You are on page 1of 6
DisTRIBUTED BY ANAKO PHILIPPINES CORPORATION Page 1 of 6 MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT ‘SPRINKLER VK302 (K5.6) ‘The Viking Corporation, 210 N Industrial Park Drive, Hastings Mi 49058, ‘Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsves@vikingcorp.com ‘Visit the Viking website forthe latest edition of this technical data page: www.vikinggroupine.com 4. DESCRIPTION ‘The Viking Microfast® Quick Response Pendent Sprinkler VK302 is @ smal thermosensitve glass bulb spray sprinkler available wth various finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless [Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addtion, these coatings have been investigated for installation in Corrosive environments and are Listed and Approved as indicated inthe Approval Charts 2. LISTINGS AND APPROVALS (@x eULus Liste: Category iv FM Approved: Class Series 2000 Vas Approved: Certifeates 6414008, 6414010, 64040095, and 4880045 senior (=) LPCB Approved: Certiicate 0966/06 CE CE Certified: Standard EN 12250-1, cerificate of constancy of performance 0832:CPR-$0021 China Approval: Approved according o China GE standard @ MED Certified: Standard EN 12259-1, €C-certfcate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULuS Listing requirements, and ri F¥ Approval requirements that must be folowed, 3. TECHNICAL DATA ‘Specifications: [Minimum Operating Pressure: 7 ps (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostaticaly to 500 psi (34.5 bat) Thread size: 1/2" NPT, 15 mm BSP. Nominal K-Factor: 6.6 U.S. (80.6 metic™) Giass-bulb fluid temperature rated to -65 °F (55°C) Overall Lenath: 2-1/4" (68 mm) “eULus Listing, FM Approval. and NFPA 13 installs require @ minimum of 7 ps (5 bar). The minimum operating pressure for LPC and CE ‘Approval ONLY is 5p (0.35 ba), ‘Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bub: Glass, nominal 3 mm diameter Bllevile Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape ‘Screw: Brass UNS-C36000, Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainloss Steel UNS-$30400 For Polyester Coated Sprinklers: Bellevile Spring-Exposes For ENT Coated Sprinklers: Bolevile Spring-Exposed, Screw and Pipeap - ENT plated ‘Ordering Information: (Also refer tothe current Viking pricelist) (Order Quick Response Pendent Sprinklers by first adding the appropriate suffix forthe sprinkler fish and then the appropriate Sufi forthe temperature rating tothe sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = N/V, Black Polyester = MB, and ENT = JN Temperature Sufix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175°F (79 °C) = D, 200 °F (83 °C) = E, 286 °F (141 °C) =G. Form No, F_038314 19.11.14 Rev 193 Replaces Form No. F_033314 Rev 19.2 (Revised China Approval, eemoved 19780) 1 to Approval Chart 2 and Design Criteria for Eee a DISTRIBUTED BY ANAKO PHILIPPINES CORPORATION Page 2 of 6 MICROFAST® QUICK ae ee MUL RESPONSE PENDENT SPRINKLER VK302 (K5.6) ‘The Viking Corporation, 210 N Industrial Park Drive, Hastings Mi 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsves@vikingcorp.com Visit the Viking website for the latest edition ofthis technical data page: www vikinggroupine.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 “C) temperature rating = Part No. 12979AB, Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer tothe current Viking price list) Sprinkler Wrenches: ‘A. Standard Wrench: Part No. 21475M/B, 8. Wrench for Recessed Pendent Sprinklers: Part No. 1365SW/B™ (available since 2008) ©. Optional Protective Sprinkler Cap RemoverfEscutcheon installer Tool Part No, 15915 (available since 2010) "AY# rateet is required (not avaible om Viking) “Alows use fom the feor by aching a lenat ot 1 eareter CPV tubing othe too, eal for sprinkler cabinets. Refer to Bulletin F_051808, Sprinkler Cabinets: [A Sixchead capacity: Part No. 01724A (available since 1971) B, Twelve-head capacity: Part No, 01725A (available since 1971) 4. INSTALLATION Reter to appropriate NEPA Installation Standards 5. OPERATION DDuting fre conditions, the heat-sensive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattem to extinguish or control the fire 6. INSPECTIONS, TESTS AND MAINTENANCE. Refer to NFPA 25 for Inspection, Testing and Maintenance requirements 7. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is avaiable through a netwerk of domestic and international dis- trbutors. See The Viking Corporation web site for the closest distibutor or contact The Viking Corporation 8. GUARANTEE For details of warranty, refer to Viking’s curent lst pre schedule or contact Viking directly Wrench Fiat Protective Sprinkler Cap: Figure 4 ‘Standerd Sprinkler Wrench 214758 FormNo.F_093314 19.11.14 Rev 193 ing in Quality! DISTRIBUTED BY ANAKO PHILIPPINES CORPORATION Page 3 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Emall: techeves@vikingcorp.com Visit the Viking website for the latest edition ofthis technical data page: www.vikinggroupine.com Poets tenet en a een Ordinary 135 °F (57 °O) 100 °F (98 °C) ‘Orange Ordinary 155-°F (68°C) 400 °F (38°C) Rod Iniermediate 175 °F (79°0) 160 *F (65°C) Yattow Intermediate 200 °F (83°C) 150 °F (65°C) Green High 206 °F (141°C) 225 °F (107°C) Bue ‘Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings’: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (67 °C) Footnotes ‘The sprnker temperature rating i stamped on the deiectr. + Based on NFPA-13. Other Emis may appl, depending on fre lading, sprnkar ection, and ether requirements of he Authority Having Juridion Refer to specication standards, ° The carsion-esstant coatings have passed the standard corosion test requied by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent al possible coresive envierments. Paro installation, very through the end-user thatthe coatings are com pabble with or sutable forthe proposed enronment. For automate spenkers, the coatngs inccated are applied tothe exposed exterar surfaces ‘nly, Note thatthe spring fs exposed on sprinklers wih Polyester and ENT coatings. For ENT coated automatic spines, the waterway is coated Sprinkler wrench 1365SWIB"* for recessed pendent ‘sprinklers. ia A412" ratchet is required (not available from Viking) < Carefully slide the wrench sideways around the protective cap, ensuring engagement with cree the sprinkler wrench flats Figure 2: Wrench 13655WIB for Recessed Pendent Sprinklers Form No.F_033314 19.11.14 Rev 19.3, (2) 2 ANAK (2255) 2) Leading in Quality! DISTRIBUTED BY ANAKO PHIL! INES CORPORATION Page 4 of 6 ia MICROFAST® QUICK 4 Bisel Der Va ULY RESPONSE PENDENT SPRINKLER VK302 (K5.6) ‘The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058, ‘Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsves@vikingcorp.com ‘Visit the Viking website for the latest edition ofthis technical data page: www.vikinggroupine.com Listings and Approvals ‘pat | sm [rinkter {Rete seo Dest teria) oe at uw | vas | v7c8 . + | china : CE | ©" | approval os 23 02028 | kS02 | Pendent 56] coe | 206 | 58 Jarz.erozcx] - | 7 8021 | VK902 | Pendent 56 | eos |206| ss] amery | A [Aew|omciv| pr = ‘Approved Temperature ‘Approved Finishes ‘Approved Escutcheons la- 138° (oro) tes 68 rane Crvome, Whie |x. Standard suace mounted exctches othe Poyestor Black Pays: |VkingNhrmotc®Madel £1 Recessed Esetcheon B~136°F (57°C), 188 F 68°C) 175°F lier "Standard surfaea-mountosexctcheon oraceated wth the Viking Meromatc® (73°C). ane 200" (63°) Beenr Model 116.3 or 9 Recessed Exetceon Jo-188"F (68°C). 175°F 79°0),and|3-Crrome 2 Sanaa aatoce mounted eaushoo 200" 13°C) D158 F 68 0), 175 °F (79 °0),200°F (a0), 260° (44°C) Footnotes "Base part number shown, For carpet part ruber refer lo Viking’ utent pie schedule + Matie Kfar mesturerent shown when pressure la measured in Bar. When pressure measured in KP, divide the met Kato shown by 109. 