You are on page 1of 66

Product Submittal

MasterSeal® 730 UVS


Preapplied below grade HDPE membrane with UV resistance
Index

1. Technical datasheet

2. MSDS

3. Job References

4. Method statement

5. Application Check list

6. Test reports
Technical Data Sheet
MasterSeal® 730 UVS
Pre-Applied Fully Bonded HDPE Waterproofing Membrane for below grade waterproofing

DESCRIPTION
Peel Adhesion to Concrete (N/mm) 1.8
MasterSeal 730 UVS is an HDPE membrane with Peel Adhesion, heat aged Surface
unique pressure sensitive adhesive and a state of 1.5
(50℃) (N/mm)
the arts top film which enable good chemical
adhesion with concrete surface. ASTM D 903 modified
MasterSeal 730 UVS forms a unique integral seal Nail Shank Resistant (N) 500
around the concrete poured against it, prevents EN12310-1
water ingress even under high hydrostatic pressure Tensile retention upon heat aging (%), 90
and prevents lateral water migration as well.
ASTM D 412
MasterSeal 730 UVS remains fully adhered to
concrete (i.e. monolithic) helping retain its Elongation retention upon heat aging 80
(%), ASTM D 412
performance even when there is ground settlement
beneath the slabs Resistance to Hydrostatic Head (m) 71
RECOMMENDED USES ASTM D 5385 modified
MasterSeal 730 UVS is intended for use in below Lateral water migration resistance (m),
grade waterproofing applications such as 23℃, ASTM D 5385 modified 71
basements rafts and confined retaining walls with
Lap Peel Adhesion, (N/mm,23℃) 1.0
high water table and cut & cover structures (e.g.
tunnels) and allows efficient use of confined Lap Peel Adhesion, after immersing in
sections. 1.0
water(N/mm,23℃)
FEATURES AND BENEFITS ASTM D1876 modified
• Fully Adhered to Poured Concrete – Dimensional Stability SS 374-1994 ≤ 0.5
Prevents later water migration between
concrete and membrane Tape
• Unaffected by hydrostatic pressure – Can Lap peel to HDPE sheet (N/mm, 23℃) ≥ 1.0
be used in high water table areas
Lap peel to HDPE sheet (N/mm,4 ℃) ≥ 1.0
• Unaffected by Contamination – Does not
require any special protection during The performance data is typical and based upon
construction – can be easily cleaned with water controlled laboratory conditions. Actual performance
and high-pressure air on the job site may vary from these values based on
actual site conditions
• Simple and Easy to Install – Does not require
special tools and welding techniques
• Chemically resistant – Can be used in all soil PROPERTIES
and sub-soil conditions, even if contaminated
with salts. MasterSeal 730 UVS (acrylic finished)
• Fully adhered watertight laps – Ensures Release (removal) liner is silicone based with
water tightness. better UV stability before removing liner

