Professional Documents
Culture Documents
General catalog
Single, double & triple zp15
Parker Hannifin
2 Denison Vane Pump Division
Vierzon - France
VANE PUMPS - GENERAL CATALOG
T67DCC Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
T67DDCS Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Parker Hannifin
3 Denison Vane Pump Division
Vierzon - France
CARACTERISTICS - GENERAL CATALOG
CHARACTERISTICS These vane pumps have been specially designed for high/low circuit. The combination
of different cartridges in double and triple pumps allows low flow at high pressure
(300 bar max.) and high flow at lower pressure. This is a clever way to optimize your
circuit design.
This pump feature will also allow a very fast pressure cycle change with a very pre-
cise flow repeatability.
HIGHER PRESSURE B : 4650 PSI max. (4350 PSI for multiple pump).
C : 4000 PSI max.
D : 4060 PSI max. (3500 PSI for multiple pump).
E : 3500 PSI max.
BETTER EFFICIENCY Over 94 % under high pressure, which increases productivity and reduces heating and
operation costs.
CARTRIDGE DESIGN Provides for drop-in assemblies. They permit easy conversion and service.
B and D cartridges : bi-directional
C and E cartridges : Uni-directional.
WIDE RANGE OF ACCEPTABLE Viscosities from 3900 to 60 SUS permit colder starts and hotter running. The balanced
VISCOSITIES design compensates for wear and temperature changes. At high viscosity or cold tem-
perature, the rotor to side plates gap is well lubricated and improves mechanical effi-
ciency.
FIRE RESISTANT FLUIDS AND Including phosphate esters, organic esters, chlorinated hydrocarbons, water glycols,
BIODEGRADABLE FLUIDS rapeseed may be pumped at higher pressures and with longer service life by these
pumps.
GENERAL APPLICATIONS 1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rota-
INSTRUCTIONS tion.
2. Check inlet conditions of the pump, if it can accept application requirement.
3. Type of shaft : if would support operating torque.
4. Coupling must be chosen to minimize pump shaft load (weight, misalignment).
5. Filtration : must be adequate for lowest contamination level.
6. Environment of pump : to avoid noise reflection, pollution and shocks.
Parker Hannifin
4 Denison Vane Pump Division
Vierzon - France
SINGLE PUMPS : SPEEDS, PRESSURE RATINGS - GENERAL CATALOG
Parker Hannifin
5 Denison Vane Pump Division
Vierzon - France
DOUBLE AND TRIPLE PUMPS : SPEEDS, PRESSURE RATINGS - GENERAL CATALOG
For further information or if the performance characteristics outlined above do not meet your own particular requirements, please consult
your local DENISON Hydraulics office.
Parker Hannifin
6 Denison Vane Pump Division
Vierzon - France
MINIMUM ALLOWABLE INLET PRESSURE (PSI ABSOLUTE) - GENERAL CATALOG
Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 60 and 300 SUS. The difference
between inlet pressure at the pump flange and atmospheric pressure must not exceed 2.9 PSI to prevent aeration.
Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids.
by 1,35 for HF-5 fluid.
by 1,10 for ester or rapeseed base.
Use the cartridge with the highest absolute pressure for double and triple pumps.
Parker Hannifin
7 Denison Vane Pump Division
Vierzon - France
PUMP SELECTION - GENERAL CATALOG
Routine : Example :
231 Q 231 x 19.8
1. First calculation Vi = n Vi = = 1.83 in3/rev.
2500
4. Find qvs leakage function of pressure T7B (page 14) : qVs = .79 GPM at
qVs = f(p) on curve at 60 or 115 SUS 3600 PSI, 115 SUS
5. Available flow qVe = qVi - qVs qVe = 20.78 - .79 = 19.99 GPM
Vi = 1.92 in3/rev.
)
9. Results
qVe = 19.99 GPM T7B B10
P = 44.84 HP
INTERMITTENT PRESSURE T7 and T67 units may be operated intermittently at pressures higher than the recom-
RATING mended continuous rating when the time weighted average of pressure is less than or
equal to the continuous duty pressure rating. This intermittent pressure rating calcula-
tion is only valid if other parameters : speed, fluid, viscosity and contamination level
are respected.
5000 For total cycle time longer than 15 minutes, please consult your DENISON Hydraulics
representative.
4000
Average Pressure
Example : T7B - B10
Pressure (psi)
3067
3000
Duty cycle 4 min. at 4650 PSI
2000 Cycle 1 min. at 500 PSI
1000 5 min. at 2300 PSI
0 (4 X 4650) + (1 x 500) + (5 x 2300) = 3070 PSI
0 5 10 10
Tim e (m inutes)
3070 PSI is lower than 4200 PSI allowed as continuous pressure for T7B - B10 with
HF-0 fluid.
Parker Hannifin
8 Denison Vane Pump Division
Vierzon - France
DESCRIPTION - GENERAL CATALOG
Shaft end outlet port has 4- Cap end outlet port has8-positions
positions at 90° intervals at 45° intervals relative to inlet on
relative to inlet. Inlet each double and triple pump.
