You are on page 1of 3

Roof slab at Distribution Channel

Geometry of roof Slab at room is shown below:


S.S.L = +6.1 m

250 THK

The loading in the model is established according


to the submitted loading plans

Loading Assumption (SDL)

Loading Assumption (NRLL)


Roof slab at Distribution Channel

Maximum Long Term Deflection from SAFE = 2 mm


Allowable Long Term Deflection = 7150 / 240 = 30 mm
Therefore OK

Slab Moment at X-Direction (ENV ULS)

Slab Moment at Y-Direction (ENV ULS)


Roof slab at Distribution Channel

Bottom Reinforcement X/Y Dir.


Mesh Size = T12-150 = 754 mm2/m
No Additional Rebar is shown below
Therefore OK

Bottom Reinforcement at X & Y-Direction

Top Reinforcement X/Y Dir.


Mesh Size = T12-150 = 754 mm2/m
No Additional Rebar is shown below
Therefore OK

Top Reinforcement at X & Y-Direction