You are on page 1of 8

1 200

Upgradable Fully Featured Power & Energy Meter


ith
ade w
e v e n ue Gr /O &
R ced I
Advan Quality
e r
Pow

Shark 200 Transducer Only


®

Shark 200
®

Meter/Transducer

From Simple to Sophisticated Industry Leading Performance


• V-Switch™ Technology Upgrade • Highly Accurate Metering Technology
www.electroind.com

• Simple Multifunction Meter: V-Switch™ Key 1 • Power Quality Recording up to 512 Samples/Cycle
• Historical Data Logging: V-Switch™ Key 2 • Embedded Web Server - with Smartphone and Tablet
Support
• Additional Memory for Extensive Data Logging:
V-Switch™ Keys 5 and 6 • Dual Ethernet Ports Compatible with Modbus,
DNP3 over TCP/IP, and IEC 61850 Protocols!
• Advanced Power Quality Waveform Recorder:
V-Switch™ Keys 5 and 6 • Supports Email on Alarm and Periodic Email
Notification of Meter Status and Readings
• Ethernet Port Offers Data Push to Cloud Servers
• Enhanced Security with IP Whitelisting
High Performance Waveform Advanced Features Summary

Recording
• High Performance Waveform Recorder

Basic Features Summary • Up to 4 Megabytes Flash for Historical Data Logging and PQ
Recording

• 0.2% Class Revenue Certifiable Energy and Demand Metering • Extremely Configurable Field Upgradable I/O
• 100BaseT Ethernet –­ Rapid Response™ Technology
• Meets ANSI C12.20 0.2 CL and IEC 62053-22 0.2S Accuracy
Standard • V-Switch™ Technology
• High Precision Frequency Measurement for Frequency Control
• Multifunction Measurement

• 3 Line .56" LED display and % of Load Bar for Analog Perception Applications

• 0.007 Hz Frequency Measurement for Generating Stations


• Utility Metering • Submetering*
• Standard RS485 (Modbus and DNP3)
• Commercial Metering • Analog Meter Replacement
• IrDA Port Enables Laptop PC Reading and Programming • Substations • Power Quality Studies

• Ultra Compact • Industrial Metering • Disturbance Recording


• Power Generation • Load Studies
• Fits both ANSI and DIN Cutouts
• Campus Metering • Voltage Recording
* New York State approved for residential submetering.

Accuracy and Upgrade Switches

Electro Industries introduces a new standard in panel mounted power Accuracy


metering. The Shark® 200 metering system is an ultra compact power
metering device providing industry leading revenue metering Measured Parameters Accuracy % Display Range
functionality combined with advanced data logging, power quality,
Voltage L-N 0.1% 0-9999 Scalable V or kV
communication, and I/O traditionally found only in high performance and
Voltage L-L 0.2% 0-9999 V or kV Scalable
high cost systems. This product is designed to incorporate advanced
Current 0.2% 0-9999 Amps or kAmps
features in a cost effective, small package, for large scale, low cost
+/- Watts 0.2% 0-9999 Watts, kWatts, MWatts
deployment within an electrical distribution system.
+/-Wh 0.2% 5 to 8 Digits Programmable
+/-VARs 0.2% 0-9999 VARs, kVARs, MVARs

V-Switch™ Technology +/-VARh 0.2% 5 to 8 Digits Programmable


VA 0.2% 0-9999 VA, kVA, MVA
VAh 0.2% 5 to 8 Digits Programmable
The Shark® 200 meter is equipped with EIG’s exclusive V-Switch™
PF 0.2% +/- 0.5 to 1.0
technology. This technology allows users to upgrade and add features to
Frequency +/- 0.007 Hz (45 to 65) Hz
the meter without removing it from installation.
THD +/- 2.0% 1 to 99.99%
% Load Bar +/- 1 Segment (0.005 to 6) A
Features V1 V2 V3 V4 V5 V6 Note: Applies to 3 element WYE and 2 element Delta connections. See full accuracy
Multifunction Measurement with I/O Expansion P P P P P P specifications in Shark® 200 Meter User Manual. Neutral current 2% accuracy.