Inlet Outlet
Front & rear sideplates are
each clamped axialy by the
separate discharge pressures.
Section B-B
Pin cavity is at a steady
pressure equal to that at
discharge port. A
B Discharge ramp
Side feed holes supply discharge where unloaded
Section A-A vane moves in.. Working vane on minor arc
pressure to pin cavities. seals discharge pressure from
the suction port.
APPLICATION ADVANTAGES z The high pressure capability up to 4650 PSI, in the small envelope, reduces installa-
tion costs and provides extended life at reduced pressure.
z The high volumetric efficiency, typically better than 94%, reduces heat generation,
and allows speeds down to 600 RPM at full pressure.
z The high mechanical efficiency, typically better than 94%, reduces energy con-
sumption.
z The wide speed range (600 RPM at 3600 RPM), combined with large size cartridge
displacements will optimize operation for the lowest noise level in the smallest
envelope
z The low speed (600 RPM), low pressure, high viscosity (3900 SUS) allows applica-
tion in cold environment with a minimum energy consumption and without risk of
seizure.
z The low ripple pressure (± 29 PSI) reduces piping noise and increases lifetime of
other components in the circuit.
z The high resistance to particle contamination, because of the double lip vane,
increases pump life.
z The large variety of options (cam displacement, shaft, porting) allows customized
installation.
Parker Hannifin
9 Denison Vane Pump Division
Vierzon - France
START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG
GENERAL : All DENISON Hydraulics vane pumps & motors are individually tested to provide
the best quality & reliability. Modifications, conversions & repairs can only be done
by authorized dealers or OEM to avoid invalidation of the guarantee.
The pumps & motors are to be used in the design limits indicated in all the sales bul-
letins. Please contact DENISON when tresspassing the catalog limits.
Do not modify or work on the pump (or motor) under pressure or when the electric
motor (or any drive) is on.
Qualified personnel is required to assemble and set-up hydraulic devices.
Always conform yourself to the valid regulations (safety, electrical, environment...).
The following instructions are important to follow to obtain a good service life time
from the unit.
ROTATION & PORTS INDICATION The rotation and ports orientation are viewed from the shaft end.
CW stands for clockwise, right-hand rotation.
CCW stands for counter-clockwise, left-hand rotation.
START-UP CHECK-UP Check that the assembly of the power unit is correct :
The distance between the suction pipe & the return lines in the tank should be at its
maximum.
A bevel on both suction & return lines is recommended to increase the surface and
so lower the velocity. We suggest a 45° minimum angle.
Velocities : inlet 1,64 < x < 6,23 ft per sec.
: return x < 19,7 ft per sec.
: Always insure that all return and suction lines are under the oil level to
avoid forming aeration or vortex effect. This should be done under the
most critical situation (all cylinders extended for example). Straight and
short pipes are the best.
Q (GPM)
V= = ft/s
3.12 x π x r2 (in)
The size of the air filter should be 3 times greater than the max. instant return flow
(all cylinders in movement for example).
If the pump is in the tank, please choose the NOP option (no paint) and use a short
inlet pipe.
DENISON does not recommend inlet strainers. If needed, a 100 mesh (149 microns)
is the finest mesh recommended.
A coaxial drive is recommended. For any other type of drives, please contact DENI-
SON.
Make sure that all protective plugs & covers have been removed.
Check the pump rotation versus the E-motor or engine rotation.
Start-up :
The tank has been filled up with a clean fluid in proper conditions.
Flushing the system with an external pump prior to the start-up is good.
To allow a good priming of the pump, the air should be bled off.
The first valve on the circuit should be open to tank.
Air bleed off valves are available on the market place.
It is possible to bleed off the air by creating a leak in the P port of the pump.
Warning : this has to be done in low pressure mode as it could create a danger-
ous fluid leak. Make sure that the pressure cannot rise (open center valve to
tank, pressure relief valve unloaded ...).
When oil free of air appears, tighten the connectors to the correct torque.
Parker Hannifin
10 Denison Vane Pump Division
Vierzon - France
START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG
The pump should prime within a few seconds. If not, please read the troubleshooting
guide (1 - EN0721 - *).
If the pump is noisy, please troubleshoot the system.
Never operate the pump at top speed and pressure without checking the completion of
pump priming.
SHAFT & COUPLING DATA :
COUPLINGS AND FEMALE The mating female spline should be free to float and find its own center. If both
SPLINES members are rigidly supported, they must be aligned within 0.006” TIR or less to
reduce fretting. The angular alignment of two splines axes must be less than ± 0.002”
per 1” radius.
The coupling spline must be lubricated with a lithium molydisulfide grease, disulfide
of molybdenum or a similar lubricant.
The coupling must be hardened to a hardness between 29 and 45 HRC.
The female spline must be made to conform to the Class 1 fit as described in SAE-
J498b (1971). This is described as a Flat Root Side Fit.
