You are on page 1of 233

NETWORK

SOLUTION
Product Catalogue
2019
About Us
Comba Telecom is a leading supplier of infrastructure and
wireless enhancement solutions to mobile operators and enter-
prises to enhance and extend their wireless communications
networks. Established in 1997, and listed on the Hong Kong Stock
Exchange in 2003, it has grown to become a global supplier with
its extensive distribution network and 60+ offices globally.

With seasoned team of research and development engineers and


its state-of-the-art design tools and testing equipment, Comba is
able to provide its innovative patented designs and yet cost-ef-
fective products to the customers. After working with Operators /
Private enterprise networks seamless all over the word for more
than 10 years, it is able to help the customers to roll out their full
scale range network quickly with the professional, customized,
quality guarantee product solutions.

Comba Network Solution Active DAS


Business Unit offers full range
of wireless enhancement
products, also Coverage Man-
agement System (CMS) for Wireless Repeater
wireless communication
network systems, which
include:
Public Safety Repeater

Small Cells

Coverage Management System

Comba is committed to quality consistency and environmental


protection and is ISO9001 and ISO14001 certified. With its highly
efficiency production lines in China and strict process control
system, Comba's manufacturing facility is able to deliver high
volume products with consistent quality.
Solution Overview
Comba’s wide range of indoor/outdoor repeater prod-
ucts provide total solutions for mobile network from
covering blind sports to implementing integrated cover-
age systems. The deployment of repeaters will effective-
ly optimized network efficiency by centralizing /
redirecting traffic capacity and enhancing power budget.

Compliant to all major technologies including GSM, CDMA, WCDMA, LTE, and Tetra.
Widely frequency range compliance e.g. 700MHz, 800MHz, 850MHz, 900MHz, 1800MHz, 1900MHz, AWS, 2100MHz,
2300MHz and 2600MHz.
Support multi-modulations and multi-operators applications so that providing cost-effective solutions.
Support various output power from 0.01 W to 40 W.
Wide range of product line that can be used from high-rise building to underground railway for all kinds of applications.

Product Overview
Comba DAS - ComFlex Series Overview

Highlight:
Max. 100W input power from BTS.
-163dBc PIM.
WEB GUI, RF routing and diagnosis function.
Max. supports 32 RF input and 32 RUs connection.
RU output power 1/2/5/10/20/40W.

Highlight:
Max. 100W input power from BTS.
-163dBc PIM.
WEB GUI, RF routing and diagnosis function.
Max. supports 32 RF input and 32 RUs connection.
Modular designed RU supports up to 8 bands,
20W per band without fan.

Highlight:
Max. 100W input power from BTS.
-163dBc PIM.
Supports flexible SISO & MIMO and multi-sector.
RU output power 1/2/5/10/20/40W.
WEB GUI.

Highlight:
Max. supports 8 RF input and 16 RUs.
Modular design easy for upgrade and maintenance.
Supports multi-operator input and each adjustable gain.
RU output power 1/2/5/10/20/40W.
WEB GUI, automatic calibration and commissioning.

Highlight:
Max. supports 8 RF input and 16 RUs.
Modular design easy for upgrade and maintenance.
Supports multi-operator input and each adjustable gain.
RU output power 1/2/5/10/20/40W.
WEB GUI, automatic calibration and commissioning.
Comba Wireless Repeater Series Overview

Wireless High Power R X S eries

Band S elective C hannel S elective


S eries S eries Public S afety
S eries

Highlight: Highlight: Highlight:


Support indoor/outdoor. Support indoor / outdoor. Support Class A and Class B.
4 Sub bands, 90 dB gain. Support ICS, 105 dB gain. Support AC and DC.
5/10/20W output power. 2/5/10/20W output power. Support 2W output power.
Support Dual/Tri Bands. Support Dual/Tri Bands. FCC/IC/UL/NEMA 4X certificated.

Wireless Medium Power mBDA Series

Indoor mBDA Series Outdoor mBDA Series

Highlight: Highlight:
Support indoor. Support outdoor.
3 Sub bands, 80 dB gain. 3 Sub bands, 80 dB gain.
0.5/1/2W output power. 0.5/1/2W output power.
Support up to 6 Bands. Support Dual/Tri Bands.

Wireless Low Power Pico Series

Single band mPico Multi-Band mPico

Highlight: Highlight:
Support indoor. Support indoor.
2 Sub bands, 75 dB gain. 2 Sub bands, 75 dB gain.
13/15/17dBm output power. 15/17dBm output power.
Support Single Band. Support Dual/Tri Bands.
Central Freq./ band width settable. Central Freq./ band width settable.
CMS Typical Network Management Diagram
Comba Base Station Series Overview
Indoor Base Station Solution

Highlight:
Support different scenarios application from hundreds to ten thousand square meters
Support different Single/Dual Band operation
Different output power level50mW/100mW/125mW and cascade networking

Outdoor Base Station Solution

Highlight: Highlight:
Support 4 Carriers (GSM/EDGE/GPRS). TDD/FDD & Customized Band Design
Support output power level up to80W 5MHz/10MHz/15MHz/20MHz bandwidth support.
Innovative IP-Based backhaul Support output power level up to 80W
Comba User Equipment Overview

Highlight: Highlight:
LTE Cat 4/6/12 LTE Cat4/6
High Antenna Gain Compact & Smart footprint
High Speed Data Rate Customized Band Available
Customized Band Available

Comba Core Network Series Overview

Highlight: Highlight: Highlight: Highlight:


All IP architecture X86 IT infrastructures
X86 IT infrastructures X86 IT infrastructures
X86 IT infrastructures Performance, Control,
Flexible configuration Mobile Edge
Support up to 20K Base High reliability ComputingSystem Alarm, Failure,
Stations Access
LIPA/SIPTO Management
High reliability Friendly GUI design
Wireless Enhancement Product Profile

DAS Series

Product Photo Name Power Bands System

700/800E/850/900/1800
1W
ComFlex /1900/AWS/2100/2300/ GSM/UMTS/
(Max.
MU 2600 LTE/CDMA
Input)
Max. 8

MU
700/800E/850/900/1800
100 W
ComFlex 1900/AWS/2100/2300/ GSM/UMTS/
(Max.
Plus ACU 2600 LTE/CDMA
Input)
Max. 32

700/800/850/900/1800/
Low Power 2/5W 1900/AWS/2100/2300/ GSM/UMTS/
RU (Output) 2600 LTE/CDMA
Max. 4

700/800/850/900/1800/
High Power 20/40W 1900/AWS/2100/2300/ GSM/UMTS/
RU RU (Output) 2600 LTE/CDMA
Max.4

700/800E/850/900/1800
/
10/20W GSM/UMTS/
Modular RU 1900/AWS/2100/2300/
(Output) LTE/CDMA
2600
Max. 8
Wireless Enhancement Product Profile

Wireless Repeater High Power RX Series

Product Photo Name Power Bands System

Band GSM/
800/850/900/1800/1900/
Selective RX-xx39 5/10W UMTS/
2100/2600
RX Series LTE/CMDA

Channel GSM/
5/10
Selective RX-xx23 800E/900/2100 UMTS/
/20W
RX Series LTE

Public Safety Series

Product Photo Name Power Bands System

BDA RX-7W22 2W 700/800 Tetra

DAS RH-7W22 2W 700/800 Tetra


Wireless Enhancement Product Profile

Wireless Repeater Medium Power mBDA Series

Product Photo Name Power Bands System

GSM/
mBDA 0.5/1/ 800E/850/900/1800/1900
mBDA-xx33 UMTS/
Outdoor 2W AWS/2100/2600
LTE/CDMA

GSM/
mBDA mBDA-RF- 0.5/1/ 800E/850/900/1800/1900
UMTS/
Indoor xx00 2W AWS/2100/2600
LTE/CDMA

Wireless Repeater Low Power Pico Series

Product Photo Name Power Bands System

Single GSM/
15/17/ 800/850/900/1800/1900/
Band MP-xx32 UMTS/
20dBm 2100/2600
mPico LTE/CDMA

Multi
GSM/
17/
Band MP-xx32 800/900/1800/2100 UMTS/
20dBm
LTE/CDMA
mPico
Wireless Access Product Profile

Small Cell Series

Product Photo Name Power Bands System

Home B3/B40
50mw
Small HNB-35,A01 FDD 1800 LTE
x2
Cell TDD 2300

B1/B3/B7/B40
Enterpri ENB-35L 125mw
FDD 2100/1800/2600 LTE
se Pico x2
TDD 2300

LTE B1/2/3/4
or
PolyCell 125mw LTE B2+UMTS B4 GSM/UMTS/
ENB-35xxx
1.0 x2 LTE B7+UMTS B1 LTE
or
LTE B3+GSM1800

Base Station Series


Product Photo Name Power Features System

Output Power 40W


GSM ENB-10, 4 Carriers, 1T2R
40W GSM
RRU A57R UL: 885-909 MHz
DL: 930-954 MHz
Output Power 2x40W
eNB-35A56R Single Carrier, 2T2R
LTE
eNB-35A57R 2x40W TDD 1447-1467MMH LTE
RRU
eNB-10A58R TDD: 1785-1805MHz
FDD LTE B3

4 GSM/EDGE/GPRS
GSM
ENB-10, A57 N/A Carriers GSM
BBU
Indoor/Outdoor Type

3GPP LTE R10


LTE
eNB-35A57 N/A Single LTE Carrier LTE
BBU
Indoor/Outdoor Type
Wireless Access Product Profile

CPE Series

Product Photo Name Category Features System

LTE FDD
B1/B3/B5/B7/B8/B20
LTE TDD B40 GSM/UMT
Indoor AP2600-IDU
CAT4 UMTS B1/B5/B8 S/
CPE ,A6
GSM LTE
850/900/1800/1900
Wi-Fi 2.4/5.8GHz

Outdoor AP2600-OP,
CAT4 LTE TDD B38/39/40/41 LTE
CPE A14

LTE FDD B2/3/7/28B


Outdoor AP2600-OP, LTE TDD B42
CAT6 LTE
CPE A10 2CC CA
Wireless Access Product Profile

Core Network

Product ICON Features System

COTS (X86) Server

EPC HSS,PCRF,S-GW,P-GW,MME LTE


1+1 redundancy, Pool
Flexible configuration for various users

COTS (X86) Server


Standard A, Gb interface to GSM Core
Gateway Standard S1 Interface to LTE Core GSM/LTE
Support Ipsec tunnel to different backhaul
Active/Standby redundancy

Network Management System


NMS Performance Management
GSM/LTE
Alarm Management
Configuration Management
Failure Management
Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides
effective coverage enhancement. The Comba product offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

2
Product application Scenario 1: Mega (>10,000 m )

Large Stadiums Shopping Mall

Product Recommend: Product Recommend:


DASComFlex AI DASComFlex CI
DASComFlex AM DASComFlex AI
Small Cell - PolyCell

Air Port Railway / Metro

Product Recommend: Product Recommend:


DASComFlex AI DASComFlex CM
DASComFlex AM DASComFlex AM
Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides
effective coverage enhancement. The Comba product offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Product application Scenario 2: Large (5,000 –10,000 m2)

Remote Village Campus

Product Recommend: Product Recommend:


Wireless RepeaterRX Series DAS ComFlex CI
Base Station Wireless RepeaterRX Series
Small Cell - PolyCell

Enterprise & Manufacture Residential

Product Recommend: Product Recommend:


Wireless RepeatermBDA Indoor Series DASComFlex CI
DASComFlex CI Small Cell- Enterprise PiCO
DASComFlex CM
Small Cell - PolyCell
Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides
effective coverage enhancement. The Comba product offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Product application Scenario 3: Medium (1,000 –5,000 m2)

Parking & Underground Tunnel

Product Recommend: Product Recommend:


DAS ComFlex CI DAS ComFlex CI
Wireless RepeaterRX Series DAS ComFlex CM
Wireless RepeaterRX Series

Park Supermarket

Product Recommend: Product Recommend:


Wireless RepeaterRX Series DAS ComFlex CI
Wireless RepeatermBDA Series Small Cell - PolyCell
Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides
effective coverage enhancement. The Comba product offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Product application Scenario 4: small (< 1,000 m2)

Retail Store Restaurant

Product Recommend: Product Recommend:


Wireless Repeater mBDA Series Wireless RepeatermBDA Series
Wireless RepeaterPico Wireless RepeaterPico
Small Cell –Enterprise Pico Small Cell –Enterprise Pico

Small Office Villa

Product Recommend: Product Recommend:


Wireless RepeatermBDA Series Wireless RepeatermBDA Series
Wireless RepeaterPico Wireless RepeaterPico
Small Cell –Enterprise Pico Small Cell –Home Small Cell
Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides
effective coverage enhancement. The Comba product offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Product application Scenario 5: Special Scenario1

Public Safety Bridge Coverage

Product Recommend: Product Recommend:

Wireless Repeater Public Safety Series Wireless Repeater mBDA Series

Small Cell –Enterprise Pico Wireless Repeater Pico Series

Highway Coverage Sail Coverage

Product Recommend:
Product Recommend:
Wireless RepeatermBDA Series
Wireless RepeatermBDA Series
Wireless Repeater Pico
Wireless Repeater Pico
Small Cell –Enterprise Pico
Index
ComFlex Series Distributed Antenna System............................................................................................22
ComFlex-5H00(CI) 1W2W..........................................................................................................23
ComFlex-5000(CI) 1W2W.......................................................................................................... 26
ComFlex-6100(CI) 1W................................................................................................................ 29
ComFlex-6800(CI) 20W40W......................................................................................................32
ComFlex-6900(CI)....................................................................................................................... 35
ComFlex-4500(CI) 2W5W.......................................................................................................... 38
ComFlex-4100(CI) 5W................................................................................................................ 41
ComFlex-5200(CI) 20W40W......................................................................................................44
ComFlex-5P00 (CI) 20W.............................................................................................................47
ComFlex-5000(CI) 20W40W......................................................................................................50
ComFlex-4300(CI) 40W.............................................................................................................. 53
ComFlex-4500(CI) 10W20W......................................................................................................56
ComFlex-4C00 (CI) 20W40W.................................................................................................... 59
ComFlex-4100(CI) 40W.............................................................................................................. 62
ComFlex CM 20W........................................................................................................................65
ComFlex CM 20W........................................................................................................................68
ComFlex-8A00 (CM) 20W.......................................................................................................... 71
ComFlex-8B00 (CM) 20W.......................................................................................................... 74
ComFlex-8C00 (CM) 20W.......................................................................................................... 78
ComFlex-5M00(AI) 10W20W.....................................................................................................81
ComFlex AM................................................................................................................................. 84
ComFlex-5900(AM) 20W............................................................................................................88
ComFlex-4100(AM) 20W............................................................................................................91
ComFlex-8A00 (AM) 20W.......................................................................................................... 94
RX Series Digital Band Selective Repeater................................................................................................98
RX-0739....................................................................................................................................... 100
RX-8132....................................................................................................................................... 101
RX-9139....................................................................................................................................... 102
RX-1823....................................................................................................................................... 103
RX-1839....................................................................................................................................... 105
RX-1939....................................................................................................................................... 106
RX-2139....................................................................................................................................... 107
RX-2620....................................................................................................................................... 108
RX-2623....................................................................................................................................... 109
RX Series Multi-band Digital Band Selective Repeater............................................................................111
RX-7137....................................................................................................................................... 114
RX-7539....................................................................................................................................... 116
RX-7639....................................................................................................................................... 118
RX-7839....................................................................................................................................... 120
RX-5239....................................................................................................................................... 122
RX Series Digital Channel Selective Repeater.........................................................................................124
RX-2123 III3.................................................................................................................................124
RX-0823....................................................................................................................................... 126
RX-0823....................................................................................................................................... 128
RX-2123 IV4................................................................................................................................ 129
RX-0823....................................................................................................................................... 132
RX-9123....................................................................................................................................... 133
RX-9123 IV4................................................................................................................................ 136
800MHz Tetra Band Selective Repeater...................................................................................................138
RX-8039....................................................................................................................................... 138
Critical Point™ Public Safety Bi-Directional Amplifier.............................................................................140
RX-7W22 Class A PS 700/800MHz BDA.............................................................................. 140
RX-7W22Class B PS 700/800MHz BDA............................................................................... 143
RX-4122 PS UHF 400MHz BDA..............................................................................................146
Critical Point™ Public Safety Distributed Antenna System..................................................................... 148
RH-7W22 PS 700/800MHz DAS..............................................................................................148
mBDA Series Digital Band Selective Repeater........................................................................................ 152
mBDA-0733.................................................................................................................................153
mBDA-9133.................................................................................................................................154
mBDA-1833.................................................................................................................................155
mBDA-1933.................................................................................................................................156
mBDA-2033.................................................................................................................................157
mBDA-2133.................................................................................................................................158
mBDA-2633.................................................................................................................................159
Combiner for Dual Single Band mBDAs..................................................................................................160
mBDA Indoor Digital Band Selective Repeater........................................................................................162
mBDA-100...................................................................................................................................162
mBDA-200S................................................................................................................................ 166
mBDA-200SS............................................................................................................................. 172
mBDA-300...................................................................................................................................178
MP Series Digital Pico Repeater..............................................................................................................184
MP-0832.......................................................................................................................................185
MP-8132.......................................................................................................................................186
MP-9132.......................................................................................................................................187
MP-1832.......................................................................................................................................188
MP-1932.......................................................................................................................................189
MP-2132.......................................................................................................................................190
MP-2632.......................................................................................................................................191
Multi-band Digital Pico Repeater.............................................................................................................192
Dual-band Digital Pico Repeater............................................................................................................. 193
MP-7V32...................................................................................................................................... 193
MP-7532.......................................................................................................................................195
Dual-band Digital Pico Repeater............................................................................................................. 197
MP-7632.......................................................................................................................................197
MP-7832.......................................................................................................................................199
Tri-band Digital Pico Repeater................................................................................................................ 200
MP-5K32...................................................................................................................................... 200
MP-5232.......................................................................................................................................201
MP-5832.......................................................................................................................................202
LTE1800 ICS Pico Repeater.....................................................................................................................203
SN-1823....................................................................................................................................... 203
Home Small Cell..................................................................................................................................... 206
HNB-35,A01................................................................................................................................ 206
Enterprise PiCO......................................................................................................................................208
ENB-35L...................................................................................................................................... 208
PolyCell Solution.................................................................................................................................... 210
DP (Distributed Point)............................................................................................................................. 212
CP (Center Point)....................................................................................................................................214
CK (Cell Kernel)...................................................................................................................................... 215
GSM IP-Base Station...............................................................................................................................216
RRU........................................................................................................................................................216
ENB-10, A57R............................................................................................................................ 217
BBU........................................................................................................................................................218
ENB-10, A57............................................................................................................................... 218
LTE eNodeB............................................................................................................................................219
Indoor CPE............................................................................................................................................. 222
AP2600-IDU, A06.......................................................................................................................222
Outdoor CPE.......................................................................................................................................... 223
AP2600-OP, A14.........................................................................................................................223
CP2600-OP, A10.........................................................................................................................224
Comba EPC System................................................................................................................................226
Gateway................................................................................................................................................. 228
Coverage Management System.............................................................................................................. 230
CMS V8.2.....................................................................................................................................230
 ComFlex DAS Series

Page 24 of 234
ComFlex Series Distributed Antenna System
ComFlex-5H00(CI) 1W2W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and low power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation; it is an integrated design which supports 3 independent bands,
850MHz, 1900MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 23 of 232
Specifications
Optical
System 850MHz, 1900MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3-5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
8 (16 with FOU extension)
Unit

Electrical
850MHz 1900MHz 2600MHz
Uplink Frequency Range 824-849 1850-1910 2500-2570
MHz
Downlink Frequency Range 869-894 1930-1990 2620-2690
Operating Bandwidth MHz 25 60 70
Uplink Output Power dBm -25 -25 -25
Downlink Output Power dBm 30/33 30/33 30/33

Uplink Maximum gain dB 20 @ 1W; 23 @ 2W


Downlink Maximum gain dB 20 @ 1W; 23 @ 2W
ATT Adjustable Range(1dB step) dB MU: 0-40; RU: 0-15
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 24 of 232
Specifications
Mechanical---LRU
1W 2W
Dimensions, H x W x D mm 680 x 260 x 180

Weight kg 25

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption W 120 150

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 25 of 232
ComFlex Series Distributed Antenna System
ComFlex-5000(CI) 1W2W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and low power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation; it is an integrated design which supports 3 independent bands,
1900MHz, AWS and AWS MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 26 of 232
Specifications
Optical
1900MHz, AWS, AWS
System
MIMO
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM


Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3to5
Optical Return Loss dB >50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors SC/APC

Maximum Remote Unit per Master Unit 4 (8 with FOU extension)

Electrical
1900MHz AWS AWS MIMO
Uplink Frequency Range 1850-1910 1710-1755 1710-1755
MHz
Downlink Frequency Range 1930-1990 2110-2155 2110-2155
Operating Bandwidth MHz 60 45 45
Uplink Output Power dBm -25 -25 -25
Downlink Output Power dBm 30/33 30/33 30/33

Uplink Maximum gain dB 20 @ 1W; 23 @ 2W

Downlink Maximum gain dB 20 @ 1W; 23 @ 2W

ATT Adjustable Range(1dB step) dB MU: 0-40; RU: 0-15


Pass Band Ripple (p-p) dB ≤6 ≤6 ≤6
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Page 27 of 232
Mechanical---MU
Chassis 178 x 482x 360

Fiber Optical Unit 37 x 185 x 299


Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259

Power Supply Unit 140 x 63 x 400

Chassis 12

Fiber Optical Unit 2


Weight (approx.) kg
Per RF Unit 1

Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---LRU

1W 2W
Dimensions, H x W x D mm 680 x 260 x 180

Weight kg 25

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption W 120 150

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 28 of 232
ComFlex 600 Series DAS
ComFlex-6100(CI) 1W
Features

 Industry’s first DAS system with superior PIM performance MINI-DIN RF connectors.
 Independent coupling port for uninterrupted network testing.
 Modular Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact, slim Remote Unit for OPEX saving.
 Supports multi-operator and mixed mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex 600 series Distributed Antenna System is an RF over fiber solution that enhances a
wireless network’s coverage by extending cellular services from existing cell sites to an indoor
environment. The system consists of the Master Unit (MU) and Low power Remote Unit (RU). The MU
includes the Chassis, Power Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a
modular design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is
designed with a compact and slim form factor for easy installation; it is an integrated design which
supports 6 independent bands: 700MHz (lower ABC), 700MHz (upper C),800MHz, 850MHz, 1900MHz,
and AWS band.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Hex-Band DAS offers service providers an optimal solution for
variable venue sizes such as single buildings, office campuses, megamalls and sports arenas.

