Professional Documents
Culture Documents
Mobile Wimax: Installation Manual
Mobile Wimax: Installation Manual
Mobile WiMAX
Installation Manual
Base Station
(IDU Ver1/1TRX ODU)
IMN:BS
NEC Corporation
Copyright 2007, 2008 by NEC Corporation
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means, including electronic, mechanical, photographic, or magnetic,
without prior written permission of the publisher.
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their own
purposes violates the rights of their owners.
Printed in Japan
Preface
Table of Contents
1. Introduction..................................................................................................................... 8
2. IDU Installation............................................................................................................. 15
5. BS Power-On ................................................................................................................. 61
1. Introduction
1.1 Overview
The outline drawing of a Base Station (BS) is shown below.
ODU
CHC
(Sector card)
ODU
ODU
CHC
(Sector card) ODU
NW INTFC
to ASN-GW
This manual describes the installation procedures for Indoor Unit (IDU) and Outdoor Unit
(ODU).
WARNING: This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
All electrical and electronic products should be disposed of separately from the municipal
waste stream via designated collection facilities appointed by the government or the local
authorities.
The correct disposal and separate collection of your old appliance will help prevent
potential negative consequences for the environment and human health. It is a
precondition for reuse and recycling of used electrical and electronic equipment.
For more detailed information about disposal of your old appliance, please contact your
sales representative.
The statements quoted above are only fully valid for equipment which is installed in the
countries of the European Union and is covered by the directive 2002/96/EC.
Countries outside the European Union may have other regulations regarding the disposal
of electrical and electronic equipment.
Laser Warning
To avoid damage to health, you must observe the regulations regarding protection against
radiation from laser devices. You must always use dedicated laser-protective goggles.
Never look into open fiber-optic cable ends, as this may damage your eyes.
FUN continues rotating for a while after removing FUN UNIT. Do not touch it.
The instructions marked by symbol are especially important for safety. Always follow the
instructions.
Please use the following calculated data of Compliance Boundary by installation for making a
restricted access area with sufficient safety distance, and to ensure that people are outside this
Compliance Boundary.
Lhf 2.1m
Lhb 0.66m
Lv 0.66m
(Include safety margin (0.5m))
Lhf 2.1m
Lv 0.66m
(Include safety margin (0.5m))
2. IDU Installation
2.2.1 IDU
Name Plate
Front view
FILTER
NW INTFC
FAN UNIT
ASN-GW POWER
IN
POWER
OUT
When carrying this equipment, be careful not to hurt your hands with the projections,
external connection cables, etc.
Tightening Torque
Size
{N – m}
M5 2.64
IDU
IDU
IDU
(Front) (Front)
(Front)
The following figure shows the required space when installing IDU.
(Front)
(250mm)
IDU
In the following section, the adaptation of the Racks to the flange positions is shown and the
procedure to change the flange position is described.
Mounting Pattern
Standard 125mm Offset
19 inch Yes Yes
19 inch IEC60917 (JIS C6010) Yes Yes
ETSI Yes Yes
*50mm offset is to be the standard, because the front side space is 25mm.
D2
D1 Mounting side
Cover
Front side
Figure 2-8 Dimensions of Supported Rack
M4 (4 places each
for both sides)
M4 (4 places each
for both sides)
Figure 2-10 Changing Flange Positions (19 Inch Rack to JIS C6010 Rack)
M4 (4 places each
for both sides)
M4 (4 places each
for both sides)
Figure 2-12 Changing Flange Positions (19 Inch Rack to JIS C6010 Rack)
M5 (4 places)
5U
CHC3
(Sector card 3)
CHC2
(Sector card 2)
NW INTFC
IN
Remove the cap before insertion
Optical cables have a specified minimum cable bend radius. Falling under this
limit may cause increase in loss and cable break. Also, twisting the optical cable
may break it.
Must be more
than R30 at all
times
Figure 2-17 How to Handle Optical Cables (When Using NEC-Recommended Cable)
Circular
groove
The following image shows the appearance of the lightning protector (manufactured by
Huber-Shuhner, 3403.17.0050).
