A B C D E: Raft Reinforcement Details

You might also like

You are on page 1of 1

TITLE:

Raft Reinforcement
A B C D E Details
52'-9"
9'-412" 19'-412" 19'-412" 4'-712"
SCALE:
Please do not scale drawing, follow the written dimensions.
4'-712" In case of any ambiguity, Contact the Consultant

DATE:
January, 2021
NOTES: 1. Safe Bearing Capacity=0.88 T/SFT
2. In any case foundation should not be placed on loose soil.
Bottom Steel 3. Granular material (Durrah) of 12'' in One Layer provided beneath
foundation.
#4@6'' C/C 4. If any adverse variety of soil over bearing capacity found during
construction then achieve 95% MDD by performing FDT Test.
Both Ways 5. Loose Soil should be compacted first.
1
20'-10 "
2 SHEET NO. : JOB NO. :

S-04 115
PROJECT:
Top Steel Proposed Plan of Commercial
#3@8'' C/C Building Belongs To Adil
Both Ways
Ahmad S/O Rukhsar Ahmad
situated at Jandawala Tehsil
56'-9"
Kharian District Gujrat
COPYRIGHTS:
20'-1012"
This drawing is the intellectual property of RAZA
DESIGNERS & BUILDERS. Any use of this drawing
without the express written consent is prohibited and
will cause legal action to be taken against the user.
Not Authorized to commence any civil works at site
without supervision of Qualified Engineer.

10'-412" HAMZA ARCHITECT


Consulting Architect
Gulbarg Road, Lalamusa
0331-5831787

A B C D E RAZA DESIGNERS &


BUILDERS
Consulting Engineers
SCALE Butt Plaza, G.T Road
Lalamusa.
0334-0121200

You might also like