 9 oo0s~10.000s o.000s | 0: No switchover 1: Switchover via S terminal PID parameter " a & 2: Automatic switchover PA.18 switchover bi énidaviation 0 * condition 3: Automatic switchover based on running frequency PID parameter PA.19 switchover /0.0%~PA.20 20.0% * deviation 1 PID parameter PA.20 switchover /PA.19~100.0% 80.0% deviation 2 PA.21 | PID initial value |0.0%~100.0% 0.0% 49 Operation Instruction of SU800 Series Inverter Function Pea Parameter Name Setting range Default |Property Pa | ee ing time |0-00~650.008 000s | Unit's digit: Integral ‘separated 0: Invalid 4: Valid PID integral | Ten’s digit: Whether to PA25 property stop integral operation 00 x when the output reaches 0: Continue integral operation 1: Stop integral operation Detection value /0.0%: Not judging PA.26 | of PID feedback |feedback loss 0.0% | loss 0.1%~100.0% Detection time PA.27 | of PID feedback |0.0s~20.0s 0.0s * loss 0: No PID operation at Pa.2g | PID operation at stop 0 es P 4: PID operation at stop ‘Group PC Multi-Reference and Simple PLC Function Poop | Mul Rererence |. 199 9%4-~-100.0% 0.0% | Poot | MultiReference | 199 0%-100.0% 0.0% | Po.o2 | MultReference | 199 0%-~100.0% 0.0% | x Pc.o3 | MulthReference | 199 0%-~100.0% 0.0% | & Pc.og | MulthReference | 199 0%-~100.0% 0.0% | Po.os | MulReterence | 199.0% -~100.0% 0.0% | x Poo | Mul Reference | 199. 0%5-100.0% 0.0% | x Poor | MulKReference | 199 0%4-~-100.0% 0.0% | x Po.og | MulKReFerence | 199 0%4-~100.0% 0.0% | * Po.ag | MulKReFerence |. 199.0%4~100.0% 0.0% | 50 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default | Property po.to | MulKReference | 199 0%6-~-100.0% 00% | Pott | Mul Reference | 199 0%6-~-100.0% 00% | x po.rg | Mul Reference | 199. 0%4-~-100.0% 0.0% | po.rg | MulKReference | 199. 0%~100.0% 0.0% | po.14 | Mult Reference |. 109,0%6-100.0% 00% | po.ts | MulltReference | 199,0%6-100.0% 0.0% | & 0: Stop after the AC drive Tuns one cycle . 1: Keep final values after Simple PLC A PC.16 running mode the AC drive runs one 0 * cycle 2: Repeat after the AC drive runs one cycle Unit's digit: Retentive upon power failure Simple PLC |f: N°. PC.17 retentive sates licttbe " 00 * selection Ten’s digit: Retentive upon stop 0: No 1: Yes Running time PC.18 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) re teference 0 Acceleration/ deceleration time PC.19 | oF simple PLC |°~S 8 * reference 0 Running time PC.20 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * reference 1 Acceleration/ deceleration time PC.21 of simple PLC 0~3 0 * reference 1 Running time PC.22 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * reference 2 51 Operation Instruction of SU800 Series Inverter Function code Parameter Name Setting range Default Property PC.23 Acceleration/ deceleration time of simple PLC Teference 2 O~3 PC.24 Running time of simple PLC reference 3 0.0s(h)~6500.0s(h) 0.0s(h) PC.25 Acceleration/ deceleration time of simple PLC reference 3 PC.26 Running time of simple PLC Teference 4 0.0s(h)~6500.0s(h) 0.0s(h) PC.27 Acceleration/ deceleration time of simple PLC reference 4 PC.28 Running time of simple PLC teference 5 0.0s(h)~6500.0s(h) 0.0s(h) PC.29 Acceleration/ deceleration time of simple PLC reference 5 O~3 PC.30 Running time of simple PLC reference 6 0.0s(h)~6500.0s(h) 0.0s(h) PC.31 Acceleration/ deceleration time of simple PLC reference 6 PC.32 Running time of simple PLC reference 7 0.0s(h)~6500.0s(h) 0.0s(h) PC.33 Acceleration/ deceleration time of simple PLC teference 7 0~3 PC.34 Running time of simple PLC reference 8 0.0s(h)~6500.0s(h) 0.0s(h) 52 Chapter 4 List of Function Parameters Function Pea Parameter