KEYED SHAFTS DENISON Hydraulics supplies the T6 series keyed shaft pumps with high strength
heat-treated keys. Therefore, when installing or replacing these pumps, the heat-treated
keys must be used in order to ensure maximum life in the application. If the key is
replaced, it must be a heat-treated key between 27 and 34 R.C. hardness. The corners
of the keys must be chamfered by 0.03 to 0.04 at 45° to clear the radii in the key way.
The alignment of keyed shafts must be within tolerances given for splined shafts here
above.
SHAFT LOADS These products are primarily designed for coaxial drives which do not impose axial or
side loading on the shaft. Contact DENISON for specific applications.
SPECIFIC POINTS :
MINIMUM INLET PRESSURE Please read the charts in the sales leaflets as the minimum requested inlet pressure
varies versus the displacement and the speed.
Never go under 11.6 PSI Absolute (-2.9 PSI G).
MAXIMUM INLET PRESSURE It is recommended to always have at least 22 PSI differential between inlet and outlet.
Standard shaft seals are limited to 10 PSI G but some allow 100 PSI G. Please contact
DENISON for more information.
MINIMUM OUTLET PRESSURE It is recommended to always have at least 22 PSI differential between inlet and outlet.
VERTICAL MOUNT When assembled vertically, always be careful to prevent any air from being trapped in
the pump (behind the shaft seal for example).
FLUIDS :
DENISON CLASSIFICATIONS Type of fluids : For all types of fluids, DENISON’s products have different pressures,
speeds & temperature limits. Please refer to the sales leaflets.
HF-0 = Anti-wear petroleum base.
HF-1 = Non anti-wear petroleum base.
HF-2 = Anti-wear petroleum base.
HF-3 = Water-in-oil invert emulsions.
HF-4 = Water glycol solutions.
HF-5 = Synthetic fluids.
Parker Hannifin
11 Denison Vane Pump Division
Vierzon - France
START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG
ACCEPTABLE ALTERNATE FLUIDS The use of fluids other than petroleum based antiwear R & O fluids requires that the
maximum ratings of the pumps will be reduced. In some cases the minimum replenish-
ment pressures must be increased. Consult specific sections for more details (page 11).
Indutrial
VISCOSITY Max. (cold start, low speed & pressure) 3900 SUS
Max. (full speed & pressure) 500 SUS
Optimum (max. life) 140 SUS
Min. (full speed & pressure for
HF-1, HF-3, HF-4 & HF-5 fluids) 90 SUS
Min. (full speed & pressure for
HF-0 & HF-2 fluids) 60 SUS
VISCOSITY INDEX 90 min. Higher values extend the range of operating temperatures.
TEMPERATURES The usual limitating factor of temperature (low or high) comes from the obtained vis-
cosity. The seals are sometimes the limit : standard seals range from -9.4° F to 194° F.
Maximum fluid temperature (θ) °F
HF-0, HF-1, HF-2 + 212
HF-3, HF-4 + 122
HF-5 + 158
Biodegradable fluids (esters & rapeseed base) + 149
Minimum fluid temperature (θ) (also depend on max. viscosity) °F
HF-0, HF-1, HF-2, HF-5 - 0.4
HF-3, HF-4 + 50
Biodegradable fluids (esters & rapeseed base) - 0.4
Over or under these values, please contact DENISON.
WATER CONTAMINATION IN THE Maximum acceptable content of water :
FLUID 0,10 % for mineral base fluids.
0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.
If the amount of water is higher, then it should be drained off the circuit.
Fluid motor speed rpm 231 x flow rate (U.S. gpm) x volumetric eff.
displacement (in3/rev.)
Fluid motor torque lbs. in pressure (PSI) x displacement (in3/rev) x mech. eff.
