You are on page 1of 153
gale ag lysall aylagmasll yo rmall Reeergeyveveert\try Eng.ahmedessa2020@gmail.com 1 sake By UPS SS at Wake Poa ee eS Webs Taal Bl day lee he seks TS ip BEE aa Tats qe uke Sia ae a tie Thaw So Ea ssw 26 Gke cae 33 ke SARIS BH SS 39 tie Tana! Sa Se aise We Deeg AIAN Sly BS Satake DOL 69 Sad AAG ally sot NEC HS 2 SE aD ye peat ce Bm erie Cable Trunking Size 33Iy hs 70 iaie SI Be TFT as Tatas SE Teka NECHS & ad aa SS wie a ied GS ae ie capacitor Banks 5 92 taka HVAC Sash 4 LI 96 ke aS 99 the Tee be A La no Sie Caw eT os 3 Sie Beam Angel aies 250 Sis Tie tie Facade Lightingg 5G» Sie) ais nthe TET aad aa a a bie PV Systema a ct 70 Gis Fae Deel pa oe ee ually UPS class pana damitlly UPS spans alles — he AyRath Jean UPS Ban.y Aas cual DCS Cabinet =200VA Autonomy = 4H ESD Cabinet =200 VA Autonomy=4H Telecommunication Cabinet =150 VA Autonomy =6 H Computer Console= 90 VA Autonomy =2H oa Design Load “his «:¥43) Sd=SplL+ke)(1+Ke) Sd (Apparent power ) VA Kg(Future Load )=5 to 20% Ke(Design Margin)=10 to 15% Peak Load (Sp}=150+200+200+90=640 VA Design Load(Sd)=640(1+0.1)(1+0.1)= 744A Energy Demand ctw -: Wii Ed=Et(14K@)(1+Ke) Ed (Energy Demand )=Vah Gala Jan yo i 13 4€¢ (Total Load Energy]=Vah KglFuture Load %) Ke(Design contingency %) 81=150 x 6 +200 x 4+200 x 4490 x 2=2680 V ah Design Energy Demand= 2680(1+0.1)(1+0.1}=3242.3 V ah Sy ja ao N max=Vde(1+Vi max)/Ve N mine Véel2-Vi min)/V dch Vde=120 DC 4 tao) aad te Max Voltage tolerances =20% vias Min Voltage tolerances =10% u=.8s V e=Cell Charging Voltage =2.25 Vdc/Cell Vd ch= Cell discharging Voltage =1.8 Vde/Cell Fi tea J Gay ply Nomax=120(1+0.2)/2.25=64 Cell N min=120(1-0.2)/1.8+60 Cell gL al bl 9h C min: {ka x Kt x Ke)/Vde x K dod Comin 4 fal aad a jal a Ed el pen A5LI Ladl go Kai til alee suggest =25% KtSlual das cies suggest= at 30C =0.965 Koay Und Aen dates Suggest =10% K deat Hal & X98 ste! Jules from example =80% FALLD Ulead oc, C min=3242(1.25 x 1 x 0.965)/120 x 0.8=44.4 Ah As per design load=774.4 VA we will select UPS=1 KVA. Rectifier, Charge Chis «: basis Mead oo oad current =§/Vde = 1000/120=8.33 A Ic=Cxki/te Ic Max DC charger c= select battery capacity Ah we will select 50 Ki Battery charger eff=1.1 Te=min battery recharge time we will select for this ex=2 hours Ic=50x1.1/2=27.5 A Rectifier & Charger oS) Bas ¢ pal | I min DC=te+! Ide | min 0C= 27.5+8,33-35.8 A Rectifier =40 iam (5 1 Inverter & static Switeh hina «: Lathe Aa SL Gh a lh ot (e=S/1.732xV 1e=1000/1.732 x 240 =2.4 A Dial 5 CSGly Aaah Bl JER Uy elpall Be AB oa Lightning protection calculations Gel pall pole ls Saal Aen ha lag SI ASD Gas ny el pal ll he Sal Ge Nd,Noahias ty Neds il pa fl gl opal pn ae ye Ne: il yal So Gel pall lee Jbaly Gel mall cle 8.6 OS NBN 3 LABS! Gel mall gle ASS GS NdeNe oh cube Noche Ne=1.5 * 104-3 / M_ MzC2*C3*CA*C5 Silay Gh ose sinall Bale & 5) 8 9 C2: ply alae gy Leal y JAE Cis a nll Sh si gty C3: ay ala TL Ge sel DRA) a CA: dy alae BES a ae Gel pall Sleep ye Ay C5; A ile Ndchiua -2 Nd=Ng*Ae*C1*10"-6 Adana Sao Vy al ony EL Ny Sie Cm Ge ll Ja gh Cl Ay Dale Ce Noe eas oe Qe SL ll el pal nS ag Aba Ge Lele Jpmaly Ng=0.04*Td41.25 Ay Uys By Wiade SS LoL OD Gy Lee oan dis JIS el pall Sy pe Ugg ll ALY axe aT 10 cody tain a nf a Lede Spal rn an 1 Daal gy ea i ye DUALS aa Lae Collection Area (Ac}=(L x W) + 2 (Lx H) + 2(W x H) (3.14 x H2) oul J a el wae AW eae aH Je Sh pal sme Gas cg JS Hy Vl Gel en il itl a cling J +60 sd le 28 alae 23 cule) N= 80,00 Days/Yearésc_j) ale) sie 5 cbs Sysall on =Ng=69 km2/Years.8 Zu tits {Az building -housing «Au ¢8 al g (8) Steel framed encased without Metal Roof Degree of Isolation (D}= Structure in a large area having greater height Type of Country (E)= Flat country at any level =0.3 Maximum Acceptable Overall Risk Factor =0.00000001 dab sated he 35) Collection Area (Ach=(L x W) + 2 (Lx H) + 2(W x H) +(3.14 x H2) Collection Area (Ac) = (60x28}+2x(60x23)+2x(28%23}4{3.14x23x23) Collection Area (Ac) =7389 Meter? Probable No of Strikes to Building / Structure (P}= Ac x Ng x 10-6 No’s / Year (P)= 7389x69x10-6 = 05038 No’s/ Year 2 AIS Jan Ge ANBXOODXE Dialed G yay ph a As0.3 US Saat B-0.2 cet Just £03 a Jat D-0.4 gis Jat £:0.3 Any country (M) =0.3%0.2x0.3x0.4x0,3=0.00216 ia ese Overall Risk Factor Calculated (xc)= Mx P (xc}= 0.00216 x 0.05098=000110127 Base Area of Structure (Ab) = (LxW)=1680 Meter? Perimeter of Structure (P) =2x (L+W)= 2x(60+28)=176 Meter Fs hm ge ghing rt Gt Gel gia pine Jl gb gall J Jae a S15 Ja Jae p pape align ll a is 0.000110127 > 00000001 Gel pe cle clas aye Down Conductorse! pall 26 Glue =: Gil Down Conductors As per Base Area of Structure (s) =1+(Ab-100)/300 (s) =14(1680-100)/300=6 No’s Down Conductors As per Perimeter of Structure (t)= P/30 (t)= 176/30=6 No's ‘Minimum No of Down Conductor is 6 No’s Factores / wonanops Lazorstons Sas) Sos 10 me AD doten eee a ae Degree of Isolation Factor ‘Structure in a large area having greater height ‘Structure located in a area of the same height Structure completely Isolated 2 Gl dae 10 es 25) Jose) 1 1S 3043 (He Syne Gia ua ge dal ci 2 1S 3043 gb Jp ay Jeage Hate ta A= (Ifevt) /K t= Fault current Time (Second), 1 sec or 3 sec ca Jilsak = Material Constant For GI=80 For copper K=206 For Aluminum K=126 2,5 hal Jal 8 sp pl ony 98433. SE) LI ee 51 OH Gd eal ld AS 1600 a Ja Strip Size Conductor Hs! J 256% 5 oa AIA a bo lo A= (ev) /K Se cust be Ys) 1=1600/1.732*433=2133 A 1se=2133/0,06=35560 A Aa Leen es aa 1 ee A=35560xv1/206=172 mm CE Sane hey aso A=172x1.5=258 mm Recommend Strip Size = 40x6 mm AaB Chall CAS AY pal gt) gunn Glen JS HL yl Gi a 3B 433 435, 30 T0877 FE 3 2 5 Shon Crewe Curent (Sc)mA } 18001 6 arr | 35558 "area of Protective conductor = inveqimem = SC "Whe = 208, or 73st | 17545 Zea Recommended stip se | 75x mm mm] ax6mm | x6 mm ‘Aluminium k= 126 ‘aad ‘20.47 | 2422 35275 Recommended sip 28 [75.8 me xem] sOxemm | —Toxemm Steel, k= 80 210001 as_| ozs | aasar 555.59 Fiscommences sp sae | x6 Dx 5x6 mm | Te x6mm| 75 x6mm | Te x10 mm k= 208, Taize_| wea | zone _|_2ase8 | 70806, war Recommended sinp se | 25x6rm| xem] Wx0mn| axomn| Sxemm | —Tox6 mm ‘Aluminium = 126 zao0s | 27404 | seca | see | «0070 ‘10.97 Recommences sup sz@__| 40 x6 mm Soxsmw | 75x6mm| 75x6mm| 76x mm | 7ex 10mm ‘Steel k= 80 aera | as303 | s77a7_| e012 | 7e002, 962.28 ‘Pare A: Typical Protective conductor size required for Transformer Ratings (100-S00KVA) “Short Giveut Current (SC) nA oT SeCEStoonmeedance ie crown — SCs oS da AS ys ye QRS cay ale spall ally Jyall ape Glee, Plsh AS 0.80/11 o> seal Gish 51S 1000 Anu gael pal sb dad cua! Impedance=5.75% PF=0.8 EF=0.99 Code D motor start 2 times 9 460 Cisilly Chae 400 tine Samy Anas ay per hour 9610 (A sg Sil da gael) Gua ol FL 1 Motor Full Load Current (FLC (HPx746)/(1.732x Volt (L-L)x PF x ef) FLC=400%746/1.732 x 460 x 0.8x0.99= 472 Amp. NEC 430-2505 cH See FLC for 400 HP = 477 AMP URC ans 9s oy Motor (LR ‘Multiplier x Motor Full Load Current 2b Socal om Min Motor (LRC) (L1}=4.10*477=1955 Amp Max Motor (LRC)(L2) =4.50*477=2146 Amp NEC 430-251-BS sie G4 Jobe See 3) ‘Motor inrush Kva at Starting Irsrm)=Volt x locked Rotor Multiplier x Full Load Currentxl.732 / 1000 (lesm)=460 x 4.5x477x1.732 / 10001710 KVA as) ca SYS 1000 Jal Sila Guan Transformer (FLC)= Kva/(1.732xVolt) Transformer (FLC)=1000/(1.732%480}=1203 Amp. (isc) =Transformer Full Load Current / Impedance. {\sc]= 1203/(5.75/100}= 20919 Amp SysS yue Cyyl ae Lyall ul CS Sto os yl) (Q4) = (Volt x tsext.732)/1000. {@11}=480x20919x1.732/1000= 17391 kva 16 eld) J paul! ga) 338 Motor Inrush (Vd)}= (Irsm) / Q1 {Vd) =1710/17391 =9% Voltage Drop at Transformer Secondary is 9 % which is within permissible Limit, Ld AD Ju oe 65 asi I J Le =6596"1203=481, ATT Dad Loe SI wy teal gh Joe Hh 818 are 1 speeds wal for Pelied mot and motors with sonal ome charac nis The voltages ited are tated