Stability Check for Man Hole (WS-SHM) Lug Plate

1. Design Condition.

Material is A36
Tensile Stress, σmax = 70000psi x 0.07031 = 4921Kg/cm2
Welding Size is 8mm = 0.8cm
Safety Factor, FS = 2
P = 25Ton
Load acting on each Lug, P = 25/2 = 12.5Ton

2. Safe Work Load calculation


I. As per max. Shear Stress

From Equation,

Tensile stress, σ = P x FS
A
P=σxAx1
FS
= 4921 x 2.0 x 3.5 x 1
2
= 17223 Kg

= 17.223 Ton

Calculated load, P = 17 Ton > Actual estimated Load, P = 12.5 Ton.


Therefore, OK

II. Weld Strength Check

From Equation,

Tensile stress, σ = P x FS
A
P=σxAx1
FS
= 4921 x [10.5 x 2) + 0.8 x 2] x 1
2
= 54623Kg

= 54 Ton
Calculated load, P = 54Ton > Actual estimated Load, P = 12.5 Ton
Therefore, OK
3. Result
The Lug plate is suitable for lifting the estimated man hole (WS-SHM) Lug plate