Signal
No Signal Name I/O Content No I/O Content
Name
Reserved for
1 DI0(+) I
monitoring 1 Reserved for
14 DI0(-) I
Reserved for monitoring 1
2 DI1(+) I
monitoring 2 Reserved for
15 DI1(-) I
Reserved for monitoring 2
3 DI2(+) I
monitoring 3 Reserved for
16 DI2(-) I
Reserved for monitoring 3
4 DI3(+) I
monitoring 4 Reserved for
17 DI3(-) I
monitoring 4
5
18
Reserved for
6 DO1(M) O
monitoring 1 Reserved for
19 DO1(C) O
Reserved for control 1
7 DO1(B) O
monitoring 1 Reserved for
20 DO2(M) O
Reserved for control 2
8 DO2(C) O
monitoring 2 Reserved for
21 DO2(B) O
Reserved for control 2
9 DO3(M) O
monitoring 3 Reserved for
22 DO3(C) O
Reserved for control 3
10 DO3(B) O
monitoring 3 Reserved for
23 DO4(M) O
Reserved for control 4
11 DO4(C) O
monitoring 4 Reserved for
24 DO4(B) O
ALM(M) control 4
12 O IDU ALM
ALM(N.C.) ALM(C)
25 O IDU ALM
ALM(B) ALM(COM)
13 O IDU ALM
ALM(N.O.)
6,7,19 DO1(M,B,C) External output 1 Short between M and Short between B and C pins
C pins (Note 2)
8,20,21 DO2(M,B,C) External output 2 Short between M and Short between B and C pins
C pins (Note 2)
9,10,22 DO3(M,B,C) External output 3 Short between M and Short between B and C pins
C pins (Note 2)
11,23,24 DO4(M,B,C) External output 4 Short between M and Short between B and C pins
C pins (Note 2)
Notes:
1 Notify state change (Level determination) to EMS.
2 Controlled by control message from EMS.
3 When power is OFF, use short between B-C pins (=Alarm).
Before normal activation, and when “IDU ALARM” is output, use Active (GPIO[1]).
During normal operation, use Inactive (GPIO[0]).
13 1
EXT I/O
25 14
3. ODU Installation
Belt
Mounting
Bracket
ODU
Equipment
Name Plate
Belt
Mounting
Bracket
ODU
Equipment
Name Plate
ANT(TX/RX) OPT
MAINT
FG
-48VDC
ANT(TX/RX) -48VDC
MAINT
OPT
FG
When carrying this equipment, be careful not to hurt your hands with the projections,
external connection cables, etc.
Tightening Torque
Size
{N – m}
M12 38±10%
M5 2.64
[Installation Procedure]
Mounting Bracket
M12 bolts
4 places
2 Hand the ODU to the mounting bracket on the pole, and fix the bottom
mounting bracket with a belt.
Belt
Equipment weighs 18kg, so when removing it hold the bottom surface firmly and be
careful not to drop it.
Dust-proof caps are not waterproof. When using this equipment outdoors, always
perform the specified cable connections and installations.
1 Remove the M5 screw and install the circular terminal for M5.
図 1-7 FG ケーブル接続図
2 Replace the M5 screw, then apply the silicon caulks around the M5 screw.
Silicon Caulks
If the following points are not noted, ODU may break, or the O&M personnel may suffer
from high-frequency burn.
Connect antenna terminal cable before turning ODU power ON.
When ODU power is ON, do not remove the antenna terminal cable.
As a lightning surge measure, connect the arrester to the connecting part of the antenna port.
Protective range
Antenna
Ground Power connector
connecting
terminal
(outdoor)
Arrester
ODU
FG of ODU
Indoor
Ground connecting terminal (indoor)
-48V Power
FG of the power
Ground
Optical cables have a specified minimum cable bend radius. Falling under this limit may
cause increase in loss and cable break. Also, twisting the optical cable may break it.