motor vollages. The curensliste shall be permited fr system ota ngs of 110 120, 2010 240, 44010480, er $80 10 60 vo, ‘Synchrony Power Indction-Type quia Cage and Wound Rotor Ampere) stor (Ampere) a er ae 200 Apert aeeeeae aena 7 ‘onversion Table of Polyphase Design B, C, and 2 Stain Locke Rotor es ‘of Disconnecting Means and Controllers as Determined from Horsepo and Voltage Rating and Design Letter For use only with 430.110, 440.12, 440.41 and 455.8(C). Maximum Motor Locked-Rotor Current in Amperes, Two- and Three-Phase, Design B, C,and D* 115 Volts 200 Volts 208 Vous 230 Volts Be Vonks GH 575 Vous ated mei GD oon GD <= x 3 Bs Ba 3 tas i I = & x 2 te : im ms 5 2 * 3 ae ne x a 20 4 = te ‘s 2 sau i = ise i Te os A = x a x 3 2 a aH mn bo q = = > tor se us = = ier ou so ms = = ro 2 7 =r a wor x im 3 : 12 120 ‘os os o = teat tas m3. se ts an aon me I - a ao 2 vs ‘en A - as Sm, in 10 ws 20 ; : : : Tas 10 Fe = E e - hn te ss = = = = i 0 = = = = = a0 i s = = = = a xan Shea yaad Ay lal 5 lt) Gla ebeaal) Dyed ib lee Yi Used e: DS seal Mz Px75 x9.81 x5 x(1-CF)/ EF P is the rated passenger number in the car; seat lo AS fh ase 75 stands for 75 ke/passengers; see als SLU bes 9.81 Is the acceleration due to gravity; yShal ge, sis the rated top speed; seed de ye CF is the counterweight factor (a factor less than 1); 1 is the total efficiency of the installation (taken around 85%). For a hydraulic lft, the same formula can be used by replacing CF by -1. oe Anis %75 sedis Si; 13 ssl Llp 1.2 Ate pa senee t.5 counterweight 50% ssl! ane cue! oo BAD ed Go y=13 x 75 x 9.81 x 1.2 x (1-0.5)/0.75=7.65 Kw is BE BS Ss GAN an Se ai he counterweight 1 %65 SiS cals WS}, 78 Ais) Jaa ABE 51 ene VVAC EO ae Shy ratio of 45% al P=78x75x9.81x1x(1-0.45)/0.68=46.4 Kw Sly S50 OSs le SS 20 Ai oe pS gigas ea 80 ASA) A fp 1 ey lS, 8 aed hydraulic lift S89 os salsa aia counterweight ratio Sly hydraulic 42.5) Ly iN ed Gt ty P=8x75x9.81x1x(1-(-1))/0.8=14.7 Kw Sy BS 16 Aaa st Geli) asa de yl) sya cb ll Curve: pa JSS Kuni agg CSS) Gu aya lal ey | 050 (30 200 250 \09 350 400 450 San 2 Figure 3: System efficiency against speed Sal DL pad gyal gla, 2B Escalatord sisal) ahaa bit Sat aa P=(mxgxnx(Re/Rs) Sin(@) x s+Ph)/ns x ng x1000 im S13 0.35 hueshin kg (usually 75 ke) g Asie ne(9.81 m/s nad sx step 51, 15 oF 2) Re 231 JU AY gs YI Rs is the step rise in metres (usually 0.2 m). FSO SAS A fe SDL de 5. (0.5, 0.65 0F 0.75 m/s). PH SSa ie lial Lassi alblthe handrails nS *lSstep band. NG *USgearbox oe ARO) cl ona escalator Sail pail) gig da gale AGM 500.75 Ae pally fie 17 UG NN daar Gy The motor has to run at 630 rpm ga step rise =0.2 Maas V3) handrails =Akwesdiual) 5) oa 8 WB sls synchronous speed to 630 rom is 750 rpm, achieved by selecting a motor with 8 poles (4 pairs of poles). This motor is rated to run at 720 rpm. Hil Asal gd as P=75x9.81x1.5x(12/0.2)xsin(30)x0.75+4000/0.95x0.87x1000x(630/720}=39.86 kw dO yA dyna joie gl RS a pe 24 Passenger*weignt Where: 18 P is the output power required from the motor in kW. m is the average mass per passenger in ky (usually 75 kg). G is the acceleration due to gravity (0.81 m/s"). nis tho number of passengers por step (1, 1.5 or 2) Re is the vertical rise of the escalator in meltes, Rs is the step rise in metres (usually 0.2 m). @ is the angle of inclination of the escalator. ‘is the linear speed of the escalator in metres per second (0.5. 0.65 or 0.75 m/s). Pitis the power in Watts needed to keep the handtails moving, nis the efficiency of the stepband. nig Is the efficiency of the gearbox. Note that this is the output power provided by the motor, which is the rating of the motor. The actual electrical power into the motor will be higher, where the difference accounts to the losses inside the motor itself 25, olyall Glos Gls, 26 a Ut Bangs seal! Guile ge GEG gles yiny GUbl) jin 3 Sb EUG! pg piss slocl 10 Ge C9Se isle pastel OAS y QEIAIy papa g chal 236 Glan Galan ie al) fa 3353" 11 = ll gla) 482 60=6"10 = iS Sisal ase Wa go lay ASAD Shae gD se * 4 = ag AAAS Mal alll AS 2 yh pall Jane BY 9 240=60°4 = ( ch! ame) ole 4S Bp 14.40=0.06 * X83 / 3 240 algal SS 27,36) Gil Jona ga = paul) eb Lat 2.9 =27.36/240 3s = ss! ht G83 se bt ete hall gh ged tall 88 Side ph 12* Shas gl axe "3/1: P=10 mtr + building high +(0.15xbuilding high) P=10+33+0.15*33=47.95 mtr =4.8 Bar 4485 31-120 2/240 34.85 o/3- 0.72=0.06120 3) 442/78 120= Aula USI Gist OSE ye Ryall JSD a pall Goma i hl G31 2=45.6/120 ss =45.6/ Gill does pian ll gb oh CS ComtignS Lcaall ane cil asi GS 6325 LEUS | Las Pump=SP x ex Qn x Hn/106.82 pump =1x(120x0.06)x48/106.82=3.23 KW 27 Lapesi ssi oe AS) Conall Cine alge Scns Cus Static Suction Head{h2)=0 Meter Static Discharge Head (h1}=50 Meter. (Q1=300 Liter/Min.)lestias il alyll Gis] Jone (D =1000 kg/M3)s\s 4 pe=B0% Sal 5S me= 90% 255s Sols 9630 sel all gd USGA) a oa) 13¢ ll 4883 | 0 Gaal! Jane J ae Q.=Q1*1.66/100000 3: Jase =3300x1.66/100000= 0.005 M3/Sec Actual Total Head (After Friction Losses) (H) = (h1+h2)+((hi+h2)xf) Actual Total Head (After Friction Losses) (H)=50+(50x30%)= 65 Meter. 308 /3- 0.005 = Pump Hydraulic Power (ph) = (D x Q x H x9.87)/1000 Pump Hydraulic Power (ph) = (1000 x 0.005 x 65 x9.87)/1000 =3KW Use gle Renal a oh Motor/ Pump Shaft Power (ps)= ph / pe = 3 / 80% = 4KW Sigal SUS le aaa ah Laas yg pp Gans 9 ib alls oy Required Motor Size: ps / me =4 / 90% = 4.5 KW Required Size of Motor Pump 5 HP or 6 HP HPS shea ing Spe 33 Cs 380 seal ASI) pak JUS Qld) aes GS. 28 NEC 430-2509: c+ FLC=7.6x460/380= Adseadl e g! FLC=HPx746/1.732x380x0.8x0.9= 7.87 A FLC =7.8 ASt vl Spall ooh el 9.2 ASNEC Sule co 81 Aa Jos NEC 430-523 8) Ussal} ue abil [csi Maximum Size of Inverse Trip Circuit Breaker =250% x Full Load Line Current. =2.5 x 9.2=23 A el 25. eal 9 Sa NEC G+ SA ll Syne Gun AS he a NEC Code 430.22 (Size of Cable for Single Motor} Size of Cable for Branch circuit which has Single Motor connection is 125% of Motor Full Load Current Capacity Min Capacity of Cable= (9.2X125%) =13.8 Amp. De rating factor taf cle i 8 tends pa 0.8 Sy I rated for cable = 13.8/0.8=17.25 A sel 27 Jasss Sle 2.5 JS VD Goi VD= mya x Ix L/1000 VD=13.197 x 9.2x50 /1000=6.07 = 6.07/380x100%=1% Size of Cable = (3x2.5 +1.5 JMM salad sgh AsS Stila Sul a as NY! Min Thermal Over Load Relay setting =70%xFull Load Current(Phase) Min Thermal Over Load Relay setting =70%x9.2= 6.44 Amp 29 asLagu Aad Si: at Max Thermal Over Load Relay setting =120%xFull Load Current(Phase) Max Thermal Over Load Relay setting =120%x9.2= 11.04 Amp dan ype Sure Cap and Won ator Ampere) porate: Nitaple 220.6(A) Standard Amp Ratings for Fuses and inverse Time Circuit Breakers fectricallicenseReneural.cam as 20 2 | so 3s 20 as 50 60 70 20 90 100 aa0 aes 350 375 200 225 250 300 350 400 450 500 600 700 800 1000 3200 1600 2000 2500 3000 2000 5000 6000 ae ay aay come ashe ste Sal) At gS) caput Jia 31 PCrions Bait y Setting / Fuse / Cable for DOL STARTER, HP KW FL Centactor Relay setting Fuse Cable (mm2) ‘Size (amp) min cu atu os 0237 1 = os az ase 1 074 8619 ° 16 22 cess ia | ae ° 2 = 6 1s 25 2 149 387 ° 25 a7 jo 15 25 2 220 48 ° 4 59 1 18 25 5s 373 78 ° 63 94 z 15 25 7 S22 na 12 a az) 25 28 4 10 746016 16 125 187 2 4 6 25 932 19 32 16 23a 32 4 6 1 1119 208 a2 16 234 50 6 10 20 1492 28 32 20 20 so 6 10 25 1865 34 38 32 s74| 68 10 16 30 2238 40 4s 32 a7 eo 16 2s 40 2984 = 53 a so so 100 253s so 4476078 as 70 289 125 25 50 75 5595 96 110 3s 982 160 50 70 32 Gua) Gladaad GOUT QU) Sylas 33 eal ddd COYGy Ql) chow Willie oo at St Ge a Guo S aay Fire Fighting Pumps Ge Cuad Laie {NFPA 20: Standard for the Installation of Stationary Pumps for Fire Protection Chapter 9 2-NFPA 70: National Electric Cade (NEC) Article 695 AIS pa Cita tay Ie Main Fire Fighting Pump =50 HP , Voltage=460 V Jockey Pump =2 HP,, Voltage=460 V Calculate Size Of over current protective device(OCPD) bal tye