Functional Block Diagram

Page 29 of 232
Specifications
Optical
700MHz (lower ABC), 700MHz (upper C), 800MHz, 850MHz, 1900MHz,
System
AWS
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3-5
Optical Return Loss dB > 50

Max. Optical Loss dBo 6.5


Optical Automatic Gain Control dBo 6.5

Fiber Connectors SC/APC


Maximum Remote Unit per Master
8 (16 with FOU extension)
Unit

Electrical
700MHz 800/850MHz 1900MHz AWS
Uplink Frequency Range 698-716/776-787 817-824/824-849 1850-1915 1710-1755
Downlink Frequency MHz
728-746/746-757 862-869/869-894 1930-1995 2110-2155
Range
Operating Bandwidth MHz 18/11 7/25 65 45
Uplink Output Power dBm -25 -25 -25 -25
Downlink Output Power dBm 30 30 30 30
Uplink Maximum Gain dB 20
Downlink Maximum Gain dB 20
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤4 ≤6 ≤6 ≤4
3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106 3GPP TS 25.106
Spurious Emission 3GPP TS 36.106
FCC FCC FCC
FCC
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Page 30 of 232
Specifications
Mechanical---MU
Chassis 7” x 19” x 15.7” (178 x 482x 400)

Fiber Optical Unit 1.5” x 7.3” x 11.8” (37 x 185 x 299)


Dimensions, H x W x D in(mm)
Per RF Unit 4.1” x 1.8” x 10.2” (103 x 46 x 259)

Power Supply Unit 5.5” x 2.5” x 15.7” (140 x 63 x 400)

Chassis 24.3 (11)

Fiber Optical Unit 4.4 (2)


Weight (approx.) lb(kg)
Per RF Unit 2.2 (1)

Power Supply Unit 5.5 (2.5)

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors Mini DIN-Female


QMA-Female
Coupling Port Connectors
(For UL related testing, coupling value: -5dB)
Fiber Connectors SC/APC

Operating Temperature °C 0 to 40

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
Remote Unit 23.6” x 9.8” x 5.9” (600 x 250 x 150)
Dimensions, H x W x D in(mm)
Power Supply Unit 16.1” x 4.4” x 3.5” (408 x 111 x 90)
Remote Unit 44.1 (20)
Weight (approx.) lb(kg)
Power Supply Unit 7.7 (3.5)
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 120
RF Connectors Mini DIN-Female
QMA-Female
Coupling Port Connectors (For DL related testing, coupling value: -45dB:700&850&800;
-35dB:1900&AWS)
QMA-Female
RF Expansion Port
(1 x TX_EXT + 1 x RX_EXT)
Fiber Connectors SC/APC
Operating Temperature °C -20 to 50
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type Wall and Pole

Page 31 of 232
ComFlex Series Distributed Antenna System
ComFlex-6800(CI) 20W40W
Features

 Independent coupling port for uninterrupted networktesting.


 Independent coupling port for uninterrupted networktesting.
 Independent gain control for each RFsource.
 High MTBF and low noise design with modular PSU and convectioncooling.
 RF module supports both simplex andduplex.
 IP65 weatherproof RU with built-in surgeprotector.
 Supports multi-operator and mix modeapplication.
 Optical link auto gaincontrol.
 Web based GUI for intelligent commissioning andconfiguration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and
scalable solution of multi-band, multi-operator coverage extension applications, such as citywide
enhancement, highway, canyons, campus, underground tunnels, airports, convention centers, etc.

Functional Block Diagram

Page 32 of 232
Specifications
Optical
System 700MHz, 800MHz, 850MHz, 1900MHz, AWS1+AWS3
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3-5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
16 (with FOU extension)
Unit

Electrical
700MHz 800/850MHz 1900MHz AWS1+AWS3
Uplink Frequency Range 698-716/776-787 817-824/824-849 1850-1915 1710-1780
Downlink Frequency MHz
728-757 862-869/869-894 1930-1995 2110-2180
Range
Operating Bandwidth MHz 18/11 7/25 65 70
Downlink Output Power dBm 43/46 43/46 43/46 43/46
Uplink Maximum Gain dB 33
Downlink Maximum Gain dB 36
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤6 ≤6
3GPP TS 25.106
Spurious Emission 3GPP TS 36.106 3GPP TS25.106 3GPP TS 25.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 178 x 482 x 360

Fiber Optical Unit 37 x 185 x 299


Dimensions, H x W x D in(mm)
Per RF Unit 103 x 46 x 259

Power Supply Unit 140 x 63 x 400

Chassis 12

Fiber Optical Unit 2


Weight (approx.) lb(kg)
Per RF Unit 1

Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz


Power Consumption (approx.) W 85
RF Connectors Mini DIN-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to 40
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 33 of 232
Specifications
Mechanical---HRU
Dimensions, H x W x D mm 1350 x 315 x 225

Weight (approx.) kg 70

AC110/220V VAC 100-240/47/63Hz


Power Supply
DC-48 VDC -58 to -40

Power Consumption (approx.) W 1350

RF Connectors DIN-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +70

Operating Humidity ≤ 95%

Ingress Protection IP65

Enclosure Cooling Fan

Installation Type Wall and Pole

Page 34 of 232
ComFlex Series Distributed Antenna System
ComFlex-6900(CI)
Features

 Independent coupling port for uninterrupted network testing.


 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and
scalable solution of multi-band, multi-operator coverage extension applications, such as citywide
enhancement, highway, canyons, campus, underground tunnels, airports, convention centers, etc.

Functional Block Diagram

Page 35 of 232
Specifications
Optical
System 2300MHz, 2300MIMO, 2500MHz, 2500MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 2.5 to 4
Optical Return Loss dB >50
Max. Optical Loss dB 8
Optical Automatic Gain Control dB -2 to -10
Fiber Connectors SC/APC
Maximum Remote Unit per Master
8 (with FOU extension)
Unit

Electrical
2300MHz 2300MIMO 2500MHz 2500MIMO
Uplink Frequency Range 2305-2315 2305-2315 2496-2690 2496-2690
MHz
Downlink Frequency Range 2350-2360 2350-2360 2496-2690 2496-2690
3, 5, 10, 15, and 3, 5, 10, 15, and
Operating Bandwidth MHz 3, 5, and 10 3, 5, 10
20 20
Downlink Output Power dBm 46 46 46 46
Uplink Maximum gain dB 30
Downlink Maximum gain dB 36
ATT Adjustable Range(1dB
dB 0-30
step)
Pass Band Ripple (p-p) dB ≤4 ≤4 ≤6 ≤6
3GPP TS 3GPP TS
Spurious emission 3GPP TS36.106 3GPP TS 36.106
36.106 36.106
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤ 3.5
VSWR ≤ 1.5
Max. Input RF Power at Master
dBm 30
Unit

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240; 50/60Hz
Power Consumption (approx.) W 85
RF Connectors 4.3-10
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 36 of 232
Specifications
Mechanical---HRU
40W
Dimensions, H x W x D mm 1350 x 315 x 225

Weight (approx.) kg 70

AC110/220V VAC 100-240; 47/63Hz


Power Supply
DC-48 VDC -68 to -40

Power Consumption (approx.) W 1100

RF Connectors DIN-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +70

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 37 of 232
ComFlex Series Distributed Antenna System
ComFlex-4500(CI) 2W5W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and medium power Remote Unit (RU). The MU includes the
Chassis, Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design,
it can support up to8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a
compact and slim form factor for easy installation; it is an integrated design which supports 4
independent bands,900MHz, 1800MHz, 2100MHz and 1800MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Quad-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 38 of 232
Specifications
Optical
System 850MHz, 1800MHz, 2100MHz, 2600MHz

Optical Fiber Single Mode


Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3 to 5

Optical Return Loss dB >50


Max. Optical Loss dBo 6.5

Optical Automatic Gain Control dBo 6.5

Fiber Connectors SC/APC


Maximum Remote Unit per Master
8 (16 with FOU expansion)
Unit

Electrical
850MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 824-849 1710-1785 1920-1980 2500-2570
Downlink Frequency MHz
869-894 1805-1880 2110-2170 2620-2690
Range
Operating Bandwidth MHz 25 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 33/37 33/37 33/37 33/37
Uplink Maximum gain dB 23@2W, 27@5W
Downlink Maximum gain dB 23@2W, 27@5W
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤4 ≤5 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit
MTBF hr >100,000

Page 39 of 232
Mechanical---MU
Chassis 178 x 482x 360

Fiber Optical Unit 37 x 185 x 299


Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259

Power Supply Unit 140 x 63 x 400

Chassis 11

Fiber Optical Unit 2


Weight (approx.) kg
Per RF Unit 1

Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Specifications
Mechanical---MRU 2W 5W
Remote Unit 660 x 250 x 160
Dimensions, H x W x D mm
Power Supply Unit 408 x 111 x 90

Remote Unit 25
Weight (approx.) kg
Power Supply Unit 3.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 180 200

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C -20 to +50

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type Wall/Pole

Page 40 of 232
ComFlex Series Distributed Antenna System
ComFlex-4100(CI) 5W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and medium power Remote Unit (RU). The MU includes the
Chassis, Power Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design,
it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a
compact and slim form factor for easy installation; it is an integrated design which supports 4
independent bands900MHz, 1800MHz, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for variable venue
sizes such as single buildings, office campuses, mega malls and sports arenas.

Functional Block Diagram

Page 41 of 232
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3 to 5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
16 (with FOU extension)
Unit

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 35 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 37 37 37 37

Uplink Maximum gain dB 27


Downlink Maximum gain dB 27
ATT Adjustable Range (1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤6
3GPP
3GPP TS25.106 TS25.106 3GPP
Spurious emission 3GPP TS 36.106
3GPP TS 36.106 3GPP TS TS25.106
36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at Master
dBm 30
Unit

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 42 of 232
Specifications
Mechanical---MRU
Remote Unit 660 x 250 x 160
Dimensions, H x W x D mm
Power Supply Unit 408 x 111 x 90

Remote Unit 25
Weight (approx.) kg
Power Supply Unit 3.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 200

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C -20 to +50

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type Wall/Pole

License Note
License Code 900MHz 1800MHz 2100MHz 2600MHz
N/A √ √ √ √

Page 43 of 232
ComFlex Series Distributed Antenna System
ComFlex-5200(CI) 20W40W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 High MTBF with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Independent coupling port of MU for uninterrupted network testing.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and Remote Unit (RU). The MU includes the MU Rack, Power
Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up
to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact and slim
form factor for easy installation; it is an integrated design which supports 3 independent bands, 900MH,
1800MHz and 2100MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 44 of 232
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3-5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC

Electrical
900MHz 1800MHz 2100MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170
Operating Bandwidth MHz 35 75 60
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35@20W, 38@40W
ATT Adjustable Range(1dB step) dB MU: 0-40, RU: 0-30
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
3GPP TS 25.106
Spurious emission 3GPP TS 25.106 3GPP TS 25.106
3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master
dBm 30
Unit

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 45 of 232
Specifications
Mechanical---HRU
20W 40W
Dimensions, H x W x D mm 1270 x 236x 236

Weight (approx.) kg 49

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1000 1200

RF Connectors 3 x 7/16 DIN-F

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 46 of 232
ComFlex Series Distributed Antenna System
ComFlex-5P00 (CI) 20W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 High MTBF with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Independent coupling port of MU for uninterrupted network testing.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and Remote Unit (RU). The MU includes the MU Rack, Power
Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up
to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact and slim
form factor for easy installation; it is an integrated design which supports 3 independent bands, 1800MH,
2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 47 of 232
Specifications
Optical
System 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3.0 to 5.0
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
16 (with FOU extension)
Unit

Electrical
1800MHz 2100MHz 2600MHz
Uplink Frequency Range 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 75 60 70
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43 43 43
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35
ATT Adjustable Range(1dB step) dB MU: 0-40; RU: 0-30
Pass Band Ripple (p-p) dB ≤6 ≤6 ≤6
Spurious emission 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master
dBm 30
Unit

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 48 of 232
Specifications
Mechanical---HRU
20W
Dimensions, H x W x D mm 1270 x 236 x 236

Weight (approx.) kg 49

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 1100

RF Connectors Din-Female (1 x TX and 1 x RX)

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 49 of 232
ComFlex Series Distributed Antenna System
ComFlex-5000(CI) 20W40W
Features

 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation; it is an integrated design which supports 3 independent bands,
1900MHz, AWS, and AWS MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 50 of 232
Specifications
Optical
System 1900MHz, AWS, AWS
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3.0 to5.0
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
4 (8 with FOU extension)
Unit

Electrical
1900MHz AWS AWS
Uplink Frequency Range 1850-1910 1710-1755 1710-1755
MHz
Downlink Frequency Range 1930-1990 2110-2155 2110-2155
Operating Bandwidth MHz 60 45 45
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46

Uplink Maximum gain dB 33


Downlink Maximum gain dB 35 @ 20W; 38 @ 40W
ATT Adjustable Range(1dB
dB MU: 0-40; HRU: 0-30
step)
Pass Band Ripple (p-p) dB ≤6 ≤5 ≤5
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 51 of 232
Specifications
Mechanical---HRU
20W 40W
Dimensions, H x W x D mm 1270 x 236 x 236

Weight (appr.) kg 49

AC110/220V VAC 100-240/50-60Hz


Power Supply
DC-48 VDC -40 to -58

Power Consumption (appr.) W 1100 1250

RF Connectors D-Female x 3

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall/Pole

Page 52 of 232
ComFlex Series Distributed Antenna System
ComFlex-4300(CI) 40W
Features

 Modularized Master Unit supports flexible field upgrade and maintenance.


 Independent gain control for each RFsource.
 RF module supports both simplex and duplex.
 Independent coupling port for uninterrupted network testing.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and High power Remote Unit (RU). The MU includes the
Chassis, Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design,
it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a
compact and slim form factor for easy installation; it is an integrated design which supports 4
independent bands, 700MHz (lower ABC & upper C), 850MHz, 1900MHz and AWS band.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba Quad-Band DAS offers service providers an optimal solution for
multiple applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 53 of 232
Specifications
Optical
System 700MHz, 850MHz, 1900MHz, AWS
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 2.5to4.0
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Maximum Remote Unit per Master
8
Unit

Electrical
700MHz 850MHz 1900MHz AWS
Uplink Frequency Range 698-716/776-787 824-849 1850-1915 1710-1755
Downlink Frequency MHz
776-787 869-894 1930-1995 2110-2155
Range
Operating Bandwidth MHz 18/11 25 65 45
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 46 46 46 46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 36
ATT Adjustable Range(1dB
dB MU: 0-20, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤6 ≤5
Spurious emission 3GPP TS 36.106 FCC FCC FCC
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 7” x 19” x 15.7” (178 x 482 x 400)
Fiber Optical Unit 1.5” x 7.3” x 11.8” (37 x 185 x 299)
Dimensions, H x W x D mm
per RF Unit 4.1” x 1.8” x 10.2” (103 x 46 x 259)
Power Supply Unit 5.5” x 2.5” x 15.7” (140 x 63 x 400)
Chassis 24.3 (11)
Fiber Optical Unit 4.4 (2)
Weight (approx.) kg
Per RF Unit 2.2 (1)

Power Supply Unit 5.5 (2.5)


Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors mini-Din - Female
QMA – Female
Coupling port connectors
(For UL related testing, coupling value: -5dB)
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 54 of 232
Specifications
Mechanical Specifications--HRU
53.1” x 8.9” x 12.4”
Dimensions, H x W x D Remote Unit in(mm)
1350 x 225 x 315
Weight (approx.) Remote Unit lb(kg) 154.3(70)
AC110/220V VAC 100 – 240 / 47 – 63Hz
Power Supply VD
DC-48 -58 – -40
C
Power Consumption (approx.) W 1350
RF Connectors DIN – Female
Fiber Connectors SC/APC
Operating Temperature °C -40 – +70
Operating Humidity % ≤ 95
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall / Pole

Ordering Information
Module Name P/N
Master Unit Chassis MU01-RACK-E01

Master Unit Power Supply Unit MU01-PSU-A92W300

Master Unit Fiber Optical Unit MU01-FOU-SABFOP6ED4

Master Unit RF Unit (700 Upper C) MU01-RFU-0700B11D


MU
Master Unit RF Unit (700 Lower ABC) MU01-RFU-0700B181D

Master Unit RF Unit (850MHz) MU01-RFU-0850B25D


Master Unit RF Unit (1900MHz) MU01-RFU-1900B65D

Master Unit RF Unit (AWS band) MU01-RFU-2000B45D


High Power Remote Unit
RU HRU01-4300QB004QP02A92OP4
(700+800/850+1900+AWS)

Page 55 of 232
ComFlex Series Distributed Antenna System
ComFlex-4500(CI) 10W20W
Features

 Independent coupling port for uninterrupted network testing.


 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation; it is an integrated design which supports 4 independent bands,
850MHz, 1800MHz, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and
scalable solution of multi-band, multi-operator coverage extension applications, such as citywide
enhancement, highway, canyons, campus, underground tunnels, airports, convention centres, etc.

Functional Block Diagram

Page 56 of 232
Specifications
Optical
System 850MHz, 180MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3to5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
8 (16 with FOU extension)
Unit

Electrical
850MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 824-849 1710-1785 1920-1980 2500-2570
Downlink Frequency MHz
869-894 1805-1880 2110-2170 2620-2690
Range
Operating Bandwidth MHz 25 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 40/43 40/43 40/43 40/43
Uplink Maximum gain dB 32@10W, 33 @20W
Downlink Maximum gain dB 32@10W, 35 @20W
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6 ≤6
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit
MTBF hr >100,000

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 57 of 232
Specifications
Mechanical---RU
10W 20W
Dimensions, H x W x D mm 1350 x 315 x 225

Weight (approx.) kg 70

AC110/220V VAC 100-240/50-60Hz


Power Supply
DC-48 VDC -40 to -58

Power Consumption (approx.) W 850 1100

RF Connectors DIN-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +70

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 58 of 232
ComFlex Series Distributed Antenna System
ComFlex-4C00 (CI) 20W40W
Features

 Modularized Master Unit supportsflexible field upgrade and maintenance.


 Independent gain control for each RF source.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU expansion.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and High power Remote Unit (RU). The MU includes the
Chassis, Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design,
it can support up to8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a
compact and slim form factor for easy installation; it is an integrated design which supports 4
independent bands, 850MHz, 1900MHz, AWS and AWSMIMO band.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 59 of 232
Specifications
Optical
System 850MHz, 1900MHz, AWS, AWS MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output
Remote dBm
Power 3.0 to 5.0
Unit
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Maximum Remote Unit per Master
4 (8 with FOU extension)
Unit

Electrical
850MHz 1900MHz AWS AWS
Uplink Frequency Range 824-849 1850-1910 1710-1755 1710-1755
Downlink Frequency MHz
869-894 1930-1990 2110-2155 2110-2155
Range
Operating Bandwidth MHz 25 60 45 45
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46 43/46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35@ 20W, 38@40W
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max Downlink Input
dBm 30
Power

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to 40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 60 of 232
Specifications
Mechanical---HRU
Dimensions, H x W x D mm 1350 x 225 x 315

Weight (approx.) kg 70

AC110/220V VAC 100-240/47-63Hz


Power Supply
DC-48 VDC -58 to-40

Power Consumption (approx.) W 1350

RF Connectors DIN-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +70

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 61 of 232
ComFlex Series Distributed Antenna System
ComFlex-4100(CI) 40W
Features

 Independent coupling port for uninterrupted network testing.


 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
and slim form factor for easy installation; it is an integrated design which supports 4 independent bands,
850MHz, 1800MHz, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and
scalable solution of multi-band, multi-operator coverage extension applications, such as citywide
enhancement, highway, canyons, campus, underground tunnels, airports, convention centres, etc.

Functional Block Diagram

Page 62 of 232
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3to5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master
8 (16 with FOU extension)
Unit

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
Downlink Frequency MHz
925-960 1805-1880 2110-2170 2620-2690
Range
Operating Bandwidth MHz 35 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 46 46 46 43
Uplink Maximum gain dB 38
Downlink Maximum gain dB 38
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 178 x 482x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 360
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
Operating Temperature °C 0 to+40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Page 63 of 232
Specifications
Mechanical---HRU
40W
Dimensions, H x W x D mm 1350 x 315 x 225

Weight (approx.) kg 70

AC110/220V VAC 100-240/50-60Hz


Power Supply
DC-48 VDC -40 to -58

Power Consumption (approx.) W 1350

RF Connectors DIN-Female

Fiber Connectors SC/APC

Operating Temperature °C -40 to +70

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 64 of 232
ComFlex Series Distributed Antenna System
ComFlex CM 20W
Features

 Modularized Master Unit and Remote Unit support field upgrade andindependent gain control.
 RF module supports both simplex/duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, LTE
 Comply with 3GPP and supports LTEMIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU/PA/optical backup (conditional) and white optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
form factor for easy installation, and its modular design is easy for upgrading and maintenance, which
supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 65 of 232
Specifications
Optical
System 700MHz, 850MHz, 900MHz, 1800MHz, 2100MHz,2300MHz,2600MHz

Optical Fiber Single Mode


Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to 2


dBm
Power Remote Unit 3.0to5.0

Optical Return Loss dB >50


Max. Optical Loss dB 6.5

Optical Automatic Gain Control dB 6.5

Fiber Connectors MU:SC/APC; RU:FC/APC


Maximum Remote Unit per Master
8 (16 with FOU extension) in SISO; 4 (8 with FOU extension) in MIMO
Unit

Electrical
700 850 900 1800 2100 2300 2600
MHz MHz* MHz* MHz MHz MHz MHz
Uplink Frequency 1710-178 1920-198 2300-240 2500-257
703-748 824-849 880-915
Range 5 0 0 0
MHz
Downlink 1805-188 2110-217 2300-240 2620-269
758-803 869-894 925-960
Frequency Range 0 0 0 0
Operating
MHz 45 25 35 75 60 100 70
Bandwidth
Uplink Output -30 -30 -30 -30 -30
dBm -30 -30
Power
Downlink Output 43 43 43 43 43
dBm 43 43
Power
Uplink Maximum
dB 30
gain
Downlink Maximum
dB 35
gain
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple
dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP TS 3GPP TS
3GPP TS 3GPP TS 25.106 25.106 3GPP TS 3GPP TS 3GPP TS
Spurious emission
36.106 25.106 3GPP TS 3GPP TS 25.106 36.106 36.106
36.106 36.106
Uplink Noise Figure
dB ≤5
at Maximum Gain
se
System Delay ≤2
c
VSWR ≤ 1.5
Max Downlink Input
dBm 30
Power
* Note: 850MHz and 900MHz can’t be used together unless there is at least 5MHz frequency interval.