4. BS Connection Diagrams
IDU
CHC3 CHC IN
( Sector 2
(Sector
S a m ea s C H C 1 (S e c to r ca rd 1 )
card 3 ) OUT
card) ANT
IN
1
protector
OUT
ANT
To GND
CHC2 CHC IN Coaxial
( Sector 2 cable GND cable protector
card 2 ) (Sector OUT Screw
card) FG To GND
IN
1 Coaxial GND Cable
N/J ANT cable
To Power Supply
OUT (TX/RX) ODU Screw
Breaker DC -48V FG
CHC1 CHC IN IN Power cable
OPT
( Sector 2 N/J ANT
card 1 ) (Sector OUT OUT Optical cable (TX/RX)
ODU
card) IN IN
Dedicated
connectors
To Power Supply Breaker
Power cable
DC -48V
1 OPT
OUT OUT Optical cable
Dedicated
LC connectors
5. BS Power-On
1 Before turning the main power circuit breaker (MAIN) on the NW INTFC of
the IDU ON, check that all toggle switches on CHCs (Sector cards) are OFF
(O side).
2 Turn on the breaker for the ODU. (There is no power switch on the ODU.)
3 Turn on the main power circuit breaker POWER on NW INTFC of the IDU.
PWR LED on the front of NW INTFC lights in green.
1 At this time, FAN UNIT operates. FAN LED on the front of NW INTFC does
not light. (FAN LED, used as FAN ALM, lights only when a fan alarm occurs.)
2 Also, the GPS receiver operates, with WARN LED lighted. WARN LED goes
out upon completion of GPS synchronization.
3 Switch on the CHC1 (Sector card 1) toggle switch (pull it and set it from O to
|). PWR LED on the front of CHC1 (Sector card 1) lights in green.
Pull towards
yourself and fold it
in the direction of
arrow
4 Switch on the CHC2 (Sector card 2) toggle switch (pull it and set it from O to
|). PWR LED on the front of CHC2 (Sector card 2) lights in green.
5 Switch on the CHC3 (Sector card 3) toggle switch (pull it and set it from O to
|). PWR LED on the front of CHC3 (Sector card 3) lights in green.
You can carry out steps to turn on the CHC1 (Sector card 1) to CHC3 (Sector card 3) in any
order.
GPS
Antenna
Lightning
Rod
Sector
Antenna
ODU
Ca
b ine
t Ba
Ro Ca ttery
oft bin
op et
GPS
Antenna
Lightning
Rod
Sector
Antenna
ODU
Ca
bin
et Ba
Ca ttery
Ro bin
oft et
op
GPS
Antenna
Lightning
Rod
ODU
Sector
Antenna
Ro Ca
b ine
oft t Ba
op Ca ttery
bin
et
GPS
Antenna
Lightning
Rod
Sector
Antenna
ODU
Ca
Ro bin
et
oft Ba
Ca ttery
op bin
et
GPS
Antenna
Lightning
Rod Sector
ODU Antenna
Ro
oft
op
Ca
b ine
t Ba
Ca ttery
bin
et
to Power Supply
GPS
Antenna
Lightning
Rod
Sector
Antenna
ODU
Ca
b ine
t Ba
Ro Ca ttery
oft bin
op et
ODU
Battery
Cabinet
Cabinet
to Power Supply
SEC SEC
Antenna Antenna
RF Cable
RF Cable
Penthouse AC Power
Cable
Transmission
SEC Cable
500mm
Antenna
/GPS
Antenna
DC Power Cable
GPS RF Cable
780mm
RF Cable
740mm
Cabinet Battery
Cabinet
400mm
Lightning rod
Lightning rod
Lightning rod
AC PDB
Rectifier
Protector
Protector
Protector
Protector
Protector
Protector
Protector
BATT
BATT
ODU
ODU
ODU
ODU
ODU
ODU
Pole
Pole
Pole
FAN
IDU
Cable 600V CV (5.5sqmm 3C)
Blac L
AC Red N
110V Clea G
Cable 600V IV (8sqmm)
L - Blue Yellow Yellow
Red Yellow Yellow
L +
Cable 600V IV - 48V
NFB 1 - Blue
Red
A1
+ B1
NFB 2
- Blue
Red
A2
+ B2
Cable 600V IV TB1
NFB 3 - -
+ +
SEC Antenna
SEC Antenna
SEC Antenna
SEC Antenna
SEC Antenna
SEC Antenna
NW INTFC
Swich Box
Protector
Protector
Protector
Protector
Protector
Protector
Protector
CHC 1
CHC 2
CHC 3
ODU
ODU
ODU
ODU
ODU
ODU
Gb Ether Cable
Internal connection
(*1): 12D-SFA is unnecessary when the distance between GPS ANT and IDU is 15m or less.
