25A
Ref: HO 8-NP/SP33-1000, HO 15-NP/SP33-1000, HO 25-NP/SP33-1000
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation
between the primary and the secondary circuit.
Features Applications
● Hall effect measuring principle
● AC variable speed drives
● Multirange current transducer through PCB
● Static converters for DC motor drives
pattern lay-out
● Battery supplied applications
● Galvanic separation between primary and secondary circuit
● Uninterruptible Power Supplies (UPS)
● Insulated test voltage 4300 V
● Switched Mode Power Supplies (SMPS)
● Low power consumption
● Power supplies for welding applications
● Extremely low profile 12 mm
● The solar inverter on DC side of the inverter (MPPT)
● Fixed offset & sensitivity
● Combiner box.
● Over-current detect 2.63 x IPN (peak value)
● Memory check. Standards
● EN 50178: 1997
Special feature
● IEC 61010-1: 2010
● Single power supply +3.3 V.
● IEC 61326-1: 2012
Advantages ● UL 508: 2010.
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may
degrade reliability.
Standards
● CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01
● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15
Ratings
Parameter Symbol Unit Value
Primary involved potential V AC/DC 600
Max surrounding air temperature TA °C 105
Conditions of acceptability
When installed in the end-use equipment, consideration shall be given to the following:
1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2
environment. 2 - A suitable enclosure shall be provided in the end-use application.
3 - The terminals have not been evaluated for field wiring.
4 - These devices have been evaluated for use in 105°C maximum surrounding air temperature.
5 - The secondary (Sensing) circuit is intended to be supplied by a Isolated Secondary Circuit - Limited voltage circuit
defined by UL 508 paragraph 32.5. The maximum open circuit voltage potential available to the circuit and overcurrent
protection shall be evaluated in the end use application.
6 - These devices are intended to be mounted on a printed wiring board of end-use equipment. The suitability of the
connec- tions (including spacings) shall be determined in the end-use application.
7 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the
terminals. 8 - Any surface of polymeric housing have not been evaluated as insulating barrier.
9 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer, optical
isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other
than through the grounding means).
Marking
Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under
UL's Follow-Up Service. Always look for the Mark on the product.
Page 2/15
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Insulation coordination
At TA = 25°C, UC = + 3.3 V, NP = 1 turn, RL = 10 KΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12).
Parameter Symbol Unit Min Typ Max Comment
Primary nominal rms current I A 8
PN
Note: 1)
Accuracy @ IP and XTA = ± [X + (TCG/10000) · (TA - 25) + TCVOE · 100 · (TA -25) / (Gth · IP)].
Page 4/15
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HO-NP/SP33-1000 SERIES
Electrical data I = 15 A
PN
At TA = 25°C, UC = + 3.3 V, NP = 1 turn, RL = 10 KΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12).
Parameter Symbol Unit Min Typ Max Comment
Primary nominal rms current I A 15
PN
Note: 1)
Accuracy @ IP and X TA = ± [X + (TCG/10000) · (TA - 25) + TCVOE · 100 · (TA -25) / (Gth · IP)].
Page 5/15
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HO-NP/SP33-1000 SERIES
Current consumption I mA 25
C
Note: 1)
Accuracy @ IP and XTA = ± [X + (TCG/10000) · (TA - 25) + TCVOE · 100 · (TA -25) / (Gth · IP)].
Page 6/15
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Typical performance characteristics IPN = 8 A
Gain [0 dB at 50 Hz]
0.2 120
Linearity error (%)
2.0
0.1
60
Phase [deg]
0 0.0
-0.1 0
-0.2 -2.0
-0.3 -60
-0.4 -4.0
-120
-6.0
-180
-0.5 10 100 1000 10000 100000 1000000
-10 -8 -6 -4 -2 0 2 4 6 8 10
Primary current (A) Frequency [Hz]
Vout Ip
Vout Ip
2 µs/div 1 µs/div
20 mV/div
0.3 180
4.0
0.2
Gain [0 dB at 50 Hz]
Linearity error (%)
120
0.1 2.0
0 60
Phase [deg]
-0.1 0.0
-0.2 0
-0.3
-2.0
-60
-0.4
-4.0
-0.5 -120
-6.0
-180
-20 -15 -10 -5 0 5 10 15 20 10 100 1000 10000 100000 1000000
Primary current (A) Frequency [Hz]
Vout Ip
Vout Ip
2 µs/div 1 µs/div
20 mV/div
Gain [0 dB at 50 Hz]
Linearity error (%)
120
0.1
2.0
0 60
Phase [deg]
-0.1 0.0
-0.2 0
-0.3 -2.0
-0.4
-60
-4.0
-0.5 -120
-6.0
-180
-30 -20 -10 0 10 20 30 10 100 1000 10000 100000 1000000
Primary current (A) Frequency [Hz]
Vout Ip
Vout Ip
2 µs/div 1 µs/div
20 mV/div
70
60
50
40
(A)
IP
30
20
10 HO series
0
0 25 50 75 100 125
T (°C)
A
Important notice: whatever the usage and/or application, the transducer jumper temperature shall not go above the maximum
rating of 120 °C as stated in page 2 of this datasheet.