gS) paw GIS 3h: Yuh (URC) locked rotor current asin git) es py sl 9) aan le slant ony NEC Table 430.251(B) or NFPA 20 Table 9.5.1.1 1. LRC for Main Fire Fighting Pump = 363 A 2- LRC for Jockey Pump=25 A Total LRC=LRC (Main)+LRC(Jockey) As per NEC 240.6 the next size standard Overcurrent protective device (OCPD) is 400 amps. yall olysgSl yee GIS gh: ‘The OCPD is sized to allow for instantaneous pickup of the full pump room load only, not the LRC. The OCPD is not required to provide any overload protection, only short-circuit protection Standby of generator el: 4S!) joes OSly pled Jal) NEC Table 430.5206 FLC Ge Ciba (5S iy NEC 25) Gan Ge 1: FLC for Main Fire Fighting Pump 50 HP =65 amps. 2-FLC for Jockey Fire Fighting Pump 2 HP =3.4 amps. 34 AS Per NEC Table 420.52 the maximum rating for the inverse time breaker OCPD is 250% OCPD= 250% x (65+3.4)=171 A The next standard size OCPD is 175 amps average =175%4aill sla Wi pad %250 ol! %150 Gy dail! abode San y OCPD should be rated=175%*(65+3.4)=119.7 = 125A V4160 4 GSI spall he GIS Ip RAL call Jy ea GS FLCX 125%= 68.4 x 125%=85.5 A Transformer Size = V x A X1.732/1000 Transformer Size = 460x85.5x1.732/1000=68.11 KVA The next standard transformer size is 75 kVA (primary Josie) 86 ly lS (lta Jeb) tans os AS LRC =388 Alisle Stall Go Transformer 4160 side protection =460V/4160 x LRC at 460V Transformer 4160 side protection=460/4160 x 388=43 A Next stander over current protection for primary side =50A. aid 2,60 5 8I Clash Geyall Shae skys Jpn! J le Total Transformer = 125% x fire pump motors and jockey pump+ 100% of the remaining loads. Ag) joe Ge Stall Sal da G35 Ga CUS has 9 8S gma ye p58 200 Hilees cle Jy fash dmg sis cll COLI OSI, FLC%125 = JAS i lee Ys) =125% x 68. 5.58 (NEC 310.15)B16 Js G+ 75 3S palin s THWN #3 AWG copper cable is sufficient Thermoplastic High Heat-resistant Nylon-coated".» Juais! 4) ule VODs nis Cates 35 NEC 2380) cue ple Cait ox) a6 15 Spall Spat oh VD=1,732xKxLxI/Cmils k= Resistance of ohms for copper =12.9 ohms Cmils=1.732x12.9x200%388/460x0.15 =25.099 CMILs/1973.5-MM NEC- Ch-9-table 8 Joss ce #3 AWG cable is 56,620 Cmils and is sufficient The second calculation is for 5% max voltage drop at 115% FLA Coils = 1.732x12.9x200x68x1.15/460x0.05=15.265 2 #3 AWG cable is sufficient. Therefore, a #3 AWG conductor will be used to supply the fire pump system. GAD Red AL je Gk is SUSI eb aps penal aa This is based on the upstream OCPD, equivalent to 400 amps, #3 AWG copper conductor per NEC Table 250.122. 2S pets Gpatigl line ule Sol Ll Sug Akall Ge Magnetic unt trip protection Hid hill puts i BY Should the FRAME of the circuit breaker meet the rated current OR just the current sensor of the circuit breaker? val Ube Fire Pump SSkW (87.94 * 6.7) 597.728; Circuit breaker (Compact NSK100 model with only MA Unit Trip - Schneider) = In 100A - ‘Magnetic Unit Pickup (Im) = 9 to 14 * In Setting Im = 9 * In= 9 * 100A = 900A Im = 900A> $97.72A (LRC) fire pump 36 Conversion Table of Plyphase Design B, a Min ace or ection of Diaconmecting Means and Contrlles ax Determined rn Horse ad Voltage Rating and Design Letter For use only with 430.110, 440.12, 40.41 and 458.8(C) ‘Maximum Motor Locked-Rotor Current in Amperes,Two- and Three-Phase, Design B, Cae D* ma ET eva tne RGD nGD” RGD RGD ® 2 i bs ® 3 x : i 3s 3 : x ; : Be x “ 2 ; = sot : “ = i i i is m7 = ins ——13 ie i 3 7 i i it E = i Fa ts : : = = s FA 3 : a au 0 3 = = co a 7 = : - ia tno ins a a = ta ta M0 is = fe Sn iis ‘ ts i Fe Hm ms x BS san Saigo = Tas i : 5 : . sn * 7 : : = aa = - . 7 sa & 30 7 FIGURE 1 ALLOWABLE AMPACITIES Thetwo conductortypes copper and aluminum or copper alinun) are divide into thre categories ach: °C (140, 75° (167) and 9 (14), Table 310.15(B)(16) (Formerly Table 310.16) ‘Thrmparatura ating of Conductor ercowrn | scnera | orci) | cacy | TCE | rca) per sas, FR MK ‘yperessh ANTM SETH THN, THAKTHNS, TR THON ‘psn, THAN, THUS, Hp ATH, RAE SoG pet THATHN, OL IHMICON.Types TWRTHWN, HK HH, crcmt THU | WUSEZW | 220 TK MSE WZ Copper Aurdsum ot Coppr-ladAluru 2 2 5 a a % Cy s 5 » s % 0 1 » s « » 3% a 8 ° 2 5 “ a 8 ‘ s 6 8 ss 6 % ‘ » 5 6 ” & 6 3 5 iT 0 & w no 2 5 us oy 6 Ws » 1 0 » cS Ww w rr) *Se10440) Conductor ses ange fom 18 ANG to 200k Equivalent data for single insulated conductor is in Table 310.15(B\17) (formed Table 310.17). ‘Theampaciesin Table 31015816 are basedon not more than thee cunen-canyingconducersina raceway, cable or earth dec buried. Theampactisare as based onanambient temperature of 30° (86°, Ampactiesvary depending on both thetype of conductor andthe insulation properties. Table 31015(8(8) provider maximum slomble pact of ult conductor rtd pt nding 2000V. Ampaite very dapanding on boththa ype cf conductor end the ination proper. laden type Sgueel Cage ond Wen Rote Uap Fire Pump Motor Continuity of Power 695.4(B)(2)(a) 450A Overcurrent Device 25 hp, 208V, 3-phase Fire Pump Motor ae Fire Pury [Table 430.251 (B)] =< e 39 ela gSll Cla gl) alll lees ela sgStl cla sll shall Gila Aaius Bus bar Current Details: Rated Voltage = 415V,50Hz Desire Maximum Current Rating of Bus bar =630 Amp. Fault Current (Isc)= 50 KA, Fault Duration (t) =1 sec. Bus bar Details: Bus bar Material= Aluminum Bus bar Strip Arrangements= Vertical Current Density of Bus Bar Material=1 das De rating factor from attached tables isi tus =: 3) Total De rating Factor= K1 X K2 X K3 Xk4 XkS X K6X K7X kB Aid yall Jylaall ay Number of Bus Bar Strip per Phase (K1)=1.83 Bus Bar Insulating Material (K2)=1 Bus Bar Position(K3)=1 Bus Bar Installation Media(K4)=0.8 Bus Bar Artificial Ventilation Scheme (K5)=0.9 Volume of Enclosure & Ventilation De rating Factor (K6)=0.95, Proxy Effect (K7)=0.82 Altitude of installation site (Meter) (K8}=0.88 1x1 0.8x0.9x0.95x0.82x0.88=0.901.83= celal ¢ pana 0.75 als aj aie gas Se Aaglen 41 tl Bll ol 630 al Current Rating of Bus bar after De rating Factor (I1)= [2 / De rating Factor {I1}=630/0.9=700 Amp > Bus bar Cross Section Area as per Current= Current Rating of Bus bar / Current Density of Material TEA ine Ay ppelyl) Le US le alll by pon ae il La pt ap T= paid! Ua US, 1.6 = ela al) MAUS le tare > Bus bar Cross Section Area as per Current= 700 / 1=700 Sqmm. Spe yp le Lal ale aay ps ay > Bus bar Cross Section Area as per Short Circuit= Isc XV ((K/( 8tx100)x(1+ 20%6) xt x = temperature coefficient of resistivity at 20 deg.C/deg.C 0.00393 for copper 0.00386 for aluminum K = constant =0.52 for copper =1.166 for aluminum GIS HLS Atel dagd ol ghd ‘A (AL) = (Isc/0.079) * vt (For Aluminum) ‘A (CU)= (Isc/0.123) * vt (For Copper) > Bus bar Cross Section Area as per Short Circuit= 50000XV ((1.166/( 100%100)x(1+ 0.00403%85) x1=626 Sq.mm_ Abaya 5 AU) Abba 8d gl gli ‘A= (Isc/0.079) * Vt (For AL) =50/0.079* 532 sq mm Sp Syl ye 9S oS yy Sh gas JEN Ul oe SGI Sa a ete SGM of apes Ub 700A »STY oe 632 5 700 dal oe SY) Aaa ids Gi pe Clin ah Gp 80x10=800 Sq.mm_ length =500 mm bus bar Area per Phase = Bus width X Bus Thickness X Length of Bus X No of Bus bar per Phase Bus bar Area per Phase = 80x10xX500= 400000 mm 42 Number of 8us Bar Strip per Phase (K1) No of us Bar per Phase 008 1 173 245 01 1 18 255 ow ' 198 208 o2 ' tot 27 (2) Bus bar insulating Materit De rating Factor 2) 1 Bus bar having Neineuiaing materia tie Bare 0 folowing Table erating Factors + ‘us Bar nsuating Matera 2): ‘be rating Factor Pvc steewna 12 43 + (8) Altitude of Bus Bar installation De rating Factor (K8) ‘= Alttude of Panel installation on Site is 2000 meter so following Table = De rating Factor is 0.88 Altitude of instalation site (Meter) (KB) De rating Factor 2200 oss 2400 os 2500 08s 20 oas 2000 oss 3000 083 3300 oa 3500 oat 000 o7e 4500 076 000 o7 Volume of Enclosure & Ventilation De rating Factor (KS) cross Section area of Bus indoors (Panel is well Indoors (Panel'8 POSEY. ttaoy br/Total Bus Bar Area Ventilated) ‘Ventated) on