2 MB Data Logging P P P
3 MB Data Logging P Advanced Revenue Energy Metering Capabilites
4 MB Data Logging P P P P
Harmonic Analysis P P P P
• Line Frequency Time Sync • Historical Load Profiling
TLC and CT/PT Compensation P P P P P P
Limit and Control Functions P P P
• Traceable Watt-hour Test • Transformer and Line Loss
64 Samples per Cycle Waveform Recorder P
Pulse Compensation
512 Samples per Cycle Waveform Recorder P • Utility Block and Rolling • CT/PT Compensation
Average Demand
2
Extensive Data Logging Capability System Events Log

(V2 and Higher)


To protect critical billing information, the meter records and logs the fol-
lowing with a time stamp:
At V2, the Shark® 200 meter has 2 Megabytes of data logging to be used
for historical trends, limit alarms, I/O changes, and sequence of events
(V5 and V6 offer even more memory). The unit has a real-time clock that • Demand Resets • Log Reads
allows for time stamping of all the data in the instrument when log events • Password Requests • Programmable Settings
are created. • System Startup Changes
• Energy Resets • Critical Data Repairs
• Log Resets
Historical Logs
Limit/Alarm Log
• 3 Assignable Historical Logs
• Independently Programmed • Provides Magnitude and Duration of an Event
Trending Profiles • Includes Time Stamps and Alarm Value
• Up to 64 Parameters per Log • 2048 Events Available
Historical Trending

I/O Change Log Limit Alarms and Control Capability (V4 and Higher)

• Provides a Time Stamped Log of Any Relay Output • Any Measured Parameter • Based on % of Full Scale
• Provides a Time Stamped Log of Input Status Changes • Up to 16 Limits Settings
• 2048 Events Available • Voltage/Current Imbalance

High Performance Power Quality Analysis (V5 and V6)

Simultaneous Voltage and Current Waveform Waveform Scope


Recorder

The unit uniquely offers a waveform scope


The unit records up to 512 samples per cycle for a voltage sag or swell or to view the real time waveform for voltage
a current fault event. The unit provides the pre and post-event recording and current. The waveform scope allows
capability shown in the table below. Waveform records are programmable the meter to be used as a basic oscillo-
to the desired sampling rate. V5 provides up to 3 Megabytes of storage scope throughout a power system.
and V6 provides a total of 4 Megabytes.
Independent CBEMA (or SEMI F47) Log Plotting
The meter's advanced DSP design allows Power Quality triggers to be
based on a 1 cycle updated RMS. Up to 170 events can be stored until the The meter stores an independent CBEMA or SEMI F47 log for magnitude
memory fills. The meter stores waveform data in a first-in/first-out circular and duration of voltage events. This allows a user to quickly view total
buffer to insure data is always recording. surges, total sags and duration, without retrieving waveform data. The
meter also fully supports MV90. Time stamps are stored with millisecond
Optional Waveform Recorder accuracy.

Samples Pre Post Max Max Harmonic Recording to the 40th Order
per Event Event Waveform Waveform
Cycle Cycles Cycles per Event per Event

16 32 96 256 85
The Shark® 200 meter provides
V5 32 16 48 128 85
advanced harmonic analysis to the
64 8 24 64 85 40th order for each voltage and current
128 4 12 32 170 channel, in real time. Using the stored
V6 256 2 6 16 170 waveforms, harmonic analysis is
512 1 3 8 170 available to the 255th order.
Note: Sampling rate based on 60 Hz systems. For 50 Hz systems, multiply by 1.2.

3
Standard Communication
Capability

The Shark® 200 meter provides two independent communication ports • KYZ Pulse - In addition to the RS485 port, the meter also
with advanced features. includes Pulse Outputs mapped to absolute energy.

