You are on page 1of 5
SERIES MX Chemical Injection Pump Product Features f * Up to 62 gallons (235 liters) per day 5 * Lightweight i * Discharge pressures to 10,000 PSI (690 bars) i 2.625 * Adjustable flow rate * Positive cycle operation * Easily field serviceable + 316 SS fluid end * Capable of handling dirty/sour gas : rt * 1 to 60 strokes per minute * Low gas consumption io | («A * Inlet pressure: 145 PSI (10 bars) maximum 30PSI (2.1 bars) minimum * Adjustable vee packing fe o95 6 go % 7.633 12.50 Model Number Plunger Diameter | Pump Model Number | Weight | Mx-4 125+ MK-T Me MKS 4 " MKS 15¢ Wo. tem | No, | Red, Name Material | i 1_| tear 1_| Power unit 2 | meso 1_| wippie sst 3_| tases 1_| Speed Control Valve Aluminum «| torsss 1 | Yoke cover Wt Shown) | Paste 5 | Povamasnanoo] 4 | wots Shg-2UNFx2p | sst | roan 1 [Yoke Housing| | Alurina 7 | ass 1_| brive cup sst 8 | tea 1 | uid Ene Assembiy "Vg" Plunger Assembly 1/4 NPT Discharge NN 2.078—=} 1/4 NPT Suction Double Headed MX-Pump Accessories 0O@Oo Mounting Bracket Muffler, 17," N.P.T. " Lubricator i Filter SERIES MX Installation and Operation 1. Remove the pump from the shipping container and inspect for visual damage 2. Connect the chemical supply line to the pump suction port. The pump suction port connection is 1/4” FNPT. NOTE: Simplex pumps should be mounted in vertical position with the suction port facing down, (brackets are available to assist in mounting). Duplex pumps should be mounted in horizontal position with suction ports facing down (mounting feet are available). 3. Connect tubing or piping to the discharge port to the pump. The discharge port connection is 1/4” FNPT and perpendicular to pump plunger axis. NOTE: TXT recommends the installation of a line check at the point of injection into the line. 4. Loosen the lock nut on the fluid end/yoke connection and rotate the power unit to align the control valve in a suitable location for installation requirements (care should be taken not to rotate the power more than 180 degrees}. Retighten locknut upon completion. 5. Install a shut-off valve in the air/gas supply line. 6. Connect a 1/4” line from the air/gas shut-off to control valve. 7. The pump supply air/gas pressure must be a minimum of 30 PS! but no greater than 145 PSI. If the available sup- ply pressure is greater than 145 PSI a regulator must be installed to reduce the pressure to an acceptable level. NOTE: For the best trouble free performance, a filter and lubricator should be installed in the air/gas supply line. 8. Open the supply line shut-off valve to the pump. The stroke rate is controlled by adjusting the calibrated contral valve. 9. Exhaust air/gas should exit the power unit through the exhaust ports located on both sides of the control valve connection into the power unit. 10.Open the priming valve on the side of the fluid housing, (approximately 1/2 turn to allow trapped air to escape from the head.) Continue to cycle the pump with the priming valve open until air bubbles are no longer visible in the fluid stream coming from the bleed hole. NOTE: The media from the bleed hole can be piped to a container for safety purposes. 11.Control the output volume of the pump by adjusting the calibrated control valve. The pump can be operated at a stroke rate between 1 SPM minimum to a maximum of 60 SPM. 12, Once desired volume is established, the number on the barrel of a calibrated control valve should be noted, for returning to the same stroke rate and pump volume in the future. MX Pump Gallons Per Stroke MX Pump Gas Consumption SERIES MX 0.06 Gallons ‘SCF per Gallon | 0.05 tae | 1/2 Plunges 0.04 | 0.03 MKS 1 Plunger 2230 «4050 Strokes 1° Max Stroke Length MX Pump Capacity (Max Supply Press, 145 PSI) Gallons Per Day K! 1/2'Plunger 5 1 15 20 25 30 35 40 45 50 Discharge Pressure (PSIG) Discharge Press (000) 1 Pressure/Volume [ Valume Model | Max ischarge | Maximum Minimum Number | PSI BARS | GPO LP GPO PD Mx4 He PLGA |1000 690 | 20 wa] 2 a | mx % PuGR [1000 690 [4s sa] 2 75 | al | MXS % pice | 6000 414 [21 ais | 6 227 al aiflunjer_| | Mx5 Vp PUGR | 3500 2 [ozo 247 [11 416 — Mx-1 10 x4 Plunger 3°94 5 6 7 Discharge Pressure PS! (000) SERIES MX Fluid End Parts List tom | Description | Material | ay | ane | va | am | ue Fluid End Assy year | rox | team | ree [Jody wesS_ | 1 | tears | eave | tea | reeves 2 [unger | v-ee |_| tasase | tasaea | tasaro | Tagan 3 [Packing Giené | aosss_ |r| tasoea_| tavess_| Tacesr_[ Tatars ] [a [Packing une —|"aosss— |_| tasiow ) Ttasios | Tastos | Tastos rt Buna “ase6e_| Tatas] TANSS6 | Tams [ton as867 | Tani | Tasior | Taste 5. | Packing Teton asues | tavose_| tarzoe_ | Tatora HP-Buna “aases_ | tazs_| Tasers | TaNe7s HPV Tasass_| vaszes | tases | TAR265 @ [Top Bushing | 85 1 [tates _[taress [tas Taras6 7_[Uarge bane" [sess | 1_| Taaose | Tasos | Taoose | Tamnse [s [sancxsping [sess [1 | tanorr | taoor | taaar | taco Buna |[teors7_|reorsr | reors7_|~raorsr 9 | seat Vion Taoess_| Tenet | Tooses_|Ta0e Taton anse6 | rerss6 | TaTs96 Buna Teor |_Taors6 | Teor | Ta0T3s 10 | Bottom Bushing | Viton ‘Teuess | Teese | Teoess | Teoees [etion weiss? | Toiss? | Tense [Priming Vave [ates [1_[ taeore | tasare | Tasare | Taare 12 [Smaniai ve" | 3168s 1 | taoree | taares | taoiee | Tanrze 13_|Pwv Spring | 88 1 tasara [asa | asora | raszra 1 [Losk ut Brass | 1 | tacos | amas | taozas_[ra0azs 15 Spina Ba Cone] SS 1_|tassre_[ tase [tase _[ Tassie 15 [O-Ring 1 Rapa Ki [Bune sweats | raesize [tassi38 | ras uid End Assembly [Viton ‘aesi-v | tar2. | TART. V | TABSIA Teton Tassr2eT [Tees | Tasoa-t Volume Conversion tele x 095 oH eeimin x 0018 CPA] rg 0026 Pe inarisee x 8520 GH r Pressure Conversion Factors ] ia > — ha} oa Kase [xz [= ae imperial GPM |x. 720 ‘GPH nde eas | 049 | ee imperial PH | —x 120 PH) Tn, Water a one FS mead ae aH FrotWatr [x a PSIG] min 001 ‘Atmospheres |» 187 PsiG rhe x 000026 |= PH Wa tKia/Paseal) | 0180 [mane x 2642 eH [Moa Pa x 1450 Conygh=88 by Testa ‘Avighe reread. Priced nUSA, Feprductonn whale 9a prnied by la, QUALITY & SERVICE SINCE 1954 ml

You might also like