BDO NGIPS Project

INSTALLATION GUIDE TO INTEGRATE FMC TO SPLUNK


VER 1.0
Contents
BDO NGIPS Project......................................................................................................................................1
INSTALLATION GUIDE TO INTEGRATE FMC TO SPLUNK...............................................................................1
INTEGRATION OF FMC TO SPLUNK..............................................................................................................3
INSTALLATION GUIDE..................................................................................................................................4
STEP-BY-STEP PROCEDURE..........................................................................................................................5
Back Out Procedure.....................................................................................................................................7
INTEGRATION OF FMC TO SPLUNK

No. Activity Date Time Duration Remarks

1. Integration of FMC to Splunk 1 day

2
3
REFERENCE NO:
INSTALLATION GUIDE (BR/CRF/IR No.)

SYSTEM NAME VERSION/RELEASE

ENVIRONMENT
FMC & SPLUNK
☐ ☒

UAT PROD

REQUIREMENTS FOR INSTALLATION

HARDWARE
[1] – FIREPOWER MANAGEMENT CENTER

SOFTWARE
FMC – 6.2.3 patch 6
SPLUNK
STEP-BY-STEP PROCEDURE
1. Login to the FMC web GUI

2. Navigate System > Integration > eStreamer


Check out what type of events you want to log and save.
3. Click Create Client
Provide the ip address of your Splunk server and password.
Then click save.
Back Out Procedure
1. Uncheck eStreamer event configuration

2. Remove created client