Professional Documents
Culture Documents
Ionicore
INDEX
Variants
Code Description
04606001-01 Ionicore assembled installation kit IN-OUT 1/4"-1/4" - wall plug 3/8"
04606001-02 Ionicore assembled installation kit IN-OUT 1/4"-6mm. - wall plug 3/8"
04606001-03 Ionicore assembled installation kit IN-OUT 1/4"-8mm. - wall plug 3/8"
04606001-04 Ionicore assembled installation kit IN-OUT 3/8"-3/8" - wall plug 3/8"
04606001-05 Ionicore assembled installation kit IN-OUT 3/8"-10mm - wall plug 3/8"
Ionicore assembled installation kit ready for installation with Hydraulic fitting "T" to intercept the water
directly on cold water flexible, with:
- Hydraulic fitting Tee F.F.M. 3/8";
- Digiflow 8000T LCD filter life Water meter time/metered in liters;
- Ionicore IH2 filter head.
You can drink immediately microfiltered or ultra-filtered water by adding a Ionicore filter and a 1-way faucet
or 3-way mixer faucet.
Features
Water Wall inlet: 3/8" Male Female
DMfit output pipe: from 1/4" to 10MM.
Flow rate: varies according to installed cartridge 3,78/7,56 lt./min. (1/2gpm).
Installation: Leave a vertical space of about 7 cm under filter to allow replacement.
INSTALLING BATTERY
Slide off the cover case of the battery room, and put into 2AAA batteries.Then slide the cover case back.
SETTING CAPACITY
Press display button to choose the capacity. The sequence is 0-100-200-300...9800-9900-OFF. Then press
SET TIMING
Press Display button to choose the Timing. The sequence is 0-30-60-90...690-720-OFF. Then press reset
to save the Timing. The setting procedure is completed. *The capacity mode will be disabled when you
choose OFF. **The setting procedure will be terminated, and go back to the original status if there is no
input for 10 seconds.
OPERATING
The DigiFlow 8000T will be automatically on when there is any water flowing through the sensor. It will be
automatically off wen there is no water flowing for 10 seconds.
DISPLAY BUTTON:
Press display button is to display the status of the three modes of the DigiFlow 8000T. Capacity mode:
showing the capacity left. Timing mode; showing the timing left. Flow rate mode: showing the current flow
rate. The sequence is Flow-rate - Timing Capacity...
RESET BUTTON:
Press reset button is to reset the setting to be the last setting.
Warning Alarm
When Capacity reaches 0 gallon or Timing reaches 0 day, the buzzer will beep twice and the digit will flash
to notice you to change the filter cartridge when there is any water flowing through Digiflow 8000T or press
the display button.
Variants
Code Description
04606201-03 Ionicore I4 replacement filter 15.000lt. - 1,9lt./min. 0,5 micron (6)
Features:
- Chlorine reduction
- Reduction of cysts
- Reduction of particulate in suspension
- Activation: it is advisable to run water through filter at maximum pressure and full flow rate, for at least 5
minutes to allow air purging and flushing of cartridge.
- Cartridge change: When capacity is reached, or when flow comes too slow (precipitates under
0.7bar/10psi), every 6 months but at least annually.
Do not use with microbiologically unsafe or unknown quality water without disinfecting first. Cysts reduction
certified systems can be used with disinfected water that may contain filterable cysts.
All systems must be mantained according to the producer instructions.
Nota bene: The removed or reduced contaminants agents may not necessarily be in your water.
Code: 04606202
Ionicore I+ Plus antibacterial series water filters 0,2 micron (6)
Variants
Code Description
04606202-03 Ionicore I4+ antibacterial replacement filter 15.000lt. - 1,9lt./min. 0,2 micron (6)
Features:
- Chlorine reduction
- Antibacterial
- Reduction of cysts
- Reduction of particulate in suspension
- Activation: it is advisable to run water through filter at maximum pressure and full flow rate, for at least 5
minutes to allow air purging and flushing of cartridge.
- Cartridge change: When capacity is reached, or when flow comes too slow (precipitates under
0.7bar/10psi), every 6 months but at least annually.
Do not use with microbiologically unsafe or unknown quality water without disinfecting first. Cysts reduction
certified systems can be used with disinfected water that may contain filterable cysts.
All systems must be mantained according to the producer instructions.
Nota bene: The removed or reduced contaminants agents may not necessarily be in your water.