You are on page 1of 4
sn Specification Sheet A. Programmable Logic Controller (PLC) Automation system Quantity 03 Sets Each PLC Automation system consists of the following items: 1. Central processing Unit a. System characteristics: Should be programmed with STEP 7 or higher, Automatic routing via PROFINET / Profibus, independent of network Data block routing via PROFINET / Profibus Integrated Web server functionality Integrated communication services (TCP/IP, UDP, ISO on TCP, SNMP, NTP, PROFINET CBA/IO) Isochronous operation on the bus system b. Integrated work memory: 384 Kbyte ¢. Integrated load memory: 8 MByte d. No. of timers: 256 e. No. of counters: 256 £. No. of bit memories: 2048 Byte g. Processing times For bit-operations, min.: 0,05 ps For word operations: 0,09 us For arithmetic operations: 0,12 ps For floating point arithmetic: 0.45 ps h. Interfaces MPI (RS485), PROFIBUS (RS485), PROFINET (RJ 45-Ethernet), Integrated PROFINET Switch i. Integrated fuctions Real-time clock, Buffer time 6 weeks, Password protection |. Supply voltage Rated value: 2av DC la. Accessories i, Micro memory card 2MB ii, 19 inch DIN Rail channel Note: The above CPU module should be functionally equivalent to $7 315 2PN/DP and should be programmed by Step 7 Total Integration Automation portal VII 2, Digital Input Module Qty.: 04 Numbers |_| Supply voltage 24. V DC Yes permissible range, lower limit (DC) 204 V permissible range, upper limit (DC) 28.8 V 2 | Number of digital inputs 16 3 | Input voltage Rated value, DC 24v for signal "0" 301045 V for signal "1" 13t030V 4 [Input delay for standard inputs Programmable 0.17,5/3/15/20 ms 5 | Status display Green LED per channel Sensor supplies Green LED per group 3 | Galvanic isolation between channels Groups of 16 4 | Opto isolation between channels and backplane Opto isolation 5 | Permissible potential difference between different | 75 VDC/ 60 VAC circuits 6 | Isolation 500 VDC 7 | Features Tsochronous mode, programmable diagnostics, programmable diagnostics interrupt, programmable hardware interrupts, 2 short circuit proof sensor supplies for each group of 8 channels, support for external redundant sensor suppl: 8 | Connection method 40-pin front connector 2a. Accessories: Front connectors 3. Relay Output Module Qty.: 04 Numbers 1 | Supply voltage 24 V DC Yes permissible range, lower limit (DC) 204 V permissible range, upper limit (DC) 28.8 V 2 | Relay outputs Number of Relay outputs 8 with electrical isolation in groups of I channel 3_| Maximum potential difference between outputs 500 VAC 4 | Isolation test voltage difference between outputs 2000 VAC 3] Status display Green LED per channel 6 | Switching capacity with resistive load 24VDC @ 2A | 0.7 million Inductive load 24VDC @ 2 A | 0.3 million 7 | Switching frequency Mechanical 10 Hz With resistive load 2He 8 [Connection method 40-pin front connector 3a, Accessories: Front connectors 4, Analog input module Qty.: 02 Numbers 1. | Supply voltage Load voltage 24 VDC Reverse polarity protection Yes 2._| Number of analog inputs 8 Permissible input voltage for voltage input 75 V; 35 V continuous, 75 V for max. 1s Permissible input current for current input 40 mA (@estruction limit), max. 3._| Measurement principle integrating Resolution with overrange (bit including sign), 16 bits Integrating time (Parametrizable) Yes: 23/ 72/ 83/ 95 ms Basic conversion time, ms 10 ms (4-channel mode); 95/83/72/23 ms (8-channel mode) Interference voltage suppression for interference frequency fin Hz 50 Hz Input Range Voltage Range 40-10 V, +/-SV with input resistance >= 10 Mohms Current Range 0 to 20 mA , 4 to 20 mA with input resistance <= 250 ohms 3. | Interrupts Limit value monitoring Programmable for 8 channels Programmable Hardware interrupt when limit exceeded Hardware interrupt at end of cycle 5. | Errors (Operational limit in overall temperature range) Voltage, relative to input area Current, relative to input area H- 0.1% #101 % 6. | Diagnostics Diagnostic alarm, Limit value alarm parametrizable for all channels 7. | Galvanic Isolation Galvanic isolation between channels in groups of 2, between channels and backplane. Isolation voltage 500 VAC 5. DC Power Supply Qt nove NOTE: Accessories: Front connectors AC Input: I-phase 170-264AC, SOHz. input Voltage range Overvoltage resistance: 2.3xVin rated/1.3 ms Mains buffering at lout rated min.: 20 ms Bu -oming fuse DC Output: 24VDC/10A Peak to Peak Ripple typ/max : 50/150 my Adjustment Range: 22.8V to 28V via potentiometer Green LED Status Display Efficiency: 90% Output overvoltage protection <33V Short circuit protection Safety entra low output voltage Vout according to 50178 EN and 60950-1 EN Screw type terminals, Rail mounting ‘Supplier should send the detailed specification sheet, module numbers, part numbers along with quotation, failing which quotation will not be considered. Supplier should quote for the entire PLC automation system. Incomplete quotations will not be considered. Order will only be placed for the complete set, not for the individual items in the set. CPU and /O modules should be programmed by STEP 7 TIA V11 programming software, Material should be with latest version available from the original manufacturer. Supplier should provide technical support for installation/testing of the system in an integrated way. Minimum 1-year product warranty should be given. Material should be in original packing.

You might also like