Page 66 of 232
Specifications
Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400

Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
CMU 528 x 298 x 251

Dimensions, H x W x D Per RF Unit mm 528 x 290 x 152

Mounting Rack 602 x 820 x 80

CMU 25

Weight (approx.) Per RF Unit kg 15

Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200 (8 bands)

RF Connectors N-Female

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 67 of 232
ComFlex Series Distributed Antenna System
ComFlex CM 20W
Features

 Modularized Master Unit and Remote Unit support field upgrade andindependent gain control.
 RF module supports both simplex/duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, LTE.
 Comply with 3GPP and supports LTEMIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU\PA\optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
form factor for easy installation, and its modular design is easy for upgrading and maintenance, which
supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 68 of 232
Specifications
Optical
700MHz, 800MHz, 850MHz, 1800MHz, 1900MHz,
System
2100MHz,AWS,2600MHz
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to 2


dBm
Power Remote Unit 3.0to5.0
Optical Return Loss dB >50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors MU:SC/APC; RU:FC/APC


Maximum Remote Unit per Master
8 (16 with FOU extension) in SISO; 4 (8 with FOU extension) in MIMO
Unit

Electrical
700 800 850 1800 1900 2100 2600
AWS**
MHz MHz* MHz* MHz** MHz** MHz** MHz
Uplink Frequency 1710-17 1850-19 1920-19 1710-175 2500-25
703-748 806-824 824-849
Range 85 10 80 5 70
MHz
Downlink 1805-18 1930-19 2110-21 2110-215 2620-26
758-803 851-869 869-894
Frequency Range 80 90 70 5 90
Operating
MHz 45 18 25 75 60 60 45 70
Bandwidth
Uplink Output -30 -30 -30 -30 -30 -30
dBm -30 -30
Power
Downlink Output
dBm 43 43 43 43 43 43 43 43
Power
Uplink Maximum
dB 30
gain
Downlink
dB 35
Maximum gain
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple
dB ≤6 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP
TS 3GPP TS
3GPP 3GPP 3GPP 3GPP 3GPP 3GPP
Spurious 25.106 25.106
TS TS TS TS TS TS
emission 3GPP 3GPP TS
36.106 25.106 25.106 36.106 25.106 36.106
TS 36.106
36.106
Uplink Noise
Figure at dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max Downlink
dBm 30
Input Power
* Note: When 800MHz and 850MHz used together the gain will be 3dB decrease in 800MHz DL
and 850MHz UL, and 800MHz output power will be 40dBm and 850MHz NF will be 8dB.
** Note: 1800MHz, 1900MHz, 2100MHz and AWS band will not be used together due to
frequency interference. Suggest 1800+2100 and 1900+AWS band.

Page 69 of 232
Specifications
Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400

Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
CMU 528 x 298 x 251

Dimensions, H x W x D Per RF Unit mm 528 x 290 x 152

Mounting Rack 602 x 820 x 80

CMU 25

Weight (approx.) Per RF Unit kg 15

Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200 (8 bands)

RF Connectors N-Female

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 70 of 232
ComFlex Series Distributed Antenna System
ComFlex-8A00 (CM) 20W
Features

 Modularized Master Unit and Remote Unit support field upgrade andindependent gain control.
 RF module supports both simplex/duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, and LTE.
 Comply with 3GPP and supports LTEMIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU/PA/optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
form factor for easy installation, and its modular design is easy for upgrading and maintenance, which
supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 71 of 232
Specifications
Optical
800MHz, 800MIMO, 900MHz, 1800MHz, 1800MIMO, 2100MHz,
System
2600MHz, 2600MIMO
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors MU: SC/APC, RU: FC/APC


Maximum Remote Unit per Master
8(With FOU extension)
Unit

Electrical
800 800 900 1800 1800 2100M 2600M 2600
MHz MIMO MHz MHz MIMO Hz Hz MIMO
Uplink Frequency 1710-17 1710-17 1920-19 2500-25 2500-25
832-862 832-862 880-915
Range 85 85 80 70 70
Downlink MHz
1805-18 1805-18 2110-21 2620-26 2620-26
Frequency 791-821 791-821 925-960
80 80 70 90 90
Range
Operating 35 75 75 60
MHz 30 30 70 70
Bandwidth
Downlink Output 43 43 43 43 43 43
dBm 43 43
Power
Uplink Maximum
dB 30
gain
Downlink
dB 35
Maximum gain
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple
dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP 3GPP
3GPP TS 25.106
Spurious emission 3GPP TS 36.106 TS TS 3GPP TS 36.106
3GPP TS 36.106
25.106 25.106
Uplink Noise
Figure at Maximum dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink
dBm 30
Input Power

Page 72 of 232
Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400

Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Specifications
Mechanical---RU
Total Dimension 602 x 300 x 873

CMU 528 x 298 x 251


Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *4
Mounting Rack 602 x 820 x 30

Total Weight 93

CMU 25
Weight (approx.) kg
RF Unit 15x 4
Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200

RF Connectors N-Female, duplex

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 73 of 232
ComFlex Series Distributed Antenna System
ComFlex-8B00 (CM) 20W
Features

 Modularized Master Unit and Remote Unit support field upgrade and
 Independentgain control.
 RF module supports both simplex and duplex in MU.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU expansion in Master Unit.
 GSM 1800 & UMTS 2100 support PA backup.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and medium power Remote Unit (RU). The MU includes the
Chassis, Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design,
it can support up to 8 independent RF inputs and 2 Remote Units (or 4 Remote Units with FOU
extension). The Remote Unit is designed with a compact form factor for easy installation, and itsmodular
design is easy for upgrading and maintenance which supports 8 independent bands, 1800MHz,
1800MIMO, 2100MHz, 2100MIMO, 2300MHz, 2300MIMO, 2600MHz and 2600MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 74 of 232
Specifications
Optical Specifications
1800MHz, 1800MIMO, 2100MHz, 2100MIMO, 2300MHz, 2300MIMO,
System
2600MHz, 2600MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to -2


dBm
Power Remote Unit 3 to 5
Optical Return Loss dB >50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors MU: SC/APC; RU: FC/APC
Maximum Remote Unit per Master
4 (with FOU extension)
Unit

Electrical Specifications--MU+RU A
2100MHz 2100MIM 2300MH 2300MIM 2600MIM
2600MHz
O z O O
Uplink 1920-1980 1920-1980 2300-2390 2300-2390 2500-2570 2500-2570
Frequency MHz
Range Downlin
2110-2170 2110-2170 2300-2390 2300-2390 2620-2690 2620-2690
k
Operating Bandwidth MHz 60 60 90 90 70 70
Uplink Output Power dBm -30 -30 -30 -30 -30 -30
Downlink Output 43 43 43 43
dBm 43 43
Power
Uplink Maximum gain dB 30
Downlink Maximum
dB 35
gain
ATT Adjustable Range
dB MU: 0-40, RU: 0-30
(1dB step)
Pass Band Ripple
dB ≤5 ≤5 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP TS 25.106
Spurious emission 3GPP TS 36.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
se
System Delay ≤2
c
VSWR ≤ 1.5
Max. Downlink Input
dBm 30
Power

Electrical Specifications--MU+RU B
1800MHz 1800MIMO
Uplink 1710-1785 1710-1785
Frequency Range MHz
Downlink 1805-1880 1805-1880
Operating Bandwidth MHz 75 75
Uplink Output Power dBm -30 -30
Downlink Output Power dBm 43 43

Uplink Maximum gain dB 30


Downlink Maximum gain dB 35
ATT Adjustable Range(1dB step) dB MU: 0-40, RU: 0-30
Pass Band Ripple (p-p) dB ≤6 ≤6
3GPP TS 25.106 3GPP TS 25.106
Spurious emission
3GPP TS 36.106 3GPP TS 36.106
Inter modulation dBc 60 60
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power dBm 30

Page 75 of 232
Specifications
Mechanical Specifications--MU
Chassis 178 x 482 x 360

Dimensions Fiber Optical Unit 37 x 185 x 299


mm
H x W x D (approx.) RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400

Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
RF Unit 1
Power Supply Unit 2.5

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical Specifications--RU A
Combine and Monitor
Dimensions 528 x 298 x 251
Unit mm
H x W x D (approx.)
RF Unit 528 x 290 x 152
Combine and Monitor
30
Weight (approx.) Unit kg
RF Unit 20

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200

RF Connectors N-Female

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 76 of 232
Mechanical Specifications--RU B
Combine and Monitor
528 x 298 x 251
Unit mm
Dimensions
H x W x D (approx.) RF Unit 528 x 290 x 152

Switch Unit 528 x 290 x 152


Combine and Monitor
30
Unit kg
Weight (approx.) RF Unit 20

Switch Unit 15

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200

RF Connectors N-Female

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall


Note: These MU and RU are customized forCT125-15E project. All the design
and parameters to be finalized according to the tende requirements.

Page 77 of 232
ComFlex Series Distributed Antenna System
ComFlex-8C00 (CM) 20W
Features

 Modularized Master Unit and Remote Unit support field upgrade and independent
 gain control.
 RF module supports both simplex/duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP and supports LTEMIMO.
 Optical link auto gain control.
 Web based GUI forintelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU/PA/optical backup (conditional) and grey optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis,
Power Supply Unit (PSU), Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can
support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact
form factor for easy installation, and its modular design is easy for upgrading and maintenance which
supports 8 independent bands, 900MHz, 1800MHz, 2100MHz, 2600MHz, 900MIMO, 1800MIMO,
2100MIMO and 2600MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 78 of 232
Specifications
Optical
900MHz, 900MIMO, 1800MHz, 1800MIMO,
System
2100MHz,2100MIMO,2600MHz, 2600MIMO
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM

Optical Output Master Unit -4 to2


dBm
Power Remote Unit 3.0to5.0
Optical Return Loss dB >50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors MU:SC/APC; RU:FC/APC


Maximum Remote Unit per Master
8 (With FOU extension)
Unit

Electrical
900 900 1800 1800 2100 2100 2600 2600
MHz MIMO MHz MIMO MHz MIMO MHz MIMO
1710- 1710- 1920- 1920- 2500- 2500-
Frequen Uplink 832-862 832-862
1785 1785 1980 1980 2570 2570
cy MHz
Downlin 1805-18 1805-18 2110-21 2110-21 2620-26 2620-26
Range 791-821 791-821
k 80 80 70 70 90 90
Operating
MHz 30 30 75 75 60 60 70 70
Bandwidth
Uplink Output Power dBm -30 -30 -30 -30 -30 -30 -30 -30
Downlink Output 43 43 43 43 43
dBm 43 43 43
Power
Uplink Maximum
dB 30
gain
Downlink Maximum
dB 35
gain
ATT Adjustable
dB MU: 0-40, RU: 0-30
Range(1dB step)
Pass Band Ripple
dB ≤5 ≤5 ≤5 ≤5 ≤5 ≤5 ≤5 ≤5
(p-p)
3GPP TS 25.106
Spurious emission 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure
dB ≤5
at Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max .Downlink Input
dBm 30
Power

Page 79 of 232
Specifications
Mechanical Specifications---MU
Total Dimension 178 x 482 x 480

Chassis 178 x 482 x 360


Dimensions, H x W x D Fiber Optical Unit mm 37 x 185 x 299
RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400

Total Weight 29

Chassis 12
Weight (approx.) Fiber Optical Unit kg 2x2
RF Unit 1x8
Power Supply Unit 2.5x2

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 85

RF Connectors N-Female

Fiber Connectors SC/APC

Operating Temperature °C 0 to +40

Operating Humidity ≤ 85%

Ingress protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical Specifications---RU
Total Dimension 602 x 300 x 873

CMU 528 x 298 x 251


Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 x4

Mounting Rack 602 x 30 x 873

Total Weight 95

CMU 27
Weight (approx.) kg
RF Unit 15 x4

Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200

RF Connectors N-Female

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 80 of 232
ComFlex Series Distributed Antenna System
ComFlex-5M00(AI) 10W20W
Features

 Low PIM to BTS (≤ -160dBc).


 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
 independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote
Unit (RU). The ACU includes the Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular
design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed
with a compact and slim form factor for easy installation; it is an integrated design which supports 3
independent bands.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 81 of 232
Specifications
Optical
System 1900MHz, AWS, 2600MHz

Optical Fiber Single Mode


Optical Wavelength nm 1310, 1550 + WDM

Optical Output OCU -4 to -2


dBm
Power Remote Unit 3.0 to 5.0

Optical Return Loss dB > 50


Max. Optical Loss dB 6.5

Optical Automatic Gain Control dB 6.5

Fiber Connectors OCU: SC/APC, RU: FC/APC


Maximum Remote Unit connected to
8
OCUs

Electrical
1900MHz AWS 2600
Frequency Uplink 1850-1910 1710-1755 2500-2570
MHz
Range Downlink 1930-1990 2110-2155 2620-2690
Operating Bandwidth MHz 65 45 70
Downlink Output Power dBm 43 43 43

Uplink Maximum gain dB -3

Downlink Maximum gain dB -3 @ 46dBm input


ATT Adjustable Range(1dB
dB ACU: 0-70, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤6 ≤5 ≤6
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 36.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power
dBm 50
per RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450

Weight (approx.) kg 50(with 8 RFUs)

VAC 100-240
Power Supply
VDC -48

Power Consumption (approx.) W 180 (with 8 RFUs)

RF Connectors Input: Din, duplex; Output: QMA, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Fan

Installation Type 19” Rack

Page 82 of 232
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8

RF Connectors QMA-Female, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8 (with 2 FOUs)

Power Supply DC +28V (from ACU) @ 0.7A

Power Consumption (approx.) W 30

RF Connectors QMA-Female, simplex

Fiber Connectors SC/APC

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical Specifications---RU
10W 20W
Dimensions, H x W x D mm 1270 x 236 x 200

Weight (approx.) kg 49

Power Supply VAC 100-240/47-36Hz

Power Consumption (approx.) W 850 1100

RF Connectors 3 x 7/16 DIN-F

Fiber Connectors SC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Fan

Installation Type Wall/Pole

Page 83 of 232
ComFlex Series Distributed Antenna System
ComFlex AM
Features

 Low PIM to BTS (≤ -160dBc).


 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
 independent gain control.
 ACU supports 8 operators duplexinput.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension
 Remote Unit supports PSU/PA/optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote
Unit (RU). The ACU includes the Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular
design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed
with a compact form factor for easy installation, and its modular design is easy for upgrading and
maintenance, supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 84 of 232
Specifications
Optical
700MHz, 800MHz, 850MHz, 900MHz, 1800MHz, EAWS, 1900MHz,
System
2100MHz, 2600MHz and MIMO (max. 8 bands)
Optical Fiber Single Mode

Optical Wavelength nm 1310, 1550 + WDM

Optical Output OCU -4 to -2


dBm
Power Remote Unit 3.0 to5.0
Optical Return Loss dB > 50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors OCU:SC/APC,RU:FC/APC


Maximum Remote Unit connected to
8 (16 with FOU extension) in SISO, 4 (8 with FOU extension) in MIMO
OCU

Electrical
700MHz 700APAC 800MHz 850MHz 900MHz 1800MHz
Uplink Frequency 698-716/
703-748 806-824 824-849 880-915 1710-1785
Range 776-787
MHz
Downlink Frequency 728-746/
758-803 851-869 869-894 925-960 1805-1880
Range 746-757
Operating Bandwidth MHz 18/11 45 18 25 35 75
Downlink Output
dBm 43 43 43 43 43 43
Power
Uplink Maximum gain dB -3 -3 -3 -3 -3 -3
Downlink Maximum
gain dB -3 -3 -3 -3 -3 -3
(@ 46dBm input)
ATT Adjustable Range
dB ACU: 0-70, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5 ≤5 ≤6
3GPP TS
3GPP TS 3GPP TS 3GPP TS 3GPP TS 3GPP TS 25.106
Spurious emission
36.106 36.106 36.106 25.106 36.106 3GPP TS
36.106
Uplink Noise Figure at
dB ≤5 ≤5 ≤5 ≤5 ≤5 ≤5
Maximum Gain
se
System Delay ≤2
c
VSWR ≤ 1.5
Max. Downlink Input
dBm 50
Power per RFU of ACU

Page 85 of 232
Electrical
EAWS 1900MHz 2100MHz 2600MHz
Uplink Frequency 1710-1780 1850-1915 1920-1980 2500-257
Range
MHz
Downlink Frequency
2110-2180 1930-1995 2110-2170 2620-2690
Range
Operating Bandwidth MHz 70 65 60 70
Downlink Output Power dBm 43 43 43 43
Uplink Maximum gain dB -3 -3 -3 -3
Downlink Maximum
gain dB -3 -3 -3 -3
(@ 46dBm input)
ATT Adjustable Range
dB ACU: 0-70, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤6 ≤6 ≤6 ≤6
3GPP TS 25.106
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤5 ≤5 ≤5 ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
Power per RFU of dBm 50
ACU

Specifications
Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450

Rack 15.5

Per RFU 4.5 (max. support 8 RF units)


Weight (approx.) kg
PSU 2

MCU 1.5

VAC 100-240/50-60Hz
Power Supply
VDC -48/47-63Hz

Power Consumption (approx.) W 180 (with 8 RFUs)

RF Connectors Input: Din, duplex; Output: QMA, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Fan

Installation Type 19” Rack

Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 6.5

RF Connectors QMA-Female, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Page 86 of 232
Mechanical---OCU
Dimensions, H x W x D mm 44 x 485x 450

Rack 5
Weight (approx.) kg
Per FOU 2 (max. support 2FOUs)

Power Supply DC +28V (from ACU) @ 0.7A

Power Consumption (approx.) W 30

RF Connectors QMA-Female, simplex

Fiber Connectors SC/APC

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
CMU 528 x 251 x 298
Dimensions, H x W x D Per RF Unit mm 528 x 152 x 290(max. support 4 RF units)
Mounting Rack 602 x 820 x 30

CMU 30
Weight (approx.) Per RF Unit kg 20 (max. support 4 RF units)
Mounting Rack 8

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 150 Per band (max. 1200)

RF Connectors N-Female, duplex

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 87 of 232
ComFlex Series Distributed Antenna System
ComFlex-5900(AM) 20W
Features

 Low PIM to BTS (≤ -160dBc).


 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
 independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 RU supports PSU\PA\optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote
Unit (RU). The ACU includes the Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular
design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed
with a compact form factor for easy installation, and its modular design is easy for upgrading and
maintenance which supports 3 independent bands, 850MIHz, 1900MHz and AWS.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 88 of 232
Specifications
Optical
System 850MHz, 1900MHz, AWS

Optical Fiber Single Mode


Optical Wavelength nm 1310, 1550 + WDM

Optical Output OCU -4 to -2


dBm
Power Remote Unit 3.0 to 5.0

Optical Return Loss dB > 50


Max. Optical Loss dB 6.5

Optical Automatic Gain Control dB 6.5

Fiber Connectors OCU: SC/APC, RU: FC/APC


Maximum Remote Unit connected to
8(With FOU extension)
OCUs

Electrical
850MHz 1900MHz AWS
Frequency Uplink 824-849 1850-1910 1710-1755
MHz
Range Downlink 869-894 1930-1990 2110-2155
Operating Bandwidth MHz 25 60 45
Downlink Output Power dBm 43 43 43

Uplink Maximum gain dB -3 @ 46dBm input

Downlink Maximum gain dB -3 @ 46dBm input


ATT Adjustable Range(1dB
dB ACU: 0-70, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106
Spurious emission
3GPP TS 36.106 3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power
dBm 50
per RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450

Weight (approx.) kg 50(with 8 RFUs)

VAC 100-240
Power Supply
VDC -48

Power Consumption (approx.) W 180 (with 8 RFUs)

RF Connectors Input: Din, duplex; Output: QMA, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Fan

Installation Type 19” Rack

Page 89 of 232
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8

RF Connectors QMA-Female, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8 (with 2 FOUs)

Power Supply DC +28V (from ACU) @ 0.7A

Power Consumption (approx.) W 30

RF Connectors QMA-Female, simplex

Fiber Connectors SC/APC

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
CMU 528 x 251 x 298
Dimensions, H x W x D RF Unit mm 528 x 152 x 290*2

Mounting Rack 602 x 820 x 30

CMU 30
Weight (approx.) RF Unit kg 20*2

Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 500

RF Connectors N-Female, duplex

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 90 of 232
ComFlex Series Distributed Antenna System
ComFlex-4100(AM) 20W
Features

 Low PIM to BTS (≤ -160dBc).