oes oes oss om os o7 os 10% oss oss os + (7) Proxy Eftect De rang Factor (7) ‘+ Bus bar Phase Spacing (0's 400mm + Tota Bus length of Phase win spacing W =75+75+75-75-75=225mm Bus bar Phase Spacing ()/ Total Bus lnatn of Phase with spacing W@ = 400/225 =2 * From fotowing Table De rating factor is 0.82 Proxy Entect (7) De rating Factor Withstand time Fault Level (in kA) Lsee 200msec | 40msec | 10msec 35 443 198 89 44 50 633 283 27 6 a 823 368 165 82 35 285 27 37 28 50 407 182 a1 at 5 528 236 106 33 45 current carrying capacity In amp ( copper) at 38 deg.C of bus) DC (no. of bus) I m jo ft [a [wm [or 110 15_ [205 10 15_ [245 70 175_[305 185 190_[325 220 25 [390 25 300_ [510 270 273_ [47 350 315 320_[ 560 400 410_| 720 20 B0_ [740 520 330_[530 760 1850_| 2500 | 77 1400 | 2000 630 1650 | 2100 [650 _| 1150 | 1750 320 2250 [3000 [960 [1700 | 2500 760 1760 [2400 [780 | 1300 [1900 1060 2600_[ 3500 [1100 [2000 | 2800 970 2300 [3000 [1000 [1800 | 2500 1380 3100 | 4200_| 1450 | 2600_[ 3700 1200 2850 [3500 [1250 [2250 [3150 1700 3000 | 1800 | 3200 | 4500 2000 4100 [3700 [2150 [3700 | 5200 | 6700 2500 3300 | 7300 | 2800 [4800 | 800 [5000 3000 6350 | 8800 [3400 | 6000 [8500 | 1000 46 Wis = hw peas CAS yall agl BS y 5 gully Qlalil) Gila 47 Star Al ili N) sl) g gi pad gl Ag 5 gall y QUAN des Gua Ste delta The System Voltage 415V ,10HP Three Phase Household Application Induction Motor , Code A, Motor efficiency 80%, Motor RPM 600, Power Factor 0.8 Put in the wingdings (overload is placed after the Winding Split into main and delta Contactor) or in the line (Putting the overload before the motor same as in DOL). dati lg Ayal je lua = 2 Yh 1-Basic Calculation of Motor Torque & Current: Motor Rated Torque (Full Load Torque) =9500xKW/RPM Motor Rated Torque (Full Load Torque) =9500x(5%0.746)/600 =119 Nm ly 3S 30 Ge Badd de IS Obst pe Gat ew oS Motor Starting Torque is 3xMotor Full Load Current Shy US 30 Ge aSi IS sly Motor Starting Torque is 2x Motor Full Load Current Sly AS 30 ye DB jadlb all Gay Motor Starting Torque: 119=356 Nm. Motor Lock Rotor Current =1000xHPx figure /1.732x415 LAs Saal vesCode A all use yaad 8 MIN=1 & MAX=3.14 Minimum Locked Rotor Current =1000x10x1/1.732x415=14 Amp. ‘Maximum Locked Rotor Current =1000x10x3.14/1.732x415=44 Amp. 48, AG ASY Absteall Ga FL Giluuny agi 1 4th Motor Full Load Current (Line) = Wx1000/1.732415 FLC for Lines Motor Full Load Current (Line) = (10x0.746)x1000/1.732«415 x0. 8x0.8=16.2 Amp. Galall NEC 430 Jose Ga Gs Lt Lens ait! +=32.2x200/415=15.5 AMP FLC for phasechiua. 2 Motor Full Load Current (Phase)=Motor Full Load Current (Line)/1.732 Motor Full Load Current (Phase)= 6.2/1.732=9.3 Amp S DAMS GA FLC 4 hye 3B Oe 98s hy pall SS ey Ut leas 9 il lll ony Motor Starting Current =3 x Full Load Current. Motor Starting Current (Line)=3x16.2=48.6Amp Fuse Sizechtus ; ii Fuse as per NEC 430-522 af) stall Ow No Time Delay Fuse ji € si p2Siuis y 388 3 Induction Motor “1 yaal € 35 Maximum Size of No Time Delay Fuse =300% x Full Load Line Current, Maximum Size of no Time Delay Fuse =300%x 16.2= 48.6 Amp. As per table 240-6 size =50A -Time Delay fuse FY! ¢ sill plasty Li 13] Lil Maximum Size of Time Delay Fuse =1.75% x Full Load Line Current. Maximum Size of Time Delay Fuse=1.75%16.2=28.35 Amp. As per table 240-(6}=30A, Ayal QBN) Cilla: Lal Circuit Breaker as per NEC 430-523 3) Jssell Oo -Maximum Size of Instantaneous Trip Circuit Breaker (Protectors MCP) =800% x Full 1 Load Line Current. 49 Maximum Size of Instantaneous Trip Circuit Breaker =800%x16.2= 129.6 Amp. As per table 240-(6)=125A, Maximum Size of Inverse Trip Circuit Breaker =250% x Full Load Line Current.2 Maximum Size of Inverse Trip Circuit Breaker =250%x16.2= 40.5 Amp. CB=45A Motor Protection Circuit Breaker (MPCB)=125% x FLC3 MPCB=1,25 x 16.2 =20.25 A CB=25A olor aga sh Ciljlos + Lol SGU ag ASU Lad BIG) Min Thermal Overload Relay setting =70%xFull Load Current (Phase) Min Thermal Overload Relay setting =70%x9.3= 6.51 Amp S pul ag Ag Aad Si: La Max Thermal Over Load Relay setting =120%xFull Load Current(Phase) Max Thermal Over Load Relay setting =120%x9.3= 11.16 Amp a8 Ged eee casline J sy Zod ay eae GAN fle Gig 8 plea lj yl ane ag] 9! ean Star/Delta ily: a A cM 8,5) A yaall LAS Joa LS ge 2) VI dane oi AMT all Gi Overload) =1.15 *motor full load current 1 (Overload)=1.15"16.2=18.63 A Ha Jang gay yall Jah le 9) iI dana gp all aa! Gd. 2 (star)= (1/V3) * motor full load current = 0.58 * I(fl) (Overload) =1.15 *(star) 1.25 oJVS8! pS NEC 258U Vike 1.25 i) 1.15 Ge aaa Ss cs | (Overload) = 0.58*16.2=9.3 A | (Overload)=1.25*9,3=11.6 A pgiSUES gl) Giles + Lendl Selection of contactors: AIS. SLA 9 Main & Delta Contactor 1 +sils—1 I (Main Contactor &Delta Contactor )58%" FLC Star Contactor 2 suche 2 | (Start Contactor) =33%"FLC 4 ads dyall Type of Contactor= ACI Making/Breaking Capacity of Contactor= Value above Chart x Full Load Current (Line). Making/Breaking Capacity of Contactor=1.5*16.2= 24.3Amp. Size of Star Contactor (Starting Condition) = 33%X Full Load Current (Line). Size of Star Contactor =33%x16.2 = 5.3 Amp. Size of Main Contactor (Starting-Transition-Running) = 58%X Full Load Current (Line), Size of Main Contactor =58%x16.2 = 9.3 Amp. Size of Delta Contactor (Running Condition) = $89%X Full Load Current (Line). Size of Delta Contactor =58%x16. = 9,3 Amp. NECuan cle A yaall COLI) Glue: Laglae NEC Code 430.22 (Size of Cable for Single Motor): Size of Cable for Branch circuit which has Single Motor connection is 125% of Motor Full Load Current Capacity Min Capacity of Cable= (16.2X125%) =20.25 Amp. autiall JHSII_ S855 derating factor Uslas pladiuls » ji ullis sey Si ape A ly ell en as SOS any 16.2x72%=11.66 A Safety Switch Glua-; Lali Safety switch =115%xFLC 51 ‘The folowing Rina re eee ul are yp: et spoads usual for heli mows aa motors with aol tore charles “The voltages listed are rated motor volages. The cures listed sll be permite for syste voltage ranges of 110 to 120,220 to 240, 4010480, and $301 00 vos, Syechrnme type Uaky Power IadactinTyp Squil Cae and Won Rtar pee) rar Ampere us 20h aiaers 2300 a ne ee) Werwpore Wate Was Was Vamsi ’ 44 a eee) 5 \ 4 Sm hm & os So ¥ 10 ane wo 28 2 1% MOD 3 = 0 6 ak ar 3 -_~ oe ee wo oa vo 2 as 4 1s = © @ & a gS —_ oo = m » - wm ek om me oo —o = m 2s -— 2M © Be go os = a x” =~ nh © 6 @ & = & 2 & = 0 mw Pe) x ae i 2 @ « 7 ist i 8 & & ft % e min ge & @ & § oa mM » mm mo HN 2» = op Fe ee a 130 - a2 = © Gc ok ae x so wo a oe ot 0 2 @ x0 so 5 s Md B = = © & "] Se es woe Bo ee 0 — <8 ym 5 = = = ‘ a of we 2 oe = = = x0 0 un 52 Sot aoa 53 DOL Epil) cys CAS poll ag GL y gall y QlatAl Glee DOL 4 ASA Ag gh Aa ash Ay 5 lly QR Kaas eal The System Voltage 415V ,SHP Three Phase Household Application Induction Motor , Code A, Motor efficiency 80%, Motor RPM 750, Power Factor 0.8, Overload Relay of Starter is Put before Motor. ga Hil Dynal 956 has = Wy) 4-Basic Calculation of Motor Torque & Current: Motor Rated Torque (Full Load Torque) =9500xKW/RPM Motor Rated Torque (Full Load Torque) =9500x(5x0.746)/750 =47 Nm 5 15-30 oe aa ne 2 Oost pie da ey OS Motor Starting Torque is 3xMotor Full Load Current 30 co Sl dy Motor Starting Torque is 2x Motor Full Load Current Sly JAS 30 Ge il pal Ja ny Motor Starting Torque==3x47=142 Nm. Motor Lock Rotor Current =1000xHPx figure /1.732%815 A Thal) cus pall 2S ¢Code A 1 aby stall cay MIN=1 & MAX=3,14 Minimum Locked Rotor Current =1000x5x1/1.732*415=7 Amp Maximum Locked Rotor Current =1000x5x3.14/1.732x415=22 Amp. ASRS saa Sa PLC een Motor Full Load Current (Line) =KWx1000/1.732%415. FLC for Line Slee -1 Motor Full Load Current (Line) = (5x0.746)x1000/1.732%415x0. &x0.8+8.1 Amp. 420 Sad NEC Te cx 31 55, =17.5x200/415=8.4 A FLC for phase isbn -2 Motor Full Load Current (Phase}=Motor Full Load Current (Line)/1.732 Motor Full Load Current (Phase)=8.1/1.732=4.6 