PERFORMANCE DATA Thickness* Width 1.2 mm *1.0 m


Color White
Elongation (%) ASTM D 412 500 1
MasterSeal 936 UVS
Tensile Strength (MPa) ASTM D 412 25.0 Thickness* Width 0.8mm*80 mm
Puncture Resistance(N) ASTM E 154 1000 2
modified MasterSeal 937 UVS
Low Temperature Flexibility, -25℃ Pass Thickness* Width 0.8mm*120 mm
ASTM D 1970
MasterSeal® 730 UVS
1. MasterSeal 936 UVS is a double side sticky
tape used for specialized detailing and Pouring of Concrete
overlaps.
Kindly ensure that the plastic liner of the membrane
2. MasterSeal 937 UVS is a single side sticky is removed prior to placement of reinforcement.
tape used for repair and termination of
It is recommended that concrete is poured within 5
membrane.
weeks after the HDPE membrane has been laid
APPLICATION on the sub-base (e.g. PCC). Care should be taken
Surface Preparation to avoid any damage to the membrane during
laying steel reinforcement, consolidation and
It is essential to create a sound and solid substrate compaction of concrete.
to eliminate movement during the concrete pour.
Substrates must be regular and smooth with no Additionally, during placement of concrete, the
gaps or voids. Grout around all penetrations for vibrator needle should not touch the placed HDPE
stability membrane. For best results use BASF’s Smart
Dynamic Concrete
Horizontal Blinding – The blinding must be free of
loose aggregate, voids, surface irregularities and PACKAGING
sharp protrusions. The surface needs to be in a MasterSeal 730 UVS is supplied in Rolls of 20 m
touch dry condition. SSD condition (no standing length and width of 1.0 m. Each Roll consists of
water) is also acceptable 20 Sq. of membrane
Vertical Surfaces – The vertical surfaces should MasterSeal 936UVS is supplied in rolls of 20 m
have proper levelled brickwork, blockwork or length and 80 mm width.
formwork without any irregularities. For the case of
MasterSeal 937UVS is supplied in rolls of 20 m
sheet piles, the substrate should be made regular
length and 120 mm width.
with a smooth finished shotcrete or sacrificial
formwork to be installed SHELF LIFE
Installation Twelve months if stored in original containers
Please contact our BASF representative for further under dry conditions at a temperature between 10-
support for detailed installation guidelines 30°C.
Membrane Repair PRECAUTIOUS
Generally, the membrane is very tough, and the
For the full health and safety hazard information
execution should not encounter any repair. In the
and how to safely handle and use this product,
most extreme cases, if for some site issues, there
please make sure that you obtain a copy of the
is any reason to do a patch work, then please
BASF Material Safety Data Sheet (MSDS) from
contact our BASF representative for the rectification
our office or our website.
procedure.

® = registered trademark of BASF group in many countries MAP#MasterSeal P 730 UVS v2. 01/20

The technical information and application advice given in this BASF Construction Chemicals publication are based
STATEMENT OF on the present state of our best scientific and practical knowledge. As the information herein is of a general nature,
RESPONSIBILITY no assumption can be made as to a product's suitability for a particular use or application and no warranty as to
its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The
user is responsible for checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF Construction Chemicals, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals Asia Pacific


33 Tuas Avenue 11
Singapore 639090

Tel: +65 68616766

Website: www.master-builders-solutions.asiapacific.basf.com
MSDS
Safety data sheet

Page: 1/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019

1. Identification
Product identifier

MasterSeal 730UVS
Details of the supplier of the safety data sheet

Company:
BASF SE
67056 Ludwigshafen
GERMANY

Telephone: +49 621 60-0

Emergency telephone number

International emergency number:


Telephone: +49 180 2273-112

2. Hazards Identification

Classification of the substance or mixture

According to UN GHS criteria

No need for classification according to GHS criteria for this product.

Label elements

Globally Harmonized System (GHS)

The product does not require a hazard warning label in accordance with GHS criteria.

Other hazards
Page: 2/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019

According to UN GHS criteria

If applicable information is provided in this section on other hazards which do not result in
classification but which may contribute to the overall hazards of the substance or mixture.

3. Composition/Information on Ingredients
Substances

Not applicable

Mixtures

Chemical nature

polyethylene (PE), coated

Hazardous ingredients (GHS)


According to UN GHS criteria

Paraffin oils
Content (W/W): >= 5 % - < 20 % Aquatic Chronic 4
CAS Number: 8012-95-1 H413
EC-Number: 232-384-2

For the classifications not written out in full in this section the full text can be found in section 16.

4. First-Aid Measures
Description of first aid measures
First aid personnel should pay attention to their own safety. Immediately remove contaminated
clothing.

If inhaled:
Keep patient calm, remove to fresh air. If symptoms persist, seek medical advice.

On skin contact:
After contact with skin, wash immediately with plenty of water and soap. Under no circumstances
should organic solvent be used. If irritation develops, seek medical attention.

On contact with eyes:


Wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an
eye specialist.

On ingestion:
Page: 3/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention. Do not induce
vomiting unless told to by a poison control center or doctor.

