You are on page 1of 4
14-O9T.' O5 (MAR) 09:45 . Manual For PALL ROCHE Water Desalination Unit ROCHE NARINE GE PAX: +#39010543257 Pool 561-2 ACTUATOR Main Components 24 23 } 22 2 a 2 eh 3 1 4 = Part No. Description = 2 4 Cover > 8 2 Capacitor 5 ” 3 Motor s—t Ee 4 O-Ring 7 5 Gears i 6 Hand Wheel e 20 7 Pressure Spring 9———__+ 8 Uncoupling Lever 9 O-Ring 8 10 Wiping Ring 10: W Antl-Rotation Flange 12 Threaded Bushing 15, 13 Scale u 4 14 Scale Clamp a 15 Support d T 16 Intermediate Flange 17 Cable Bushing z 18 Gasket Seal re 19 Torque Switches Fig 1 20 Actuator Spindle 5 21 Terminal Strips 22 Switching & Signalling Device 23 Gasket “a 24 Cap Nut Fig 2 7100-92-0398 Thi 14-097,“ O5 (MAR) 09:46 ROCHEM MARINE GE PAX: ++39010545257 P, 002 Menuai For PALL ROCHE Water Desalination Unit 861-3 ACTUATOR ie a Tei Manual ControlofValve sis os Tet ghee | This valve can be manually operated by : “A” The Uncoupling Lever and "B" The Hand Wheel. » To open or close the valve pull down the uncoupling lever to dis-engage the motor drive and turn the hand wheel The lever is spring loaded and will re-engage when released Turn hand wheel Clockwise to Close. Anti clockwise to Open Aes Power Supply and Controls For units controlled by a A020-Plus processor, the diagram below shows the inter conneetions between the control panel ‘and the actuator, For Units controlled by other processors see the electrical schematics for the correct cabinet terminal connections. a | | 7020. PLUS CONTROL CABINET TERMINAL CONNECTION BOARD | NI 4 [al 154] 74175 | | 220v | | cuosms OPEN iil er soso | (t[2lel4islel7 ele lio vilaalta|14] 15] 16 [17] 18] 19 20 24 [22] 28 alas) | A l | pl . yl DE DE We WE st 82 34 85 \ MOTOR CONTROL VALVE ACTUATOR 7400-32-0388 14-017. 05 (MAR) 09:46 ROCHEM MARINE GE PAX:++39010845257 P.005 Manual For PALL R@GHEA Water Desalination Unit 61-4 ACTUATOR [ Controls There are 4 limit switches fitted in this actuator DES1 DE S2 WE S4 WE S5 This iasafety | Thisisasefety | This is an indicator switch | This ie an indicator witch to prevent | switch to prevent | to signal the Ad20 switch to signal the Sver torque on | over torque on _| processor of the valve ‘A020 processor of opening closing position (open) the valve position | (closed) [Torque Switches DE S1_and DE S2 The 2 torque switches S1 and $2 shown in this photograhph must not be adjusted as they are “Factory Set’. Way Switches WE S4 and WE S5 To prevent the forque switches S1 and S2 deing activated the way switches $4 and S5 are always set between the settings of Stand S2. Checking or re-setting the position ‘of switches S4 and SS should be carried out es follows: Switch off power to the R.O. Unit. Remove the nut gaskat,cover and gasket seal, Items 24,23,1 and 18. 4st check /set the OPEN switch S4 Engage the manual control by pressing down the uncoupling lever. Tum the hand wheel ANTI-CLOCKWISE to open the valve When resistance is felt stop turning the handwhee! Use the valve postion pointer and mark the spindle position on the Scale plate. Re-engage the manual control and turn the hand wheel CLOCKWISE intl the pointer hes moved towards the closed position by 1mm. ONOARYNS 7100-32-0398 14-077. ' 05 (MAR| 09:47 ROCHEM MARINE GE PAX:+#39010545257 7.0 5 04 Manual For PALL ROCHEM Water Desalination Unit 561-5 ACTUATOR Way Switches WE S4 and WE S5. 3 Gee below for correct position of the cams on the inner switch. Cam position for the valve to be full open. 40. Adjust the cams as follows: Oa. Free the lock nut on the shaft, do not take it off 406, Slacken the milled nut to allow the cams to move. {Oe Position the cams for the inner switch as shown below and hand tighten the milled nut. 44, Re-engage the manual contro} and turn the hand wheel CLOCKWISE until resistance is felt then stop. | 42. Use the valve postion pointer and mark the spindle position on the Scale plate. 43. Re-engage the manual control and turn the hand wheel ANTI-CLOCKWISE unt! the pointer has moved towards the open positicn by (mm. 44, Hold the inner cams in their pre-set position while vary carefully releaseing the milled nut and position the cams on the outer switch. Tighten the milled nut when the cams are as shown below. Cam position for the valve to be closed. 15. Secure the cam assembly by tightening the Jock nut. 46, Way switches $4 and $5 are now correctly set. Stroxe Adjuster and Way Switches WE S84 and WE $5 Stroke Adjuster 4. - Limit Switch ta- Valve Open ‘Switch 4b- Valve Closed Switch 2 - Milled Nut 3 - Cam Plate 4 - Potentiometer 5 - Position Scale 8 - Adjustment lever system 7 -Locknut WE S4 {inner switch) in switched OPEN position WE $8 (outer switch) In switched CLOSED position ‘rann-92.0398

You might also like