Power Section Specification (Imperial Units) 700-7864 (B)

7" 7:8 Lobes 6.4 Stages


Rotor Specifications Stator Specifications Performance Specifications
Overall Length 232.5 in. Overall Length 250.0 in. Flow Range 300-600 GPM
Avg. Diameter 3.939 in. Tube OD 6.750 in. Rev per Unit Volume 0.305 Rev/Gal
Contour Length 225.5 in. Contour Length 234.00 in. Speed Range 91-183 RPM
Eccentricity 0.243 in. Tube ID 5.500 in. No Load Pressure Loss 151 psi
Major Diameter 4.425 in. Rubber Cut-back RR-UF100D-UF180 UF114 POB-PRR 280XT
Head Diameter 4.000 in. Side 1: 8.000 in. Max ∆ Pressure 1,010 psi - 1,520 psi -
Head Length 7.00 in. Side 2: 8.000 in. Max Torque 8,740 ft-lbs - 13,110 ft-lbs -
Weight 782 lbs Weight 939 lbs Stall ∆ Pressure 1,520 psi - 2,280 psi -
Thread Form 2 7/8" API Reg Material Alloy Steel Stall Torque 13,110 ft-lbs - 19,660 ft-lbs -
Stator Minors and Fit (in.) at 70℉
Nomenclature RR UF100D-UF180 UF114 POB-PRR 280XT
Size Monoflo R&M Monoflo Fit R&M Fit R&M Fit R&M Fit Monoflo Fit R&M Fit Monoflo Fit R&M Fit
T
0 S 3.949 -0.010 3.942 -0.003
1
2
3
4
5
6
7
8
Reline Lengths (in.) Monoflo: Max 250.1 Min 238 R&M: Max 0 Min 0 Alternate Stator OD: 6.75 (in.)

Torque Fit Increase


16000 0.1
14000
Fit Increase (in)

0.08
Torque (ft-lbs)

12000
10000 0.06
8000
6000 0.04
4000
0.02
2000
0 0
0 250 500 750 1000 1250 1500 1750 0 50 100 150 200 250 300
Differential Pressure (psi) Change In Temperature (°F)
Speed Mechanical Power
250 500
Mechanical Power (hp)

200 400 600 GPM


Speed (rpm)

600 GPM
150 300
450 GPM
450 GPM
100 200
300 GPM 300 GPM
50 100

0 0
0 250 500 750 1000 1250 1500 1750 0 250 500 750 1000 1250 1500 1750 2000
Differential Pressure (psi) Differential Pressure (psi)
©2016 NOV. All rights reserved. Except as noted, all trademarks referenced in this document are trademarks of NOV. PS App v. 3.2.1221
Performance curves describe theoretical performance with 175℉ (79℃) water and are for reference only. Operational fit and drilling conditions will affect performance. Operation
above maximum recommended limits will reduce life. Specification data are subject to change without notice.