 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
 independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 Remote Unit supports PSU/PA/optical backup (conditional) and grey optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote
Unit (RU). The ACU includes the Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular
design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed
with a compact form factor for easy installation, and its modular design is easy for upgrading and
maintenance.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

Page 91 of 232
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz

Optical Fiber Single Mode


Optical Wavelength nm 1310, 1550 + WDM
Optical Control
Optical Output -4 to -2
Unit dBm
Power
Remote Unit 3.0to5.0
Optical Return Loss dB >50

Max. Optical Loss dB 6.5


Optical Automatic Gain Control dB 6.5

Fiber Connectors OCU:SC/APC, RU:FC/APC

Maximum Remote Unit per Master Unit 8 (SISO) / 4 (MIMO)

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
Downlink Frequency MHz
925-960 1805-1880 2110-2170 2620-2690
Range
Operating Bandwidth MHz 35 75 60 70
Downlink Output Power dBm 43 43 43 43

Uplink Maximum gain dB -3


Downlink Maximum gain
dB -3
(@46dBm input)
ATT Adjustable
dB ACU: 0-70, RU: 0-30
Range(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6 ≤6
3GPP TS 25.106
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 50
Power

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450

Weight (approx.) kg 50(with 8 RFUs)

VAC 100-240
Power Supply
VDC -48

Power Consumption (approx.) W 180 (with 8 RFUs)

RF Connectors Input: Din, duplex; Output: QMA, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Fan

Installation Type 19” Rack

Page 92 of 232
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8

RF Connectors QMA-Female, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8 (with 2 FOUs)

Power Supply DC +28V (from ACU) @ 0.7A

Power Consumption (approx.) W 20

RF Connectors QMA-Female, simplex

Fiber Connectors SC/APC

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
Total Dimension 602 x 555 x 300

CMU 528 x 298 x 251


Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *2
Mounting Rack 602 x 555 x 30

Total Weight 63

CMU 25
Weight (approx.) kg
RF Unit 15 *2
Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 650

RF Connectors N-Female, duplex

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 93 of 232
ComFlex Series Distributed Antenna System
ComFlex-8A00 (AM) 20W
Features

 Low PIM to BTS (≤ -160dBc).


 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
 independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 Remote Unit supports PSU/PA/optical backup (conditional) and gray optional.

ProductDescription
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The
system consists of the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote
Unit (RU). The ACU includes the Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular
design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed
with a compact form factor for easy installation, and its modular design is easy for upgrading and
maintenance.

This solution is an effective point-to-multipoint distributed antenna system that provides effective
coverage enhancement. The Comba DAS offers service providers an optimal solution for multiple
applications from a single building to a campus, mega mall, or sports arena and beyond.

FunctionalBlock Diagram

Page 94 of 232
Specifications
Optical
800MHz, 800MIMO, 900MHz, 1800MHz, 1800MIMO, 2100MHz,
System
2600MHz, 2600MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM

Optical Output OCU -4 to -2


dBm
Power Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors OCU: SC/APC, RU: FC/APC
Maximum Remote Unit connected to
8 (with FOU extension)
OCUs

Electrical
800 800 900 1800 1800 2100M 2600M 2600
MHz MIMO MHz MHz MIMO Hz Hz MIMO
Uplink Frequency 1710-17 1710-17 1920-19 2500-25 2500-25
832-862 832-862 880-915
Range 85 85 80 70 70
Downlink MHz
1805-18 1805-18 2110-21 2620-26 2620-26
Frequency 791-821 791-821 925-960
80 80 70 90 90
Range
Operating 35 75 75 60
MHz 30 30 70 70
Bandwidth
Downlink Output 43 43 43 43 43 43
dBm 43 43
Power
Uplink Maximum -3
dB
gain
Downlink
Maximum gain dB -3
(@46dBm input)
ATT Adjustable
dB ACU: 0-70, RU: 0-30
Range(1dB step)
Pass Band Ripple
dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP 3GPP
3GPP TS 25.106
Spurious emission 3GPP TS 36.106 TS TS 3GPP TS 36.106
3GPP TS 36.106
25.106 25.106
Uplink Noise
Figure at Maximum dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink
Input Power per dBm 50
RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Weight (approx.) kg 50(with 8 RFUs)
VAC 100-240
Power Supply
VDC -48
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output: QMA, simplex
Operating Temperature °C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack

Page 95 of 232
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8

RF Connectors QMA-Female, simplex

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485x 450

Weight (approx.) kg 8 (with 2 FOUs)

Power Supply DC +28V (from ACU) @ 0.7A

Power Consumption (approx.) W 20

RF Connectors QMA-Female, simplex

Fiber Connectors SC/APC

Operating Temperature °C 0 to +45

Operating Humidity ≤ 85%

Ingress Protection IP30

Enclosure Cooling Convection

Installation Type 19” Rack

Mechanical---RU
Total Dimension 602 x 300 x 873

CMU 528 x 298 x 251


Dimensions, H x W x D mm
RF Unit 528 x 290 x 152x4
Mounting Rack 602 x 820 x 30

Total Weight 93

CMU 25
Weight (approx.) kg
RF Unit 15 *4
Mounting Rack 8

Power Supply AC110/220V VAC 100-240/50-60Hz

Power Consumption (approx.) W 1200

RF Connectors N-Female, duplex

Fiber Connectors FC/APC

Operating Temperature °C -40 to +55

Operating Humidity ≤ 95%

Ingress protection IP65

Enclosure Cooling Convection

Installation Type Wall

Page 96 of 232
 RX Series Digital Band
Selective Repeater

Page 97 of 232
RX Series Digital Band Selective Repeater
Features

 Up to 4 pass band segments with independent ON/OFF for maximum flexibility.


 5W/10W total output power.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after
power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and
omni-sealed (IP65).
 Can be configured as Master Unit (MU) or Slave Unit (SU) in a centralized
monitoring system.

FunctionalBlock Diagram

Operation andMaintenance

 Using a direct connection to a PC by RJ45, installation and commissioning of the system is


accomplished by the OMT. Using the integrated wireless modem, the equipment parameters can be
monitored and controlled remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Isolation Detection Switch,
Channel No. Range, ATT, Over-Temp Threshold, DL Input Power Threshold, DL Output Power
Threshold and Alarm Report Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault,
Door Open, DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output Power
and DL Input Power.
 The system has been developed to take advantage of advanced network operation, where the CMS
(optional) provides an effective solution for central monitoring of a group of Comba products.

Page 98 of 232
Outline Drawing

300 164

RUN

ALM

MODEM
430

AC 100V-240V
50/60Hz AC OUT
RS-485 EXT_ALM MODEM ANT

DT MT

Page 99 of 232
LTE700Digital Band Selective Repeater
RX-0739
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 718-748

Frequency Range, Downlink MHz 773-803


Operating Bandwidth Per Sub-band MHz 3-20

Number of Sub-bands 4
Total Output Power, Uplink dBm 23

Total Output Power, Downlink dBm 37 40


Maximum System Gain dB 90

Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec 6.5
Out of Band Gain

ACRR

EVM
Compliance with3GPP 36.106
Out of Band Spectrum Emissions

Input Inter modulation


Output Inter modulation

Absolute Maximum RF Input Power dBm -10


Input VSWR  1.5
Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18
Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 160 170

Power Up Waiting Time(approx.) sec 180


MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection


RF Connectors N-Female

Operating Temperature C -33 to +55


Operating Humidity  95%
Environmental Class IP65

MTBF hrs ≥ 50,000


Note: Typical specifications at room temperature

Page 100 of 232


850MHz Digital Band Selective Repeater
RX-8132
Specifications
Electrical 5W 10W
Operating Frequency, Uplink MHz 824-849
Operation Frequency, Downlink MHz 869-894
Operating Bandwidth Per Sub-band MHz 0.2-24.8
Number of Sub-bands 2
Total Output Power, Uplink dBm 33
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB ≤5
Uplink Noise Figure dB 5
System Group Delay sec ≤ 6.5
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection dBc
Offset ≥ 1MHz ≥ 60
Inter modulation @ GSM dBc ≥ 40
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.5
Impedance  50

Mechanical
Dimensions, H x W x D mm/in 430x300x164/16.9x11.8x6.5

Weight (approx.) kg/lb 18/39.7

Power Supply VAC 100-240/47-63Hz

Power Consume W 140 160

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +50

Operating Humidity  95%

Environmental Class IP65

MTBF hrs > 50,000


Note: Typical specification at room temperature;
.

Page 101 of 232


900MHz Digital Band Selective Repeater
RX-9139
Specifications
Electrical 5W 10W
Operating Frequency, Uplink MHz 885-915
Operation Frequency, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB ≤5
Uplink Noise Figure dB 5
Out-of-Band Gain
Inter modulation
Spurious Emission
EVM Compliance with 3GPP TS 25.106
ACRR
PCDE
Spurious Emission Mask
System Group Delay sec ≤ 6.5
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection dBc
Offset ≥ 1MHz ≥ 60
Inter modulation @ GSM dBc ≥ 40
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.5
Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight (approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consume W 140 160

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +50

Operating Humidity  95%

Environmental Class IP65

MTBF hrs > 50,000


Note: Typical specification at room temperature;
.

Page 102 of 232


1800MHz Digital Channel Selective Repeater
RX-1823
Features

 Support 5/10/15/20MHz different bandwidth LTE carrier


 5W/10W total output power.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature that can reduce the isolation requirement up to 30dB.
 Integrated LTE wireless modem for remote configuration, monitoring and
control.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation– waterproof, damp-proof and
omni-sealed (IP65).

Functional Block Diagram

Page 103 of 232


Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785

Frequency Range, Downlink MHz 1805-1880


Operating Bandwidth MHz 5/10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 100

Gain Adjustment Range (1dB step) dB 0-30


Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec 6.5
Spectrum Emission Mask

ACRR
EVM Compliance with 3GPP TS 36.106

PCDE

Inter modulation
Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 150 160

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specification at room temperature

Page 104 of 232


1800MHz Digital Band Selective Repeater
RX-1839
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Instantaneous Bandwidth MHz 60
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec 6.5
Out of Band Gain
ACRR
EVM
Compliance with ETSI EN 301 908-15*
Out of Band Spectrum Emissions
Input Inter modulation
Output Inter modulation
±600kHz ≥45
Out-of-Band Rejection@ GSM dBc
±1MHz ≥ 60
Inter modulation @ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight(approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption(approx.) W 160 170
Power Up Waiting Time(approx.) sec 180
MCU Battery Backup Time(approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hrs ≥ 50,000
Note: Typical specifications at room temperature
*: Compliant to LTE standard @ UL 23dBm.

Page 105 of 232


1900MHz Digital Band Selective Repeater
RX-1939
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 1850-1910

Frequency Range, Downlink MHz 1930-1990


Operating Bandwidth Per Sub-band MHz 0.2-25

Number of Sub-bands 4

Total Output Power, Uplink dBm 30


Total Output Power, Downlink dBm 37 40

Maximum System Gain dB 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple, p-p dB 6


Uplink Noise Figure dB 5
System Group Delay sec 6.5
±600kHz dBc ≥ 45
Out-of-Band Rejection
±1MHz dBc ≥ 60

9kHz-1GHz dBm -36


Spurious
1GHz-12.75GHz dBm -30

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Mechanical
mm/
Dimensions, H x W x D 430 x 300 x 164/16.9 x 11.8 x 6.5
in
Weight(approx.) kg/lb 18/39.7
Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 150 160

Power Up Waiting Time(approx.) sec 180


MCU Battery Backup Time(approx.) hrs 2

Enclosure Cooling Convection


RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%


Environmental Class IP65

MTBF hrs ≥ 50,000


Note: Typical specifications at room temperature

Page 106 of 232


2100MHz Digital Band Selective Repeater
RX-2139
Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec 6.5
Out-of-Band Gain
Inter modulation
Spurious Emission
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply 100-240/47-63Hz

Power Consumption(approx.) W 150 160 180

Power Up Waiting Time(approx.) sec 180

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specifications at room temperature

Page 107 of 232


2600MHz Digital Band Selective Repeater
RX-2620
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 2500-2570
Frequency Range, Downlink MHz 2620-2690
Operating Bandwidth MHz 10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40

Maximum System Gain dB 85


Gain Adjustment Range (1dB Step) dB 0-30

Pass Band Ripple dB 4


Uplink Noise Figure dB 5
System Group Delay sec 7
Out of Band Gain
ACRR

EVM
Compliance with 3GPP TS 36.106
Out of Band Spectrum Emissions

Input Inter modulation


Output Inter modulation

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Mechanical
Dimensions, H x W x D mm 330 x 420 x 182

Weight (approx.) kg 25

Power Supply VAC 100-240/47-63Hz


Power Consumption W 150 170

Power Up Waiting Time (approx.) sec 180


MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection


RF Connectors N-Female

Operating Temperature °C -33 to +55

Operating Humidity 95%


Environmental Class IP65

MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

Page 108 of 232


2600MHz Digital Channel Selective Repeater
RX-2623
Features

 Support 5/10/15/20MHz different bandwidth LTE carrier


 Utilizing the latest Pre-distortion MCPA technologies, up to20W Downlink Power
Output.
 5W/10W/20W total output power.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature that can reduce the isolation requirement up to 30dB.
 Integrated LTE wireless modem for remote configuration, monitoring and
control.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation– waterproof, damp-proof and
omni-sealed (IP65).

Functional Block Diagram

Page 109 of 232


Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 2500-2570

Frequency Range, Downlink MHz 2620-2690


Operating Bandwidth MHz 5/10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain dB 100
Gain Adjustment Range (1dB step) dB 0-30

Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec 6.5
Spectrum Emission Mask
ACRR

EVM Compliance with 3GPP TS 36.106

PCDE
Inter modulation

Absolute Maximum RF Input Power dBm -10


Input VSWR  1.5

GSM/GPRS/EDGE: 900/1800 MHz


LTE Modem WCDMA: 900/1800/2100 MHz;
FDD LTE: 800/900/1800/2100/2600 MHz;

Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 140 150 160

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%


Environmental Class IP65

MTBF* hr ≥100,000

Note: Typical specification at room temperature


*Special for Australia

Page 110 of 232


RX Series Multi-band Digital Band Selective Repeater
Features

 2 or 3 bands configuration in one system.


 Each band has up to 4 pass band segments with independent ON/OFF
for maximum flexibility.
 5W/10W total output power for each band.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after
power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and
omni-sealed (IP65).

FunctionalBlock Diagram

Page 111 of 232


Operation andMaintenance

 Using a direct connection to a PC by RJ45, installation and commissioning of the system is


accomplished by the OMT. Using the integrated wireless modem, the equipment parameters can be
monitored and controlled remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Isolation Detection Switch,
Channel No. Range, ATT, Over-Temp Threshold, DL Input Power Threshold, DL Output Power
Threshold and Alarm Report Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault,
Door Open, DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output Power
and DL Input Power.
 The RX-system has been developed to take advantage of advanced network operation, where the
CMS (optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

440 355
408

Dual band

645
433

Page 112 of 232


Tri-band

Page 113 of 232


850MHz + 1900MHzDigital Band Selective Repeater
RX-7137
Specifications-850MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 824-849

Frequency Range, Downlink MHz 869-894


Operating Bandwidth Per Sub-band MHz 0.2-24.8

Number of Sub-bands 2
Total Output Power, Uplink dBm 33

Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple at FBW, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec  6.5

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60

Inter modulation@ GSM dBc ≥ 40


Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50
Note: Typical specifications at room temperature

Specifications-1900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1850-1910
Frequency Range, Downlink MHz 1930-1990

Operating Bandwidth Per Sub-band 0.2-25

Number of Sub-bands 4
Total Output Power, Uplink dBm 30

Total Output Power, Downlink dBm 37 40


Maximum System Gain 90

Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple, p-p dB 6


Uplink Noise Figure dB 5
System Group Delay sec  6.5

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60
Inter modulation@ GSM dBc ≥ 40

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Note: Typical specifications at room temperature

Page 114 of 232


Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm/In 440x408x355/17.3x16x14

Weight (approx.) kg/lb 45/99.2

Power Supply 100-240/47-63Hz

Power Consumption (approx.) W 290 320

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Page 115 of 232


900MHz + 1800MHzDigital Band Selective Repeater
RX-7539
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915

Frequency Range, Downlink MHz 930-960


Operating Bandwidth Per Sub-band MHz 0.2-25

Number of Sub-bands 4
Total Output Power, Uplink dBm 27

Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple at FBW, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec  6.5

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60

Inter modulation@ GSM dBc ≥ 40


Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Note: Typical specifications at room temperature

Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*
Out of Band Gain

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60
Inter modulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature,
*: Compliant to LTE standard @ UL 23dBm.

Page 116 of 232


Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355

Weight (approx.) kg 45

Power Supply 100-240/47-63Hz

Power Consumption (approx.) W 300 330

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Page 117 of 232


900MHz + 2100MHzDigital Band Selective Repeater
RX-7639
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915

Frequency Range, Downlink MHz 930-960


Operating Bandwidth Per Sub-band MHz 0.2-25

Number of Sub-bands 4
Total Output Power, Uplink dBm 27

Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple at FBW, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec  6.5

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60

Inter modulation@ GSM dBc ≥ 40


Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Note: Typical specifications at room temperature

Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170

Operating Bandwidth Per Sub-band 3-20*

Number of Sub-bands 4
Instantaneous Bandwidth MHz 30

Total Output Power, Uplink dBm 23


Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Uplink Noise Figure dB 5


System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

Page 118 of 232


Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355

Weight (approx.) kg 45

Power Supply 100-240/47-63Hz

Power Consumption (approx.) W 290 320

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Page 119 of 232


1800MHz + 2100MHzDigital Band Selective Repeater
RX-7839
Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785

Frequency Range, Downlink MHz 1805-1880


Operating Bandwidth Per Sub-band MHz 0.2-25

Number of Sub-bands 4
Total Output Power, Uplink dBm 30

Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple at FBW, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*

Out of Band Gain

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60
Inter modulation@ GSM dBc ≥ 40

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50
Note: Typical specifications at room temperature,
*: Compliant to LTE standard @ UL 23dBm.
Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band 3-20*
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

Page 120 of 232


Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355

Weight (approx.) kg 45

Power Supply 100-240/47-63Hz

Power Consumption (approx.) W 310 330

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Page 121 of 232


Tri-Band Digital Band Selective Repeater
RX-5239
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915

Frequency Range, Downlink MHz 930-960


Operating Bandwidth Per Sub-band MHz 0.2-25

Number of Sub-bands 4
Total Output Power, Uplink dBm 27

Total Output Power, Downlink dBm 37 40

Maximum System Gain 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple at FBW, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec  6.5

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60

Inter modulation@ GSM dBc ≥ 40


Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Note: Typical specifications at room temperature

Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*
Out of Band Gain

Out-of-Band Rejection@ ±600kHz dB ≥ 45


GSM ±1MHz dB ≥ 60
Inter modulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature,
*: Compliant to LTE standard @ UL 23dBm.

Page 122 of 232


Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980

Frequency Range, Downlink MHz 2110-2170


Operating Bandwidth Per Sub-band 3-20*

Number of Sub-bands 4
Instantaneous Bandwidth MHz 30

Total Output Power, Uplink dBm 23


Total Output Power, Downlink dBm 37 40

Maximum System Gain 90

Gain Adjustment Range (1dB step) dB 0-30


Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain
Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355

Weight (approx.) kg 45

Power Supply 100-240/47-63Hz

Power Consumption (approx.) W 420 480

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

Equipment N-Female
RF Connectors
Combiner (Option) Din-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Page 123 of 232


RX Series Digital Channel Selective Repeater
RX-2123 III3
Features

 Utilizing the latest Pre-distortion MCPA technologies, up to20W Downlink


Power Output in a compact chassis (20L).
 2W/5W/10W/20W total output power.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature that can reduce the isolation requirement up to 30dB.
 Support up to 4WCDMA channels with independent ON/OFF switch.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after
power failure.
 Compatible to Comba generic OMT and CMS plat form.
 Designed for all weather outdoor installation– waterproof, damp-proof and
omni-sealed (IP65).
 Can be configured as Master Unit (MU) or Slave Unit (SU) in a centralized
monitoring system.

Functional Block Diagram

Page 124 of 232


Specifications
Electrical 2W 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980

Frequency Range, Downlink MHz 2110-2170


Number of Channels 4
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 33 37 40 43
Maximum System Gain dB 105
Gain Adjustment Range (1dB step) dB 0-30

Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec 11
Spectrum Emission Mask
ACRR

EVM Compliance with 3GPP TS 25.106

PCDE
Inter modulation

Absolute Maximum RF Input Power dBm -10


Input VSWR  1.5
Impedance  50
Mechanical

Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

VAC 100-240/47-63Hz
Power Supply
VDC -68 to -38

Power Consumption(approx.) W 120 130 160 180

Power Up Waiting Time(approx.) sec 180

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specification at room temperature

Page 125 of 232


800MHz Digital Channel Selective Repeater
RX-0823
Features

 Support 5/10/15/20MHz different bandwidth LTE carrier


 Power Output software adjustable, up to20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature that can reduce the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and
control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and
omni-sealed (IP65).

Functional Block Diagram

Page 126 of 232


Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 832-862

Frequency Range, Downlink MHz 791-821


Operating Bandwidth MHz 5/10/15/20 (5MHz Step)
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain dB 100
Gain Adjustment Range (1dB step) dB 0-30

Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec 6.5
Spectrum Emission Mask
ACRR

EVM Compliance with 3GPP TS 36.106

PCDE
Inter modulation
Absolute Maximum RF Input
dBm -10
Power
Input VSWR  1.5
Impedance  50

Mechanical

Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 130 140 150

Power Up Waiting Time(approx.) sec 180

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specification at room temperature

Page 127 of 232


800MHz Digital Band Selective Repeater
RX-0823
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 832-862
Operation Frequency, Downlink MHz 791-821
Operating Bandwidth Per Sub-band MHz 0.2-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Inter modulation
Spurious Emission
Compliance with 3GPP TS 36.106
EVM
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361x222x 93/14.2x8.7x3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000

Note: Typical specification at room temperature.