Amp DOL a A FLC Se Se 7 6 es Ayal GR oe as pS a Motor Starting Current =6 to 7 x Full Load Current. Motor Starting Current (Line}=7x8.1=56.7 Amp Fuse Size ives ; tit NEC 430-52 83 Sstadi ce Time Delay Fuse >All g 5 esta» lh 3 » Induction Motor Lona! & 5 Maximum Size of no Time Delay Fuse =300% x Full Load Line Current. Maximum Size of no Time Delay Fusé 100%x 8.1= 24.3 Amp. Time Delay fuse FA! ¢ al) psa Ly Maximum Size of Time Delay Fuse =1.75% x Full Load Line Current. Maximum Size of Time Delay Fuse=1.75%8=14 Amp. Spal QB i 3 aly Circuit Breaker as per NEC 430-52 3 83 Sstal! cx Maximum Size of Instantaneous Trip Circuit Breaker =800% x Full Load Line Current. Maximum Size of Instantaneous Trip Circuit Breaker =800%x8.1= 64.8 Amp. Maximum Size of Inverse Trip Circuit Breaker =250% x Full Load Line Current. Maximum Size of Inverse Trip Circuit Breaker =250%x8= 20 Amp. AAD ag ASM ches : Lat Min Thermal Over Load Relay setting =70%4xFull Load Current(Phase) Min Thermal Over Load Relay setting =70%4x4.6= 3.22 Amp Salas si Max Thermal Over Load Relay setting =120%4xFull Load Current(Phase) Max Thermal Over Load Relay setting =120%x4.1= 4.92 Amp 56 line J As Thermal over Load Relay setting =100%xFull Load Current (Line). Thermal over Load Relay setting =100%x8.1= 8.1 Amp Sg: La 4s Joah Type of Contactor C7 1-Size of Main Contactor = 100%X Full Load Current (Line). Size of Main Contactor =100%x8.1 = 8.1 Amp. Making/Breaking Capacity of Contactors eu = Value above Chart x Full Load Current (Line). BG Sin Ay Apsall a 3 aby apaall gad Making/Breaking Capacity of Contactor=8x8,1= 64.8 Amp, NEC lo eal COALS gate: Lge NEC Code 430.22 (Size of Cable for Single Motor): Size of Cable for Branch circuit which has Single Motor connection is 125% of Motor Full Load Current Capacity Min Capacity of Cable= (8.1%125%) = 0.125 Amp. stile! JASI 085 derating factor Je padid AS any Sa aoe ————ae adadadalegsnaaiaa ' 7 ‘eed rol nme i oma pe cet The lg ied at bap The aes eda be perm fo qt ae ps 10 (2) Size of Circuit Breaker: ype of Motor ‘Single Phase ‘Synchronous rect Curent 220402 A, a 0 oo ning Suto Wd at pr) us 200% 200% 200% 58 (Circuit Sreaker as per NEC 430.52 Syme tat oe poe Fe Y lyse 250% 250% 150% NEC que ge Cis all igs ppena OF Ge pale 59 Scope of American Standards oi also) ¥¥ 34) 1LFacility (NEC All Articles) 2-Machine(NEC Article 670&NFPA 79) 3-Industrial Control Panel(NEC Article 4098UL SOBA&NFPA 79) 4-Motor Circuit(NEC Article 430&NFPA 79&UL 508A) Industrial Control Panels’) pity iad a JY =: Gis 34 1000 ce 932 Y Seay SA pal SK ee 1 aka OSB Overcurrent Protection Devices & Disconnect Switch &Contactor & Overload relay) NEC CAS jal) igh alg chal Single Motor s9!y 4a+.ciyius -1 sled ale Saat Gl SY Avy Synchronous Type Induction Type, Squirrel cage, Wound rotor 821 Gh yal ssall jl FLA say 878/322 Maine NEC Ulam CAFLC ile pl -: Wd ee Ga al Full Load Current (FLC):- NEC Use cae tie Sip pal alantig si) tl Full Load Amper (FLA):- ail 8S yl 4y Caldas Gold Name Plate le Sisal J) Jaa Ls FAse JSIFLC Las a LA NEC Sule Gi aisle oe ea OS 41S 4 Cas 5 583 LaWFLC eel Je Sota) A seal) AS XInd A see AS= SU sha ps Gd Joe A Ase ge 415 el 460 sea) Sy FLC FOR 5 HP =7.6%460/415=8.42 A Lak 5 cue si de sy NEC Article 430 + wall is gS! lati) hs = Lid ‘inverse Time Circuit Breaker (Overload Protection) 60 ial Jas By} all Us (Si5l3 By Spin sl ) date Bae le % 250 91 %150 8 A FIC nas em ey 2-Instantanous Circuit Breaker(short circuit protection) MCPeti Ian easy (Magnetic protection) $313) ACS ye ppb iyi ie all hel) ia all lead pad (SiS13 hy Jose a) Daal gh ee le %1100 § %800 od A FLES py Aan oy MPCBaesn adalat Sw gone 9 a Say overcurrent protection js Lan a say MPCB=1.25XFLC Laas Sue $3 35.519 NECA30-52 cium gle ol pall} yall hae -2Lel 1-No Time Delay Fuse (GAA 3 By Spam shal) A ymall ¢ 8 ee ole %300 3} %0150 Aad od G2 FLC nian iam ay ime Delay Fuse(Dual Element) (Shyal3 y Upse BH) Tale Se Ge HITS 51% ISO EA OFLC A oy NEC430/32u= le Overload Protection hus -tbudls Maximum overload = F.L.C. X allowable % of the maximum setting of an overload, 130% for motors, found in NEC Article 430/34, Max (Over load) }=130% x FLC Minimum Overload = F.L.C. x allowable % of the minimum setting of an overload, 115% for motors found in NEC Article 430/32/8/1. Min(Qverload)=115% x FLC NEC 430.2240 le daa ital JIS Man cle Size of Cable is 125% of Motor Full Load Current Capacity HpS ina aay yyigal asSiuall USM ua) SV an Cuan Jha 415-volt, 3-phase motor at 0.8 Power Factor. os Fullload currents for 5 HP= 7Amp. Min Capacity of Cable= (7X125%) =8.75 Amp. 61 the 4 ules JS) Factor Meds Total Cable Factor= No of Cables X Cable Factor %=93010+846=(15°15.2+40°11.4420°8.1) = Slag Za) he SG pe ll, 993 es SUSI ASU a EA 82 Ly Iocall Cable trunking =100x50 mm 68 Yds doe Y sda Ahmed Essa Ahmed Essa 69 CABLE TRAY CALCULATION ¢s1 5 JAS) Glutite lacs 70 SCABLE TRAY CALCULATION 1 Git! Gata has SIA GAS fe at gt okt GAS ¢ 5 SSL CDMS ase * JIS USI go SI hill = Zhe st) UY AMIS i DAD eS yl) DUIS O26 ay J Sal 338 5.9 2) Jl 57.9 JAS oo $80) jhS Sle 300 GAAS CORE JIS 2 236-1 lf 3S 6.1 039 Jl 68,6 SAD go 38 sah Je 400 Usie CORE S JS 2 2 -2 Fal $805 35 Tu28 a Js Bi Je 25 HS CORE JIS 3 2-3 dle 340.6=(28°3+68.6°2+57.9°2)= sls COSI de all Us) AS US chy * CDA 286 = IF GAS Ae A) DMS Cg sia! SUS 25,5=(0.5°3+6.1°2+5,9°2)= COMSI 3 jy & ame DUS un JI) UY ¢ pane) 4 (COU yp ALi Lua * COSI ase )= CPUS US Lae g pane Jt) LIN taal 3h 410.6=Jie 340.64 10°7= % 20 Spare 223 -¢ SAS BU) padl® CONS gS Cale COS Lalas 1S) @ gepills 33819.8=68,6"493= “DUS Aan '%20 SPARE FOR CABLE TRAY ‘Sq.mm3380 SDAASI JS Ral ¢ yan yl a #4 100* 300 GS is! 8 JIS ule 4! Lice Sq.mm30000= Si i316 JS 4.i0) 4a Checking Width of Cable Tray Calculated width of cable Tray as per Caleulation=No of Layer of Cable X No of Cable Tray Run X Width of Cables, le a93= 493° 1715 ls LIS eae Checking Depth of Cable Tray n Actual depth of Cable Tray iameter of Cable lo of Layer of Cable X Maximum Checking Weight of Cable Tray Actual Weight of Cables=25.5 Kg/Meter_ AVS SS ae At 92300 » hi! oi sill sl 6 JUS see Oe Si pe 493 pam ost JUS Lae Calculated Cable Tray width (493mm)> Actual Cable Tray width ( 300mm) = Faulty Selection 28) SG LS LIS Gee Go Bl 68.6 Gl Li ISD Ge Calculated depth of Cable Tray (68.6mm)< Actual Depth of Cable Tray (100mm) = O.K Alaa! i SD sf DUS O55 Ge aS! obs aD Is JUS Oy Calculated Weight of all Cables (25.5Kg/Mt) < Actual Weight of Cable Tray (125.5 Ka/Mt) =O.K 600 ie Sq.mm60000=100°600= «1,8 JS i) alee SSID gine A529 4935 penal GIS LIS Gane Oe 951600 KSA GL LIS Gaye H+ 68.8 apa IAG Gee Ge Slee 100 LSA G5 SIS! Gee Conclusion Size of Cable Tray= 600X100mm No of Cable Tray Run= No No of layer of Cables in Cable Tray=1 Layer Remaining Cable Tray width Area =17.9% Remaining Cable Tray Area =43.7% n NARSING ELECTRICAL CORPORATION Shop No. A22, Busy B Shopping Center, Bhadakm ora Hanuman Mandir, GIDC, Vap-396195, Dist- Valsad, Gujarat Contact Person - M.S.Narsng (8866821999) Mail: narsing.electco@ gmail.com. THOT DIP Perforated Cable Tray, Fabricated from GI ORHA Sheet inthe standard engih of 2Smirs wifi our” oration. it ip atanine Perforated pte Tray] Teay Depth in en (OT 2 HOT DIP Ladder Cable Yay, Fabrkated from GIORHR Shect in the standard length of Users with au standard perfaraion consisting of we longtudin side ral (Runner Sze: Depth x 20mm) connected by individual Wansverse member (Rung Sie: 35mm 15mm interval of 250. 0 70 Yoo _[-s70—|-660-| 70 [30 3120-510 Fe ET 3770-0 200_|760_|_w0_|_950_ seo 3410] 30. 30 [sea _| 350 | i050 | 60 3560 _| 970 300 [9501050 1350-[ 750 701150 330[ oso 3s0 [200 [ 250 3550] 1760 ‘aco [50 |1200| 1300 | 90 p00 [2807 "aso—[iza0_|-1300_| 1440 | “1000 m0 [-1580. s00_[ ra | 150 [ 160 | 0. 