You are on page 1of 1

Rankine Cycle Analysis - Reheat and 2 feedwater heaters

Efficiencies: Pump: 0.8 TTD (F) = 8.0


Turbines
HP: 0.88
LP: 0.9

State Temp. Pressure Entropy Enthalpy Comment


F psia Btu/lb-R Btu/lb

1 1000 2000 1.5603 1474.1 given


2s 575 456 1.5603 1289.0
2 456 1.5860 1316.0
3s 200 1.5603 1210.0
3 200 1.5960 1241.7
4 1000 200 1.8400 1527.0
5s 49 1.8400 1333.0
5 49 1.8710 1368.0
6s 1 1.8400 1027.0
6 1 1.9300 1077.0 M=2.7%
7 101.74 1 0.1326 69.7 v=.016136 cu.ft./lbm
8s 2000 0.1326 75.7
8 2000 77.2
9 281 49 0.4090 248.7 sat. liq.
10 1 248.7
11 273 2000 242.0
12 457.5 456 0.6380 439.0 sat. liq.
13 49 439.0
14 449.5 2000 429.7

m1 = (h14-h11)/(h2-h12) = 0.2140251 1-m1 = 0.7859749

m2={m1(h9-h13)+h11-h8}/(h5-h9)= 0.1108534 1-m1-m2 = 0.6751215

Wt = h1-h2 + (1-m1)(h2-h3) + (1-m1)(h4-h5) + (1-m1-m2)(h5-h6) =


537.9 Btu/lb

Wp = h7-h8 = -7.5 Btu/lb

Wn = Wt + Wp = 530.5 Btu/lb

Qa = h1-h14 + (1-m1)(h4-h3) = 1268.6 Btu/lb

Thermal efficiency = 0.418

Heat Rate = 8162.3 Btu/kW-hr

Work ratio = Wt/Wp = 72.1