Name Setting range Default |Property Acceleration/ deceleration time of simple PLC Teference 8 PC.35 O~3 0 * Running time PC.36 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * reference 9 Acceleration/ deceleration time of simple PLC |°~S 9 * reference 9 PC.37 Running time PC.38 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) x teference 10 Acceleration/ deceleration time PC.39 of simple PLC 0~3 0 * reference 10 Running time PC.40 | ofsimple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * reference 11 Acceleration/ deceleration time of simple PLC [°° ° ¥ reference 11 PC.41 Running time PC.42 | of simple PLC /0.0s(h)~6500.0s(h) 0.0s(h) * reference 12 Acceleration/ deceleration time of simple PLC |°~9 ° * reference 12 PC.43 Running time PC.44 | of simple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * teference 13 Acceleration/ deceleration time PC.45 of simple PLC 0~3 0 * reference 13 Running time PC.46 | ofsimple PLC |0.0s(h)~6500.0s(h) 0.0s(h) * reference 14 53 Operation Instruction of SU800 Series Inverter Function Pea Parameter Name Setting range Default Property Acceleration/ deceleration time of simple PLC reference 14 PC.47 O~3 Running time of simple PLC reference 15 PC.48 0.0s(h)~6500.0s(h) 0.0s(h) Acceleration/ deceleration time of simple PLC reference 15 PC.49 O~3 Time unit of simple PLC running PC.50 0: s (second) +h (hour) Reference 0 PC.51 ‘@ourea, }: Set by PC.00 : FlV/Potentiometer on operation panel FIC Reserved PULSE PID Set by preset frequency (P0.08), UP/DOWN can be modified =el= Paren ‘Group PD: Communication Parameters PD.00 Baud rate Unit's digit! MODBUS 0: 300BPS 1: 600BPS 2: 1200BPS 3: 2400BPS 4: 4800BPS 5: 9600BPS 6: 19200BPS 7: 38400BPS 8: 57600BPS 9: 115200BPS Ten’s digit: Reserved Hundred’s digit Raseevie 0005 54 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default |Property (0: No check, <8-N-2> 1: Even parity check, <8- E-4> PD.O1 Data format 2: Odd Parity check, <8- 3 * }O-1> 3: 8-N-1 PD.02 | Local address |1~247 1 * PD.03 | Response delay |Oms~20ms 2 * Communication : PD.04 timeout 10.0 (Invalid), 0.1s~60.0s 0.0 x Unit's digit! MODBUS 0: Non-standard MODBUS Data transfer |protocol PD.05 | format selection |1: Standard MODBUS 1 * protocol Tens digit: Reserved Communication |, PD.06 | reading current |9° D-O*A 0 x resolution — Group PP: User-Defined Function Codes PP.0O0 | User password |0~65535 0 * 0: No operation Parameter |01: Restore factory Feel Initialization _| settings except motor 8 x parameters Group CO Torque control parameter Speed/Torque |. 0.00 | control mode ba Speed conte 0 * selection ilord 5s Operation Instruction of SU800 Series Inverter Function Pea Parameter Name Setting range Default Property Torque setting source selection in torque control mode 0.01 0: Digital setting 1 (C0.03) 1: FIV/ Potentiometer on operation panel 2: FIC 3: Reserved 4: PULSE 5: Communication setting 6: MIN (FIV,FICY MIN (Potentiometer on operation panel,FIC) 7: MAX (FIV,FICY MAX (Potentiometer on operation panel,FIC) (The full range of 1-7 corresponding to the digit setting of C0.03) Torque digit setting in torque control 0.03 }-200.0%~200.0% 150.0% Forward maximum frequency in torque control 0.05 (0.00Hz~maximum frequency 50.00Hz Reverse maximum frequency in torque control 0.06 0.00Hz~maximum frequency 50.00Hz Acceleration time| 0.07 in torque control 0.00s~65000s 0.00s Deceleration time C0.08 |; in torque control 0.00s~65000s 0.00s Group C5 Control optimizati ion parameters DPWM switchover frequency upper lirnit 5.00 0.00Hz~maximum frequency 8.00Hz PWM modulation 5.01 mode: 0: Asynchronous modulation 