Professional Documents
Culture Documents
1
10/05/2019
USB
Communications
Joystick Navigation
2
10/05/2019
Panel Sealing
Gasket 10-30VDC Power 640x480 Digital
Input Camera
LED Flash
Panel front
Mounting chassis
permanently installed into
panel with power and
RJ45 Ethernet connection
3
10/05/2019
132.9mm 40.1mm
39⁰
63⁰
4
10/05/2019
1 Safety
2 Efficiency
3 Accuracy
9
1 Safety
IR Windows MN4000
With “traditional” IR Windows, risk of severe The infrared inspector can be in a different
injury or even death still exisits. room, inspecting hundreds of panels remotely
without any exposure to live equipment or the
No IR Window can protect a thermographer need to even enter a switchroom.
from an Arc-flash explosion.
No exposure for your infrared professional,
IR Windows are no longer the means no danger which in turn means no
safest solution. chance of injury and associated litigation.
10
5
10/05/2019
2 Efficiency
IR Windows
IR Windows are an old solution to an even
MN4000
older problem; Infrared cameras cannot see
through electrical panels that cannot be
opened when live for safety reasons MN4000 is generations ahead of traditional IR
Windows. MN4000 can be configured by your
IR Windows solve this problem by creating infrared professional to notify authorised
one or more “access points” per piece of personnel automatically when a temperature
equipment that are transparent to IR. exceeds a preconfigured setpoint.
BUT with facilities installing hundreds, if not Supplied with dedicated setup, alarm and
thousands of IR Windows, the task of trending software, web interfaces and even
inspecting these points for your infrared pre-written Programmable Logic Controller
professional becomes more than can be (PLC) code blocks, MN4000 enables your
achieved. infrared professional to do what they are best
at, interpret results, without ever leaving the
Many times, IR Windows are installed but not office.
actually used not only because of the time
taken to inspect them all but the wasted time Write-predetermined, automated control
travelling between IR Window installations. actions based upon temperature rise, fall,
averages or deltas
IR Windows are not an efficient
solution.
11
3 Accuracy
IR Windows
IR Windows optics, regardless of material, act
MN4000
as a semi-transparent filter. Yes, the IR
Camera can “see through” an IR Window but
when it comes to measuring the hot-spot, the MN4000 is not an IR Window, it is a
IR Window filtering creates an error meaning calibrated, panel mounted thermal imaging
your camera measurement is inaccurate. camera.
Some IR Windows and IR Cameras are MN4000 measures temperature across 4800
paired so that they can correct for this error, points within its field of view, with an accuracy
but not all. of ±2⁰/2%.
Mesh type IR Windows create errors that No, corrections are needed. No “Longwave
cannot be reliably and repeatedly corrected and Shortwave” transmission values, no
for across the temperature range. parameters to alter in your camera. MN4000
does it all, automatically, with maximum
The bottom line with IR Windows is that accuracy and repeatability.
unless the camera and IR Windows are
matched together, the IR Window is a
qualitative solution to a problem which
requires quantitative results.
12
6
10/05/2019
13
70mm
(2¾”)
300g/10oz
14
7
10/05/2019
Simple Connections
15
Easy Installation
16
8
10/05/2019
PC App
17
Measurement &
Control functions
Webserver
Grid alarm
notification
18
9
10/05/2019
PLC
19
• THE STATIC IP ADDRESS IS SET IN THE DEVICE AND DOES NOT CHANGE EVEN WHEN POWERED
DOWN AND UP. MN4000 MN4100 CAN HOWEVER BE SET TO STATIC OR AUTO IP ADDRESS. IN THIS
CASE THEY TALK TO A DHCP SERVER WHICH ALLOCATES AN IP ADDRESS FOR IT AND THEN PUTS
IT ON THE NETWORK AND THEN THE CAMERA IS AVAILABLE ON THE NETWORK TO BE TALKED TO
AND DATA ACESSED BY OTHER DEVICES ON THE NETWORK WHICH REQUIRE IT.
20
10
10/05/2019
21
640
Visual Image
480
1. Visual image accessible via
htp commands
80
Infrared Image
1. 4800 Measurement Points,
all accessible via
60
MODBUS/TCP
2. Control & Alarm accessible
via MODBUS/TCP
Measurement Range -10 to 120C / (14 to 302F)
22
11
10/05/2019
Safe
Efficient
Compact
Accurate
Questions?
23
12