2 This tale shows tha Istngs and apcoaleaalaseat the te of pring. ter approvals maybe In process. * Untd by Undrtrs Laboratori Ine fous inthe US, and Canada * cle ited a coroeonresitant * Other elore ae avalible cn eget wth he same sings and Approval asthe andar colors, * GE Cone, Standard EN 1259-1, EC-erfeatoof constancy of pertarmancs 0292.CPR-S0021, * MED Corie, Stansard EN 122691, €0-0892 MED-1009 + Agproved acoring to China G8 Standard sULus Listing Requirements: ‘The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULUS Listed as indicated in the Approval Chart for instalation in ‘accordance withthe latest ection of NFPA 13 for standard spray sprinklers, + Designed for use in Light and Ordinary occupancies. + The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be fllowed IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and, ‘also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No, F_033314 19.11.14 Rev 193, cs a2 0 O54 wo) 20 83 a esa ann acy ce Leading Quality! DisTRIBUTED BY ANAKO PHILIPPINES CORPORATION Page 5 of 6 MICROFAST® QUICK RESPONSE PENDENT ‘SPRINKLER VK302 (K5.6) Bie er Va ing Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Emall: techsves@vikingcorp.com Visit the Viking website forthe latest edition ofthis technical data page: www.vikinggroupine.com ‘Base Part Thread Size | Nominal KFactor | Overall Length FM Approvals? Number | 8 ae [om inches | mm | _ (Refer also to Design Criteria) "79 | vse isem | 56 Riz, BIY. 02K, C2 2ra6e | vKa02, 15mm | 66 3 (056528 VKs02 12 | 15mm | 56 [AIZ, BLY, D2X, C2 e021 | vKa02 12 | 15mm | 56 iz. BIY. “Approved Temperature Ratings: dj esuchecas JA 195 °F (7 °C), 155°F (68°C), 175 F (79°C), 200°F (63°C), 286 °F (141°C) 8-135 F (57 °C), 195 °F (68 ©), 175 °F 79 °C), and 20°F 83 °C) Jo 155 °F (8 °C) 175 °F 79°C), 200 *F (93 °C), 286: F(iatc) D- 155° (68°C), 175°F 79°C), 200°F (03°C) ‘Approved Finishes 4 -Brass, Crome, Wine Polyester ‘and Black Polyester 2.ENT 3: Chrome X ~ Standard strface-mounted escutcheon of the’ \Vikng Micromatc® ModelE-1 Recessed Escutcheon 'y-Standaré eurace-mounted eecutcheon or recesses vith the Viking Mleromatie™ Model E-1 or E-2 Recessed Escutcheon 2- Standard surface-mounted escutcheon Footnotes "Base part number shown. For complete part number, refer o Vikings current price schedule * Mette K:fctor measucement shou is when pressure is messure in Br, When presse is measured in KPa, de the mec Kfactor shoum by 400 2 This table shows the FM Approvals avaliable athe time of printing. Other approvals may bein process. + Other colors are avaiable on request withthe same Approvals 2s the standard colors. = FM approved as corrosion resistant. {Approved according to China GB Standard ‘The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers 2s indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss, Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to; minimum water supply requirements, hydraulic design, celing slope and obstructions, minimum and maximum allowable spacing, and defector distance below the celing NOTE: The FM installation guidelines may difler from cULus andlor NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VAS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable, Form No. F_083314 19.11.14 Rev 193 eh) es 6) 27 804 | (2) 90985, ‘6 SAMAK zs) |: (29 80 tice anaxephitippines com Leading in Quality! DistRigureD BY ANAKO PHILIPPINES CORPORATION Page 6 of 6 © MICROFAST® QUICK 4 TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) ‘The Viking Corporation, 210 N Industrial Park Drive, Hastings Mi 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupine.com Ceiling Opening Size: 2.5116" (59 mm) minimum iad 2-112" (64:mm) maximum (15mm) NPT, 28" 0 134" (57 mr i P (45 mm) Installed with a standard “18” surface-mounted fescutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Ceiling Opening Size: 2.5116" (59 mm) minimum 2412" (64 mm) maximum Installed with a Installed with a Model Model E-1 Recessed £2 Thread-on Recessed Escutcheon Escutcheon 18 with the Model E-1 and E-2 Recessed Escutcheons Figure 4: Sprinkler Dimer FormNo. F_033314 19.11.14 Rev 193 places Form No. F_033314 Rev 18.2 (Revised China Approval, removed 19780) ding in Quality!

You might also like