ASN IDU (*2): It is necessary to use 12D-SFA when the cable length is 14m or more.
1
2
3 Rectifier 3U
4
5
6 Reserved for PDP 3U
7
8 IDU (CHC3)
9 IDU (CHC2)
10 IDU (CHC1) 5U
11
IDU (NW INTFC)
12
13
14
Space (for future use) 4U
15
16
17
18 AC-Terminal 3U
19
20
SUS Diameter
500 3/4" Manage
500 12
GPS
NO.: 1 pcs
Material: SS41
Hot Dip Galvanizing
1000
400
2972.90
2
150
NO. Materials
1 Bearing of ground SUS 1/2" x 3.5"L - 8pcs, Expansion bolt.
2 Hot Dip Galvanizing M12 x 1.75P x 50 - 8pcs.
SUS Diameter
500
3/4" Manage
500 12
GPS
NO.: 1 pcs
Material: SS41
Hot Dip Galvanizing
1000
400
2972.90
3
2
4
150
500
H Beam 150 x 150 x 500
NO. Materials
1 Foundation: L70 cm x W70 cm x H15 cm.
2 SUS 1/2" x 3.5"L - 8pcs, Expansion bolt.
3 Hot Dip Galvanizing M12 x 1.75P x 50L - 8pcs.
2 1/2"
2000
3
1030
NO.: 1 pcs
Material: SS41
Hot Dip Galvanizing
150
100 358
1000
2
1
150
NO. Materials
1 Hot Dip Galvanizing M12 x 1.75P x 50 - 8pcs.
2 Bearing of ground SUS 1/2" x 3.5"L - 8pcs, Expansion bolt.
150
100 358
1000
2
1
150
398 1491
NO. Materials
1 Hot Dip Galvanizing M12 x 1.75P x 50 - 8pcs.
2 Bearing of ground SUS 1/2" x 3.5"L - 8pcs, Expansion bolt.
NO.: 1 pcs 1
Material: SS41
Hot Dip Galvanizing
350
2
300 25 148
180
35
100
85
420
490
290
320
90 77
4-
20
238 56
6
3
48
360
This item weighs 13 kg. (Excluding Equipment)
NO. Materials
1 SUS 3/8" x 2"L - 4pcs, Expansion bolt.
2 SUS M10 x 1.5P x 20L - 4pcs, Cast the bolt in advance.
3 SUS 3/8" x 2"L - 1pcs, Expansion bolt.
GPS
Lightning rod
2
3
1000
2308
25
ODU
550
NO. Materials
1 SUS 3/8" x 2"L - 4pcs, Expansion bolt.
2 SUS M10 x 1.5P x 20L - 4pcs, Cast the bolt in advance.
3 SUS 3/8" x 2"L - 1pcs, Expansion bolt.
NO. Materials
1 Foundation L170 cm x W85 cm x H12 cm.
2 SUS 1/5" x 6"L - 6pcs, Cast the bolt in advance.
2 1
NO. Materials
1 SUS 304 C25 x 40 x 1.5t.
2 SUS 1/4" x 1/2"L - 2pcs.
NO. Materials
1 SUS 304 L40 x 40 x 3t. L Angle w/long hole.
3 2 SUS 304 C25 x 40 x 1.5t.
4 3 Foundation L10 cm x W10cm x H12 cm.
1 4 Waterproof paint of PU elasticity.
8 7 6 5
NO. Materials
1 2"52mm x 4mm
2 1 1/2" 41mm x 3.5mm
4 3 2 1 3 1"28mm x 3mm
4 3/4"20mm x 3mm
5 SUS 2" x 2mm
6 SUS 1 1/2" x 2mm
7 SUS 1" x 2mm
8 SUS 3/4" x 2mm
2 NO. Materials
1 SUS 304 C25 x 40 x 1.5t.
2 SUS 1/4" x 1/2"L - 2pcs. (mount in floor)