2π
Parker Hannifin
12 Denison Vane Pump Division
Vierzon - France
GENERAL CHARACTERISTICS - GENERAL CATALOG
GENERAL CHARACTERISTICS
Weight without Moment of SAE 4 bolts
Mounting
connector and inertia J518 - ISO/DIS 6162-1
standard
bracket - Lbs Lb.in2 Suction Pressure
ISO 3019-2
T7B
100 A2 HW
50.7 1.1 1"1/2 1" or 3/4"
SAE J744
T7BS
SAE B
SAE J744
T6C 34.6 2.6 1"1/2 1"
SAE B
ISO 3019-2
T7D
125 A2 HW
57.3 6.7 2" 1"1/4
SAE J744
T7DS
SAE C
ISO 3019-2
T7E
125 A2 HW
95.4 21.3 3" 1"1/2
SAE J744
T7ES
SAE C
P1 P2
ISO 3019-2
T7BB
100 A2 HW
71.9 2.3 2"1/2 1" or 3/4" 3/4"
SAE J744
T7BBS
SAE B
SAE J744
T6CC 57.3 5.8 2"1/2 or 3" 1" 1" or 3/4"
SAE B
SAE J744
T67CB 57.3 3.9 2"1/2 1" 3/4"
SAE B
ISO 3019-2
T7DB
125 A2 HW
85.1 9.0 3" 1"1/4 1" or 3/4"
SAE J744
T7DBS
SAE C
SAE J744
T67DC 85.1 9.0 3" 1"1/4 1" or 3/4"
SAE C
ISO 3019-2
T7DD
125 B4 HW
123.4 12.4 4" 1"1/4 1"1/4
SAE J744
T7DDS
SAE C
ISO 3019-2
T7EB
125 A2 HW
121.2 22.5 3"1/2 1"1/2 3/4"
SAE J744
T7EBS
SAE C
SAE J744
T67EC 121.2 24.2 3"1/2 1"1/2 1"
SAE C
ISO 3019-2
T7ED
125 A2 HW
145.5 27.2 4" 1"1/2 1"1/4
SAE J744
T7EDS
SAE C
ISO 3019-2
T7EE
250 B4 HW
209.4 33.2 4" 1"1/2 1"1/2
SAE J744
T7EES
SAE E
P1 P2 P3
T67DBB 8.9
SAE J744 3/4"
T67DCB 134.5 10.1 4" 1"1/4 1"
SAE C
T67DCC 11.4 1" or 3/4"
ISO 3019-2
T7DDB
125 B4 HW
145.5 13.5 4" 1"1/4 1"1/4 1" or 3/4"
SAE J744
T7DDBS
SAE C
SAE J744
T67DDCS 145.5 14.7 4" 1"1/4 1"1/4 1" or 3/4"
SAE C
ISO 3019-2
T7EDB
250 B4 HW
224.9 26.1 4" 1"1/2 1"1/4 1" or 3/4"
SAE J744
T7EDBS
SAE E
ISO 3019-2
T67EDC
250 B4 HW
224.9 27.4 4" 1"1/2 1"1/4 1" or 3/4"
SAE J744
T67EDCS
SAE E
Parker Hannifin
13 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7B - T7BS SERIES
115 SUS
nn == 1200
Série11200RPM
RPM
60 SUS nn == 1800
Série21800RPM
RPM
1,5
υu == 150
150SUSSUS
60 Lw
Lw == Lp
Lp ++88db
db(A)
(A)
55
0,5
0 50
0 500 1000 1500 2000 2500 3000 3500 4000 4500 0 500 1000 1500 2000 2500 3000 3500 4000 4500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or
viscosity if internal leakage is more than 50% of theoretical flow.
2,5 Fa
Load F [Lbs]
200
Shaft keyed N°1
2
150
1,5
100
1
50
0,5
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 600 1200 1800 2400 3000 3600
Pressure p [PSI] Speed n [RPM]
Parker Hannifin
14 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 50.7 Lbs - T7B AND T7BS SERIES
.39 1.60
1.41 .31 1.80
B - 4 HOLES C .31
.96
.70
1.57 KEY .315 x .276 .96
.06 x 45°
.06 x 45°
3.936 DIA
S P
2.76
3.937
D
1.38
1.111 MAX
.982 DIA
.06 x 45°
.987
.08 x 45°
SHAF
SHAFTT CODE 2 SHAF
SHAFTT CODE 3 SHAFT CODE 4
(KEYED ISO R775) SAE B INVOLUTE SPLINE DATA SAE BB INVOLUTE SPLINE DATA
1.50 DIA SUCTION E DIA PRESSURE CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
.35
J498b - PITCH 16/32 J498b - PITCH 16/32
13 TEETH - 30° PRESSURE ANGLE 15 TEETH - 30° PRESSURE ANGLE
T7B SERIE
(FLANGE ISO 3019/2 100A2HW)
H DIA
3.998 DIA
2.02 DIA
C.G.
4.000
.982 MAX
.874 DIA
.05 x 45°
T
T7BS
BS SE
SERI
RIE
(FLANGE SAE "B")
T7BS T7B
00 01 M0 M1
A DIA 3/8 16 UNC x .75 deep M10 x .75 deep
B DIA 1/2 13 UNC x .88 deep M12 x .88 deep Shaft torque limits [in3/rev. x PSI]
C 1.03 .87 1.03 .87
Shaft Vi x p max.
D 2.06 1.87 2.06 1.87
E DIA 1.00 .75 1.00 .75 1 14615
F 5.75 5.51 2 18246
G 2.87 2.75 3 18246
H DIA .56 .55 4 18246
Parker Hannifin
15 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T6C SERIES
5 nSérie1
==1200
1200RPM
RPM
60 SUS
nSérie2
==1800
1800RPM
RPM
70 υ
u ==150
170SUS
SUS
4 Lw
Lw = Lp++88dbdb(A)
= Lp (A)
3 65
2
60
1
0 55
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or
viscosity if internal leakage is more than 50% of theoretical flow.