Rear Mounted Serial Port with KYZ Pulse Front Mounted IrDA Communication

• RS485 - This port allows RS485 communication using Mod- Uniquely, the Shark® 200 meter also has an optical IrDA port, allowing
bus or DNP3 protocols. Baud rates are from 1200 to 57600. you to program it with an IrDA-enabled laptop.

Field Communication Capability

The Shark® 200 meter offers unequaled I/O PO1S: Four Pulse Outputs / Four Status Inputs
expandability. Using the two universal option slots, the unit can be
• Programmable to any energy parameter and pulse
easily configured to accept new I/O cards, even after installation. The unit
value.
auto-detects installed I/O option cards. Up to 2 cards of any type can be
used per meter. • Form A: Normally open contacts.
• Also used for End of Interval pulse.
INP100S: 100BaseT Ethernet Capability

• NTP time server for high accuracy network time RO1S: Two Relay Outputs / Two Status Inputs*
synchronization.
• 250 V AC / 30 V DC - 0.25 A relays, form C.
• 12 simultaneous Modbus TCP/IP connections; 5
• Trigger on user set alarms.
simultaneous DNP over TCP/IP connections.
• Set delays and reset delays.
• Supports data push to Cloud servers.

FOVPS or FOSTS: Fiber Optic Card


INP300S: IEC 61850 Protocol Ethernet Card
• EIG’s exclusive Fiber Optic Daisy Chain switchable
• Simultaneous communication of IEC 61850 and
built-in logic mimics RS485 half duplex bus, so
Modbus TCP/IP.
you can daisy chain meters for lower installation
• 5 simultaneous MMS clients. costs. Full duplex is also assignable.
• Multiple logical nodes; configurable .CID file. • ST Terminated Option (-FOSTS).
• Versatile Link Terminated Option (-FOVPS).
1mAOS: Four Channel Bi-directional 0-1
• Modbus and Level 2 DNP3 protocols available.
mA Outputs

• Assignable to any parameter.


Meter Auto Detects
• 0.1% of full scale. I/O Card Type

• Max. Load Impedance 10 kΩ.


Simple Field
20mAOS: Four Channel 4-20 mA Outputs Upgrade

• Assignable to any parameter.


• 0.1% of full scale.
• 850 Ω at 24 V DC. Field-Expandable I/O Slots

• Loop powered using up to 24 V DC.


Note: I/O cards can be ordered separately - see last page.
*The meter must be at V-Switch™key 4 or higher to use the relay features.
4
100BaseT Ethernet (INP100S or INP300S)

Simultaneous Data Connections

(HTTP) (Level 2 DNP3 over TCP/IP) (Modbus TCP/IP)


HTTP Web Server SCADA Meter Reading Software

(INP100S)

Level 2 DNP3 over TCP/IP


INP300S

HTTP
Modbus TCP/IP or IEC 61850 Protocol
Simultaneous Connections
to Multiple Software Systems

INP100S - Web Server, Modbus, DNP, and Email • Dual Ethernet Port Capable
• Simultaneous Modbus, DNP over Ethernet, and IEC 61850
• Web Server with Configurable HMI
• Smartphone Compatible Both INP100S and INP300S offer enhanced security through the Exclusive
• 12 Connections Modbus TCP/IP Client feature, which provides secure communication for a Whitelisted IP/
MAC address, to protect from unauthorized programming.
• 5 Connections DNP over TCP/IP
• Data Push of Meter Readings to Cloud Servers
• Send Email on Alarm or Periodic Email Notification of Meter
Status and Readings
4.85” 4.65" 4.76"
[12.32cm] [11.81cm] 12.10cm
4.10" 4.14” 0.62”
INP300S - Web Server, Modbus, DNP, and IEC 61850 [10.41cm] 10.52cm 1.61cm

• IEC 61850 Protocol


[12.75cm] HI HI HI
[12.32cm]

9.04cm
5.02”

3.56”
4.85”

Ic Ib Ia

• 5 Modbus Connections LO LO LO

• 5 MMS Clients
Embedded Web Server with Smartphone Support
• Web Server for Status and Configuration 3.25” 0.91" 3.25”
[8.26cm] 2.31cm 8.26cm