2450 [1820. ‘Gi Coupler Plate & Hardware Price ae Extra {For 25mm Tray -30/-Pes, For SOmnm Tray 40/-Pes, For 75mm ‘Tay -60/-Pes, For 100mm Tray -75/-Pes) Marketed By. — NARSING Electrical Corporation, Vapi ‘Our Standerd Discount : 40% On Above LP Payment Against Pertorma Invoice Pull box & Junction box sizecius 74 * Pull box & Junction box: PULL BOX SIZING 1-Straight Pulls Bapele 9S) Jeb on BN ge SL 8 28% ( pull box) ned He SSS I can HI 4 As Wk ey SI pull box whic I J Minimum box length = 8x 4” = 32" 2- Angle Pulls, U-Pulls and Splices Angle Pulls The box must be the sum of the following: AM BATE pane Jah Sl oe Glaal 6 OS oI ome 825254 bE pal yo Be als Sys se Ie Six times the largest raceway diameter = 6 x 4” = 24” ‘Sum of all other raceway diameters = 2” +2” = 4” 3° Total = 24" +4" = 3- Combination Boxes with Straight and Angle Pulls aid oe sl le) pte BA GS Le gb SI Cy 65 Ll ga aly ie A Gal al ay Straight pull lye 8 1M) AN ABI ye tS Sl ge iy 6 4th saa ale de Je combination pul: Straight pull with a2” raceway Angled pull with a 3” raceway ~ Height Calculation Height = 6 x 3” = 18” Width Coteulation Width (Option 1) = 8 x2” = 16” 75 Width (Option 2) = 6 x3” +2" = 18" +2" = 20" Pull Box Dimensions This pull box must have a height of 18" and a width of 20". Dimension ® represents required distance between ra would enclose the same condi Sizing Junction/Pull Boxes for Angle Conductor Pulls Determining Largest Row ‘Section 314.28(A)(2) = 1% in, 9 1% in. Row At (8x3 ind + 174% 1% 21 in. Dimension A = 21 in. Pull and Junction Boxes, Horizontal Conductors 4 AWG and Larger 314,28(A) Example Horizontal Dimension A Straight Pull: Left to Right: 8 x 3 = 24 in. Right to Left: 8 x 3 = 24 in. Angle Pull: Leftto Right: (6x 3)+3=21 in. Right to Left: No Calculation Largest Calculation = 24 in. Copyright 2017, wa atheH com 7 NECquas (gle CY goal! slit) clas 78 NECoi eS yaad! gba cya. doa Alea at-¥y) Transformer Primary Current (Ip)= P/1.732xVp gaa os gl) yi Transformer Secondary Current (Is)= P/1.732xVs AS per NEC 450.3, Max.Rating of C.8 or Fuse is following % of its Current according to it’s Primary Voltage% Impedance and Supervised/Unsupervised Condition. 4 Bade 8 Ar Stns 2 Soa T By doe ob tl ca an gaat circuit breaker and fuse Hal Transformer Details(P)= 1000KVA Primary Voltage (Vp}= 11000 Voit Secondary Voltage (Vs}= 430 Volt Transformer Impedance= 5% Transformer Connection = Delta / Star Transformer is in unsupervised condition. us esi3h LatTransformer Primary Current c 534) j.iiTTransformer Secondary Current 1000000/1.732«11004 Amp (1s)=1000000/1,732%430=1342.71Amp circuit breaker & Fuse for primary side hus -: Ys) (lp) =52.49Amp and impedance is 5% 5.8600 c+ SI seal 3% 5 Sahel 1 Spal Ge As per above table in not supervised condition Size of Circuit Breaker= 600% of Primary Current 1: Size of Circuit Breaker = 52.49 x 600% =315 Amp. cs) 350 8 315 Ge 9M lia ig 2- Size of Fuse = 52.49 x300% =157Amp 79 Asean Rating of Fuse =160Amp (Next Higher Size of 150Amp) circuit breaker & Fuse for Secondary side lus = (ls) =1342.70 Amp and impedance is 5% 18 600 ol galls %5 talealy 1 Ay Jota! Go Size of Circuit Breaker = 1342.70 x 125% =1678 Amp in supervised condition Jal 3 in Sapa tine AR ANCB unsupervised conditionsis 3 Li (tie ecw Jan Rating of Circuit Breaker =2000Amp (Next Higher Size of 1600Amp) Size of Fuse = 1342.70 x125% =1678Amp 125 st rais LBs Spall ce Rating of Fuse =2000Amp (Next ler Size of 1600Amp) os!2000 cia ol Sy Seal) oe Max Rating of Over current Protection for Unsupervised Transformer More than 600 Volts (As per NEC) Sly doe Primary secondary samp >soavet ~eoovon Moemano% 00% = 300% 225% 129% ¥ aly date ‘Max Rating of Over current Protection for Supervised Transformer More than 600 Volts (As per NEC) Primary secondary imp >600V0tt >600Vett <600Vo08 ce Fuse ce Fuse C.BFuse Up 10 6% 600% 300% 300% 250% 250% ‘More than 6% 400% 300% 250% 225% 250% ‘Max Rating of Over current Protection for Transformers Primary Voltage Less than 600 Volts (As per NEC) Toby dae Protection Primary Protection Method Morethan“2ato9A 9A ? —— 125% 167% protection Primary and secondary 250% 250% protection § by dpe 1 B 0 135 3 x» 70 480 6 % a0 10 10 40 0 175 15 4% 100 200 2 50 110 225 Less than an 300% 250% Secondary Protection = Less than 9A 9A Notrequired Not required 125% 167% Size of Fuse / Inverse Time C.B as per NEC (Amp) 81 250 300 350 400 450 500 600 700 800 1000 1200 1600 2000 2500 3000 4000 5000 6000 SAS yg Aare iy jay a yall 18! LS Generator size Calculation? 82 Ae ay dopo Uy ya 8 CAs Spd Jas ange etl 4 ae gl a! 1-Total Starting KVA 2-Total Starting Current 3-Total Running KA 4-Total Running Current pl aaa ce yell lens ply Size of Diesel Generator= Starting KVA X Future Expansion X Average Use of Equipment’s Total Starting KVAcH Asails HUD Jee! Se Linear Load Jas! cas 3 Starting current =100% x Linear load. 3a EaNo linear load Jaa! cals i UPS, Inverter, Computer Starting current =160% x no Linear load DOLLA es Jinan Se pla GIS IE GIS jars laa] als gl Li Starting current =6 x FLC oS Star Delta css 35 Starting current =4 x FLC 3S by Auto Transformer zm mee. S855 7 Solar Array WWW.ELECTRICALTECHNOLOGY.ORG au & Dc Panel == ocr uo fli Board == (OC Load) (OC Load) oe Distribution Board (AC) — 129 ela gSl Lae! prac Ce Aeaie 130 pall (gb AasSinall (5 jal) (pale opines yaeacill Elgil ale Yl SAY Cosigll 58 (ye GALS Guaies GY Lae Onage Gob 4 pall gi oa ys Types of Estimates eel Fi GDSEI oe gle 1-Order of magnitude estimate 2-Square foot estimate 3- Assemblies estimate 4-Unit price estimate $-20-25% cay all Mad SS Hay lal ob $1596 ial si 44 all oka 410% Hl Ass 4S Hy al oba Labadiad y Aba FS (gy YOS—+ MGM) a oy gS May all ke Tender prices! ¢Usul as pd Oe OSG Costs 3) Ailsa: Y 5} Extra Up! dlaY! lst Cee A pat cle ghaalt 91 Adlsaly Direct Costs! 5 pots Lists.) es Materials pus! go Olaal) jee I skill and unskilledel = Maat Equipments! Slat: Subcontractor 3) Catal! cul ie: Lely 131 aS. ly ay ay JS es LA aes GS pElll Gay Indirect Costs) 5 piles 4 ANS-¥ Od ool pully ite Overhead Ys! es AS 5g Ty Ol ply Qual CLG yo) Gla 2 2 ts Tower Crane is as ai gall e285 coll Gla Seal A Cal pally Mad) Gey Gy pl) Joe all LT Halall ee! y loud) OI SYIE sal A silly yale AS pil) ile 9 pha JS Ga ZA oll ¥ Ge 731i 645: General Overhead Wit Je SULaally 8 LY) GLE yee ally SI lal s Se yaY) Gy weal Ryadl gE SILA y i jag Extra Ups! clblay) ba) 1N0 ll? Ow C31 Gs 4 OSE sry Risk! pbladl danicy y) AY pines ody Gy pskall GB Si gh la! ELE) sh pie jl wali dl Sl Gamer (9S obey ye Sy il call) he Us| Vasa aS 21 5) oI ests Profits! Ges) Hala tit FN9 M+ cou 5155 lly GY fall 45 53 Goliad go olay 132 J elit 3 ll aa cal sit alts 1- Conceptual cost estimates GIS) GSS) Sey Stina pally SUS! 55g 5 phd Gly! JlaiSl pte Se pind olay (%30-0 satiall ¢ 5 pall %20-10 Le Uns! Aaa 5 Sy 2- Semi-detailed cost estimates (%90-30 ata € 5 hal) 3 Lys) OSS) Ey pall GS Gee si Laie psi ohn y %10-5 led Uns! Aad 55 3- Detailed cost estimates 90 alia € 5 pal ys! 5S) ojala LS All slg y pall 3S Lake padi olay (%100 HoA-2 Week Ua dnc oy Sig Saal) AWS y AMS sks Gay QS gill GDGSY! pind Un dy hall ual cghwcitll AMSG) y5 alae} i yas «sr Sas Gatls Boal) 8G ph gs el) GLb eal yo d BMS cle MS (oh) Leg enV) Cant 5H pall y Maliall Gy jt) Malice Es phall Tech areal Leases s Cle) pom? Opa sll vase le Jpasll3 Ban gl pase 2 AyaSll = al yall AAMSS a yall nd weil ctBY! Jane Cuba le Ulead) jae Aleinall eUBY) Yee Gulul gle Glued las -6 amamadall cul fall SsleLae: le J pull -7 Basal dial y Guay Cain y Ci) pall Calg (Contingency and markup)g3 sia pé Seine!) Jest a nal.g (Profit) Jeu lal ge (za gill GS) anai-10 433 Conceptual Estimates 96 30 2 O ce pall Antal ia glad GS Haha» aly lila Sia cal gy all budget 4! 