Most important symptoms and effects, both acute and delayed


Symptoms: The most important known symptoms and effects are described in the labelling (see
section 2) and/or in section 11.

Indication of any immediate medical attention and special treatment needed


Treatment: Treat according to symptoms (decontamination, vital functions), no known specific
antidote.

5. Fire-Fighting Measures
Extinguishing media
Suitable extinguishing media:
foam, water spray, dry powder, carbon dioxide

Unsuitable extinguishing media for safety reasons:


water jet

Special hazards arising from the substance or mixture


Carbon dioxide, Carbon monoxide, harmful vapours, nitrogen oxides, fumes/smoke, carbon black

Advice for fire-fighters


Special protective equipment:
Wear a self-contained breathing apparatus.

Further information:
The degree of risk is governed by the burning substance and the fire conditions. If exposed to fire,
keep containers cool by spraying with water. Collect contaminated extinguishing water separately, do
not allow to reach sewage or effluent systems. Contaminated extinguishing water must be disposed
of in accordance with official regulations.

6. Accidental Release Measures


Personal precautions, protective equipment and emergency procedures
Avoid breathing dust/fume/gas/mist/vapours/spray. Wear eye/face protection. Use personal
protective clothing. Handle in accordance with good building materials hygiene and safety practice.

Environmental precautions
Contain contaminated water/firefighting water. Do not discharge into drains/surface
waters/groundwater.

Methods and material for containment and cleaning up


For small amounts: Pick up with suitable appliance and dispose of. Dispose of absorbed material in
accordance with regulations.
Page: 4/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
For large amounts: Pick up with suitable appliance and dispose of. Dispose of absorbed material in
accordance with regulations.

7. Handling and Storage


Precautions for safe handling
Avoid inhalation of dusts/mists/vapours. Avoid skin contact. Ensure adequate ventilation. No special
measures necessary provided product is used correctly.

Protection against fire and explosion:


The product is neither self-ignitable, nor an explosion hazard, nor does it promote fires.

Conditions for safe storage, including any incompatibilities


Further information on storage conditions: Keep only in the original container in a cool, dry, well-
ventilated place away from ignition sources, heat or flame. Protect from direct sunlight.

Specific end use(s)


For the relevant identified use(s) listed in Section 1 the advice mentioned in this section 7 is to be
observed.

8. Exposure Controls/Personal Protection


Control parameters

Components with occupational exposure limits

6683-19-8: Pentaerythritol tetrakis(3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate)


8012-95-1: Paraffin oils
9002-88-4: polyethylene

Exposure controls
Personal protective equipment
Respiratory protection:
Wear respiratory protection if ventilation is inadequate. Combination filter for gases/vapours of
organic, inorganic, acid inorganic and alkaline compounds (e.g. EN 14387 Type ABEK).

Hand protection:
impermeable gloves
Synthetic rubber gloves
Manufacturer's directions for use should be observed because of great diversity of types.

Eye protection:
Safety glasses with side-shields (frame goggles) (e.g. EN 166)

Body protection:
Body protection must be chosen based on level of activity and exposure.
Page: 5/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019

General safety and hygiene measures


Do not inhale dust/fumes/aerosols. Avoid contact with the skin, eyes and clothing. Avoid exposure -
obtain special instructions before use. Handle in accordance with good building materials hygiene
and safety practice. Wearing of closed work clothing is recommended. When using, do not eat, drink
or smoke. Hands and/or face should be washed before breaks and at the end of the shift. At the end
of the shift the skin should be cleaned and skin-care agents applied. Gloves must be inspected
regularly and prior to each use. Replace if necessary (e.g. pinhole leaks). When using do not eat or
drink.

9. Physical and Chemical Properties


Information on basic physical and chemical properties

Form: film
Colour: yellowish to white
Odour: odourless
Odour threshold:
No applicable information available.
Flash point:
not applicable, the product is a solid
Flammability: not highly flammable
Relative density: 0,97
Solubility in water: not soluble
Partitioning coefficient n-octanol/water (log Kow):
not applicable for mixtures
Thermal decomposition: No decomposition if stored and handled as prescribed/indicated.
Explosion hazard: not explosive

Other information

Other Information:
If necessary, information on other physical and chemical parameters is indicated in this section.