Shark 200 Meter ANSI and DIN Mounting 3.56”


®

[9.04cm] ANSI Mounting DIN Mounting


3.38" Sq. 9.20cm

4 X 0.2”
The unit mounts directly in an ANSI C39.1 (4” round form) or an IEC 92
mm DIN square form. This is perfect for new installations and for existing 4.0”

panels. In new installations, simply use DIN or ANSI punches. For existing
[9.04cm]

9.20cm
3.56”

panels, pull out old analog meters and replace them with the Shark® 200
meter. The meter uses standard voltage and current inputs so that CT and
PT wiring does not need to be replaced. American European
(One meter fits both standards)

Shark 200T Transducer


®

This transducer version of the Shark® 200 meter does not include a
display. The unit mounts directly to a DIN rail and provides an RS485 Easy DIN Rail
Mounting
Modbus or Level 2 DNP3 output and the expandable I/O.

5
Typical Substation Solutions

Substation Voltage and Frequency Recording

Traditionally, voltage recording meters were relegated to high cost


metering or monitoring solutions. The Shark® 200 meter can be placed
throughout an electrical distribution network. The meter provides one of
the industry's lowest cost methods of collecting voltage information within
a Utility power distribution grid.

• Perform voltage reliability analysis to ensure proper voltage


to customers.
• Compare voltage reliability throughout transmission or distribu-
tion networks.
• Monitor the output of substation transformers or line regulators.
• Initiate conservation voltage reduction, reducing system demand.
• Monitor highly accurate frequency to regulate frequency stability.
• Replace costly frequency transducers.

Interval Load Profiling

The Shark® 200 meter allows you to log substation data over time with
regard to electrical usage, demand, voltage, current, PF, and many other
parameters. This enables a complete analysis of the power system over
time.

• Provide revenue accurate load profiling.


• Determine substation usage.
• Analyze feeder capacity and utilization.
• Provide time based load profile for planning and estimation.
• D
 ata trend PF distribution and imbalances for system efficiency
analysis.

Low Cost Substation Telemetry

The Shark® 200 meter's advanced output capability brings back data
using many different communication media, such as RS485, Ethernet, and
analog outputs. This ensures that one meter can be used for almost every
substation application, no matter what communication infrastructure is
needed.

• Perfect for new or retrofit applications.


• Multiple communication paths.
• One meter provides outputs for every application.
• Multiple systems and/or users can access data simultaneously.

6
Dimensional Drawings

4.85” 4.71” 4.76"


[12.32cm] [12.00cm] [12.10cm]
4.10” 4.14” 0.62”
[10.41cm] [10.57cm] [1.61cm]

[12.75cm]

[9.04cm]
[12.32cm]
HI HI HI

5.02”

3.56”
4.85”
Ic Ib Ia

LO LO LO

3.25” 0.91" 3.25”


[8.26cm] [2.31cm] [8.26cm]

Shark® 200 Meter Shark® 200 Meter Shark® 200T


Front Dimensions Side Dimensions Side Dimensions

Wiring Diagrams

LINE LINE

N A B C A B C

3 Phase 4 Wire 3 Phase 3 Wire


WYE Direct Delta Direct
CT
Shorting
Block

Power Earth Ground Power


CT Supply
Supply
Shorting Connection
Connection
Block GND GND
Earth Ground FUSE FUSE
L(+) L(+)
HI HI HI L(+) HI HI HI L(+)
N(-) 3A N(-) 3A
N(-) N(-)
lc lb la lc lb la Vref
Vref
Va LO LO LO Va
LO LO LO
Vb Vb
Vc Vc