Fa
Load F [Lbs]
3
Shaft keyed N°1
150
2,5
2
100
1,5
1 50
0,5
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200 2600
Parker Hannifin
16 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 34.6 Lbs - T6C SERIES
S P
2.76
2.06
1.03
1.38
.966 MAX
.06 x 45°
.874 DIA
.875
SHAF
SHAFTT CODE 2 SHAF
SHAFTT CODE 3 SHAF
SHAFTT CODE 4
1.50 DIA SUCTION 1.00 DIA PRESSURE (Keyed no SAE) SAE B INVOLUTE SPLINE DATA SAE BB INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 16/32 J498b - PITCH 16/32
13 TEETH - 30° PRESSURE ANGLE 15 TEETH - 30° PRESSURE ANGLE
MOUNTING TORQUE 117 ft.lbs
6.87
6.36 2.81 5.75
3.24 1.50 2.87
.38 1.50
.31
.25 MAX
KEY .250
.248
3.00
3.998 DIA
5.31
2.02 DIA
C.G.
4.000
2.98
.982 MAX
M8 x .63 DEEP
.874 DIA
.06 x 45°
.875
.56 DIA
.05 x 45°
SHAF
SHAFTT CODE 1
(Keyed SAE B )
Parker Hannifin
17 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7D - T7DS SERIES
P = Pressure port
S S = Suction port
75 nnSérie2
==1800
1800RPM
RPM
6
υu ==150
150SUS
SUS
5
Lw = Lp + 8 db (A)
Lw = Lp + 8 db (A)
70
4
3 65
2
60
1
0 55
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500 4000
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or
viscosity if internal leakage is more than 50% of theoretical flow.
6 Fa
300
Load F [Lbs]
100
1
0 50
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Parker Hannifin
18 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 57.3 Lbs - T7D AND T7DS SERIES
3.44
.354
.09 x 45°
.09 x 45°
1.53
1.16
4.919 DIA
2.31
2.53 DIA
S P
3.06
4.921
.09 x 45°
1.389 MAX
1.260 DIA
1.261
SHAF
SHAFT CODE
DE 3 SHAFT
SH TCCODE
DE 4
SHAF
SHAFT CODE
DE 5
2.00 DIA SUCTION 1.25 DIA PRESSURE SAE C INVOLUTE SPLINE DATA SAE C Spc (*) INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
(Keyed ISO R775) J498b - PITCH 12/24 J498b - PITCH 12/24
.31
14 THEETH- 30° PRESSURE ANGLE 14 THEETH- 30° PRESSURE ANGLE
7.28 3.29
T7DS
T7
3.44 1.50 .50 8.36
.31 C
.25 MAXI 1.94 D
KEY .313
.311
M10 x .79 DEEP
3.25
6.17
4.998 DIA
2.53 DIA
C.G.
5.000
E DIA
1.389 MAX
3.00
1.248 DIA
.09 x 45°
1.250
SHAFT
SH AFT C
CODE
DE 1
( Keyed SAE C ) 5.80
MOUNTING TORQUE 138 ft.lbs
2.88
.09 x 45° 00 M0 Y0 1) M0
1.250
Parker Hannifin
19 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7E - T7ES SERIES
n ==1200
nSérie1 1200 RPM
RPM
60 SUS
7 n ==1800
nSérie2 1800 RPM
RPM
uυ ==150150
SUSSUS
6 75 Lw ==Lp
Lw Lp++8 8
dbdb
(A)(A)
3 70
0 65
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or
viscosity if internal leakage is more than 50% of theoretical flow.
6
550
Fa
Load F [Lbs]
Parker Hannifin
20 Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 95.4 Lbs - T7E - T7ES SERIES
1.22 .70
T7E
T7 2.20 2.45
1.50 1.24
KEY .394 x .315
1.38
S DIA
S P
4.19
2.75
1.626 MAX
1.496 DIA
1.497
.09 x 45°
e x 45°
SHAFT COD
CODE 5 SHAFT CODE 3 SHAFT CO
CODE
DE 4
2.95 DIA SUCTION 1.50 DIA PRESSURE SAE CC INVOLUTE SPLINE DATA
( Keyed ISO/R775 - G38M) SAE C INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
MOUNTING TORQUE 138 ft.lbs 14 TEETH - 30° PRESSURE ANGLE 17 TEETH - 30° PRESSURE ANGLE
8.87 3.58 8.39
K
4.33 2.06
.31
W
2.00
T7ES
T7 ES K/2 5.81 DIA
.25 MAXI
KEY .375
.373
M10 x .79 DEEP
3.88
d DIA
1.668 MAX
1.498 DIA
3.00 DIA
C.G.
S DIA
7.38
1.500
.09 x 45°
4.01
e x 45°
SH
SHAFT
AFT C
CODE
DE 1
( Keyed SAE C-C )
2.44
.31
1.50
KEY .313
.311
-
3 54207
1.248 DIA
.09 x 45°
4 54207
1.250
5 48273
SH
SHAFT
AFT C
CODE
DE 2 Alternate mounting flange
( Keyed no SAE ) S DIA
Series e x 45° W K d DIA
Max. Min.