1: Synchronous modulation Dead zone 5.02 | compensation 10: No compensation 1: Compensation mode 1 mode selection 56 Chapter 4 List of Function Parameters aaa Parameter Name Setting range Default | Property (0: Random PWM invalid 5.03 | Random PWM 4-10: PWM carrier 0 x pt frequency random depth Rapid current |0: Disabled 05.04 limit __|1: Enabled 1 * Voltage over 5.05 modulation |100~110 105 * coefficient Under voltage C5.06 threshold setting 210~420 350 *« Dead zone time C5.08 adjustment 100%~200% 150% x Over voltage 7 Model 5.08 threshold setting 200. 0¥=2500.0¥ dependent Monitoring parameters: Function 7 Can Parameter Name Unit Group DO Basic monitoring parameters DO0.00 Running frequency (Hz) 0.01Hz DO0.01 Set frequency (Hz) 0.01Hz D0.02 Bus voltage (V) 0.1V D0.03 Output voltage (V) 4v D0.04 Output current (A) 0.01A DO0.05 Output power (kW) 0.1kW DO.06 Output torque (%) 0.1% DO0.07 S input status 1 DO0.08 MO1 output status 1 DO0.09 Potentiometer on operation panel/FIV Voltage (V) 0.01V DO.10 FIC Voltage (V) 0.01V DO.114 Reserved D0.12 Count value 1 DO.13 Length value 1 DO.14 Load speed display 1 DO.15 PID setting 41 37 Operation Instruction of SU800 Series Inverter Bonin Parameter Name Unit Code D016 PID feedback 1 DO.17 PLC stage 1 DO.18 PULSE input pulse frequency (kHz) 0.01kHz DO.19 Reserved DO.20 Remaining running time 0.1Min D0.21 Potentiometer on operation panel IFIV voltage before 0.001 correction DO.22 FIC voltage before correction 0.001V D0.23 Reserved D0.24 Linear speed 1m/Min DO.25 On the current power-on time 1Min D0.26 The current running time 0.1Min DO0.27 Input pulse frequency 1Hz D0.28 Communication setting value 0.01% DO.29 Reserved D0.30 Reserved DO.31 Auxiliary frequency Y display 0.01Hz DO.32 View any memory address values. 41 DO.33 Reserved D0.34 Motor temperature value rc DO0.35 Target torque (%) 0.1% DO0.36 Reserved 1 D0.37 Power factor angle 0.1° DO.38 Reserved 1 DO.39 Target voltage upon V/F separation 1Vv DBO.40 Output voltage upon V/F separation 1Vv DO0.41 Reserved D0.42 Reserved D0.43 Reserved D0.44 Reserved D0.45 Fault info 0 58 Chapter 4 List of Function Parameters BoD Parameter Name Unit Code D0.58 Z signal counter 1 DO.59 Set frequency (%) 0.01% DO.60 Running frequency (%) 0.01% DO.61 AC drive status 1 DO0.74 AC drive output torque 0.1 DO0.76 Accumulative power consumption low level 01°C DO0.77 Accumulative power consumption high level TC DO.78 Linear speed 4m/min Fault code list: Fault code Name Fault code Name Over current AL.02/0C1 during acceleration Over current i AL.03/002 during ALAGie, | Garrent defection 7 ult deceleration Over current , ‘AL.04/0C3 | during constant | ALtgrre _| Motor eule tuning speed Over voltage AL.O5/OU1 during acceleration Over voltage AL.06/OU2 during AL.21/EEP EEPROM read- deceleration Over voltage a AL.07/0U3 | during constant | AL.23/GND | Short circuit to ground fault speed Accumulative AL.O8/POFF ean aaa AL.26/END1 running time reached fault Under voltage Accumulative AL.O9/LU fault 9 AL.29/END2 power on time Teached fault AL10/0L2 |ACdrive overload) AL.sooap | Load evening o 59 Operation Instruction of SU800 Series Inverter Fault code Name Fault code Name PID feedback lost AL.11/0L4 Motor over load AL.31/PIOE during running fault AL21L1 | Input phase loss | AL4o/cBC | Rapid current limit Speed deviation ALA3/LO Output phase loss AL.42/ESP too large fault AL14/0H | Module overheat] AL.43/ogp | Motor over speed External ALASIEF equipment fault Communication AL.A6/CE fault We reserve the right of this manual contained information change without prior notice 2019.03

You might also like