FUSES FUSES
3 x 0.1A 3 x 0.1A

N A B C A B C
LOAD LOAD

LINE LINE

N A B C A B C

3 Phase 4 Wire 3 Phase 3 Wire


WYE with PTs Delta with PTs
CT
Shorting
Block

Power Earth Ground Power


CT
Supply Supply
Shorting
Connection Connection
Block GND GND
Earth Ground FUSE
L(+) L(+) FUSE
HI HI HI L(+) HI HI HI L(+)
N(-) 3A N(-) 3A
N(-) N(-)
lc lb la Vref lc lb la Vref
LO LO LO Va Va
LO LO LO
Vb Vb
Vc Vc

FUSES FUSES
3 x 0.1A 2 x 0.1A

Earth Ground
Earth Ground
N A B C A B C
LOAD LOAD

7
Specifications
Voltage Inputs: Isolation: Standard Meter Accuracy:
Communication Format:
• (20-576) Volts Line To Neutral, • All Inputs and Outputs are Galvani- • See Page 2
(0-721) Volts Line to Line cally Isolated to 2500 Volts • 2 Com Ports (Back and Faceplate)
• Note: For 2.5 element programmed units, de-
• Universal Voltage Input Environmental Rating: • RS485 Port through Backplate
grade accuracy by an additional 0.5% of reading.
• Input Withstand Capability – Meets IEEE • Storage: (-20 to +70) °C • IrDA through Faceplate
C37.90.1 (Surge Withstand Capability) • Note: For 1A (Class 2) Nominal, degrade
• Operating: (-20 to +70) °C • Com Port Baud Rate: (1200 - 57600)
• Programmable Voltage Range to Any PT ratio accuracy to 0.5% of reading for watts and
• Humidity: to 95% RH Non-Condensing • Com Port Address: 1-247 energy; all other values 2 times rated accuracy.
• Supports: 3 Element WYE, 2.5 Element WYE, • Faceplate Rating: NEMA 12 • 8 Bit, Parity Setting: Odd, Even, None
2 Element Delta, 4 Wire Delta Systems Compliance:
• Mounting Gasket Included • Modbus RTU, ASCII, or DNP3 Protocols
• Input Impedance 1 Mega Ohm/Phase; Burden: • IEC 62053-22 0.2S
0.36 VA/Phase at 600 V; 0.014 VA at 120 Volts • Protection: IP 30 - Meter Front/Back, Optional KYZ Pulse:
DIN Rail Mounting, Optional Plug-in I/O Modules • ANSI C12.20 0.2 CA
• Input Wire Gauge: AWG#12 -26/ • Type Form C Contact
(0.129 -3.31) mm2 Sensing Method:
• On Resistance: 35 Ohms Max • ANSI (IEEE) C37.90.1 Surge Withstand
Current Inputs: • True RMS
• Peak Voltage: 350 V DC • ANSI C62.41 (Burst)
• Class 10: (0.005 to 11) A, 5 A Nominal • Sampling at over 400 Samples/Cycle on all
Channels of Measured Readings Simultaneously • Continuous Load Current: 120 mA • EN61000-6-2 – Immunity for
• Class 2: (0.001 to 2) A, 1 A Nominal Secondary
• Harmonics Resolution to 40th Order • Peak Load Current: 350 mA (10 ms) Industrial Environments: 2005
• F ault Current Withstand (at 23 °C):
• Waveform up to 512 Samples/Cycle • Off State Leakage Current @350 V DC: 1uA • EN61000-6-4 – Emission Standards
100 A for 10 Seconds, 300 A for 3
Seconds, 500 A for 1 Second Update Rate: Dimensions and Shipping: for Industrial Environments: 2007