T7E 4.921 4.919 .079 .374 7.087 .709
T7ES 5.000 4.998 .051 .500 7.126 .689
Parker Hannifin
21 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7BB - T7BBS SERIES
115 SUS
nn ==1200
Série1 1200
RPM RPM
60 SUS Série2
nn ==1800
1800
RPM RPM
1,5
uυ ==150150
SUSSUS
65 Lw ==Lp
Lw Lp++8 8dbdb
(A)(A)
P1-P2
1
P1-P2
60
0,5
0 55
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500 4000 4500
Fa
2,5 P1-P2
Load F [Lbs]
0 50
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200 2600
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 180 Lbs
its operating conditions.
Parker Hannifin
22 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 71.9 Lbs - T7BB AND T7BBS SERIES
T7BB SERIE
A - 4 HOLES (FLANGE ISO 3019/2 100A2HW)
A - 4 HOLES G DIA
B - 4 HOLES .50 2.76
2.00 .39
.87 C 1.57
1.00
KEY .315 x .276
M
M M
3.936 DIA
P2 S P1
1.87
6.87
3.937
D
F
3.50
.9840 DIA
1.111 MAX
1.75
.06 x 45°
.9845
G
.08 x 45°
S
SHAF
AFTT CODE 5
.75 DIA PRESSURE (KEYED ISO R775)
E DIA PRESSURE
.35
2.50 DIA SUCTION
3.00
2.94
3.998 DIA
2.02 DIA
C.G.
4.000
.06 x 45°
.966 MAXI
.873 DIA
2.92
.875
4.57
.05 x 45°
S
SHAF
AFTT CODE 1 SHAF
SHAFTT CODE 4 S
SHAF
AFT CODE 3
MOUNTING TORQUE 138 ft.lbs .38 (KEYED NON SAE) SAE B-B INVOLUTE SPLINE DATA SAE B INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
MOUNTING TORQUE 45 ft.lbs 2.81 KEY .250 J498b - PITCH 16/32 J498b - PITCH 16/32
.31 .248 15 TEETH - 30° PRESSURE ANGLE 13 TEETH - 30° PRESSURE ANGLE
1.50
5 22409
1.000
T7BBS T7BB
00 01 M0 M1
SHAF
SHAFTT CO
CODE
DE 2 A DIA 3/8 16 UNC x .75 deep M10 x .75 deep
(Keyed SAE "B-B")
B DIA 1/2 13 UNC x .88 deep M12 x .88 deep
C 1.03 .87 1.03 .87
D 2.06 1.87 2.06 1.87
E DIA 1.00 .75 1.00 .75
F 5.75 5.51
G DIA .56 .55
OPERATING CHARACTERISTICS - TYPICAL [115 SUS]
Pressure Volumetric Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM
Series
Port Displacement Vi p = 0 PSI p = 2000 PSI p = 4650 PSI p = 100 PSI p = 2000 PSI p = 4650 PSI
B02 .35 in3/rev 2.76 2.31 1.73 0.97 4.53 9.34
B03 .60 in3/rev 4.66 4.21 3.63 1.08 6.78 14.49
B04 .78 in3/rev 6.09 5.64 5.06 1.17 8.47 18.36
B05 .97 in3/rev 7.56 7.11 6.53 1.25 10.22 22.35
B06 1.20 in3/rev 9.32 8.87 8.29 1.36 12.30 27.11
P1 B07 1.37 in3/rev 10.70 10.25 9.67 1.44 13.93 30.84
& B08 1.51 in3/rev 11.79 11.34 10.76 1.50 15.23 33.80
P2 B09 1.70 in3/rev 13.27 12.82 12.24 1.59 16.97 37.80
B10 1.92 in3/rev 14.98 14.53 13.95 1.69 19.00 42.43
B11 2.14 in3/rev 16.64 16.19 15.681) 1.79 20.97 44.051)
B12 2.47 in3/rev 19.26 18.81 18.291) 1.95 24.07 50.691)
B14 2.70 in3/rev 21.02 20.57 20.051) 2.05 26.16 55.151)
B15 3.01 in3/rev 23.49 23.04 22.592) 2.20 29.08 57.392)
1) B11 - B12 - B14 = 4350 PSI max. int. 2) B15 = 4060 PSI max. int.