10. Stability and Reactivity


Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.

Chemical stability
The product is stable if stored and handled as prescribed/indicated.

Possibility of hazardous reactions


The product is stable if stored and handled as prescribed/indicated.

Conditions to avoid
Avoid heating.
Page: 6/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019

Incompatible materials

Substances to avoid:
strong oxidizing agents, alkalies

Hazardous decomposition products

Hazardous decomposition products:


No hazardous decomposition products if stored and handled as prescribed/indicated.

11. Toxicological Information


Information on toxicological effects

Acute toxicity

Assessment of acute toxicity:


Virtually nontoxic after a single ingestion. Virtually nontoxic by inhalation. Virtually nontoxic after a
single skin contact. Based on available Data, the classification criteria are not met.

Irritation

Assessment of irritating effects:


No irritation is expected under intended use and appropriate handling. Based on available Data, the
classification criteria are not met.

Respiratory/Skin sensitization

Assessment of sensitization:
Based on the ingredients, there is no suspicion of a skin-sensitizing potential. Based on available
Data, the classification criteria are not met.

Germ cell mutagenicity

Assessment of mutagenicity:
The chemical structure does not suggest a specific alert for such an effect. Based on available Data,
the classification criteria are not met.

Carcinogenicity

Assessment of carcinogenicity:
The chemical structure does not suggest a specific alert for such an effect. Based on available Data,
the classification criteria are not met.

Reproductive toxicity

Assessment of reproduction toxicity:


Page: 7/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
The chemical structure does not suggest a specific alert for such an effect. Based on available Data,
the classification criteria are not met.

Developmental toxicity

Assessment of teratogenicity:
The chemical structure does not suggest a specific alert for such an effect. Based on available Data,
the classification criteria are not met.

Specific target organ toxicity (single exposure)

Assessment of STOT single:


Based on available Data, the classification criteria are not met.

Repeated dose toxicity and Specific target organ toxicity (repeated exposure)

Assessment of repeated dose toxicity:


No reliable data was available concerning repeated dose toxicity. Based on available Data, the
classification criteria are not met.

Aspiration hazard

No aspiration hazard expected.

Other relevant toxicity information

Based on our experience and the information available, no adverse health effects are expected if
handled as recommended with suitable precautions for designated uses. The product has not been
tested. The statements on toxicology have been derived from the properties of the individual
components.

12. Ecological Information


Toxicity

Assessment of aquatic toxicity:


Based on available Data, the classification criteria are not met. There is a high probability that the
product is not acutely harmful to aquatic organisms.

Persistence and degradability

Assessment biodegradation and elimination (H2O):


Not readily biodegradable (by OECD criteria).

Bioaccumulative potential

Assessment bioaccumulation potential:


No data available.
Page: 8/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
Discharge into the environment must be avoided.

Mobility in soil

Assessment transport between environmental compartments:


Volatility: No data available.

Results of PBT and vPvB assessment

The product does not fulfill the criteria for PBT (Persistent/bioaccumulative/toxic) and vPvB (very
persistent/very bioaccumulative).

Other adverse effects

The product does not contain substances that are listed in Regulation (EC) 1005/2009 on
substances that deplete the ozone layer.

Additional information

Other ecotoxicological advice:


Do not discharge product into the environment without control. The product has not been tested. The
statements on ecotoxicology have been derived from the properties of the individual components.

13. Disposal Considerations

Waste treatment methods

Observe national and local legal requirements.


The waste code in accordance with the European waste catalog (EWC) must be specified in
cooperation with disposal agency/manufacturer/authorities.
Residues should be disposed of in the same manner as the substance/product.

Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for
recycling after being thoroughly cleaned.
Packs that cannot be cleaned should be disposed of in the same manner as the contents.

