You are on page 1of 6

TECHNOLOGICAL INSTITUTE OF THE PHILIPPINES

938 Aurora Boulevard, Cubao, Quezon City

CE 509

COLLEGE OF ENGINEERING AND ARCHITECTURE


Civil Engineering Department

CE509

CE Projects Design 2

DESIGN OF TWO-STOREY DRUG REHABILITATION CENTER IN BARANGAY. 175 CALOOCAN,


QUEZON CITY

SUBMITTED BY:

GROUP 15

LEADER:
LATORENO, JOSH KIRBY

MEMBERS:
HABITAN, JERICO O.
PADILLA, ALEXEJOY JAMES
VILLANUEVA, JEREMIAH

CE52S2

SUBMITTED TO:
ENGR. JENNIFER CAMINO
INSTRUCTOR
4.3.4.1 Ground Improvement Using Wet Soil Mixing
4.3.4.2 Design Process

START

Determine Settlement of
Structure

Design of Wet Soil Mixing

Factor Safety > 4

Computed
NO
Settlement <
Actual
Settlement

Scheduling

Estimation

End
4.3.4.3 Ground Improvement Using Wet Soil Mixing Using Lime

Table : Column Properties – Wet Soil Mixing

WET SOIL COLUMN DATA

wet soil column diameter D 0.60 m

horizontal spacing Lx 0.70 m

vertical spacing Ly 0.60 m

length of column L 0.30 m

wet soil column strength target Pult 971.00 kN/m2

wet soil column shear strength fJG 57.01 kN/m2

wet soil unit weight γJG 13.61 kN/m2

Table: Soil Data for Wet Soil Mixing

SOIL DATA

natural ground allowable stress σs 240.00 kN/m2

bearing capacity of ground σsb 240.00 kN/m2

soil unit weight γs 19.34 kN/m2

safety factor FS 3.00

poisson's ratio ν 0.41

cohesion C 20.00 kN/m2

adhesion cu 0.97

angle of internal friction φ 23.00

Table: Liquefaction Data for Wet Soil Mixing


LIQUEFACTION DATA

SPT N-Values N 23.00

Layer Thick H 10.00 m

Correction Factor due to Surface FS 1.09

Vertical Stress σv 40.46 kN/m2

Effective Vertical Stress σ'v 28.7 kN/m2

ground acceleration amax 0.40 m/s2

4.3.4.4 Design Results of Wet Soil Mixing


Table: Data Output of Wet Soil Mixing

SOIL STRESS

σsb 240.00 kN/m σsb > σjs

σjs 244.04 kN/m Ok

LOADINGS

Pv 103.65 kN Pv < Q

Q 122.73 kN Ok

SLIP SAFETY

Vcol 0.81 kN Vcol < Vult

Vult 64.04 kN Ok

4.3.4.5 Design Results of Wet Soil Mixing


Table: Final Settlement of Wet Soil Mixing

WET SOIL MIXING FINAL SETTLEMENT

Qwp 99.07 Qwp 99.07 Qws 23.66

Qws 23.66 Iwp 0.85 p 1.884

ᶓ 0.67 D 0.6 D 0.6

L 0.3 qwp 350.5662 Iws 2.247487

Ap 0.2826 Poisson's 0.41 Poisson's 0.41

Ep 14739.09 Es 14739.09 L 0.3

Se1 0.008277179 Se2 0.010091 Se3 0.003186

TOTAL SETTLEMENT 21.55444435 mm

Table:Final Design of Wet Soil Mixing per Footing


WET SOIL DESIGN
Wet soil column diameter 0.60 m
horizontal spacing 0.70 m
vertical spacing 0.60 m

length of column 0.3 m


Number of Wet Soil per Footing 9.00 pcs
Number of Columns 486 pcs

The resulted economic sections for the design of ground improvement using Wet Soil Mixing as shown in
Table having a diameter of 0.6 m, horizontally spaced at 0.70 m and vertically spaced at 0.60 m
respectively. The Length of the columns is 0.3 m.
The designers use a typical footing in order to design the stone columns. The total number of stone
columns used was the number of columns used multiplied to the number of footing of the structure.
Figure: Layout Plan – Wet Soil Mixing