10
u
12
13
LOADING PARAMETERS WITH AN PC (10,11,12,15 Controls)
Plug in Compatible PC into CD4A port on the Control
Tum on the Control
Use the same parameters that are used for loading part Programs
Use the same Communications program that is currently being used for loading
your ASCII file
Select the SETTING, CHAPTER, GENERAL
Set Parameter 8000 to all ones.
Place the contro! in E-STOP MODE.
Select the following soft keys in this order:
SERVICE
RIGHT SOFT KEY
READ
PARAMETER
The word READ will flash at the bottom of the screen.
‘Turn the computer on and start the communication program.
Start uploading the OPTION PARAMETER file from disk.
The message LOCKED PARAMETERS will appear.
‘Tum the control off and back on. Loading of the Parameters is now complete.
‘The parameter(s) is supplied on disk e.g. High speed skip option in Parameter 9100
N9100P00001000