14. Transport Information

Land transport

ADR
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Page: 9/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user

RID
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user

Inland waterway transport


ADN
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user:

Transport in inland waterway vessel


Not evaluated

Sea transport

IMDG
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user

Air transport
Page: 10/10
BASF Safety data sheet according to UN GHS 4th rev.
Date / Revised: 27.06.2019 Version: 1.0
Product: MasterSeal 730UVS
(ID no. 961692/SDS_GEN_00/EN)
Date of print 10.07.2019
IATA/ICAO
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user

Transport in bulk according to Annex II of MARPOL and the IBC Code


Regulation: Not evaluated
Shipment approved: Not evaluated
Pollution name: Not evaluated
Pollution category: Not evaluated
Ship Type: Not evaluated

15. Regulatory Information


Safety, health and environmental regulations/legislation specific for the substance or
mixture

If other regulatory information applies that is not already provided elsewhere in this safety data
sheet, then it is described in this subsection.

16. Other Information

Full text of classifications, hazard symbols and hazard statements, if mentioned in section 2 or 3:
Aquatic Chronic Hazardous to the aquatic environment - chronic
H413 May cause long lasting harmful effects to aquatic life.

The data contained in this safety data sheet are based on our current knowledge and experience and
describe the product only with regard to safety requirements. This safety data sheet is neither a
Certificate of Analysis (CoA) nor technical data sheet and shall not be mistaken for a specification
agreement. Identified uses in this safety data sheet do neither represent an agreement on the
corresponding contractual quality of the substance/mixture nor a contractually designated use. It is the
responsibility of the recipient of the product to ensure any proprietary rights and existing laws and
legislation are observed.

Vertical lines in the left hand margin indicate an amendment from the previous version.
Job References
Product Project Contractor/Applicator Company/Place Type Depth of Basement Area Date
MasterSeal 730 PA
MasterSeal 936
MasterSeal 937
KVMRT II MGKT Malaysia Undergroud MRT station 4 68,000 sq.m. 2017
MasterSeal 909
MasterSeal 901
MasterSeal 910S
MasterSeal 730 PA
MasterSeal 936
MasterSeal 937 4 in 1 - Thomson-East Coast Line
GS&EC Singapore Largest MRT Depot in Asia Pacific 4 290,000 sq.m. 2017
MasterSeal 909 (T301)
MasterSeal 901
MasterSeal 910S
MasterSeal 730 PA
MasterSeal 936 Alila Dalit Bay -KK Vinci Construction Malaysia Hotel & Resort 3 12,000 sq.m. -
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 Reem Mall Itenera/Ghantoot JV UAE High End Mall 2 150,000 sq.m, 2018
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 World Trade Center-Chennai India Aquaseal (Applicator) India Mixed-Use 4 50,000 sq.m. -
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936
MasterSeal 937 MELBOURNE METRO - ARDEN
To be advised Australia Undergroud MRT Station 1 25,000 sq.m 2019
MasterSeal 909 STATION WEST
MasterSeal 901
MasterSeal 910S
MasterSeal 730 PA
MasterSeal 936
MasterSeal 937
Parkville To be advised Australia 1 36,000 sq.m 2019
MasterSeal 909
MasterSeal 901
MasterSeal 910S
MasterSeal 730 PA
MasterSeal 936 REEL MALL To be advised UAE National Real Estate 4 500,000 sq.m.
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 ADNOC - (Petroleum) Samsung Engineering UAE Refining & Crude Facility To be advised 20,000 sq.m. 2018
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 Borough - Polypropelene, 5project Technimont UAE Oil & Gas To be advised 35,000 sq.m. 2019
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 Khazzan Gas Project Samsung Engineering Oman Refining & Crude Facility To be advised on going 2019
MasterSeal 937
MasterSeal 730 PA
MasterSeal 936 Al Kifaf Project Ssyanyong Engineering & Construction UAE Mix Utility Buildings 3 18,000sq.m 2019
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936 PHOENIX EQUINOX, Hyderabad SVS India Mixed-Use 12 33,000 sq.m. On-going
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936 PHOENIX 285 D Shapoorij Pallonij India IT Park/IT-SEZ 15 41,000 sq.m. On-going
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936 KAR BHAWAN, GUWAHATI To be advised India Building To be advised 2,540 sq.m. 2019
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936 VTP LEONARA VTP Realty/Kavle Pressure Concrete (Applicatior) India Residential Building 12 1,000 sq.m. 7/1/2019
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936 INDUSTRIAL PROJECT Shapoorij Pallonij India Industrial Factory - 2,600 sq.m. 2019
MasterSeal 937
MasterSeal 730 UVS Secured,
MasterSeal 936 BAASHYAAM CROWN RESIDENCE Shapoorij Pallonij India Luxury Apartment To be advised 44,000 sq.m. waiting to start
MasterSeal 937 installation
MasterSeal 730 UVS
Shapoorji Guwahati Convention
MasterSeal 936 Shapoorij Pallonij India Convention Centre 2 18,000 sq.m. 2019
Centre Wolrd
MasterSeal 937
MasterSeal 730 UVS
MasterSeal 936
MU11- Empire - HCMC Central/VDT Viet Nam Residential Building 2 12,000 sq.m. 2020
MasterSeal 937
MasterSeal 910s
MasterSeal 730 UVS
MasterSeal 936
Vega City shophouse - Nha Trang Huyndai/CMT Viet Nam Mix Utility Buildings 1 40,000 sq.m. On-going
MasterSeal 937
MasterSeal 910s
MasterSeal 730 UVS
MasterSeal 936
MasterSeal 937 Wink Hotel - Tran Phu- Tran Hung Dao-
Kajima/HBC Viet Nam Hotel 1 4,000 sq.m On-going
MasterSeal 909 Da Nang
MasterSeal 901
MasterSeal 910S
Method statement
MS - CC - MasterSeal 730PA - 02/2018