Page 128 of 232


2100MHz Digital Channel Selective Repeater
RX-2123 IV4
Features

 Support 5/10/15/20MHz different bandwidth LTE carrier


 Power Output software adjustable, up to20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature that can reduce the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and
control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and
omni-sealed (IP65).

Functional Block Diagra

Page 129 of 232


Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth MHz 5/10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain dB 100
Gain Adjustment Range (1dB step) dB 0-30
Antenna Feedback Cancellation dB 30
Uplink Noise Figure dB 5
System Group Delay sec 6.5
Spectrum Emission Mask
ACRR
EVM Compliance with 3GPP TS 36.106
PCDE
Inter modulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 140 150 160

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specification at room temperature

Page 130 of 232


Operation andMaintenance

 Using a direct connection to a PC by RJ45, installation and commissioning of the device is


accomplished by the OMT. Using the integrated wireless modem, the equipment parameters can be
monitored and controlled remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Channel No. Range, ATT,
Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report
Enable.
 Monitored equipment parameters include:Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault,
Door Open, DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output
Power and DL Input Power.
 The device has been developed to take advantage of advanced network operation, where the CMS
(optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

300 164

RUN

ALM

MODEM
430

AC 100V-240V
50/60Hz AC OUT
RS-485 EXT_ALM MODEM ANT

DT MT

Page 131 of 232


800MHz Digital Channel Selective Repeater
RX-0823
Features

 Support 5/10/15/20MHz different bandwidth LTE carrier


 Power Output software adjustable, up to20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC) feature that can reduce
the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

FunctionalBlock Diagram

Page 132 of 232


900MHz Digital Channel Selective Repeater
RX-9123
Features

 Up to 12 GSM Channels
 Digitalized Antenna Feedback Cancellation (AFC) function to reduce
 The antenna isolation requirement up to 30dB.
 Dynamic Uplink Noise Control (UNC) function to reduce Uplink Interference by
 Automatically switch off the corresponding carriers when no traffic.
 5W/10W Downlink Output Power utilizing ultra Linear PA, supports GSM, GPRS and EDGE.
 Integrated wireless modem for remote configuration, monitoring and control.
 Internal backup battery keeps the alarm unit running for up to two hours after power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

FunctionalBlock Diagram

Page 133 of 232


Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 890-915

Frequency Range, Downlink MHz 935-960


Number of Channels 4/8/12
Total Output Power, Uplink dBm 33
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 100
Gain Adjustment Range (1dB Step) dB 0-30

Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec  11
Inter modulation dBc ≥ 40
at ±400KHz dB > 50

Channel Selectivity at ±600KHz dB > 55

at ±1MHz dB > 60
In Band Spurious 890-915 /935-960MHz dBc  -60
9KHz to 1GHz dBm  -36
Out of Band Spurious
1GHz to 12.75GHz dBm  -30
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50

Mechanical
Dimensions, H x W x D mm 420 x 330 x 182

Weight (approx.) kg 25

VAC 100-240/47-63Hz
Power Supply
VDC -68 to -38

Power Consumption (approx.) W 160 170

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature °C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specifications at room temperature

Page 134 of 232


Operation and Maintenance

 Using a direct connection to a PC by RJ45, installation and commissioning of the RX-9123 is


accomplished by the OMT. Using the integrated wireless modem, the equipment parameters can be
monitored and controlled remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Channel No. Range, ATT,
Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report
Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault,
Door Open, DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output
Power and DL Input Power.
 The RX-9123 has been developed to take advantage of advanced network operation, where the
CMS (optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

420

330
182

227

Page 135 of 232


900MHzDigital Channel Selective Repeater
RX-9123 IV4
Features

 Support 5/10/15/20MHz different bandwidth carrier


 Automatic Digital gain control and Antenna Feedback Cancellation (AFC)
feature
 that can reduce the isolation requirement up to 30dB.
 Integrated LTE wireless modem for remote configuration, monitoring and
control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation– waterproof, damp-proof and
omni-sealed (IP65).

Functional Block Diagram

Page 136 of 232


Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915

Frequency Range, Downlink MHz 930-960


Operating Bandwidth MHz 5/10/15/20(5MHz Step)
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 100

Gain Adjustment Range (1dB step) dB 0-30


Antenna Feedback Cancellation dB 30

Uplink Noise Figure dB 5


System Group Delay sec 6.5
Spectrum Emission Mask

ACRR
EVM Compliance with 3GPP TS 36.106

PCDE

Inter modulation
Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164

Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz

Power Consumption(approx.) W 140 160

MCU Battery Backup Time(approx.) hr 2

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr ≥ 50,000

Note: Typical specification at room temperature

Page 137 of 232


800MHz Tetra Band Selective Repeater
RX-8039
Specifications
Electrical 2W 5W 10W
Frequency Range, Uplink MHz 806-824

Frequency Range, Downlink MHz 851-869


Operating Bandwidth Per Sub-band MHz 0.2-18

Number of Sub-bands 4
Total Output Power, Uplink dBm 30

Total Output Power, Downlink dBm 33 37 40

Maximum System Gain dB 90


Gain Adjustment Range (1dB step) dB 0-30

Pass Band Ripple, p-p dB 5


Uplink Noise Figure dB 5
System Group Delay sec 6.5
Inter modulation dBc ≥40

±600kHz dBc ≥45


Out-of-Band Suppression
±1MHz dBc ≥ 60
9KHz to 1GHz dBm  -36
Spurious
1GHz to 12.75GHz dBm  -30

Absolute Maximum RF Input Power dBm -10

Input VSWR  1.5


Impedance  50

Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight(approx.) kg 18

Power Supply VAC 100-240/47-63Hz


Power Consumption(approx.) W 120 140 160

Power Up Waiting Time(approx.) sec 180

MCU Battery Backup Time(approx.) hr 2


Enclosure Cooling Convection

RF Connectors N-Female
Operating Temperature C -33 to +55

Operating Humidity  95%


Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

Page 138 of 232


 Public Safety

Page 139 of 232


Critical Point™ Public Safety Bi-Directional Amplifier
RX-7W22 Class A PS 700/800MHz BDA
Features

 Digital/programmable utilizing FPGA


 Supports public safety 700/800MHz in single band or dual band version
 Supports P25 P1/P2 digital and conventional analog communications
simultaneously
 Supports First Net TM LTE band 14
 Single band versions include license to switch from original band to alternate
band
 Single band can be upgraded to dual band via license key
 Each band supports up to 32 channels
 0.5/2W output power for each band
 Channelized Auto Gain Control (AGC) / Channelized uplink squelch
 Built-in mandatory isolation test to prevent BDA oscillation
 Auto shutdown with alarm upon oscillation detection
 Web based GUI for intelligent configuration, SNMP supported
 NFPA compliant dry contact alarms, NEMA 4X enclosure
 FCC: PX8RX-7W22, IC: 11919A-RX7W22

Specifications
Electrical 700MHz 800MHz
US: 788-805, CA:
Frequency Range, Uplink MHz 806-824
798-806
US: 758-775, CA:
Frequency Range, Downlink MHz 851-869
768-776
12.5/25/75+10MHz (LTE,
Channel Bandwidth KHz 12.5/25/75
US)
Number of Channels US: 32+1 (LTE), CA: 32 32

Total Output Power, Uplink dBm 27

Total Output Power, Downlink dBm 27/33 27/33

Maximum System Gain dB 90 90

Gain Adjustment Range (1dB step) dB 0-30 0-30

Pass Band Ripple, p-p dB 5 5


Uplink Noise Figure dB 5 5
Bandwidth: 12.5KHz  35  35
Bandwidth: 25KHz 27 27
System Group Delay sec
Bandwidth: 75KHz 15 15
Bandwidth: 10MHz
6.5 6.5
(LTE)
≥ 80 @ filter center + ≥ 80 @ filter center +
Bandwidth: 12.5KHz
75KHz 75KHz
≥ 80 @ filter center + ≥ 80 @ filter center +
Bandwidth: 25KHz
75KHz 75KHz
Out-of-Band Suppression dBc ≥ 80 @ filter center + ≥ 80 @ filter center +
Bandwidth: 75KHz
200KHz 200KHz
≥ 45 @ filter edge + ≥ 45 @ filter edge +
Bandwidth: 10MHz
0.6MHz 0.6MHz
(LTE)
≥ 60 @ filter edge + 1MHz ≥ 60 @ filter edge + 1MHz
Inter modulation dBm  -13  -13

Spurious 9kHz to 1GHz dBm FCC Compliance FCC Compliance

Page 140 of 232


Electrical 700MHz 800MHz
1GHz to 12.75GHz dBm
Absolute Maximum RF Input Power dBm 10 10
Input VSWR  1.5  1.5
Impedance  50 50

Specifications
Mechanical
in(mm
Dimensions, H x W x D 20.9 x 15.4 x 8.3 (530 x 390 x 210)
)
Weight(without bracket) lb(kg) 50.7 (23)

VAC 100-240/47-63Hz
Power Supply
VDC -40 to -58

Single band W 80
Power Consumption
Dual band W 100

Enclosure Cooling Convection

RF Connectors N-Female

Test Port SMA, -22dB

Maximum Input for Dry Contact Port 24VDC, 1A / 110VAC, 0.5A

Operating Temperature oF(°C) -27 to +140 (-33 to +60)

Operating Humidity  95%


Environmental Class NEMA 4X

MTBF hr ≥100,000 @ 77oF


Note: Typical specifications at room temperature,

OutlineDrawing

AC 100V-240V MT_TEST
50Hz/60Hz PWR
DT RUN MT OMT
DT_TEST ALM

ALM1 ALM2 AUX LAN

Page 141 of 232


Part Numbers
P/N
Product Type
AC Version DC Version
UL Certificate SGSNA_17_GZ_00139 SGSNA_17_GZ_00138
Class A (US)

Single band 700MHz RX7W22-07AA33AC RX7W22-07AA3348

Single band 800MHz RX7W22-08AA33AC RX7W22-08AA3348

Dual band 700/800MHz RX7W22-78AA33AC RX7W22-78AA3348

Class A (Canada)

Single band 700MHz RX7W22-C7AA33AC RX7W22-C7AA3348

Single band 800MHz RX7W22-C8AA33AC RX7W22-C8AA3348

Dual band 700/800MHz RX7W22-CFAA33AC RX7W22-CFAA3348

License

Dual Band (700/800MHz) License RX7W22-L783233

Page 142 of 232


Critical Point™ Public Safety Bi-Directional Amplifier
RX-7W22Class B PS 700/800MHz BDA
Features

 Digital/programmable utilizing FPGA


 Supports public safety 700/800MHz in single band or dual band version
 Supports P25 P1/P2 digital and conventional analog communications
simultaneously
 Supports FirstNetTM LTE band 14
 Single band versions include license to switch from original band to alternate
band
 Single band can be upgraded to dual band via license key
 Each band supports up to 3 sub bands
 0.5/2W output power for each band
 Built-in mandatory isolation test to prevent BDA oscillation
 Auto shutdown with alarm upon oscillation detection
 Web based GUI for intelligent configuration, SNMP supported
 NFPA compliant dry contact alarms, NEMA 4X enclosure
 FCC: PX8RX7W22-B, IC: 11919A-RX7W22

Specifications
Electrical 700MHz 800MHz
US: 788-805, CA:
Frequency Range, Uplink MHz US:806-817, CA:806-824
798-806
US: 758-775, CA:
Frequency Range, Downlink MHz US:851-862, CA:806-824
768-776
Operating Bandwidth MHz 0.2-10 0.2-10

Number of Sub Bands 3 3

Total Output Power, Uplink dBm 27

Total Output Power, Downlink dBm 27/33 27/33

Maximum System Gain dB 90 90

Gain Adjustment Range (1dB step) dB 0-30 0-30

Pass Band Ripple, p-p dB 5 5


Uplink Noise Figure dB 5 5
System Group Delay sec  6.5  6.5
≥ 45 @ filter edge + ≥ 45 @ filter edge +
Out-of-Band Suppression dBc 0.6MHz 0.6MHz
≥ 60 @ filter edge + 1MHz ≥ 60 @ filter edge + 1MHz
Inter modulation dBm  -13  -13
9kHz to 1GHz dBm
Spurious FCC Compliance FCC Compliance
1GHz to 12.75GHz dBm

Absolute Maximum RF Input Power dBm 10 10

Input VSWR  1.5  1.5


Impedance  50 50

Page 143 of 232


Specifications
Mechanical
Dimensions, H x W x D in(mm) 20.9 x 15.4 x 8.3 (530 x 390 x 210)

Weight(without bracket) lb(kg) 50.7 (23)

VAC 100-240/47-63Hz
Power Supply
VDC -40 to -58

Single band W 80
Power Consumption
Dual band W 100

Enclosure Cooling Convection

RF Connectors N-Female

Test Port SMA, -22dB

Maximum Input for Dry Contact Port 24VDC, 1A / 110VAC, 0.5A

Operating Temperature o
F(°C) -27 to +140 (-33 to +60)

Operating Humidity  95%


Environmental Class NEMA 4X

MTBF hr ≥ 100,000 @ 77oF

Note: Typical specifications at room temperature,

Outline Drawing

AC 100V-240V MT_TEST
50Hz/60Hz PWR
DT RUN MT OMT
DT_TEST ALM

ALM1 ALM2 AUX LAN

Page 144 of 232


Part Numbers
P/N
Product Type
AC Version DC Version
UL Certificate SGSNA_17_GZ_00139 SGSNA_17_GZ_00138
Class B(US)

Single band 700MHz RX7W22-07B333AC RX7W22-07B33348

Single band 800MHz RX7W22-08B333AC RX7W22-08B33348

Dual band 700/800MHz RX7W22-78B333AC RX7W22-78B33348

Class B (Canada)

Single band 700MHz RX7W22-C7B333AC RX7W22-C7B33348

Single band 800MHz RX7W22-C8B333AC RX7W22-C8B33348

Dual band 700/800MHz RX7W22-CFB333AC RX7W22-CFB33348

License

Dual Band (700/800MHz) License RX7W22-L78B333

Page 145 of 232


Critical Point™ Public Safety Bi-Directional Amplifier
RX-4122 PS UHF 400MHz BDA
Features
 Supports P25 P1/P2 digital and conventional analog communications simultaneously
 Simplex and internal Duplexing supported
 Internal dual window filter supported
 Up to 32 narrow band filters (Class A)
 Up to 4 wide band filters (Class B)
 Channelized Auto Level Control (ALC) supported (Class A)
 Channelized uplink squelch supported (Class A)
 Uplink PA shutdown bring the minimum noise for Base Station
 Built-in mandatory isolation test to prevent BDA oscillation
 Auto shutdown with alarm upon oscillation detection
 Web based GUI for intelligent configuration, SNMP supported
 NFPA 1221 / IFC compliant dry contact alarms
 NFPA 1221 / IFC compliant NEMA 4 enclosure
 FCC Class A: PX8-RX4122-A, Class B: PX8-RX4122-B
 UL AC: SGSNA/18/GZ/00076, DC: SGSNA/18/GZ/00075

Specifications

Electrical
Frequency Range MHz 450 - 512
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 36 (TX/RX separate without Filter)
Single Window 2MHz @450-470MHz
Single Window 1MHz @470-512MHz
Dual Window 2MHz + 2MHz @450-470MHz
RF Windows (internal) Dual Window 1MHz + 1MHz @470-512MHz
Dual Window 2MHz@450-470MHz + 1MHz
@470-512MHz
*Note
Maximum System Gain dB 95
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 3
Uplink Noise Figure dB 7
Intermodulation dBm  -13
Spurious dBm FCC Compliance
Maximum RF Input Level without Damage dBm 0
Maximum RF Input Level without Overdrive -10
Input VSWR  1.5
Impedance  50
*Note: Consult for passband and window configurations other than listed above

Page 146 of 232


Class A
Number of Filters 32
Bandwidth: 6.25KHz ≥ 60dBc @ filter center + 60KHz, 35us
Filter Options /
Out-of-Band Suppression Bandwidth: 12.5KHz ≥ 60dBc @ filter center + 65KHz, 35us
/ Bandwidth: 25KHz ≥ 50dBc @ filter center + 75KHz, 27us
System Group Delay
Bandwidth: 75KHz ≥ 60dBc @ filter center + 200KHz, 15us
Class B
Number of Filters 4
Filter Options 200KHz – 5MHz
System Group Delay sec 6.5
≥ 45dBc @ filter edge + 0.6MHz
Out-of-Band Suppression
≥ 60dBc @ filter edge + 1MHz

Mechanical
in(mm
Dimensions, H x W x D 31.5x15.4x12.4 (800×390×315)
)
Weight(without bracket) lb(kg) 77 (35)
VDC -40 to -58
Power Supply
VAC 120
Power Consumption W 85
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature o
F(oC) -27 to +140 (-33 to +60)
Operating Humidity  95%
Environmental Class NEMA 4
Note: Typical specifications at room temperature
Part Numbers
RX4122-XXYYZZFF
XX YY ZZ FF
Unit Class and Filter Power Level (TX/RX Power Supply: Filter Options:
Numbers: separate):
AC – AC powered Various due to different
32 – Class A 32 filters 36 – 36dBm DC – DC Powered filter model
B4 – Class B 4 filters

Outline Drawing

315
390 270
800

Page 147 of 232


Critical Point™ Public Safety Distributed Antenna System
RH-7W22 PS 700/800MHz DAS
Features

 Dual-band configuration supports 700MHz and 800MHz public safety bands


 Supports P25 P1/P2 digital and conventional analog communications simultaneously
 Supports FirstNetTM LTE Band 14 (Class B)
 Up to 32channels (Class A) / 3 sub bands (Class B)
 2W output power per band
 Channelized Auto Level Control (ALC) supported (Class A)
 Channelized uplink squelch supported (Class A)
 Web based GUI for intelligent configuration, SNMP supported
 Built-in mandatory isolation test to prevent oscillation
 NFPA 1221 compliant dry contact alarms on MU/RUs
 NFPA 1221 compliant NEMA4X enclosure for MU/RUs
 FCC/UL approvals pending

Master Unit

Master Unit Remote Unit Remote Unit

Functional Block Diagram

Remote Unit

Master Unit Up to 8

Remote Unit

Page 148 of 232


Specifications
Optical
System 700MHz,800MHz

Optical Fiber Single Mode

Optical Wavelength nm 1550, 1310 + WDM


MU dBm -4 to -2
Optical Output Power
RU dBm 3 to 5
Maximum Optical Loss dB 6.5

Fiber Connectors MU: SC/APC, RU: SC/APC

Electrical (Class A)
700MHz 800MHz
Uplink 799-805 806-824
Frequency Range MHz
Downlink 769-775 851-869
Channel Bandwidth 12.5/25/75KHz 12.5/25/75KHz
Number of Filters 32 32
Total Output Power, Uplink dBm 27
Total Output Power, Downlink 33 33
Maximum System gain dB 95
Gain Adjustment Range (1dB step) dB MU: 0-30, RU: 0-30
Pass Band Ripple (p-p) dB ≤3 ≤3
Spurious emission FCC Compliance FCC Compliance
Inter modulation dBm -13 -13
Uplink Noise Figure at Maximum Gain dB ≤5
System Delay sec 17-37
Max UL Input w/o Overdrive dBm -30
Max UL Input w/o Damage dBm -10
Input VSWR  1.5
Impedance  50

Electrical (Class B)
700MHz 800MHz
Uplink 788-805 806-817
Frequency Range MHz
Downlink 758-775 851-862
Channel Bandwidth 200KHz - 10MHz 200KHz - 10MHz
Number of Filters 3 3
Total Output Power, Uplink dBm 27
Total Output Power, Downlink 33 33
Maximum System gain dB 95
Gain Adjustment Range (1dB step) dB MU: 0-30, RU: 0-30
Pass Band Ripple (p-p) dB ≤3 ≤3
Spurious emission FCC Compliance FCC Compliance
Inter modulation dBm -13 -13
Uplink Noise Figure at Maximum Gain dB ≤5
System Delay sec 8.5
Max UL Input w/o Overdrive dBm -30
Max UL Input w/o Damage dBm -10
Input VSWR  1.5
Impedance  50

Page 149 of 232


Specifications
Mechanical –MU
Dimensions, H x W x D in(mm) 22.4 x 15.4 x 8.5 (570 x 390 x 215)
Weight without Bracket lb(kg) 66 (30)
Power Supply VDC -40 to -58
Power Consumption (approx.) W 100
RF Connectors N-Female, duplex
Fiber Connectors SC/APC
Operating Temperature °C -40 to +55
Operating Humidity ≤ 95%
Ingress protection NEMA 4X
Enclosure Cooling Convection
MTBF 100,000 @ 77 oF

Mechanical –RU
Dimensions, H x W x D in(mm) 22.4 x 15.4 x 8.5 (570 x 390 x 215)
Weight without Bracket lb(kg) 66 (30)
Power Supply VDC -40 to -58
Power Consumption (approx.) W 100
RF Connectors N-Female, duplex
Fiber Connectors SC/APC
Operating Temperature °C
-40 to +55
Operating Humidity ≤ 95%
Ingress protection NEMA 4X
Enclosure Cooling Convection
MTBF 100,000 @ 77 oF
Note: Typical specifications at room temperature
Part Numbers
Product Type Part Number
Class A

MU Dual Band 700/800MHz, 1 to 4 x RUs, DC-48V RH7W22-D7848E4

MU Dual Band 700/800MHz, 1 to 8 x RUs, DC-48V RH7W22-D7848E8

RU Single Band 700MHz, DC-48V RH7W22-R073348

RU Single Band 800MHz, DC-48V RH7W22-R083348

RU Dual Band 700/800MHz, DC-48V RH7W22-R783348

Class B

MU Dual Band 700/800MHz, 1 to 4 x RUs, DC-48V RH7W22-D78B48E4

MU Dual Band 700/800MHz, 1 to 8 x RUs, DC-48V RH7W22-D78B48E8

RU Single Band 700MHz, DC-48V RH7W22-R07B3348

RU Single Band 800MHz, DC-48V RH7W22-R08B3348

RU Dual Band 700/800MHz, DC-48V RH7W22-R78B3348

License (For Class A and Class B)

Dual Band (700/800MHz) License RH7W22-L7833

Page 150 of 232


 mBDA Series Digital
Band Selective
Repeater

Page 151 of 234


mBDA Series Digital Band Selective Repeater
Features

 Up to 3 pass band segments with independent ON/OFF for maximum flexibility.


