CONCRETE PILES - TEST PILE

Note: Good for one(unit) only

Length Unit
Test Pile = 16 m

Description Ø Quantity Splicing No. of Commercial Length

Longitudinal Reinforcements 32 8 1.700 32-32mmØ x 9m

Spiral Reinforcements
Height = 16.000 m
Pitch = 0.100 m
Circumference = 1.100 m
No. of Pitch = 160.000
Total Length = 176.726 m
Splicing Length (40D) = 0.400 m

Description Ø Quantity Splicing No. of Commercial Length

Spiral Reinforcements 10 1 0.400 64-10mmØ x 6.0m


CONCRETE PILES - REGULAR PILE
Note: Good for one(unit) only

Length Unit
Test Pile = 12 m

Description Ø Quantity Splicing No. of Commercial Length

Longitudinal Reinforcements 32 8 1.700 192-32mmØ x 12m

Spiral Reinforcements
Height = 12.000 m
Pitch = 0.100 m
Circumference = 1.100 m
No. of Pitch = 120.000
Total Length = 132.544 m
Splicing Length (40D) = 0.400 m

Description Ø Quantity Splicing No. of Commercial Length

Spiral Reinforcements 10 1 0.400 576-32mmØ x 6.0m