GENERAL METHOD STATEMENT


MasterSeal 730 UVS

Page 1 of 7
MS - CC - MasterSeal 730 UVS - 06/2019

1 Scope

This document outlines the general method statement for the application and processing of pre-
applied, fully bonded, waterproofing membrane, MasterSeal 730 UVS, for below ground concrete
structures.

2 Materials

The table below describes the system built-up material from BASF Construction Chemicals and
shall be supplied by the applicator and must be in accordance with the material approvals

Item Description of Material

MasterSeal 730 UVS Pre-applied HDPE waterproofing membrane

MasterSeal Tape 1 Double sided sticky tape


MasterSeal Tape 2 Single sided sticky tape
MasterSeal HLM 5000 RG Single component PU coating
MasterSeal 914 Epoxy grout
MasterSeal 912 Swelling gasket in paste form

MasterFlow 810 High-strength micro concrete for pile head re-profiling

3. QUALIFICATIONS

• BASF - Supplier’s qualifications: The supplier of the specified products shall offer a program
for training, certifying, technically supporting and periodically re-certifying contractors Supplier’s
Site Representative should be capable of instructing successful methods for installation and also
capable of explaining, technical aspects of correct material selection, mixing, use and application.
• Applicator’s qualifications:
- The applicator shall be experienced with both material application and surface preparation
and shall supply all labour, materials, equipment and incidental equipment required to install
MasterSeal 730UVS system as specified in this method statement.
- Work shall only be executed by trained and qualified employees certified by the supplier

4. MasterSeal 730UVS System – GENERAL APPLICATION

4.1 Substrate Preparation

• Substrates must be regular and smooth, free of loose aggregate and sharp protrusions.
• All sharp corners / edges to be chamfered with minimum 30mm
• Surface should be sufficiently dry, standing water must be removed.
• Horizontal substrate requirement is a minimum of 100 mm blinding poured over
compacted ground or mass concrete layers.
• Vertical substrate should be either evenly smooth surface of shotcrete, reinforced concrete or
concrete blocks.
• Piles should be re-profiled with MasterFlow 810 with a bead of MasterSeal 912 around the
steel bar prior to grouting.