4s juall 8 pad Lyaladiods pi Agahtall AiLadl ALESall a jliiall le glen gle ely ely gS Jac Y USGI osis alse} Say Coll & 5 hall pb Ty hata Base ll Gils gle God Ey pall poe sf Slaa lI ase 9 be Ge nse AS a gasigall Sy Qe ball uy aS Gs GDS Biel gy Ladd AS Fe gana cle ygS Slee) Dis (gj Abbe gy Lhd Alte gy ple pend ae p85 1g 4 pb sli ASI g) Selah) Sie 2 gill Guam lea pe Gf Leas! pokey Glas gf lb AVN label) lads! Sey y Lally Abaue sally lil Laill diy yb le aca y COUGH, Ball gy jbtall Ga SHS! LL em UC=(A+4B+C)/6 Where: UC = forecast unit cost 4=4 sill S35 sll dad A= minimum unit cost of previous projects 4élull a2 ial das Ji) ded B = average unit cost of previous project 4iull g jtall lau yiall dad C= maximum unit cost of previous projects 4:Lal q jal Ua All Conceptual Estimates 4, ,ie Jia 4350 UH JS Aalee s Gey Ge UE V+ ptcte: Se game Oe USSG E 5 pe Eg peball 1d Gb ely yell SbacY Ainzall AaSa lua s glbaally dal 1 pL aes Ty Silas Tylon) Cabos oo yl) Ube Lake Estimates Gala) cid LSYI Joie Gon opal lll ght) Rel ball gb G03. ge zal! GUL Ge Way aby Conceptual 134 Sa elit Estey! fis 350 dala ~ Dub 20 ¢ samall Natl i gh! gst) G gue Cad Sa) le ll 4g Ll) AL gy ball quant pli Gye YU! eon Dsl € a ptall & pee dbs £ +234120.000-000= Lil De) YY 339150.000.000= Sil mill lil ¢ 5 pall ¢ pane el) SA & 5 pial & game Dbi © + 34125.000.000= Ul cell ell Ell Eee dbs VY + 33811 20.000.000= Jill averages as le & spe JS US Aad Guana chill Un=(A+4B+C)/64JG) Usleall 38 Uo pata:bely ideal oy all glial Lagl ga TL gy all da sll Lal LAB Lal gy Lal Ube! all ac Un=(450450+4 x 612612+1000000)/6= Un=650,510 LE Saal ll Dball Sapa ASI Lag. y 31) ose i) Dall 4a gia) AMS yet) ase = ISI g penal! BI 200X650510= AS! ¢ penal) 122,522, 522 LE 135 Ge IS adjustment Jas gl AY Sasa) wall gnats Walle oe Lae 1-Time 2-Location 3-Size prosecrno | costie) | unite inbtaea | soooaco| + webtete | asses |? zebtses | sonoonoo| e 100,000.00 SSs5555666, UC=(A+4B4C)/6) =(450450.45+4x612612.09+1000000}/(6}=650,150.15, Where: UC= forecast unit cost ‘A= minimum unit cost of previous projects B= average unit cost of previous project (C= maximum unit cost of previous projects Adjustment for time-:¥51 index numbers s! time index 448 Glass » sii oI ony Baal ll Adel Ail, penal plu 52 gall dad Ge punt Ales ed Conceptual cost estimates ¢ 5 tall dad GIS Joe Un=LE 843,500 GSAS 5h fh AST Sil al gall (cae Lea! Gye LL al a 4515358 Whe IS 2018 lal antl all a 600 Is USI ary 4485359 Ws IS 2019 lal anl gl Gall a 600 s18 LSI ary 136 4950367 he IS 2020plel asl sl) all o« 600 sl 8 IHS! any 4958378 De GIS Mal plall aot jiall a0 600 sl 8 SHI) pansy The cost index during the 3-year period as follow: (378/358) = (1 +i)3, then i = 1.83% =843,500x(1 + 0.0183)4= LE906,960 Adjustment for location-:tst LAS 6 GRY MSs Ge Deal! 8h Ud ly i) A gall Milde Case Land lea by gine Gigs Es pbal AAS A SLAN g gyal ya AUS Cage pada GHB 6 Call A Ula ayy coe AIS tl hy Gal JS asl ob OS La ge O98 Oc sll ch baad y Cilaeally 3h gall Gals 8 panel 5 ll Jase Sig gl Gans cue 5 all gil ye «Cea gall Sabai Ge eel J On A all pall Gl Lad oll GIS 8 Sal) 9 oy Lee hs AIDS Kae ge gill alin all gil pall Gene Lela GIS yall ol Ua iil Location Index City A=1.025, City B=1.170 City C=1.260 City D=1.105 City E=1.240 gas An A 387200 tesa Bo asl igs phe Lt ASS Gl yo til y conceptual estimatedé pls pladtu! sli DAlssall (gb ¢ sie Silas & 5 pal 137 Solution The cost of the proposed project could be adjusted for location as follows: Cost = LE387,200 x (1.105 / 1.025) = LE417,420 Adjustment for Size-:4 piionn & 4 pln TUSSy ill Glee & 4 poe ye TAISEN plana! Siely le JS) Gye pall ane BDAY Soy Date ela! oi IL in aS ol dage Ge pile JS gy pal Die Haul AMISSI ya Cale alse 3,45 3,3 Gal prall 5351 ll GSM, SN Sl pt ye padi «G4 5s 62700 Aalew inal MS Asal OVI Ge Sig 3 ae AL pine isl Fe 386500 le os sine s U pmene isis 261791540 Als laall a lee € 53 & y pally E Aad Gf Oude JS Abe ela i ya cst pill Ada MAIS) Cae, Proposed cost = Previous cost x Time adjustment x Location adjustment x Size adjustment = LE2,179,540 x (1 + 0.0183)'5 x (1.17 / 1.24) x (62,700 / 38,500) = LE3,700,360 Unit-cost adjustment 8 Baa.5 USMS Gi Y) « pall ge oho jes gg pall len) Aalst! Gi oe ae I gle 535 call gee sis 1800 inline Alii csill J pial! Mal Jussi af ¢ Jal! Janes gle uni eeonll fal bess «Gye jhe [Api B7 Shes clip (yo J je ay po ple UG ene is 2200 A jill Aulsi als 138 aS Jal Ge gs ptiall ane Ge Clits Lea uty chal GUY) Sie jeeliall aa iY Nha Gs Mey idl! gy tall caulsbey paral 2 ght paella She ATGIS Aatine GIS g laa OSs ¢ sil i Aehtie gs Le S any 100 Clas sll ase y 2250 Malis 1 aby g 5 pall 60am gl a2e 5 1485 AUS 2 By gy phall 120la5 sll s36 5 2467 AdS 3 Ab) & 5 al) 150 Sls sll 36 5 2730 Alls 4b & 5 Sal) 190laa sll ase y 3401 Maly Sab y ¢ 5 pLall B05 170 235 6 aby gs pill AUS Guns Jal! Esse USI ba gle Stay JS Glass 5! 22.55 1 ply & 5 pall Saal sll dam sll als 24.75% 2 of ¢ 5 pall baal gl Sam gl Males 20.565 3 ely gy pial Saal ll an gl Alls 18,20= 4a8) ¢ 5 phall dani gl) dan gi dais 17.905 Sei ¢ 5 pall Saal gl an gi Als AMG) Adateal) plained Lh y=axtb. be determined as: y= [(17.9 - 24.75) / (190 — 60)] x + 24.75 = - 0.0526 x + 24.75 190 5 60 ced oy 170 Wels ail oI Ly where 60 < x < 190, then y = 24.75 ~ 0.0526 (S - 60) y=24.75-0.0526(170-60) =18.97 139 Or by adding a trend line of linear type, thus yields the equation shown in Figure 3.1: y =- 0.056 x + 27.81 Obtaining the unit cost for 170 units project size = - 0.056 x 170 + 27.81 = LE18.29 Table 3.4: Locations cost indices Location City A City B City C City D City E Table 3.3: Cons Year 3 years ago 2 years ago 1 year ago Current year 140 Index 1.025 1.170 1.260 1.105 1.240 truction economic trends Index 358 359 367 378 Unitcots (LE) 27 ae 23 21 ww 17 15 2,250 1.485 2,467 2.730 S/S ]8|8/8 3,401 22.50 24.75, 20.56 18.20 fa fu fio fe 17.90 y- 0.056x + 27.91 So BD m mm os Ao Number of units aat 175200 3-Unit Method Thal) Jp le all San lly « andl Raby Sans ISAAC Glo ei yaad ib Ga Hayes) cities J Aga 9 gl dd aS oo GA clea! Sal Ge geal oe 8 fie lye Ai b Lgl le HH phil ode I gk Ls We AD Lead) Aezlall Od os 989) ctleall Aas AU pine GILSEI Gls prewell LS ge Lball Ga nly G5 Gh Geena peal Auulie ed 1) eo 981 Wal Ge gyS S22 MKD GJS of Key Cs 6 OS Je ye yl gh Gull JDL Other examples where unit costs may apply a * Schools — cost per pupil * Hospitals — cost per bed space. he ph be Riad pis US) oe Maite Nal 120 Gye Gi Se ea ped ML lS Gi yo ith Tye 90 lye Le al pt sae] a call 5 pune 4S 1200000 dat) The first step is to separate the per-pupil cost = LE1,200,000/120 = LE10,000/pupil Apply the unit cost to the new school = LE10,000/pupil X 90 pupils = LE900,000 al Js p88 Lin ally 435m 1.250.000 2m 100 Sane rites oli Mla AUIS G| Ul Mig get 125 coins dal Cost per-bed = LE1,250,000/100 = LE12,500/bed New hospital cost = LE12,500/bed X 125 bed = LE1,562,500 142 wai dhe oils gt Le 445s 3,000,000 eli! AG CaS « 5 jee SOO Quy yl pall onede gly aay $5 Jl 450 aad cl pall Cost per-car = LE3,000,000/500 = LE6,000/car New Garage cost = LE6,000/car X 450 car = LE2,270,000 4-Superficial method ay al be plated eat Gf ayy taal Ge Qe all all ISS Glo aaa yaad ay pb ga yl LSA SY ip all 4 5S Lay y praca Go GLY Ja all ge Ban gl Aya Ga hall ga US «ISS Any Hg ps Hl ae sits gael AlsLeall Floor Area Estimate = Area of each of the floors x Cost per m2 lens Gall oho pulls (5 shal ite Sys Se Gross floor area for office block=10.0 x 25.0 = 250.0 m2 Built in Area =250-(22.5*2)=205 m2 Area of 5 floors 205.0 x 5 = 1025.0 m2 1025.0 m2 x LE1100 /m2 = LE1,127,500.0 Basement 7.00 x 25.0 = 175.0 m2 x LE1300 /m2 = LE227,500.0 Estimate for block LE1,355,000.0 Ss! 26100 Sty 4200 inbee JST 533 oes 8 G4 GSE UH an ye pal Se hE Ass 4 Dll ode pent dal @+ 54 300=1004200 = USI Malad =Yy/ Ge Fall G¥52 1850 pbs Ayal all ey je all ASS G8 pall J gael Gay Total Cost = 1850x300=555,000 US 143 Convert to Riyal =555,000x3.64=2,020,200 3.00 s 3.00 3.00 3.00 3.00 3.00 7.50 Section 1 7.00 180! 