KEY PLAN :

3
E
AS
PH

PROTECTIVE BOARD
CL 2D

50
E
AS
PH
2C

75
ASE
PH
02

VARIES
S-
-O
200mm OVERLAP 2B

1 2B
E E
AS AS
PH PH

25
EXTERNAL CONCRETE
FACE OF WALL 2A
E
WATER PROOF NORTH PH
AS

VARIES 600mm MIN.


20X20mm TANKING MEMBRANE
CHAMFER SEE DETAIL "707f"

WATERPROOF TANKING MEMBRANE

PROTECTIVE BOARD QIBLA


DETAIL-706d
SEE DETAIL "706a" MEMBRANE LAP JOINTS
25mm JOINT FILLET NOTES :
20X20mm
CHAMFER 1.THIS DRAWING IS NOT TO BE SCALED.
SEE DETAIL "706b" 2.REFER TO RELEVANT SURVEY, STRUCTURAL, MECHANICAL, ELECTRICAL,
WALL LANDSCAPE, ETC. CONSULTANT DRAWINGS & SPECIFICATIONS BEFORE
PROCEEDING WITH THE WORK.
3.DETAIL DRAWINGS SHOWN ARE INDICATIVE OF DESIGN INTENT. CONTRACTOR
SEE DETAIL "706d" TO SUBMIT SHOP DRAWINGS AND SAMPLE PER SPECIFICATIONS TO
PROTECTIVE BOARD DESIGNER'S APPROVAL PRIOR TO CONSTRUCTION OR FABRICATION.

OVERLAP
4.CONSTRUCTION MUST CONFORM TO ALL APPLICABLE CODES AND

200
GRP CHAMBER LINER WATER PROOF REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
25X25mm BITUMINOUS TANKING MEMBRANE 5.THE CONTRACTOR WORKING FROM DRAWINGS NOT SPECIFICALLY MARKED
"FOR CONSTRUCTION" MUST ASSUME FULL RESPONSIBILITY AND BEAR COSTS
50mmx50mm CEMENT FOR ANY CORRECTIONS OR DAMAGES RESULTING FROM THIS WORK.
2100 MORTAR FILLET
CONCRETE BASE SLAB
6.THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS PROVIDED BY AND IS THE
PROPERTY OF THE ARCHITECT.
25mm PROTECTIVE SCREED
7.THE CONTRACTOR SHALL VERIFY THE CONTENT OF THIS DRAWING AND SHALL
75mm. OVERLAP NOTIFY THE CONSULTANTS OF ANY DEVIATION OR DISCREPANCY.
200mm OVERLAP SEE DETAIL "706c" 8.CORRECTNESS, BUILDABILITY AND STABILITY OF THE CONSTRUCTION SHALL
25mm PROTECTIVE SCREED REMAIN SOLE RESPONSIBILITY OF THE CONTRACTOR.
75

75mm BLINDING

50mmX50mm CEMENT 200


MORTAR FILLET

CL DETAIL-706e
D

FOR WALL TO BASE JUNCTION

SEE DETAIL "707e"


75mm MEMBRANE OVERLAP PRECAST CONCRETE
EXTENSION RINGS
25mm PROTECTIVE SCREED
75

25mm PROTECTIVE SCREED


200 200

WATERPROOF TANKING MEMBRANE 20X20mm CHAMFER

PROTECTIVE BOARD
25mm PROTECTIVE SCREED
EXTERNAL CONCRETE
WATERPROOF
SURFACE TANKING MEMBRANE

DETAIL-706f
EXTERNAL WATERPROOF TANKING TO MANHOLES DETAIL-706f FOR FIXING MEMBRANE ON SHAFT REVISIONS :
REV. DATE DESCRIPTION
T0 11.12.2019 ISSUED FOR TENDER

PROJECT TITLE :

ARABIAN RANCHES III


PHASE 2A
PROTECTIVE BOARD
AS SPECIFIED 2X20mm CHAMFER
WATERPROOF
TANKING MEMBRANE
3 LAYERS OF MEMBRANE
300mm WIDE CLIENT / DEVELOPER :
2 LAYERS OF MEMBRANE
300mm WIDE

25X25mm FILLET

EXTERNAL CONCRETE SURFACE WATERPROOF


TANKING MEMBRANE

LEAD CONSULTANT :
DETAIL-706a FOR CORNERS DETAIL-706b FOR EDGES

CONSULTANT :
EXTERNAL CONCRETE SURFACE

3 LAYER OF WATER PROOF TANKING


MEMBRANE 300mm WIDE

25X25mm BITUMINOUS
MASTIC FILLET

MEMBRANE UP TO 200mm FROM


ISSUE STATUS :
EDGE OF WALL OR FIRST FLEXIBLE JOINT
ISSUED FOR TENDER

SCALE : NTS DRAWN BY : A.L


PROTECTIVE BOARD AS SPECIFIED

DATE : 11.12.2019 REVIEWED BY : D.A


C:\Users\mary\Documents\08_Revit Local Files 2018\UA18120-A-B-4P3_mary.rvt

TITLE :
DETAIL-706c FOR PIPE ENTRY/OUTLET OF MANHOLE
TYPICAL DETAIL # 08
(STORM SEWER DETAILS)

DRAWING NO. REV NO.

18120-M-00-SW-5008 T0
THIS DRAWING, THE DESIGNS AND DETAILS SHOWN ARE THE COPYRIGHT OF
U+A ARCHITECTS AND SHALL NOT BE COPIED OR REPRODUCED IN ANY
FORM WITHOUT THEIR WRITTEN CONSENT

© U+A ARCHITECTS