Page 2 of 7
MS - CC - MasterSeal 730 UVS - 06/2019

4.2 Membrane Installation

• Install the membrane with the adhesive


side facing the expected pouring of
concrete.

MasterSeal 730UVS, horizontal


application

• Overlap for succeeding membrane should


be at least 80mm. Membrane sheets are
normally pre-striped with an 80mm line on
one side for overlap. Overlaps without the
pre-striped line shall be adhered using
MasterSeal Tape 1.

MasterSeal 730UVS, overlapping

• Fold the membrane to overlap the vertical


applied membrane to the horizontally laid
membrane.

Fold membrane for vertical and horizontal


interface

Vertical and horizontal membrane overlap

Page 3 of 7
MS - CC - MasterSeal 730 UVS - 06/2019

• Corners shall be coated with


MasterSeal HLM 5000 R for sealing.
Once the coating is cured, cover the
coating with MasterSeal Tape 2 to
allow adhesion to concrete.

Coat the corner with MasterSeal HLM5000 R

• Overlaps on horizontal and vertical


interface shall be reinforced and sealed
with MasterSeal Tape 2 as shown.

Patch the corner overlaps with


MasterSeal Tape 2

Page 4 of 7
MS - CC - MasterSeal 730 UVS - 06/2019

4.4 Pipe Penetration

• Cut a hole on the membrane slightly


smaller than the pipe and insert the
pipe through and fit snugly to the
opening. Place MasterSeal Tape 2
around the base of the pipe to receive
the coating.

MasterSeal Tape 2 on the base of pipe

• Coat the pipe interface with


MasterSeal HLM 5000R having a
minimum height and span of
150mm. Apply MasterSeal Tape 2
over the cured coating to allow
adhesion to concrete.

Coating with MasterSeal HLM 5000 R

4.5 Pile Head Treatment

• Cut a hole on the membrane slightly


smaller than the pile. Insert the pile
through and fit snugly to the opening.
Coat the pile with MasterSeal HLM
5000R extending at least 150mm
from the base and 50mm
passing the reinforcements.
• Once the coating has cured,
encapsulate the pile with an epoxy
grout MasterSeal 914 with a minimum
thickness of 30mm over and around
the sides of pile.
Pile head through the membrane

Page 5 of 7
MS - CC - MasterSeal 730PA - 02/2018

Page 6 of 7
MS - CC - MasterSeal 730 UVS - 06/2019

5. Repair and Maintenance


• Damage can be repaired internally or externally by patching it with a piece of
MasterSeal 730 UVS, adhered using MasterSeal double sided tape and reinforced with
MasterSeal single sided tape on the sides.

6. Inspection and Quality Control


• Work shall be visually inspected for damages before and after installation of steel
reinforcements.

7. Material Storage
• Store materials under dry and shaded conditions. Do not expose to direct sunlight.

STATEMENT OF RESPONSIBILITY

The technical information and application advice given in this BASF publication are based on the present state of our best scientific and practical
knowledge. As the information herein is of a general nature, no assumption can be made as to a product's suitability for a particular use or
application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law.
The user is responsible for checking the suitability of products for their intended use.

NOTE

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or in writing may be
followed, modified or rejected by the owner, engineer or contractor since they, and not BASF, are responsible for carrying out procedures
appropriate to a specific application.

Page 7 of 7
Test reports
Ageing Report
Format No: SALLGN/TRF/GEN
Issue No:01, Issue Date: 01-04-2017
Page 1 of 3

CIN:U74220DL1998PLC092698 TEST REPORT


Test Report Issued To:
Test Report No: M190402009/M190402009-1
BASF INDIA LIMITED Date of Issue: 11-May-2019

BASF CONSTRUCTION TECHNOLOGY CENTRE,,


C-406/407, MIDC, THANE BELAPUR ROAD, , NAVI
MUMBAI, MAHARASHTRA, INDIA, 400613,
Sample Booking/Receipt Date: 02-Apr-2019
Date of Start of Testing: 05-Apr-2019
Date of Completion of Test: 11-May-2019