Measuring range with external reference voltage
50
40
Upper limit: IP
= 17.39 × + 48.7 = 0.5 .. 1.65 V)
30
Vref (Vref
20 Lower limit: IP = 17.39 × Vref + 8.7 (Vref = 0.5 .. 1.65 V)
Ip (A)
10
0
-10
-20 HO 8 /SP33
-30
0.5 1 1.5
Vref (V)
80
60 Upper limit: IP = 62.5 (Vref = 0.5 .. 0.883 V)
40
Upper limit: IP = - 32.81 × Vref + 91.3 (Vref = 0.883 .. 1.65 V)
Ip (A)
20
0 Lower limit: IP = -32.81 × Vref + 16.3 (Vref = 0.5 .. 1.65 V)
-20
-40
HO 15 /SP33
-60
0.5 1 1.5
Vref(V)
80
60
40
Upper limit: I
P = 62.5 = 0.5..1.65 V)
20
Ip (A)
(Vref
0 Lower limit: IP = - 54.35 × Vref + 27.17 (Vref = 0.5 .. 1.65 V)
-20
-40
-60 HO 25 /SP33
-80
0.5 1 1.5
Vref(V)
In the following table, examples of primary resistance according to the number of primary turns.
Primary resistance
Number of current rms Primary nominal current
Recommended connections
primary turns IPN [ A ]
RP [ mΩ ]
13 12 11 OUT
1 0.12 8 15 25
IN 8 9 10
13 12 11 OUT
2 0.54 4 7.5 12.5
IN 8 9 10
13 12 11 OUT
3 1.18 2.67 5 8.33
IN 8 9 10
Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values
shown in “typical” graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an
interval with upper and lower limits and a probability for measured values to lie within this interval.
Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that
the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds
to an interval between -3 sigma and +3 sigma. If “typical” values are not obviously mean or average values, those values
are
defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between -sigma and +sigma for a normal
distribution.
Typical, maximal and minimal values are determined during the initial characterization of a product.
Remark
Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic
Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation.
HO name and codification
as example
1)2)3)4)
HO 15-NP/SPXXX-1)2)3)4) The indicate the transducer programming.
1)2)3)4)
HO 15-NP-
1) Reference out:
2.5 V Code: 0
1.65 V Code: 1
1.5 V Code: 2
0.5 V Code: 3
Only Vref IN Code: 4
(Low power mode engaged)
2) Response time:
3.5 s Code: 0
2 s Code: 1
6 s Code: 2
3) Control EEPROM:
YES Code: 0
NO Code: 1
4) Overcurrent detection:
2.9 Code: 0
3.6 Code: 1
4.0 Code: 2
4.8 Code: 3 SET_THRESH = 0
5.2 Code: 4
5.8 Code: 5
1.7 Code: 6
2.3 Code: 7
0.67 Code: A
0.94 Code: B
1.17 Code: C
1.4 Code: D SET_THRESH = 1
1.6 Code: E
1.9 Code: F
2.1 Code: G
2.3 Code: H
Assembly on PCB
• Recommended PCB hole diameter 1.5 mm for primary pin
0.9 mm for secondary pin
• Maximum PCB thickness 2.4 mm
• Wave soldering profile maximum 260 °C, 10 s
No clean process only
Safety
This transducer must be used in limited-energy secondary circuits according to IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in
accordance with the manufacturer’s operating instructions.
Required Connection
OUT
11 12 13
1
+U c
2 47nF
3 0V
5Ω 4.7nF
200Ω 4 47nF
5 V out
>10kΩ
6 V (IN/OUT)
ref
7 OCD
STANDBY