Parker Hannifin
23 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T6CC SERIES
5 nnSérie1
== 1200
1200RPMRPM
60 SUS nnSérie2
== 1800
1800RPMRPM
P1-P2 υu == 150
150SUSSUS
4 70 Lw
Lw == Lp
Lp ++88db
db(A)
(A)
P1-P2
2 65
0 60
0 500 1000 1500 2000 2500 3000 3500 4000
0 500 1000 1500 2000 2500 3000 3500
Fa
Load F [Lbs]
1
100
0 50
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200 2600
Parker Hannifin
24 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 57.3 LBS - T6CC SERIES
2.29
K-4 HOLES E-4 HOLES .31
E-4 HOLES
1.03 1.25
B G 1.60
1.79 .31
.52
.31 .96
.96
KEY .1875
.1855 .06 x 45°
.06 x 45°
2.06
P2 S P1
A
1.03
F
.06 x 45°
.966 MAX
.874 DIA
S
SHAF
AFTT CODE 3 S
SHAF
AFT CODE 5
.875
SAE BB INVOLUTE SPLINE DATA SAE B INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
S
SHAF
AFT CODE 1 J498b - PITCH 16/32 J498b - PITCH 16/32
C DIA PRESSURE H DIA SUCTION 1.00 DIA PRESSURE 15 TEETH - 30° PRESSURE ANGLE 13 TEETH - 30° PRESSURE ANGLE
( Keyed no SAE )
10.46 2.81
6.87
3.47 4.00 1.50
.38 1.50 5.75
.31
2.87
.25 MAXI
KEY .250
.248
3.31
M8 x .63 DEEP
3.00
D
2.02 DIA
3.998 DIA
C.G.
4.000
.56 DIA
4.96
2.88
.06 x 45°
.968 DIA
1.111 MAX
.05 x 45°
1.000
T6CCW
MOUNTING TORQUE 45 ft.lbs
MOUNTING TORQUE 117 ft.lbs
S
SHAF
AFT CODE 2
( Keyed SAE B-B )
Alternate ports
2)
S = 3" S = 2"1/2
F 4.19 3.50
G 2.44 2.00
H DIA 3.00 2.50
1) 1)
Code 00 01 0M W0 10 11 1) 1M W1 1)
A 2.06 1.88 2.06 1.88 2.06 1.88 2.06 1.88 Shaft torque limits [in3/rev. x PSI]
B 1.03 .88 1.03 .88 1.03 .88 1.03 .88 Shaft Vi x p max.
C DIA 1.00 .75 1.00 .75 1.00 .75 1.00 .75 1 12666
D 2.94 3.00 2.94 3.00 2.94 3.00 2.94 3.00 2 18972
E 3/8" - 16 UNC x .75 deep M10 x .75 deep 3/8" - 16 UNC - .75 deep M10 x .75 deep 3 28937
K 5/8" - 11 UNC x 1.12 deep M16 x 1.12 deep 1/2" - 13 UNC x .941 deep M12 x .941 deep 5 18246
1) 2)
Max. cam 014 P1 + P2 = 7.69 in3/rev max.
Parker Hannifin
25 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T67CB SERIES
Pe ==13
Pe 13PSI absabs
PSI
Internal leakage Qs [GPM]
115 SUS
5 ==1200
1200RPM
nSérie1 RPM
60 SUS nSérie2
==1800
1800RPMRPM
P1 70 υ
u ==150
150SUS
SUS
4 Lw
Lw = Lp++88dbdb
= Lp (A)(A)
3 65
P1
P2
2
60
P2
1
0 55
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
5
n = 1200 RP M 350
4 n = 1800 RP M [115 SUS]
n = 2800 RP M P1
3 P1 300 F
Power loss Ps [HP]
2
P1 Fa
Load F [Lbs]
1 250
Shaft keyed N°1
0
0 500 1000 1500 2000 2500 3000 3500 4000 200
3,5
n = 1200 RP M
3 P2
n = 1800 RP M [115 SUS]
2,5 n = 2800 RP M 150
2 P2
1,5 100
P2
1
0,5
50
0
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200 2600
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 180 Lbs
its operating conditions.
Parker Hannifin
26 Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 57.3 Lbs - T67CB SERIES
3/8 16 UNC x .75 DEEP - 4 HOLES 3/8 16 UNC x .75 DEEP - 4 HOLES
(M10 x .75 DEEP - METRIC VERSION) (M10 x .79 DEEP - METRIC VERSION)
.50
1/2 13 UNC x .94 DEEP - 4 HOLES
(M12 x 1.18 DEEP - METRIC VERSION) 1.03 2.29
.88 2.00 .31
.52
1.79 1.60
1.25 .31 .31
.96 .96
KEY .1875
.1855
.06 x 45° .06 x 45°
2.06
P2 S P1
1.88
3.50
1.03
.874 DIA
.966 MAX
.06 x 45°
.875
SHAFT CODE 1 SHAFT CODE 3 SH
SHAFT
AFT CODE 5
2.50 DIA SUCTION 1.00 DIA PRESSURE (Keyed no SAE) SAE BB INVOLUTE SPLINE DATA SAE B INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
.75 DIA PRESSURE J498b - PITCH 16/32 J498b - PITCH 16/32
15 TEETH - 30° PRESSURE ANGLE 13 TEETH - 30° PRESSURE ANGLE
10.46 2.81 6.87
3.47 4.00 1.50 .38 5.75
.31 2.87
.25 MAXI 1.50
KEY .250
.248
3.31
M8 x .63 DEEP
3.00
3.00
3.950 DIA
2.02 DIA
C.G.