 Max. 2W total output power.
 Offline isolation detection for easy commissioning.
 Friendly and easy OMT interface via RJ45 connection
 Integrated wireless modem for remote monitoring and control.
 Compatible to Comba generic OMT and CMS platform.
 Waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

Page 152 of 232


700MHz Digital Band Selective Repeater
mBDA-0733
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 703-733
Operation Frequency, Downlink MHz 758-788
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Input Inter modulation
Compliance with 3GPP TS 36.106
Spurious Emission
EVM
ACRR
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm 350 x 220 x 100

Weight (approx.) kg 7

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65


MTBF hr >50,000

Note: Typical specification at room temperature.

Page 153 of 234


900MHz Digital Band Selective Repeater
mBDA-9133
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 885-915
Operation Frequency, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25*
Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Inter modulation
Spurious Emission
EVM Compliance with 3GPP TS 25.106
ACRR
PCDE
Spurious Emission Mask

Out-of-Band Rejection@ Offset ≥ 600KHz ≥ 45


dBc
GSM Offset ≥ 1MHz ≥ 60
Inter modulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361x222x 93/14.2x8.7x3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz.

Page 154 of 232


1800MHz Digital Band Selective Repeater
mBDA-1833
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1710-1785
Operation Frequency, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25*
Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Spurious Emission
EVM
ACRR Compliance with 3GPP TS 36.106
PCDE
Spurious Emission Mask
Inter modulation

Out-of-Band Rejection@ Offset ≥ 600KHz ≥ 45


dBc
GSM Offset ≥ 1MHz ≥ 60
Inter modulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361x222x93/14.2x8.7x3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, LTE Max. Bandwidth 20MHz.

Page 155 of 234


1900MHz Digital Band Selective Repeater
mBDA-1933
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1850-1915

Operation Frequency, Downlink MHz 1930-1995

Operating Bandwidth Per Sub-band MHz 0.2-25*


Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Inter modulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM
Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask

Out-of-Band Rejection@ Offset ≥ 600KHz ≥ 45


dBc
GSM Offset ≥ 1MHz ≥ 60
Inter modulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000
Note: Typical specification at room temperature;
*: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

Page 156 of 232


AWS Digital Band Selective Repeater
mBDA-2033
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1710-1755
Operation Frequency, Downlink MHz 2110-2155
Operating Bandwidth Per Sub-band MHz 3-20*
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Inter modulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000
Note: Typical specification at room temperature;
*: WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

Page 157 of 234


2100MHzDigital Band Selective Repeater
mBDA-2133
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1920-1980
Operation Frequency, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band MHz 0.2-20*
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Inter modulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000
Note: Typical specification at room temperature;
*: WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

Page 158 of 232


2600MHzDigital Band Selective Repeater
mBDA-2633
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 2500-2570
Operation Frequency, Downlink MHz 2620-2690
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Input Inter modulation
Compliance with 3GPP TS 36.106
Spurious Emission
EVM
ACRR
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50

Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7

Weight (approx.) kg/lb 7/15.4

Power Supply VAC 100-240/47-63Hz

Power Consumption (approx.) W 60

Enclosure Cooling Convection

RF Connectors N-Female

Operating Temperature C -33 to +55

Operating Humidity  95%

Environmental Class IP65

MTBF hr >50,000

Note: Typical specification at room temperature.

Page 159 of 234


Combiner for Dual Single Band mBDAs
Features

 Combiner is used for mBDA single band enclosure


 Single in and single out
 Uniform for the whole system
 Easy installation

Specifications-model 1
Electrical Band1 Band2
Operating Frequency (MHz) 806-960 1710-2170

Insert Loss (dB) ≤ 0.8 ≤1

VSWR ≤ 1.5 ≤ 1.5

Note: Typical specification at room temperature;


Specifications-model 2
Electrical Band1 Band2
Operating Frequency (MHz) 1710-1880 1920-2170
Insert Loss (dB) ≤ 1.1 ≤ 1.1
VSWR ≤ 1.5 ≤ 1.5
Note: Typical specification at room temperature;

Mechanical
Dimensions, H x W x D (mm) 210 x 338 x 71
Weight (approx.) (kg) 4.6
RF Connectors N-Female
Operating Temperature (C) -33 to +55
Operating Humidity  95%
Environmental Class IP65

Outline Drawing

102
338
71
210

Combiner

Page 160 of 232


Wall

Master Unit

Slave Unit

Combiner

Final Show-After Combination

Note: mBDA equipments are not included, need order separately.

Page 161 of 234


mBDA Indoor Digital Band Selective Repeater
mBDA-100
Features

 Max. 4 bands of 700/800/900/1800/2100/2600MHz.


 Supports GSM, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via OMT software.
 Friendly and easy OMT interface via RJ45 connection
 Integrated wireless modem or Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not
available between a mobile and a base station. mBDA is ideal for the first phase of the network rollout
and for any subsequent phase where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three
individually adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and
multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring
system via PC or wireless modem to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz LTE 703-733 758-788
800MHz LTE 791-821 832-862
900MHz GSM/WCDMA 930-960 885-915
1800MHz GSM/LTE 1805-1880 1710-1785
2100MHz WCDMA 2110-2170 1920-1980
2600MHz LTE 2620-2690 2500-2570

WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.
LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)

RF Parameter
LTE 700 MHz
RF Parameter DL UL
Frequency Range (MHz) 703-733 758-788
Max Output Power Per Antenna Port1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /

Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

Page 162 of 232


LTE 700 MHz
RF Parameter DL UL
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

LTE 800 MHz


RF Parameter DL UL
Frequency Range (MHz) 791-821 832-862
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

GSM/WCDMA* 900 MHz


RF Parameter DL UL
Frequency Range (MHz) 930-960 885-915
Max Output Power Per Antenna Port1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

Page 163 of 234


GSM/LTE** 1800 MHz
RF Parameter DL UL
Frequency Range (MHz) 1805-1880 1710-1785
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation2 3GPP 3GPP
*WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.
**LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)
1
Intermodulation: WCDMA@3GPP; GSM @Less than-13dBm.
2Intermodulation: LTE@3GPP; GSM @Less than-13dBm.

WCDMA 2100 MHz


RF Parameter DL UL
Frequency Range (MHz) 2110-2170 1920-1980
Max Output Power Per Antenna Port1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5,10,15 5,10,15
Maximum System Gain (dB) 80 80
Pass Band Ripple at 3.84MHz 2 2
System Noise Figure (dB) / 5
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

LTE 2600 MHz


RF Parameter DL UL
Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4

Page 164 of 232


LTE 2600 MHz
RF Parameter DL UL
System Noise Figure (dB) / 5
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

Combiner Specifications
Electrical Band1 Band2 Band3 Band4
Operating Frequency (MHz) 791-960 1710-1880 1920-2170 2500-2690

Insert Loss (dB) ≤ 0.8 ≤ 0.9 ≤ 0.9 ≤ 0.8

VSWR ≤ 1.5 ≤ 1.5 ≤ 1.5 ≤ 1.5

Mechanical Specifications
System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power and Monitor Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, H x W x D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power & Monitoring Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power & Monitoring Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
RF Connectors N Female
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

Page 165 of 234


BDA Indoor Digital Band Selective Repeater
mBDA-200S
Features

 Max. 6 bands of 700UpperC/ 700LowerABC/ 800/850/ 1900/AWS/ EAWS/


2600MHz.
 Supports GSM, CDMA, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via WEB based OMT software.
 Friendly and easy OMT interface via RJ45 connection.
 Support Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not
available between a mobile and a base station. mBDA is ideal for the first phase of the network rollout
and for any subsequent phase where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three
individually adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and
multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring
system via PC to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz Upper C LTE 746-757 776-787
700MHz Lower ABC LTE 728-746 698-716
800MHz (ESMR) CDMA/LTE 862-869 817-824
850MHz GSM/CDMA/WCDMA/LTE 869-894 824-849
1900MHz GSMCDMA/WCDMA/LTE 1930-1995 1850-1915
EAWS WCDMA/LTE 2110-2180 1710-1780
2600MHz LTE 2620-2690 2500-2570

RF Parameters
LTE700MHz Upper C
RF Parameter DL UL
Frequency Range (MHz) 746-757 776-787
Max Output Power Per Antenna Port
27, 30, 33 17
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 1 1
Operating Bandwidth (MHz) 5-11 5-11
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4

Page 166 of 232


LTE700MHz Upper C
RF Parameter DL UL
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

LTE700MHz Lower ABC


RF Parameter DL UL
Frequency Range (MHz) 728-746 698-716
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-18 5-18
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation2 3GPP 3GPP

CDMA/LTE 800 MHz (ESMR)


RF Parameter DL UL
Frequency Range (MHz) 862-869 817-824
Max Output Power Per Antenna Port
27,30,33 17
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-10 0.2-10
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) 8 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation 1
3GPP 3GPP

Page 167 of 234


GSM/CDMA/WCDMA/LTE 850 MHz
RF Parameter DL UL
Frequency Range (MHz) 869-894 824-849
Max Output Power Per Antenna Port
27, 30, 33 23
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
*WCDMA is based on 3GPP TS 25.106 V9.0.0 (2009-12).
**LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)
1
Intermodulation: WCDMA@3GPP; GSM/CDMA@Less than-13dBm.
2Intermodulation: LTE@3GPP; GSM @Less than-13dBm.

RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

RF Parameters
GSM/CDMA/WCDMA/LTE 1900 MHz
RF Parameter DL UL
Frequency Range (MHz) 1930-1995 1850-1915
Max Output Power Per Antenna Port
27, 30, 33 23
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

Page 168 of 232


LTE 2600 MHz
RF Parameter DL UL
Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port
27, 30, 33 17
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-20 5-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

WCDMA/LTE EAWS
RF Parameter DL UL
Frequency Range (MHz) 2110-2180 1710-1780
Max Output Power Per Antenna Port
27, 30, 33 17
1(Composite)
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-20 5-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

Page 169 of 234


Mechanical Specifications
System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, H x W x D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power and Monitor Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power and Monitor Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
700UpperC/700LowerABC/800/850/1900/EAWS
RF Connectors (4.3-10)
2600MHz (N-Female)
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

Appendix I: Combiner Specifications


Electrical Band1 Band2 Band3 Band4
Operating Frequency (MHz) 698-788 824-894 1850-1995 1710-1755&2110-2155

Insert Loss (dB) ≤ 0.7 ≤ 0.7 ≤ 0.8 ≤1

VSWR ≤ 1.6 ≤ 1.6 ≤ 1.6 ≤ 1.6

Mechanical
Dimensions
226.5 x 58.6 x 251, (8.9 x 2.4 x 9.9)
H x W x D, mm (in)
Weight (approx.), kg (lb) 4, (8.8)

RF Connectors 4.3-10Female
Operating Temperature ,  C
-20 to +40 (68 to 104)
(F)
Operating Humidity 85%

Environmental Class IP30

Note: Typical specification at room temperature;

Page 170 of 232


Appendix II: Ordering Information
Module Name P/N
RACK mBDA RACK Unit mBDA-RACK-E01
PMU mBDA Power and Monitor Unit mBDA-PMU-A92W300
mBDA DT Combiner mBDA-CB-ABPK4ID1
COMBINER UNIT
mBDA MT Combiner mBDA-CB-ABPK4ID2
700MHz Lower ABC mBDA RF Unit, 0.5W mBDA-RF-7LP27Q
700MHz Lower ABC mBDA RF Unit, 2W mBDA-RF-7LP33Q
700MHz Upper C mBDA RF Unit, 0.5W mBDA-RF-7UP27Q
700MHz Upper C mBDA RF Unit, 2W mBDA-RF-7UP33Q
800MHz mBDA RF Unit, 0.5W mBDA-RF-80P27Q
800MHz mBDA RF Unit, 2W mBDA-RF-80P33Q
850MHz mBDA RF Unit, 0.5W mBDA-RF-85P27Q
RF UNIT
850MHz mBDA RF Unit, 2W mBDA-RF-85P33Q
1900MHz mBDA RF Unit, 0.5W mBDA-RF-19P27Q
1900MHz mBDA RF Unit, 2W mBDA-RF-19P33Q
EAWS mBDA RF Unit, 0.5W mBDA-RF-EAWSP27Q
EAWS mBDA RF Unit, 2W mBDA-RF-EAWSP33Q
2600MHz mBDA RF Unit, 0.5W mBDA-RF-26P27
2600MHz mBDA RF Unit, 2W mBDA-RF-26P33

Page 171 of 234


mBDA Digital Band Selective Repeater
mBDA-200SS
Features

 Max. 6 bands of700UpperC/700LowerABC/800/850/1900/EAWS/2600MHz


 Supports GSM, CDMA,WCDMA, and LTE operating
 Supports multi operator configurations and up to 3 sub bands per band
 Operation via WEB based OMT software
 Friendly and easy OMT interface via RJ45 connection
 Support Ethernet for remote monitoring and control

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not
available between a mobile and a base station. mBDA is ideal for the first phase of the network rollout
and for any subsequent phase where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three
individually adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and
multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring
system via PC to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz Upper C LTE 746-757 776-787
700MHz Lower ABC LTE 728-746 698-716
800MHz (ESMR) CDMA/LTE 862-869 817-824
850MHz GSM/CDMA/WCDMA/LTE 869-894 824-849
1900MHz GSMCDMA/WCDMA/LTE 1930-1995 1850-1915
EAWS LTE 2110-2180 1710-1780
2600MHz LTE 2620-2690 2500-2570

Page 172 of 232


RF Parameters
LTE700MHz Upper C
RF Parameter DL UL
Frequency Range (MHz) 746-757 776-787
Max Output Power Per Antenna Port1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 1 1
Operating Bandwidth (MHz) 5-11 5-11
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

LTE700MHz Lower ABC


RF Parameter DL UL
Frequency Range (MHz) 728-746 698-716
Max Output Power Per Antenna Port1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-18 5-18
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation2 3GPP 3GPP

CDMA/LTE 800 MHz (ESMR)


RF Parameter DL UL
Frequency Range (MHz) 862-869 817-824
Max Output Power Per Antenna Port1(Composite) 27,30,33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-10 0.2-10
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4

Page 173 of 234


CDMA/LTE 800 MHz (ESMR)
RF Parameter DL UL
System Noise Figure (dB) 8 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

GSM/CDMA/WCDMA/LTE 850 MHz


RF Parameter DL UL
Frequency Range (MHz) 869-894 824-849
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
*WCDMA is based on 3GPP TS 25.106 V9.0.0 (2009-12).
**LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)
1Intermodulation: WCDMA@3GPP; GSM/CDMA@Less than-13dBm.

2
Intermodulation: LTE@3GPP; GSM @Less than-13dBm.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

GSM/CDMA/WCDMA/LTE 1900 MHz


RF Parameter DL UL
Frequency Range (MHz) 1930-1995 1850-1915
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

Page 174 of 232


RF Parameters
WCDMA/LTE EAWS
RF Parameter DL UL
Frequency Range (MHz) 2110-2180 1710-1780
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-20 5-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

LTE 2600 MHz


RF Parameter DL UL
Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 5-20 5-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (usec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation 1
3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max.Bandwidth 15MHz, LTE Max.Bandwidth 20MHz.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

Page 175 of 234


Mechanical Specification
System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, H x W x D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power and Monitor Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power and Monitor Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
700UpperC/700LowerABC/800/850/1900/EAWS
RF Connectors (4.3-10)
2600MHz (N-Female)
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

Appendix I: Combiner Specification


Electrical Band1 Band2 Band3 Band4
Operating Frequency (MHz) 698-788 824-894 1850-1995 1710-1755&2110-2155

Insert Loss (dB) ≤ 0.7 ≤ 0.7 ≤ 0.8 ≤1

VSWR ≤ 1.6 ≤ 1.6 ≤ 1.6 ≤ 1.6

Mechanical
Dimensions, H*W*D, mm (in) 226.5x58.6x251, (8.9x2.4x9.9)

Weight (approx.), kg (lb) 4, (8.8)

RF Connectors 4.3-10Female
Operating Temperature ,
-20 to +40 (68 to 104)
C(℉)
Operating Humidity 85%

Environmental Class IP30

Note: Typical specification at room temperature;

Page 176 of 232


Appendix II: Ordering Information
Module Name P/N
RACK mBDA RACK Unit mBDA-RACK-E01

PMU mBDA Power and Monitor Unit mBDA-PMU-A92W300

mBDA DT Combiner mBDA-CB-ABPK4ID1


COMBINER UNIT
mBDA MT Combiner mBDA-CB-ABPK4ID2

700MHz Lower ABC mBDA RF Unit, 0.5W mBDA-RF-7LP27Q

700MHz Lower ABC mBDA RF Unit, 2W mBDA-RF-7LP33Q

700MHz Upper C mBDA RF Unit, 0.5W mBDA-RF-7UP27Q

700MHz UpperC mBDA RF Unit, 2W mBDA-RF-7UP33Q

800MHz mBDA RF Unit, 0.5W mBDA-RF-80P27Q

800MHz mBDA RF Unit, 2W mBDA-RF-80P33Q

850MHz mBDA RF Unit, 0.5W mBDA-RF-85P27Q


RF UNIT
850MHz mBDA RF Unit, 2W mBDA-RF-85P33Q

1900MHz mBDA RF Unit, 0.5W mBDA-RF-19P27Q

1900MHz mBDA RF Unit, 2W mBDA-RF-19P33Q

EAWS mBDA RF Unit, 0.5W mBDA-RF-EAWSP27Q

EAWS mBDA RF Unit, 2W mBDA-RF-EAWSP33Q

2600MHz mBDA RF Unit, 0.5W mBDA-RF-26P27

2600MHz mBDA RF Unit, 2W mBDA-RF-26P33

Page 177 of 234


mBDA Indoor Digital Band Selective Repeater
mBDA-300
Features

 Max. 4 bands of 700(APT) 850/1800 (or 1900)/2100 (or AWS)/2600MHz.


 Supports GSM, CDMA, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via OMT software.
 Friendly and easy OMT interface via RJ45 connection.
 Integrated wireless modem or Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not
available between a mobile and a base station. mBDA is ideal for the first phase of the network rollout
and for any subsequent phase where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three
individually adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and
multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring
system via PC or wireless modem to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz* LTE 758-788/773-803 703-733/718-748
850MHz GSM/CDMA/WCDMA** 869-894 824-849
1800MHz GSM/LTE 1805-1880 1710-1785
1900MHz GSMCDMA/WCDMA** 1930-1995 1850-1915
AWS WCDMA/LTE 2110-2155 1710-1755
2100MHz WCDMA/LTE** 2110-2170 1920-1980
2600MHz LTE 2620-2690 2500-2570
*700MHz is APT band, 2 options as 703-733/758-788 and 718-748/773-803.
**WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.

Page 178 of 232


RF Parameters
LTE 700A
RF Parameter DL UL
Frequency Range (MHz) 758-788 703-733
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

LTE 700B
RF Parameter DL UL
Frequency Range (MHz) 773-803 718-748
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 0.2-24.8
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

GSM/CDMA/WCDMA 850 MHz


RF Parameter DL UL
Frequency Range (MHz) 869-894 824-849
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

Page 179 of 232


GSM/CDMA/WCDMA 850 MHz
RF Parameter DL UL
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

GSM/LTE 1800 MHz


RF Parameter DL UL
Frequency Range (MHz) 1805-1880 1710-1785
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation 2
3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz; WCDMA Max. Bandwidth 15MHz; LTE Max. Bandwidth 20MHz.
1Intermodulation: WCDMA @ 3GPP; GSM/CDMA @ Less than-13dBm.
2
Intermodulation: LTE @ 3GPP; GSM @ Less than-13dBm.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.5dB.

GSM/CDMA/WCDMA 1900 MHz


RF Parameter DL UL
Frequency Range (MHz) 1930-1995 1850-1915
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 23
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation1 3GPP 3GPP

Page 180 of 232


RF Parameters
WCDMA/LTE 2100 MHz
RF Parameter DL UL
Frequency Range (MHz) 2110-2170 1920-1980
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

WCDMA/LTE AWS
RF Parameter DL UL
Frequency Range (MHz) 2110-2155 1710-1755
Max Output Power Per Antenna Port 1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

System Group Delay (sec) 6 6


Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Inter modulation 3GPP 3GPP

LTE 2600 MHz


RF Parameter DL UL
Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17
2 Carriers -3 /
4 Carriers -6 /
8 Carriers -9 /
Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5

Page 181 of 232


LTE 2600 MHz
RF Parameter DL UL
System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP
Intermodulation 3GPP 3GPP
Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
1Intermodulation: WCDMA @ 3GPP; GSM/CDMA @ Less than-13dBm

RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.5dB.

Mechanical Specifications
System Rack (4 bands) 267 x482 x 485, (10.5 x 19 x19.1)
Power Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, Hx Wx D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power and Monitor Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power and Monitor Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec)
180
(approx.)
Enclosure Cooling Convection or Fan
RF Connectors N Female
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

Page 182 of 232


 MP Series Digital Pico
Repeater

Page 183 of 232


MP Series Digital Pico Repeater
Features

 Bandwidth adjustable for both downlink and uplink.


 Max.2 pass band segments with independent ON/OFF for maximum flexibility.
 Max. 20dBm total output power.
 Offline isolation detection for easy commissioning.
 Low noise amplifier improves system noise figure for better voice quality and
reduced drop call.
 Highly integrated design with miniaturized enclosure, small size, light weight and
easy to install.
 Includes Modem for remote monitoring (option).
 Compatible to Comba generic OMT and CMS platform.

