SERIES MX
Chemical Injection Pump
Product Features f
* Up to 62 gallons (235 liters) per day 5
* Lightweight i
* Discharge pressures to 10,000 PSI (690 bars) i 2.625
* Adjustable flow rate
* Positive cycle operation
* Easily field serviceable
+ 316 SS fluid end
* Capable of handling dirty/sour gas : rt
* 1 to 60 strokes per minute
* Low gas consumption io | («A
* Inlet pressure: 145 PSI (10 bars) maximum
30PSI (2.1 bars) minimum
* Adjustable vee packing
fe o95 6
go %
7.633
12.50
Model Number
Plunger Diameter | Pump Model Number | Weight |
Mx-4 125+
MK-T Me
MKS 4
" MKS 15¢
Wo.
tem | No, | Red, Name Material | i
1_| tear 1_| Power unit
2 | meso 1_| wippie sst
3_| tases 1_| Speed Control Valve Aluminum
«| torsss 1 | Yoke cover Wt Shown) | Paste
5 | Povamasnanoo] 4 | wots Shg-2UNFx2p | sst
| roan 1 [Yoke Housing| | Alurina
7 | ass 1_| brive cup sst
8 | tea 1 | uid Ene Assembiy
"Vg" Plunger Assembly1/4 NPT
Discharge
NN
2.078—=} 1/4 NPT
Suction
Double Headed
MX-Pump
Accessories
0O@Oo
Mounting Bracket
Muffler, 17," N.P.T.
"
Lubricator
i
FilterSERIES MX
Installation and Operation
1. Remove the pump from the shipping container and inspect for visual damage
2. Connect the chemical supply line to the pump suction port. The pump suction port connection is 1/4” FNPT.
NOTE: Simplex pumps should be mounted in vertical position with the suction port facing down, (brackets are
available to assist in mounting). Duplex pumps should be mounted in horizontal position with suction ports
facing down (mounting feet are available).
3. Connect tubing or piping to the discharge port to the pump. The discharge port connection is 1/4” FNPT and
perpendicular to pump plunger axis.
NOTE: TXT recommends the installation of a line check at the point of injection into the line.
4. Loosen the lock nut on the fluid end/yoke connection and rotate the power unit to align the control valve in a
suitable location for installation requirements (care should be taken not to rotate the power more than 180
degrees}. Retighten locknut upon completion.
5. Install a shut-off valve in the air/gas supply line.
6. Connect a 1/4” line from the air/gas shut-off to control valve.
7. The pump supply air/gas pressure must be a minimum of 30 PS! but no greater than 145 PSI. If the available sup-
ply pressure is greater than 145 PSI a regulator must be installed to reduce the pressure to an acceptable level.
NOTE: For the best trouble free performance, a filter and lubricator should be installed in the air/gas supply line.
8. Open the supply line shut-off valve to the pump. The stroke rate is controlled by adjusting the calibrated
contral valve.
9. Exhaust air/gas should exit the power unit through the exhaust ports located on both sides of the control valve
connection into the power unit.
10.Open the priming valve on the side of the fluid housing, (approximately 1/2 turn to allow trapped air to escape
from the head.) Continue to cycle the pump with the priming valve open until air bubbles are no longer visible in
the fluid stream coming from the bleed hole.
NOTE: The media from the bleed hole can be piped to a container for safety purposes.
11.Control the output volume of the pump by adjusting the calibrated control valve. The pump can be operated at a
stroke rate between 1 SPM minimum to a maximum of 60 SPM.
12, Once desired volume is established, the number on the barrel of a calibrated control valve should be noted, for
returning to the same stroke rate and pump volume in the future.MX Pump
Gallons Per Stroke
MX Pump
Gas Consumption
SERIES MX
0.06 Gallons ‘SCF per Gallon
|
0.05 tae |
1/2 Plunges
0.04
|
0.03 MKS 1
Plunger
2230 «4050
Strokes
1° Max Stroke Length
MX Pump Capacity
(Max Supply Press, 145 PSI)
Gallons Per Day
K!
1/2'Plunger
5 1 15 20 25 30 35 40 45 50
Discharge Pressure (PSIG)
Discharge Press (000)
1
Pressure/Volume
[ Valume
Model | Max ischarge | Maximum Minimum
Number | PSI BARS | GPO LP GPO PD
Mx4 He PLGA |1000 690 | 20 wa] 2
a | mx % PuGR [1000 690 [4s sa] 2 75
| al | MXS % pice | 6000 414 [21 ais | 6 227
al aiflunjer_| | Mx5 Vp PUGR | 3500 2 [ozo 247 [11 416
— Mx-1
10
x4
Plunger
3°94 5 6 7
Discharge Pressure PS! (000)SERIES MX
Fluid End Parts List
tom | Description | Material | ay | ane | va | am | ue
Fluid End Assy year | rox | team | ree
[Jody wesS_ | 1 | tears | eave | tea | reeves
2 [unger | v-ee |_| tasase | tasaea | tasaro | Tagan
3 [Packing Giené | aosss_ |r| tasoea_| tavess_| Tacesr_[ Tatars ]
[a [Packing une —|"aosss— |_| tasiow ) Ttasios | Tastos | Tastos
rt Buna “ase6e_| Tatas] TANSS6 | Tams
[ton as867 | Tani | Tasior | Taste
5. | Packing Teton asues | tavose_| tarzoe_ | Tatora
HP-Buna “aases_ | tazs_| Tasers | TaNe7s
HPV Tasass_| vaszes | tases | TAR265
@ [Top Bushing | 85 1 [tates _[taress [tas Taras6
7_[Uarge bane" [sess | 1_| Taaose | Tasos | Taoose | Tamnse
[s [sancxsping [sess [1 | tanorr | taoor | taaar | taco
Buna |[teors7_|reorsr | reors7_|~raorsr
9 | seat Vion Taoess_| Tenet | Tooses_|Ta0e
Taton anse6 | rerss6 | TaTs96
Buna Teor |_Taors6 | Teor | Ta0T3s
10 | Bottom Bushing | Viton ‘Teuess | Teese | Teoess | Teoees
[etion weiss? | Toiss? | Tense
[Priming Vave [ates [1_[ taeore | tasare | Tasare | Taare
12 [Smaniai ve" | 3168s 1 | taoree | taares | taoiee | Tanrze
13_|Pwv Spring | 88 1 tasara [asa | asora | raszra
1 [Losk ut Brass | 1 | tacos | amas | taozas_[ra0azs
15 Spina Ba Cone] SS 1_|tassre_[ tase [tase _[ Tassie
15 [O-Ring 1
Rapa Ki [Bune sweats | raesize [tassi38 | ras
uid End Assembly [Viton ‘aesi-v | tar2. | TART. V | TABSIA
Teton Tassr2eT [Tees | Tasoa-t
Volume Conversion
tele x 095 oH
eeimin x 0018 CPA]
rg 0026 Pe
inarisee x 8520 GH r Pressure Conversion Factors ]
ia > — ha} oa Kase [xz [= ae
imperial GPM |x. 720 ‘GPH nde eas | 049 | ee
imperial PH | —x 120 PH) Tn, Water a one FS
mead ae aH FrotWatr [x a PSIG]
min 001 ‘Atmospheres |» 187 PsiG
rhe x 000026 |= PH Wa tKia/Paseal) | 0180
[mane x 2642 eH [Moa Pa x 1450
Conygh=88 by Testa
‘Avighe reread. Priced nUSA,
Feprductonn whale 9a prnied by la,
QUALITY & SERVICE SINCE 1954
ml