144 aad) lst ysis Calale SOE (ye clit (é AML) GNSS ayaa iy monetary and productivity. AqlYl Al es il peal s eels gal LLal, AcLlls 5 yah) Vane: cgaitll Jalal dai yy ee He SN) Se linall cb aie cliall GG Mayer ASI (gail LaLa GU Se pas tes y La gall el sl Ge sual! ge Dhak « cil Upale Gy gla gill Jee ye de ite Ze pane col! 955 Ol cos ab cle A yall UglSLan ea CLUE Cale a yy Cony Laka AISRall la 35 teal Bihce 2 ya Lgild « Adan y Sains 6 Sal) gh Aslan Leal! (coll y BLY LI ally pga hl) Vane Sha) Aplun lay ALA Ua GlLaall allen Y) 4S Glee Ulan CNaee Gaaled oi yay algal) qa els Lal Jal Sel ji Yael! Glele g gene Mi jee AMLaall SlLeg Yl 4S Ge Mates ALtdall gail Total cost of labor = total work hour x wage rate 2 ie 14385. 20.97 2 p38 alah yal ado gis g sel) 8 ALI 6 «pull 8 Glee 10 Jens Gils eS fell Baaly Sy) cay Jaall gal ge gual [all Sc eg / Glebu 8 Aadinall Jaall Cig quan Gai ele gl} Canal ye 6 p gll G8 leks B Ge ap 38 gall Sle Lull een ile adall gis Esra cass asl ayy Ja US ie all ay 17.65, ela! Glacall dy pe = Aabedll 5 92! 30 13 Ay ue soy 145 AAISSI Lau gia Case! poled! al Ge dhe 100 SS 4m 12.5 elell aay yet ual Jane coi eS Chub gb de Lull dal! Gels 60 = 6 X 10 = Mail) CleLtl yl ell + ce gal) gala! all + cll sll (gle ge gu) a ll = adall Shela feos =5x8x145%2%15 410x275 dels ete aX Gobel he cull ado oy hell ja) gle Gail pall oy Belull / sis 26.21 = 45s 20.97 x (60/75) = delat jal Lau sin 2.01 = 0.0765 * 26.21 = elaa! Gluall Ay ye 0.79 = 0.03 x 26.21 = Abst Ay po 2.62 = 20.97 x 100 / 12.5 = Uap) Sell / 4 31,63 = dell au bu gia gt 2 By de wcupelasa ye Cully Gul yS BG ay Jae paaie lh gl ya sil Deal! DUSY (a2 / Glebe 8) aly 4558 bad aia! Jews AMY! AMSG a5 gh 4558.22.40 tb pS soles JS 4828.55 tl eS US 5 sal ane iUall all In this instance, the total cost of crew is calculated as follows: Total cost = 3x 3 x 8 x 28.55 +2 x 3x 8 x 22.4 =LE3131 3 ly te Man YN AAS g pgp /Sa0.9 175 gh Le LL ob ans gill AU co gl LY! ane GIS Li} Baa sll / ABS 100 55.5. 4.5 ce stl Deal Le 5OU) a gall Asks 1800 Go pull cof aflall Bam y 1400 eles lal! Lagh peieay cull alsa y 8 aul | Silos ld ine Gee py Sled i gaze fan ll AUS laa Gal 146 dail isha j Bay JS GUY) / Apes) = (Ade SH haa ll) Salt || abi! ase x = 1400/175 x 1=8 pul Haha j Samy JSD allel) 44185 x (Cal gl) Clan g) Sal = (Leal) 4alS5) AalSc) 482 14400 = ox: / 48> 1800 * pie 8 all 8 x es2/ Ade 100 X al gall Ge 5255 4.5 + Aus 14400 = 5 ptleall AalS tea) gnee elas 18000 AyaSA) / Agteapy) Adlsal) = daa git dats Saag / 4s 12.86 = 4s 1400 / 44218000 | lay Gals Baas | Lee Glee Gi cues pila } Ge etl obs Oba Ga Gd os! Je GIS JAS Go 5 200 Sy LYL Bal ga anf 2 AO cle Cathe reS cys pile plas | hy dele / Jo) 0.08 tel te Sal! Wala ele B= asl / Seal! lela sae 5 6 = 3 Catt eS! af) a. Duration = 200 / 40 = 5 days b, Total man-hours needed = 200 x 0.08 =160 man-hours (if one man used) Duration = 160 / 8 = 20 days (if one man used) Duration using 3 men = 20 / 3 = 6.6 days 147 Equipment costs cima! 4s ASL) GNSS fad Shaeally Aas yall CaS! SR GINS y ASLAM) apie gantsy Cslanall UALS - ig ASLal 2 sgh gle ASL) GIS ats RED GNSS Lats pall ANS y paca g ADGA) GNSS y (Leki) J pill Cals spill GNSS 5 258 gly gy JAN GIS y CLAY y heal y A gy) dats; Yui Slam Gye Malad el 20 4 lla! Allen Y) AWS a 4,91 Aalst ia yp ADeatasll Canal yess gl qeaall gb pal ye cy g6th « ple JEy ISA y DEAN G8 Saas Genilly Gall pp yy Slane dy pay Malay) lanall gat) ISS las 4S Pel pAll ue dayad Gans Ald « Cilanall (LARLY 4S I) pall 465 Lue al ye Bonga yy gh SIP UY Lady ee OSs « UTLall aba G8 5 Sloeall GolBY! yell Glue! GYsLel vases pldiub 4 sy Bae yall Cie gioall ya ALLS il gi aed 5 pn lla a Ge jae | pl oy guclls 4 yall ALLeaS Gloeall cali) peel] GLuad as 2 tia sq REY pecll 0 Cal pis 0 Ses dn Gill 40 S8iiall pied s dle GIGGO lis el yd ee CSIs IS) aad 1a CL yal Ay gis) Adi og Hdl Ga 15 Baill) Jone dats P = 460,000; F = 40,000; n = 10; i= a8 yall del G8 Ga ll Annual cost of finance = LE47,684/year 1as Shane DAY Gs Ghul 5 pall Ga Me pas day Straight-Line method 446:¥ 5) 85 he DG gee Cua oh oi Ma all ode dy Main dd USL Gye Getly dana Gad ches, tat ANA Ahead Go dhe gl id Lashed DY! pyeey (Annual depreciation charge) Dn = (P-F) /N Dr SDS pies gill len Yl alia F Jal dag Nc ginal CatBYT saat Peel pill jen alt She Kassel ¢ Agi GOOD pias B aay All aiady din LallGQ Clanall aa! ol pd pau IS 1 SS cilanall 4 sitll Lal y 5 yl AD! P = 60,000; 6,000; N = 8; = LES4,0006000 — 60000 = “>gi4I alles! = LE6,7508 / 54000 = os sitll DY! cole US catBY) yaad Ags ob NY) Ya cg gla Colancall ysl all Gf Lae Year Annual depreciation Book value 0 0 60000 1 6,750 53,250 2 6750 46,500 3 6,750 39,750 4 6,750 33,000 5 6750 26,250 6 6750 19,500 7 6750 12,750 8 6750 6,000 Slaeall HEY! Glas! Gyles Lass aay ag 1-Sum-of-years digits method 2-Sinking fund method ((+i"-1) on (l+i)"-1 P aw) ( : ] Anmual cost of finance = 4 ia EF tata) Fl ap Annuakos of finance: | 460002115" C15) Annual cost of finance = LE47,684/yeat das went Je Galvanize Steel Cable tray 1.5 JAS yn 3 24100 Gatlls p+ 400 Unlie sin 100 Als Ae a gas EAS) jul SS alan pig yh 13a Web pe a Sa SS CIS BN gg ME pal Lage gg pall Sesbe Sel $- all si be Laval Gel Gs TENDERS Uaes cod GY Item SCOPE OF WORK Be! 8-2 REPLAY FOR CLARRIFICATION 48 (9825 “tlds Le ag] Jes si SI ce OY gy ball GALA LSA Lp Gall CAS 58) ale [iy VENDOR LIST [itis -3 Upbesley lisa gill dans gi ES (5 peg eel GB ty age (ot Sl ll ae AMG Sl p80) ELS) Gye Md dagen diy gles yan » gl aS 1 Choose the Right Work to Bid 2-Review the Specifications 3-Review the Drawings 150 4-Perform a Quantity Takeoff 5-Request Supplier Quotes 6-Create your Estimate 7-Add Overhead and Profit 8-Build your Proposal 9-Double Check Takeoff Quantities & Estimate 10-Submit Bid Cyl pee gee 1 JAAS al yall =i Cable Tray Length by PCs=42 Nos L=2.44M Steel Cover Cable Tray PCs=42 Nos No Of Cable Tray Joint =92 Nos Earthing Wire 4 mm =92 Nos Carriage Bolt with Fisher and Nut 1/4 x 1/2=1472 Nos Slotted Channel, Hot dip galvanized,41mm x 41mm by Length 3 Mtr =11 length Threaded Rod, 10mm 3 Mtr =50 Length Steel Fisher =134 Nos Spring Washer 6 mm =134 Nos Washer and Nut 6 mm =402 Nos A pS ULSI CS Line pa AL S150 al pelt LS 00 sts DISD ill ae 8 A aS a the Sp SIH1504100= ile & pana 2 945 + Up A SI ph IS pin a al Jey 16979 808 5S 454+ CONSUMABLE ( S%OF MATERIAL COST) 1171 al 8 He IEDM OY GS col Led GI Parking ge Gtseaitadl JVI gi Saal ge Gl main roof, Sie 3 ied UI DYN 95 gd Dell OS one gD pas aabla allen any chan Goel 2 So MA yal sola oh 6 SIS 6 AI SVL sls SI gual gta 4S Ua Jaa gb glia ape Casein 2 go Gn eS 2 pst Daal nj ale 7; Isis las Sp. D=QyP.Rx No of Crew D Bunt isan Q ws PAR soll ell A all Jane 151 No of Crew sols pl pa! axe ia AO aa gl gb pal Janay al gl 4 anes jhe 100 ApS Lite Galil JES. D=100/40x1=2.5 Days ea 200+ a2 gi ey 1800 eth Ae 4S ape Sy ela he SD ISS GG a5 Le Sey 8.95=8/30/2 150= NS 5 +d! go 150+ pla scLall od Jy 15 G8 Average aslia of pb] Sy child, aS) Aca Lyasip hp ally Thy 12 sebally Total cost=No. of labors x daily working hours x No. of days 2x2.5x8x15=600 SR cuts SI al 1) 2x2.5x8x12=480 SR= oyieluall Ailss y Jey 1080=480+600= ¢ st! 50) allel pe Cina 4.9% Tools Wastage 54 Sey 1134=54+1080 = dae Lg sana vals Forman ( for 4 team leaders)=5000 J team leader ( for 6 workers)=2200 Jes worker =1800 oy Cost /Group /month =12450 Jy Cost /Group /day =12450/26=479 Jus Total cost for 2.5 days =2.5x479=1197 SR PS Uebnin AS le 3a AS 2 ely oh Jl al ay OVER HEAD AND PROFIT Whiai Wi yes alld a SAT 4S yb ye Glia oy Site Over head+General Over head=15%cSils, Profit + Risk =15%cell cS Total 15%+15%=30 % 10% x (16979+1134)=5433 SR 33+ 18113=23546 SR For 1 Meter =23556/100=235 SR 152 Pro-rata 4 yb plsdiul » si Gla) uaa Pro-rata?4i yb 4) sins YAN jane 600X100 Lule GLeSll J sloe 4 CABLE TRAY sl NS 2s aa Ab sPro-rata plaSiuh ¢ sid Shy V+ pe 100 eldey ly V+ 9G pe 200 nliley De Sky 2300 «e400 gh si DAS SES. sSia ie gli Gulia gl pe Lee Sa y Sky V8 pe £06 Say VAG patos Gy jSs8 chal pall Cad PRICE AlN) 4 1 (t,-1) 153

You might also like