Block Diagram

Page 184 of 232


800MHz Digital Pico Repeater
MP-0832
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 832-862
Operation Frequency, Downlink MHz 791-821
Instantaneous Bandwidth MHz 30
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Inter modulation Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature

Page 185 of 232


850MHz Digital Pico Repeater
MP-8132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 824-849
Operation Frequency, Downlink MHz 869-894
Instantaneous Bandwidth MHz 25
Operating Bandwidth Per Sub-band* MHz 0.2-24.8
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Inter modulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature
*: GSM Max. Bandwidth 24.8MHz, WCDMA, LTE Max. Bandwidth 20MHz

Page 186 of 232


900MHz Digital Pico Repeater
MP-9132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 880-915
Operation Frequency, Downlink MHz 925-960
Instantaneous Bandwidth MHz 35
Operating Bandwidth Per Sub-band* MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Inter modulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 187 of 232


1800MHz Digital Pico Repeater
MP-1832
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1710-1785
Operation Frequency, Downlink MHz 1805-1880
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band* MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
System Group Delay sec ≤6
Spurious Emission Mask
Inter modulation Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature
*: GSM Max. Bandwidth 25MHz, LTE Max. Bandwidth 20MHz

Page 188 of 232


1900MHz Digital Pico Repeater
MP-1932
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1850-1910
Operation Frequency, Downlink MHz 1930-1990
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Inter modulation
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature
*: GSM Max. Bandwidth 25MHz; WCDMA, LTE Max. Bandwidth 20MHz

Page 189 of 232


2100MHz Digital Pico Repeater
MP-2132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1920-1980
Operation Frequency, Downlink MHz 2110-2170
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Inter modulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature

Page 190 of 232


2600MHz Digital Pico Repeater
MP-2632
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 2500-2570
Operation Frequency, Downlink MHz 2620-2690
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 36.106
Inter modulation
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 198 x 78 x 43

Weight (approx.) kg 0.5

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 14

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature

Page 191 of 232


Multi-band Digital Pico Repeater
Features

 2 or 3 bands configuration in one system


 Bandwidth adjustable for both downlink and uplink.
 Max.2 pass band segments with independent ON/OFF for maximum flexibility.
 17 or 20dBm total output power.
 Offline isolation detection for easy commissioning.
 Low noise amplifier improves system noise figure for better voice quality and
reduced drop call.
 Highly integrated design with miniaturized enclosure, small size, light weight and
easy to install.
 Includes Modem for remote monitoring (option).
 Compatible to Comba generic OMT and CMS platform.

Functional Block Diagram

Page 192 of 232


Dual-band Digital Pico Repeater
MP-7V32
Specifications-17dBm
Electrical 800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1920-1980
Operation Frequency, Downlink MHz 791-821 2110-2170
Instantaneous Bandwidth MHz 30 50
Operating Bandwidth Per Sub-band MHz 3-20 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 26

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
.

Page 193 of 232


Specifications-20dBm
Electrical 800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1920-1980
Operation Frequency, Downlink MHz 791-821 2110-2170
Instantaneous Bandwidth MHz 30 50
Operating Bandwidth Per Sub-band MHz 3-20 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 30

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
.

Page 194 of 232


Dual-band Digital Pico Repeater
MP-7532
Specifications-17dBm
Electrical 900MHz 1800MHz
Operating Frequency, Uplink MHz 880-915 1710-1785
Operation Frequency, Downlink MHz 925-960 1805-1880
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106 and
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 26

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 195 of 232


Specifications-20dBm
Electrical 900MHz 1800MHz
Operating Frequency, Uplink MHz 880-915 1710-1785
Operation Frequency, Downlink MHz 925-960 1805-1880
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 30

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 196 of 232


Dual-band Digital Pico Repeater
MP-7632
Specifications-17dBm
Electrical 900MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1920-1980
Operation Frequency, Downlink MHz 925-960 2110-2170
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 25.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 26

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 197 of 232


Specifications-20dBm
Electrical 900MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1920-1980
Operation Frequency, Downlink MHz 925-960 2110-2170
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 25.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 26

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 198 of 232


Dual-band Digital Pico Repeater
MP-7832
Specifications-17dBm
Electrical 1800MHz 2100MHz
Operating Frequency, Uplink MHz 1710-1785 1920-1980
Operation Frequency, Downlink MHz 1805-1880 2110-2170
Instantaneous Bandwidth MHz 50 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Inter modulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 30

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 199 of 232


Tri-band Digital Pico Repeater
MP-5K32
Specifications
Electrical 800MHz 900MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 880-915 1920-1980
Operation Frequency, Downlink MHz 791-821 925-960 2110-2170
Instantaneous Bandwidth MHz 30 35 50
Operating Bandwidth Per Sub-band* MHz 3-20 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4 4
System Group Delay sec ≤6
Spurious Emission Mask Compliance Compliance
Compliance with 3GPP TS with 3GPP TS
Inter modulation with 3GPP TS 25.106 25.106
36.106 3GPP TS 3GPP TS
EVM 36.106 36.106
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 38

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 200 of 232


Tri-band Digital Pico Repeater
MP-5232
Specifications-17dBm
Electrical 900MHz 1800MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1710-1785 1920-1980
Operation Frequency, Downlink MHz 925-960 1805-1880 2110-2170
Instantaneous Bandwidth MHz 35 50 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4 4
System Group Delay sec ≤6
Spurious Emission Mask Compliance
Compliance
Compliance with 3GPP TS
with 3GPP TS
Inter modulation with 3GPP TS 25.106
25.1063GPP TS
36.106 3GPP TS
EVM 36.106
36.106
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x 55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 38

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -10 to +40

Operating Humidity 85%

Environmental Class IP30

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 201 of 232


Tri-band Digital Pico Repeater
MP-5832
Specifications
Electrical 800MHz 1800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1710-1785 1920-1980
Operation Frequency, Downlink MHz 791-821 1805-1880 2110-2170
Operating Bandwidth Per Sub-band* MHz 3-20 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4 4
System Group Delay sec ≤6
Spurious Emission Mask Compliance
Compliance Compliance with 3GPP TS
Inter modulation with 3GPP TS with 3GPP TS 25.106
36.106 36.106 3GPP TS
EVM 36.106
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50

Mechanical
Dimensions, W x H x D mm 316 x 224 x55

Weight (approx.) kg 3

Input VAC 100-240/50-60Hz


External Power Supply Unit
Output VDC 12

Power Consumption W 38

Enclosure Cooling Convection

Connectors SMA-Female

Operating Temperature °C -20 to +45

Operating Humidity 85%

Environmental Class IP40

MTBF hr  50,000

Remote Monitoring (option) Built in WCDMA Modem


Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 202 of 232


LTE1800 ICS Pico Repeater
SN-1823
Features

 Support s 5/10/15/20MHz bandwidth in 20MHz pass band, independent gain


control per channel.
 Plug and play.
 Built-in donor antenna and service antenna.
 Support external donor antenna and service antenna.
 System gain up to 85dB with external donor antenna.
 Uplink Noise Control functions to reduce uplink interference.
 Interference Cancellation System (ICS) to reduce the isolation requirement up to
30dB.
 Light chassis and light weight.

Specifications
Electrical 0.02W
Frequency Range, Uplink MHz 1710-1785

Frequency Range, Downlink MHz 1805-1880


Instantaneous Bandwidth MHz 20

Operating Bandwidth MHz 5/10/15/20


Total Output Power, Uplink dBm 13
Total Output Power, Downlink dBm 13
Maximum System Gain, External Donor Antenna dB 85
Maximum System Gain, Built-in Donor Antenna dB 70

Gain Control Range (0.5dB step) dB 30


AGC Control Range dB 30

Gain Flatness (Peak to peak) dB 3


Error Vector Magnitude  8%
Interference Cancellation dB 30
Out of Band Gain
Spurious Emissions
3GPP TS 36.106
Input / Output Inter modulation
Adjacent Channel Rejection Ratio

Uplink Noise Figure, Max. Gain dB 5


System Group Delay sec 6
Input VSWR  1.8
Impedance  50

Page 203 of 232


Mechanical
Dimensions, H x W x D mm 189 x 170 x 67
Weight(approx.) kg 1.2

Power Supply VAC 100-240/50-60Hz


Power Consumption(approx.) W 10

Enclosure Cooling Convection

RF Connectors, for External Antenna SMA-F


PC Control Interface USB

Operating Temperature C -10 to +40


Operating Humidity  85%
Environmental Class IP30
Input RSSI, AGC Alarm, Isolation Alarm, Power On,
LED Indicator
Sleep, Output
Note: Typical specification at room temperature;*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

Page 204 of 232


 Home Small Cell

Page 205 of 234


Home Small Cell
HNB-35,A01
 8 Active Users 24 RRC connected user
 Home Small Cell
 Smart Integrated MIMO Antenna

Comba Home Small Cell Solution


LTE Home Small Cell provides cellular indoor coverage via broadband IP backhaul. It is suitable for small
hotspot indoor scenarios like home, small enterprise, office, business hall, Internet café, solving cellular
network issues including weak coverage, low data rate and site acquisition. It increases capacity for data
service and offloads macro network by absorbing traffic from indoor hotspots.

The Comba LTE Small Cell solution includes Home Small Cell, Gateway and NMS (Network
Management System). The architecture is shown in figure1.

Application Scenarios

 In-building coverage
 In-building data offload
 Home, Small Enterprise wireless broadband
 Small public hotspots
 Emergency coverage

Product Features

 Extends LTE mobile coverage to small, hard-to-reach areas


 Supports up to 8 active users and 24 RRC connected users, ideal for small home/office, and small
public hotspots
 Backhaul through fixed broadband; avoid CAPEX acquiring and building new sites, reduce OPEX
on backhaul transmission, power and operations
 Support CSFB\VOLTE
 Remote control and management through Network Management System (NMS), including software
upgrades and service activation

Page 206 of 232


Technical Specification
Electrical Specifications
Operating Frequency(MHz)
Band TDD/FDD Uplink(MHz) Downlink(MHz)
3 FDD 1710-1785 1805-1880

RF Specifications
Bandwidth/Carrier 10/20 MHz
Max. Total Output Power 100mW 2x2 MIMO
DL=149Mbps, UL=50Mbps;
Max Capacity
8 active users, 24 RRC users
Sensitivity -93.5 dBm
Listening band Band1, band3 and band7
Air interface
Synchronization
IEEE 1588 ACR
Emission Mask
Spurious Emission Compliant to 3GPPTS 36 104
Inter-modulation

Power, Mechanical and Environmental Specifications


Dimension 200mm ×152mm×58mm
Weight < 1.0kg
Power Supply +12V DC Input(Power Adaptor)
Power Consumption <15W
Mounting Method Desk top
Operating Temperature -5Cto +40C
Cooling Method Natural
Operating Humidity 10% to 90%
Storage Temperature -40Cto 65C
IP Rating IP30

Product Interface
Interface Function
WAN RJ45
( Electrical Port) 100/1000M Ethernet for backhaul
RJ45
LAN
10/100M for Fast Ethernet and Local Commissioning
Power Supply interface
POWER
+12V DC input
ON/OFF Power on/off switch
RESET Reset to manufacture setting

Page 207 of 232


Enterprise PiCO
ENB-35L
 64 Active Users
 Standalone Small Cell
 Smart Integrated MIMO Antenna

Enterprise PiCO Solution


Enterprise PiCO can provide cellular indoor coverage via broadband IP backhaul. It is suitable for small
hotspot indoor scenarios like enterprise, office, business hall, Internet café, solving cellular network
issues including weak coverage, low data rate and site acquisition. It increases capacity for data service
and offloads macro network by absorbing traffic from indoor hotspots.

The Comba Enterprise PiCO solution includes Small Cell, Gateway and NMS (Network Management
System). The architecture is shown in figure1.

Application Scenarios

 In-building coverage
 In-building data offload
 Small Enterprise wireless broadband
 Public hotspots
 Emergency coverage

Product Features

 Extends LTE mobile coverage to small, hard-to-reach areas


 Supports up to 64 active users, ideal for small home/office, and small public hotspots
 Backhaul through fixed broadband; avoid CAPEX acquiring and building new sites, reduce OPEX
on backhaul transmission, power and operations
 Standard open interface enables easy integration with other vendors’ network elements
 Support CSFB\VOLTE
 Remote control and management through Network Management System (NMS), including software
upgrades and service activation

Page 208 of 232


Technical Specification
Electrical Specifications
Operating Frequency(MHz)
Band TDD/FDD Uplink(MHz) Downlink(MHz)
1 FDD 1920-1980 2110-2170
3 FDD 1710-1785 1805-1880
7 FDD 2500-2570 2620-2690
40 TDD 2320-2370

RF Specifications
Bandwidth/Carrier 5/10/15/20 MHz
Max. Total Output Power 24dBm
Sensitivity -93.5 dBm
Emission Mask
Spurious Emission Compliant to 3GPP TS 36 104
Inter-modulation

Power, Mechanical and Environmental Specifications


Dimension < 2L
RJ45
Interface
(WAN & Power Supply)
Weight < 1kg
PoE + or
Power Supply
+12V DC Input(Power Adaptor)
Power Consumption < 14W
Mounting Method Ceiling mounting or Wall mounting
Operating Temperature -5C to + 40C
Cooling Method Natural
Operating Humidity 15% to 85%
Storage Temperature -40C to 65C
IP Rating IP20

Product Interface
Interface Function
WAN(Optical Port) SFP, Optical Port for backhaul
WAN(Electrical Port) RJ45, Gigabit-Ethernet interface, backhaul & POE+ Power Supply
LAN RJ45, 100Mbps Fast Ethernet, Local Commissioning port
SIM SIM Card Interface, for Equipment authorization
POWER Power Supply interface, +12V DC input
GPS SMA, GPS Frequency and Time Synchronization input
Reserved Port RJ45, Reserved

Page 209 of 232


PolyCell Solution
Solution Description
PolyCell is composed of CP (Center Point) and DP (Distributed Point) and CK (Center Kernel), providing
cellular indoor coverage via broadband IP backhaul. It is suitable for small-to-medium indoor scenarios
like enterprise, office, business hall, Internet café, solving cellular network issues including weak
coverage, low data rate and site acquisition. It increases capacity for data service and offloads macro
network by absorbing traffic from indoor hotspots or buildings.

CK is the kernel point of PolyCell for centralized signal processing and control. It connects to EPC for S1
signaling processing.

CP is the center point of PolyCell system for distributed signal processing, routing and broadcasting. To
upper level, it connects to CK. To lower level, it connects to sub level CP via optical cable (Daisy Chain
connection) or/and connects to DP via Ethernet cable.

DP is the distributed point for cellular signal broadcasting. DP is directly connecting to CP with PoE+
(Power over Ethernet) rolling.

Main Features
 Support 5MHz/10MHz/15MHz/20MHz bandwidth
 Flexible solution for small-to-medium scenarios
 IP-based backhaul, easy site acquisition
 Plug and play, PoE+ power supply and IT Network-like deployment
 Self-configuration and self-optimization
 End-to-End control and management through Network Management System (NMS)
 Software/hardware failure detection and recover
 Intelligent power Saving

Application Scenarios

 Small-to-Medium in-building coverage


 In-building data offload
 Enterprise wireless broadband
 Emergency Telecommunications Service

Page 210 of 232


General Specification
DP(Distributed Point)
 Mini Distributed Point with internal antenna for LTE MIMO (2T2R)
 Active Component: RF power software controllable, PoE+
 Supporting FDD-LTE, TDD-LTE or UMTS
 Supporting Band 1/2/3/4/7/40 (other bands can be customized)
 Signaling control and processing
 Remote control and monitoring
CP (Center Point)
 Eight RJ45 for DP connection
 Four SFP ports for daisy chain connecting
 Software defined Switch & Converge & Processing
 PSU(Power Supply Unit) for PoE+ supply

CK(Cell Kernel)
 Cloud RAN Design for Cell signal provision
 GPS/1588V2 Synchronization
 Electrical/Optical backhaul interface
 Flexible capacity upgrade: Carrier Aggregation(CA)/Cell Splitting
Ubiquitous Coverage

Page 211 of 232


DP (Distributed Point)
Product Description
Through Cat5E or above cable, DP (Distributed Point) connects to CP (Center Point) and
serves as active cellular signal provision. Different DPs servers as an ideal solution for
small-to-medium scenario coverage.

Product Features

 Extend LTE coverage to hard-to-reach areas


 LTE 5MHz/10MHz/15MHz/20MHz
 LTE MIMO 2 x 2 with interated Antenna
 Support 2 UMTS Carriers(Optional)
 Remote control and management through Network Management System (NMS), including software
upgrade, power configuration, alarm etc.
 Plug and play, PoE+ power supply and IT Network-like deployment.
 The distance between CP and DP can up to 100m by Cat5E or above cable

Technical Specification
Electrical Specifications
Operating Frequency(MHz)
Band TDD/FDD/UMTS Uplink(MHz) Downlink(MHz)
1 FDD/UMTS 1920-1980 2110-2170
2(PCS) FDD/UMTS 1850-1910 1930-1990
3 FDD 1710-1785 1805-1880
4(AWS) FDD/UMTS 1710-1755 2110-2155
7 FDD 2500-2570 2620-2690
40 TDD 2300-2370

RF Specifications
RF Module LTE UMTS
Support Bandwidth(MHz) 5/10/15/20 5 x 2(Carriers)
Max. Total Output Power 24dBm(2x2 MIMO) 23dBm(SISO, 2Carriers)
Sensitivity -93.5 dBm @20MHz N/A
Output Power Accuracy ±2dB ±2dB
Output Power Range 20dB N/A
Emission Mask
Compliant to 3GPP TS 36 104
Spurious Emission 3GPP TS 25.106
FCC
Inter modulation

Page 212 of 232


Technical Specification
Power, Mechanical and Environmental Specifications
6.7” x 6.7” x 1.8” (Single Mode)
(170mm x 170m x 46 mm)
Dimension (L x W x H)
8.3” x 8.3” x 1.8” (Dual Mode)
(210mm x 210m x 46 mm)
Interface RJ45 * 2
Weight < 0.5kg(Single Mode) < 0.8kg(Dual Mode)
Power Supply PoE+
Power Consumption < 10W(Single Mode) < 18W(Dual Mode)
Mounting Method Ceiling mounting or Wall mounting
Operating Temperature -5C to +45C
Cooling Method Natural
Operating Humidity 15% to 85%
Storage Temperature -40C to 65C
IP Rating IP20

Page 213 of 232


CP (Center Point)
Product Description
CP (Center Point) is the center processing part
of PolyCell. It can greatly increase the Small Cell
coverage by daisy chain connection. Meanwhile,
it can switch, converge and compress the data for better Ethernet transition.

Product Features

 8 extension ports (RJ45) for DP direct connection


 4 level daisy chain connecting, extend the transmission distance up to 5km
 PoE+ power supply
 Signal switch, convergence and compress
 NMS/EMS for remote management, including software downloading, upgrade, alarm, KPI report etc
 1U size, easy installation on rack or wall mount

Technical Specification
Interfaces of CP
LAN1 LMT(Local Management Terminal 1, RJ45)
SFP1 Optical port to signal source 1
SFP2 Optical port to signal source 2
SFP3 Optical port for CP daisy chain
SFP4 Reserved
ETH1~ETH8 DP Connection Port, 8 x1000Mbps RJ45, software configurable
Power Socket AC:100V - 240V (47Hz - 63Hz)
ON/OFF Switch Power supply ON/OFF switch

Power, Mechanical, and Environmental Specifications


Total Dimension (L x W x H) 300mm x 240mm x 44mm
Weight < 3kg
Power Supply AC: 110/220V (47Hz - 63Hz)
Mounting Method Rack mounting or Wall mounting
Operating Temperature -5C to 40C
Cooling Method Natural
Storage Temperature -40C to 65C
Operating Humidity 15% to 85% (no condensation)
IP Rating IP30

Page 214 of 232


CK (Cell Kernel)
Product Description
CK is a part of PolyCell solution which connects to core
network through IP interface and provides cellular signal
for users. It is mainly used in small-to-medium sized scenarios.
It actualizes ubiquitous coverage, improves its capability for
data service, and offloads macro network by absorbing traffic of hotspots.

Product Features

 LTE 5MHz/10MHz/20MHz bandwidths


 Wireless resource management, including congestion control, UE access control, power control,
ICIC etc
 Various synchronization: air sniffer,1588V2 and GPS clock synchronization
 Flexible IP backhaul such as Ethernet, PON or PTN etc
 Support NMS management function, including remote software downloading upgrade, alarm, KPI
report etc.
 1U size, easy installation on rack or wall mount

Technical Specification
System Specifications
Supported Users(LTE) 200 active users Or 400 RRC users
Input Signal range: -12±5 dBm
UMTS CK Feature
Downlink Gain: 35dB Uplink Gain : 35dB
1 x RJ45 Port to WAN
1 x RJ45 Port to LAN
1 x RJ45 Port for Debug
1 x RJ45 Port to GPS
Interface 2 x SFP Port to CP
1 x SFP Port to WAN
1 x SFP Reserved
Power Switch
Mobility Handover and reselection with Macro Cell and other Small Cell
Synchronization Support 1588v2/GPS/A-GPS

Power, Mechanical, and Environmental Specifications


440mm x 370mm x 44mm(LTE)
Dimension(H x W x D)
482mm x 360mm x 44mm(UMTS)
Weight < 6.5kg
Power Supply External AC/DC adaptor 110/240-VAC
Power Consumption 45W
Mounting method Free standing, wall mounting
LAN Interface 100Mbps Ethernet port
LED Indicators POWER/RUN/LTE(UMTS) Traffic /GPS STATUS
Operating Temperature -5C to +40C
Operating Humidity 15% to 85%
IP Rating IP30

Page 215 of 232


GSM IP-Base Station
GSM RRU: ENB-10A57R
GSM BBU: ENB-10A57

GSM IP-Base Station Solution


GSM IP-Base Station (BBU+RRU) Solution is a high power outdoor solution based on IP architecture,
which can be easily deployed for outdoor coverage.

RRU is the Remote Radio Unit, by connecting to BBU (Base Band Unit), it can provide high power GSM
coverage.
BBU is the Base Band Unit, it connects to GSM core network by IP based interface and connects to
RRU by optical fiber, providing base band signal to RRU and cellular signaling & data to GSM core
network.