Customer Relationship Number M30243

Sample Description :
MASTERSEAL 730 UVS

Customer Reference No :

Kind Attention : MR.ANAND GHARAT

E-Mail: anand.gharat@basf.com Contact No: 9833273313

Sample Condition : NA

Sample Quantity (Approx) : NA Sample Size (Approx) : NA


SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

Digitally signed by
VISHWA
BANDHU GUPTA
Date: 2019.05.11
11:14:45 +05:30
Report Issued by

Authencity of report can be verified by mail at verification@spectrolab.in


This is a Digitally Signed Report and hence doesn't require Physical Signature.

Spectro Analytical Labs Limited S-1, GNEPIP, Surajpur Industrial Area,Phase-V, Kasna, Greater Noida-201308 (India)

Phone : +91-120-2341250,2341251 || URL : www.spectro.in || Email: care@spectro.in


BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory
Please refer to our Website http://www.spectro.in/spectro-policies.html for Terms & Condition
Format No: SALLGN/TRF/GEN
Issue No: 01, Issue Date: 01.04.17

CIN: U74220DL1998PLC092698
TEST REPORT Page 2 of 3
Report No. M190402009/M190402009-1

ID-M190402009-1 Date of start of test : 05/04/2019


Date of completion of test : 11/05/2019

S. No. Name of test Results Test Method

1. Tensile strength, N/mm2 ASTM D412 - 2016


(a) Longitudinal direction 28.8
(b) Transverse direction 27.7
2. Elongation at break,% ASTM D412 - 2016
(a) Longitudinal direction 612
(b) Transverse direction 656
3. Dimensional Stability, % Guidelines of customer
(At 80oC for 24 hours) specification and
(a) Longitudinal direction 0.39 ASTM D1204 - 2014
(b) Transverse direction 0.41
4. Lap Peel adhesion,N/mm 2.5 ASTM D1876-2001
(At 7 days)

5. Peel adhesion to concrete,N/mm 2.9 ASTM D903-1998


(At 7 days)

6. Puncture resistance,N 1099 ASTM E154 - 2008

7. Resistance to hydro-static head No Leakage ASTM D5385-2000


(a) Applied Pressure - 61 m or bursting observed

8. Lateral water migration Resistance No Leakage ASTM D5385-2000


(a) Applied Pressure - 71 m observed

9. Water vapour transmission,Perm 0.005 ASTM E96-2016


(a) Relative Humidity - 50%
(b) Temperature - 23oC

Digitally signed by
VISHWA
BANDHU GUPTA
Date: 2019.05.11
11:14:45 +05:30
Analyst Signature Authorised Signatory
Format No: SALLGN/TRF/GEN
Issue No: 01, Issue Date: 01.04.17

CIN: U74220DL1998PLC092698
TEST REPORT Page 3 of 3
Report No. M190402009/M190402009-1

ID-M190402009-1

S. No. Name of test Results Test Method

10. UV Exposure test No delamination, ASTM G154 - 2016


Type of Lamp - UVA340 No blistering,
Irradiance - 0.89W/m²/nm No peeling,
No chalking &
No cracking
Test Condition observed
8 Hours U.V. At 60±3 0C
4 Hours Condensation At 50±3 0C
This consists of one cycle
Total Exposure Time - 168 hours/ 7days

11. Tensile Retention Test DIN 16726-2011


1 Days at 23±2oC and 50±5% RH
+28 Days at 23±2oC in 10% NaCl solution
+7 Days at 23±2oC and 50±5% RH
(A) Tensile retention,% ASTM D412 - 2016
(a) Longitudinal direction 96.2
(b) Transverse direction 97.8

(B) Elongation at break retention,% ASTM D412 - 2016


(a) Longitudinal direction 94.1
(b) Transverse direction 92.1

-- End of Test Report --


Digitally signed by
VISHWA
BANDHU GUPTA
Date: 2019.05.11
11:14:45 +05:30
Analyst Signature Authorised Signatory