• Continuous Current Withstand: 20 A for Screw • Watts, VARs, and VA - Every 6 Cycles • Weight: 2 lbs /.91 kg • EN61326-1 - EMC Requirements: 2006
Terminated or Pass Through Connections
• All Other Parameters - Every 60 Cycles • Basic Unit: H4.85" x W4.85" x L4.25" • KEMA Certified for IEC 61850
• Programmable Current to Any CT Ratio
Power Supply: • Shark® 200 Meter Mounts in 92 mm
• Burden 0.005 VA per Phase Max at 11 A • Certified to UL/IEC 61010-1 and CSAC22.2
DIN & ANSI C39.1 4" Round Cutouts
• Option D2: (90 to 265) Volts AC and (100 No. 61010-1, UL File: E250818
• Pickup Current: 0.1% of Nominal to 370) Volts DC Universal AC/DC Supply •  hark® 200T Transducer: DIN Rail
S
Class 10: 5 mA: Class 2: 1 mA Mounted Using Attached DIN Rail Clip • REACH/RoHS Compliance
• Option D: (18-60) Volts DC (24
• Pass Through Wire Diameter: 0.177” / 4.5 mm to 48 VDC Systems) • Shipping Container Dimensions: 6” Cube • New York State approved for
• Burden: 10 VA Max residential metering

Ordering Information - All fields must be filled in to create a valid part number.
Model Frequency Current V-Switch™ Power I/O Slot 1* I/O Slot 2* Mounting
Range Input Pack Supply (Shark® 200 Meter)

Option - - - - - - -
Numbers:
Example: Shark200 - 60 - 10 - V2 - D2 - INP100S - X - X

Shark200 60 10 V1 D2 X X X
(Meter/Transducer) 60 Hz System 10 A Multifunction Meter Only (90-265) V AC/ None None ANSI Mounting
Secondary DC

Shark200T 50 2 V2 D RO1S** RO1S** DIN


(Transducer Only) 50 Hz System 2A Standard Data Logging (18-60) V DC 2 Relays/2 Status 2 Relays/2 Status DIN Mounting Brackets
Secondary Memory

V3 PO1S PO1S
Power Quality Harmonic 4 Pulses/4 Status 4 Pulses/4 Status
Accessories V4 1mAOS 1mAOS
Limits & Control 4 Channel Analog 4 Channel Analog
Communication Converters Output 0-1 mA Output 0-1 mA
(bidirectional) (bidirectional)
9PINC RS485 to USB Adapter
V5 20mAOS 20mAOS
CAB6490 USB to IrDA Adapter 64 Samples/Cycle 4 Channel Analog 4 Channel Analog
Unicom 2500 RS485 to RS232 Converter Waveform Recording Output 4-20 mA Output 4-20 mA

Unicom 2500-F RS485 to RS232 to Fiber Optic Converter V6 FOSTS FOSTS


512 Samples/Cycle Fiber Optic Output Fiber Optic Output
Waveform Recording ST terminated ST terminated

Compliance Documents FOVPS FOVPS


Fiber Optic Output Fiber Optic Output
Current Transformer Kits VPIN terminated VPIN terminated
Certificate of This provides Certificate of Calibration with
Calibration, NIST traceable Test Data. CT200K 200/5 Ratio, 1.00" Window, 3 CTs INP100S INP100S
Part#: CCal 100BaseT Ethernet 100BaseT Ethernet
CT400K 400/5 Ratio, 1.25" Window, 3 CTs
Software INP300S INP300S
CT800K 800/5 Ratio, 2.06" Window, 3 CTs
IEC 61850 Protocol IEC 61850 Protocol
COMPQA5P1Y Communicator PQA 5.0 Software for Ethernet Ethernet
CT2000K 2000/5 Ratio, 3.00" Window,
Windows Single-Computer License (One Year)
3 CTs
* I/O cards can be ordered separately using the part
CT Specifications numbers shown in the ordering information.
Frequency (50 to 400) Hz; Insulation: 600 Volts, 10 kV BIL ** The meter must be at V-Switch™ key 4 or
higher to use the relay features.
Flexible Leads UL 1015, 105 °C, CSA Approved, 24" Long, AWG#16
* Consult factory application engineer for additional transformer ratios, types, or window sizes.
Shark® 200
1800 Shames Drive, Westbury, NY 11590 1-877-EIMETER web page:
(1-877-346-3837) Tel: 516-334-0870 Fax: 516-338-4741
Email: sales@electroind.com www.electroind.com E149702 092120 V.1.31