Application Scenarios

 Rural area coverage


 Large venue coverage
 Emergency coverage
 Indoor distributed system

Product Features
Flexible Configuration/Deployment
 Various backhaul options: Wired backhaul, satellite backhaul, Wi-Fi mesh backhaul, PON,
Microwave and others based on IP
 Cascade or star connection supported
Cost-effective design, lower CAPEX and OPEX
 IP based for lower transmission request
 Easy installation and deployment
 Self-optimization and configuration
 Remote control and management
 Robust outdoor design, never goes down

GSM IP-Base Station System Architecture

Page 216 of 232


RRU
ENB-10, A57R
 GSM 900
 1T2R, 40W Output
 Full outdoor Design

Technical Specification
Radio Specifications
GSM 900 Band
Operating frequency UL: 885-909 MHz
DL: 930-954 MHz
Channel spacing 200 kHz
GSM carriers 4 Carriers
40W
Maximum output power 46dBm@1ch ; 43dBm@2ch
31dBm@3ch ; 40dBm@4ch
Reference sensitivity level ≤ -104 dBm
Clock Precision ±0.05ppm
VSWR in RF port < 1.5

Power, Mechanical & Environmental Specifications


Dimensions, H x W x D 500 mm × 250 mm × 155 mm
Weight (approx.) 20kg
AC:155V - 285V
Power supply DC:-72V - -36V
(Different Module)
Power consumption (approx.) 320 W
Mount Pole or wall mount
Operating temperature -40°C to +55 °C
Operating humidity <95%
IP level IP65

Interface
Port Type Note
TX1/RX1 N-Female Tx and Rx Main Path
RX2 N-Female Rx diversity input port
OP1, Optical WAN (SFP)
OP2 Optical For Daisy Chain (SFP)
POWER 2 Pin AC/DC input power
ALARM 7Pin 7 pin alarm interface
ON/MOV 5Pin Reserved port
WAN RJ45 WAN (RJ45)

Page 217 of 232


BBU
ENB-10, A57
 GSM/EDGE/GRPS
 IP-Based Backhaul
 4 Carriers
 Full outdoor Compact Design

Specifications
GSM Specifications
Number of carriers 4 Carriers (Max 2 EDGE Carriers)
TR069 to NMS
Interface protocol
CPRI to RRU
CS service FR,EFR & SMS
GPRS service CS1~CS4 Coding Scheme
EDGE service MCS1~MSC9 Coding Schemes
Synchronization GPS /IEEE 1588V2
IP SeC Encryption
Security
EAP-AKA Authentication
Power, Mechanical, and Environmental Specifications
Dimensions, H x W x D 420mm × 290mm × 70mm
Weight (approx.) 10kg
AC:156V - 284V
Power supply DC:-57V - -40V
(Different Module)
Power consumption 60 W (approx.)
Mount Pole, Wall
Operating temperature -40°C to +45 °C
Operating humidity <95%
IP level IP55

Interface
Name Type Function
WAN1 RJ45 IP backhaul to GSM gateway
WAN2 Optical (SFP) IP backhaul to GSM gateway
LAN RJ45 Reserved Port
RU1 - RU3 Connect to RRU
RU1~5 Optical SFP)
RU4 - RU5 Daisy Chain connection to BBU
POWER Power Socket 2 pin Interface
LMT RJ45 Local Debug
RST Button Reset Button
GPS N-Female GSP signal connection
OUT-ALM RJ45 External alarm interface

Page 218 of 232


LTE eNodeB
System Description
Comba LTE eNodeB System is composed of BBU and RRU, providing cellular coverage via IP backhaul.
It is designed to deliver ubiquitous wireless capacity over a range of several dense city blocks, while
giving operators a flexible network deployment option.

The Base Band Unit (BBU) is an high capacity indoor/outdoor unit, provides LTE baseband traffic,
signaling, and control signal to RRU by fiber.
The Remote Radio Unit (RRU) is an energy efficient system and designed with a robust, convection
cooled (fan less) IP65 housing for use in all outdoor environments. .

Main Features
Superior Performance
 Compatible with 3GPP Release 9 (evolved to R10)
 5MHz/10MHz/15MHz/20MHz bandwidth support
Robust Design for all Environment & Climate
 IP65 for RRU
 Fan less design
 Logical and physical redundancy
Flexible Configuration/Deployment
 Compatible with all TDD frame and special sub-frame configurations
 Cascade connection available
 Long distant supported from BBU to RRU
 Compact design and highly integrated hardware implementation

Application Scenarios
Mobile broadband for Extraodinary Date/Voice coverage
 Pulic/Private mobile broadband networks
 Urban/Sub-urban/Rural/Remote area coverage
 Emergency telecommunications service
 Public safety communications
 Enterprise/Campus networks

System Architecture

Page 219 of 232


Technical Specification
BBU (Base Band Unit)
 Smart radio resource management/scheduling
 Standard S1 interface, smooth interoperability
 High speed CPRI interface for RRU connection
 GPS/1588V2 for highly accurate clocking
 100% remote control and monitor
 Indoor fan less Design
 Optional outdoor version

Outdoor BBU Indoor BBU


Model Name ENB-35, A59-O ENB-35, A59-I
Standard LTE LTE
Supported Bandwidth 5/10/15/20MHz 5MHz/10MHz/20MHz
TRx Configuration 2T2R or 1T1R 2T2R or 1T1R
Processing Power Max. 20MHz Max. 20MHz
MIMO 2 x 2 DL SU-MIMO 2 x 2 DL SU-MIMO
400 Active User 400 Active User
User per CA Sector
1200 RRC Connected Users 1200 Connected Users
Connection Configuration Daisy Chain Daisy Chain
Supported UE Cat 3/4/6 Cat 3/4/6
Size(mm) 450 x 290 x 120 380 × 180 × 42
Weight(kg) < 10kg < 3kg
IP Rating IP65 IP30
AC 110V/220V AC 110V/220V
Power Supply
-48V -48V
Humidity 5% to 100% 5% to 100%
Operating Temperature -40°C to +55°C -10°C to +55°C
Desktop
Mounting options Wall/Pole mount
Rack Mount

Figure

RRU (Remote Radio Unit)


 Ruggedized design for extreme environment
 High speed CPRI interface for BBU connection or RRU cascading
 External antenna connectors
 IP65 enclosed

Page 220 of 232


Technical Specification
High Power RRU
Standard LTE
Model Name ENB-35, A60/61R
TRx Configuration 2T2R/2T4R(Optional)
Supported Bandwidth 5MHz/10MHz/20MHz
LTE-FDD Band 3:
Operating Frequency (UL: 1710MHz-1785MHz
DL: 1805MHz-1880MHz)
Output Power 2 x 40W
Connection Configuration Star or Daisy Chain
Emission Mask
Compliant with 3GPP TS 36 104
Spurious Emission
Size(mm) 500 x 255 x 155
Power Supply AC 110V/220V
Weight(kg) < 18kg
Humidity 5% to100%
Operating Temperature -40°C to +55°C
IP Rating IP65
Mounting options Wall/Pole mount

Figure

Page 221 of 232


Indoor CPE
AP2600-IDU, A06
 Wi-Fi 802.11 a/b/g/n/ac Standards
 2*2 MIMO and Max.32 Wi-Fi clients
 LTE Cat4, High Speed Performance

Product Description
The AP2600-IDU, A06 indoor CPE is a high-performance indoor 4G Broadband CPE, which supports the
maximum 150Mbps DL speed.

The AP2600-IDU, A06 CPE has the superior wireless access performance and comprehensive routing
capabilities, which supports 820.11 a/b/g/n/ac and advanced VoIP features.

Product Features

 Support IEEE802.11 a/b/g/n/ac


 Support IPv4/6
 Support PIN/DNS/APN
 Web-based friendly Interface
 VoIP Interface

Product Specification
Interface Specification
ETH RJ45 WAN Port * 1
ETH RJ45 LAN Port *3
Interface Summary RJ11 Voice Interface * 2
2FF Standard SIM Card * 1
Power DC Port DC 12V/1A
Antenna Internal Antenna Support External Antenna Ports * 2
Power Indication
WAN Signal Strength
LED Wi-Fi/WPS Indication LED
WAN/LAN status LED
Internet status LED
Reset/Reboot Button Power Button/WPS Button/Reset Button
Input range 100 - 240V AC (Adaptor)
Power Supply
Output:12V/1.0A DC
Wi-Fi Specification
Standard IEEE 802.11 a/b/g/n/ac
Frequency Band 2.4GHz +5.8GHz
Tx/Rx Path 2 Tx 2 Rx
Channel Bandwidth 20MHz & 40MHz
Tx Power 20dBm/Antenna
Max Access Users 20

Page 222 of 232


Outdoor CPE
AP2600-OP, A14
 TDD-LTE
 Outdoor Pole/Wall Mounting
 PoE Power Supply

Product Description
AP2600-OP, A14 is one of Comba LTE-CPE Series Product. It combines a robust IP-65 compliant
enclosure with an LTE core supported Release 9 Category 4 along with an integrated high-gain dual
polarization directional antenna. Easy implement LTE coverage extension. It can supply stable, fast, and
easy network access for you.

Product Features

 Integrated High Gain Antenna


 Support PoE Power Supply
 Support Band Locking
 IP65 Structural Design
 Web-based User Interface & TR069 Protocol for remote management

Product Specification
LTE Standard
Mode TDD-LTE
Protocol Release9 Category4 & IPv4/v6 & DHCP
Date Rate (DL:UL=3:1, 20MHz) Downlink Rate 100Mbps/Uplink Rate 10Mbps

Radio
Band38, 2570-2620MHz (TDD-LTE)
Band39, 1880-1920MHz (TDD-LTE)
Operating Frequency
Band40, 2300-2400MHz (TDD-LTE)
Band41, 2555-2655MHz (TDD-LTE)
Antenna 1T2R, 8dBi Gain , Dual-polarization (Vertical/ Horizontal)
Output Power 23dBm±2dBm

Physical
Dimensions H x W x D 260mm x 149mm x 72mm
Weight 0.7kg
Power Supply 15 V DC passive PoE
Power Consumption ≤ 7W
Operating
-40°C to +55°C
Temperature
Relative Humidity 5% to 95% (non-condensing)
Protection IP65
Interface 1 x 10/100M RJ45 port
Button 1 x Reset
3 x Signal Indicator (Low/Mid/High)
1 x Status
Indicator
1 x Power
1 x RUN

Page 223 of 232


Outdoor CPE
CP2600-OP, A10
 TDD-LTE & FDD-LTE
 Outdoor Pole/Wall Mounting
 PoE Power Supply

Product Description
CP2600-OP, A10 is one of Comba LTE-CPE Series Product. It combines a robust IP-65 compliant
enclosure with an LTE core supported Release 11 Category 6 along with an integrated high-gain dual
polarization directional antenna. Easy implement LTE coverage extension. It can supply stable, fast, and
easy network access for you.

Product Features

 Integrated High Gain Antenna


 Support PoE Power Supply
 Support Band Locking
 IP65 Structural Design
 Web-based User Interface & TR069 Protocol for remote management

Product Specification
LTE Standard
Mode TDD-LTE & FDD-LTE
Protocol Release11 Category6 & IPv4/v6 & DHCP
Date Rate (DL:UL=3:1, 20MHz) Downlink Rate 200Mbps/Uplink Rate 10Mbps

Radio
LTE-FDD Band 2:
(UL: 1850MHz-1910MHz DL: 1930MHz-1990MHz)
LTE-FDD Band 3:
(UL: 1710MHz-1785MHz DL: 1805MHz-1880MHz)
LTE-FDD Band7:
Operating Frequency
(UL: 2500MHz-2570MHz DL: 2620MHz-2690MHz)
LTE-FDD Band 28B:
(UL: 718MHz-748MHz DL: 773MHz- 803MHz)
LTE-TDD Band42:
(UL/DL: 3400MHz-3600MHz)
Antenna 1T2R, Dual-polarization (Vertical/ Horizontal)
Output Power 23dBm ± 2dBm
35MHz FDD-LTE 2CC CA
Carrier Aggregation Ability
40MHz TDD-LTE 2CC CA
Tx/Rx Path 1 Tx 2 Rx
Channel Bandwidth 5/10/15/20 MHz
Tx Power 23dBm +/- 2dBm
Rx Sensitivity -94dBm (20MHz@QPSK)

Page 224 of 232


Product Specification
Physical Specification
Total Dimension (L x W x H, approx) 260mm x 149mm x 72mm
Weight 0.7kg
Power Adapter Input 100 VAC - 240VAC, 50Hz - 60Hz Output 24V, 500mA (PoE)
CPE Power Consumption < 7W
Operating Temperature -40°C to 55°C
Operating Humidity 0% to 95%
IP Rating IP65

Software Specification
Language Settings: English, Spanish and
Language Settings: English, Spanish and Portuguese
Portuguese
Support NAT/Router mode Support NAT/Router mode
Support the http or https web server Support the http or https web server
PIN Management, SIM card Authentication PIN Management, SIM card Authentication
Support multi-APN Support multi-APN
Support VPN Support VPN
Ipv6/Ipv4 dual stack Ipv6/Ipv4 dual stack
Support preferred band and frequency Support preferred band and frequency
Support NTP Synchronization Support NTP Synchronization

Device Interface

USIM USIM card slot


LAN1/POE Use for LAN connecting and power supplying
RST Restore factory setting

Page 225 of 232


Comba EPC System
Comba EPC solution adopts flexible cloud based virtualized software structure. Taking advantage of
COTS (commercial-off-the-shelf) hardware and virtual structure.

Comba EPC system can be configured in an extremely flexible and agile way consisting all of its
sub-components (MME, S-GW, P-GW, HSS and PCRF).

Comba EPC system is a carrier-grade flexible scale LTE core network with real-time and it can be turned
to all kinds of applications. 3GPP-based standard interface enables smooth interoperability with all the
other LTE network components, including various kinds of eNodeB (Macro, Micro and Pico), UE and
billing system.

Main Features

 Compatible with 3GPP Release 10 (evolved to R13)


 Network Function Virtualization (NFV) structured system is based on X86 hardware platform, which
is flexible in hardware extension and modification so that operator’s investment and maintenance
fees are reduced.
 Interoperated supporting such as with IMS system
 Powerful carrier-grade featured in:
-Full redundancy with 1+1 control plane and N:1 data plane
-QoS network guaranteed
-Legal interception following in 3GPP TS33.107
 LTE platform ability increased by hardware stacking

Application Scenarios

 Mobile Broadband Access


 Private mobile network
 Emergency telecommunications service
 Campus and Enterprise network
 IoT applications

Comba EPC System Architecture

Page 226 of 232


Main Features & Functions
3GPP R10 defined:
NAS Signaling
Security Mechanism
User Attach & Detach
TAU & TAU List Management
Mobility Management
Session Management
Location Update
MME SAE Bearer Connection and Release
QoS Negotiation
MME, S-GW and P-GW Selection
Paging and UE Accessibility
Inter-CN Node Signaling
3GPP Interface: S1-MME, S11, S6a, S10
Intelligent features
Alarm notification
Ciphering/Integrity Protection
3GPP R10 defined:
IPv4/IPv6
Billing
Packet Routing, Forwarding and Filtering
Inter-3GPP Mobility Anchor
S-GW & P-GW Multi-PDN Function
Load Balance Management
3GPP Interface: S1-U, S5, SGi, S11
Intelligent features
Lawful Interception
Online Charging
3GPP R10 defined:
APN Profile Configuration
Mobility Management
Scalable Architecture
HSS AKA Based Authentication
Static IP Address for UE
Intelligent features
Redundancy and Backup
3GPP R10 defined:
Billing Policy Management
Dynamic Policy through AF
Flexible Policy Control
PCRF QoS Management
GBR and Non-GBR Bearers Management
Default and Dedicated Bearers Management
3GPP Interface: Gx, Rx

Page 227 of 232


Gateway
IP-Gateway Solution
The IP Gateway is a high-performance solution for aggregating control and user traffic from thousands of
GSM/LTE Cells and routing the traffic to the operator core.

Moreover, it is integrated with the function of security gateway (SeGW) that establishes encrypted IPSec
tunnels to different Cells. Furthermore, it offers high availability (99.999%) while provisioning and
maintaining a large number of Small Cells.

Key Features
IP based Architecture
 X86 Hardware
 Fully compliant with 2G/4G Standards

Flexible Configuration/Deployment
 Standard A, Gb interface to GSM Core
 Standard S1 Interface to LTE Core
 Support Ipsec tunnel to different backhaul
 Active/Standby redundancy

Cost-effective design, lower CAPEX and OPEX


 X86 IT infrastructures, low investment with high performance
 Easy installation and deployment
 100% NMS Remote control and management

System Architecture

Page 228 of 232


Function and Performance
Operating system Linux Redhat
Mobility Management
Paging Optimization
RAB Management
UE Access Control
QoS Control
Interface Supported
A over IP interface Supported for GSM
A over STM-1 Interface Supported for GSM
Gb Interface for GSM
System features
S1 Signal aggregation for LTE
GPS/1588V2 Synchronization
Security
Access Authentication
IPSec VPN
Small Cell registration & Deregistration
Redundancy
MSC Pool, SGSN Pool Access for GSM
1+1 System Backup

Page 229 of 232


Coverage Management System
CMS V8.2
Features

 Complete Management Platform forwireless enhancement


products (NE, Network Elements) including repeaters, DAS and
etc.
 Real time alarm collection with Alarm history log.
 Real-time or scheduled query for parameters configuration and
status update.
 Scheduled batch processing of commands.
 North Bound Interface (NBI) for integration with other EMS or NMS with SNMP (v2c).
 Support SMS or IP-based communication mode. Optional interface to SMS Center (SMPPv3.3 or
3.4). Support alarm forwarding to cellular device handset via SMS or email.
 Optional Electronic Map Interface (need local eMap geographical data, SHP format).
 Support Browser – Server configuration over TCP/IP
 Running on standard Server platform. Utilizing proven Microsoft SQL database to achieve scalable,
reliable and secure architecture.

Functional Block Diagram


CMS consists of web server, application server, communication server and northbound interface which
are software modules installed in one physical server hardware.
Terminal Terminal Terminal Terminal

Carrier
Central
NMS
Firewall

Application Server

Web Server Northbound Interface


( via SNMP trap)

Communication Server

Microwave RET Equipments from


Off-air Repeater DAS ComFlex 3rd venders
Equipment Antenna

Page 230 of 232


Specifications
CMS specifications may be varied depending on several factors such as hardware and software
configuration levels and performance variance, NE Qty, communication mode, data transmission link
performance, even running time and etc. Below specifications are typical values based on Comba
operational experiences. These specifications may have some variance during actual operations.

CMS Capacity
NE Qty 10000, under recommended HW & SW configuration
NE data in database One year data

Concurrent login user Qty Maximum 50, recommended 15 for a better performance

CMS Performance
Data Packet Decoding Speed 10 per second

System Response Period 2s (normal operation), 5s (mass data processing)


10000 NEs per hour, under SMSC communication mode
Polling Speed
30000 NEs per hour, under PSD communication mode

Communication mode between CMS and monitored NEs

 SMS. With SMS mode, devices must be equipped with inside modems to send/receive SMS to/from
CMS; and CMS also must be equipped with a modem or directly connecting with SMS
Center/gateway to send/receive SMS to/from devices.
 Packet Switched Data (PSD), such as GPRS, CDMA 1x, HSDPA, etc. With PSD mode, devices
must be equipped with inside modems, and inserted with a PSD enabled SIM/UIM/USIM.
 Ethernet. With this mode, devices must be equipped with inside Network Interface Card (NIC).
 Circuit Switched Data (CSD) isn’t supported.

North-Bound Interface
Currently CMS supports below NBI to transfer CMS information to other EMS/NMS.
 SNMP Trap, Email, SMS for alarm forwarding.
 Timely Performance/Inventory file for performance/inventory management.

System Requirements
CMS Server Recommended Hardware Requirements
Processor Processor
Memory Memory

Hard disk Hard disk


Network Network

Serial Ports Serial Ports

CMS Server Software Requirements


Operating System Operating System

Supported Database Applications Supported Database Applications

CMS Installation Requirements


For the installation of CMS, the CMS server should be open forFor the installation of CMS, the CMS server should be
remote access. open for remote access.

Page 231 of 232


CMS GUI

Page 232 of 232


China Headquarters
Comba Telecom Systems China Ltd
Add: No.10 Shenzhou Road,
Guangzhou Science City, China
Tel: +8620 2839 0000
Fax: +8620 2839 0136

Corporate & APAC Headquarters


Comba Telecom Systems Holdings Ltd
Add: 611 East Wing, No.8 Science Park West Avenue,
Hong Kong Science Park, Hong Kong
Tel: +852 2636 6861
Fax: +852 2637 0966/+852 2116 6055

Middle East Headquarters


Comba Telecom Limited
Add: Unit 112, Building 5, Gold and Diamond Park,
Al Qouz, Dubai, UAE
Tel: +971 0 4 346 7277
Fax: +971 0 4 346 7288

Europe Headquarters
Comba Telecom Systems AB
Add: Gustavslundsvagen 147,
SE-167 51 Bromma, Stockholm, Sweden
Tel: +46 8 253 870
Fax: +46 8 253 871

Caribbean and Latin America Headquarters


Comba Telecom Ltda
Add: Av. Doutor Chucri Zaidan nº 29 – 29º andar Conj.
2910/2911, Vila Cordeiro, Edificio Capital Corporate,
04583-110, Sao Paulo, Brazil
Tel: +55 11 3509 4800
Fax: +55 11 3509 4833

North America Headquarters


Comba Telecom Inc.
Add: 235 Charcot Ave, San Jose, CA 95131, USA
Tel: +1 408 526 0180
Fax: +1 408 526 0181

India Office (Operations Office)


Comba Telecom India P Ltd
Add: G-4 Sector 63, Noida – 201301 U.P, India
Tel: +91 120-4599000
Fax: +91 120-4599001

business card
For more local offices information,
Please visit our website
www.comba-telecom.com

You might also like