LIST OF COMPONENTS:

Components Quantity
Compressed Air Supply 2
Air Service Unit, Simplified Representation 2
5/n Way Valve 3
One Way Flow Control Valve 6
Double Acting Cylinder 3
Electrical Connection 24V 1
Electrical Connection 0V 1
Detent Switch 1
Make Switch 15
Brake Switch 3
Relay with switch on delay 1
Relay 5
Valve Solenoid 6
Initial position of both pneumatic and electric circuits
When the switch is pushed, cylinder 1A starts to advance
When cylinder 1A is in fully advanced position, cylinder 2A also starts to advance.
When cylinder 2A is finally in fully advanced position, it is also the next cylinder to move or it will start
retracting back.
When cylinder 2A is in fully retracted position, it is both followed by cylinder 1A until it fully retracts and
cylinder 3A until it is in fully advanced position.
When cylinder 1A is in fully retracted position and when cylinder 3A is in fully advanced position,
cylinder 3A will also retract thereafter until it is fully retracted and is now back to the initial position of
the whole system.