4.000
.56 DIA
1.111 MAX
.999 DIA
4.96
2.88
Parker Hannifin
27 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7DB - T7DBS SERIES
5 = 1200
Série1
60 SUS nnSérie2
= 1800RPM
= 1800 RPM
υu = 150SUS
= 150 SUS
4 70 Lw = Lp + 8 db (A)
Lw = Lp + 8 db (A)
3
P1
P2
2 65
P2
1
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
7
n = 1200 RP M
450
6 n = 1800 RP M [115 SUS] P1
n = 2500 RP M
5 400
4 P1 F
Power loss Ps [HP]
3
350 Fa
Load F [Lbs]
P1
2
Shaft keyed N°1
1
300
0
0 500 1000 1500 2000 2500 3000 3500
3 250
n = 1200 RP M
2,5 n = 1800 RP M [115 SUS] P2
2 n = 2500 RP M 200
P2
1,5
1 P2 150
0,5
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
28 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 85.1 Lbs - T7DB - T7DBS SERIES
A 2.44
.31
2.17 * 3.06
.31
1.97 .31
2.31
4.19
P2 S P1
B
1.378 MAX
1.389 MAX
1.248 DIA
.09 x 45°
1.259 DIA
1.250
1.260
.09 x 45°
S
SHAF
AFTT CODE
DE 2 S
SHAF
AFT CO
CODE
DE 5 S
SHAF
AFT CO
CODE
DE 3 SHA
SHAFT CO
CODE
DE 4
C DIA PRESSURE 3.00 DIA SUCTION 1.25 DIA PRESSURE ( Keyed no SAE ) ( Keyed ISO/R775 - G32M ) SAE C INVOLUTE SPLINE DATA SAE*C Spc INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE 14 TEETH - 30° PRESSURE ANGLE
11.26 3.29
4.31 4.50 1.50 W 8.36
3.25
2.94
DIA
d
C.G.
2.53 DIA
S DIA
5.10
1.389 MAX
1.248 DIA
2.92
.09 x 45°
1.250
e x 45° SHAF
SH AFT CO
CODE
DE 1
MOUNTING TORQUE 50 ft.lbs ( Keyed SAE C ) MOUNTING TORQUE 138 ft.lbs
Parker Hannifin
29 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T67DC SERIES
Pe ==1313
Pe PSIPSI
absabs
115 SUS n ==1200
1200 RPM
nSérie1 RPM
5 P1 n ==1800
1800 RPM
Internal leakage Qs [GPM]
3 70
P1
2 P2
65
1
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
7
n = 1200 RP M 450
6 n = 1800 RP M [115 SUS]
n = 2500 RP M
5 P1 400
4 F
P1
3
Power loss Ps [HP]
350 Fa
Load F [Lbs]
2
P1 Shaft keyed N°1
1
300
0
0 500 1000 1500 2000 2500 3000 3500
4 250
n = 1200 RP M
n = 1800 RP M [115 SUS]
3 n = 2500 RP M
P2 200
P2
2
P2
150
1
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
30 Denison Vane Pump Division
Vierzon - France
DIMENSIONS - Weight : 85.1 Lbs - T67DC SERIES
3/8 16UNC x .75 DEEP-4 HOLES 7/16 14UNC x .88 DEEP-4 HOLES
(M10 x .75 DEEP - METRIC VERSION ) ( M12 x .88 DEEP - METRIC VERSION )
5/8 11UNC x 1.12 DEEP-4 HOLES .62 2.88
( M16 x 1.12 DEEP - METRIC VERSION ) 1.19 .31 3.28
.52 1.22
.31
2.17
.31
* 3.06 .31
.09 x 45°
1.50 KEY .3126
.3106
1.16
1.03
P2 S P1
B
2.31
4.19
2.09
M8 x .63 DEEP
1.389 MAX
1.248 DIA
1.513 MAX
1.373 DIA
-
.09 x 45°
1.250
1.374
T67DCW
SHAF
SHAFTT CODE 2 SHAF
AFTT CODE 3 SHAFT CO
CODE
DE 4 SHAFT CODE 5
3.00 DIA SUCTION
( Keyed non SAE ) SAE C INVOLUTE SPLINE DATA SAE*C Spc INVOLUTE SPLINE DATA ( Keyed non SAE )
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
C DIA PRESSURE 1.25 DIA PRESSURE J498b - PITCH 12/24 J498b - 12/24 dp
14 TEETH - 30° PRESSURE ANGLE 14 TEETH - 30° PRESSURE ANGLE
3.25
2.94
4.998 DIA
C.G.
2.53 DIA
5.000
5.05
.69 DIA
2.92
.09 x 45°
1.389 MAX
1.248 DIA
.05 x 45°
1.250
Parker Hannifin
31 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7DD - T7DDS SERIES
5
60 SUS nnSérie2
= 1800
1800RPMRPM
P1-P2 75 υu = 150SUS
= 150 SUS
4 Lw
Lw ==Lp
Lp +
+ 88 db
db(A)
(A)
3 P1-P2 70
65
1
0 60
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
7 450
n = 1200 RPM
n = 1800 RPM [115 SUS]
6 P1-P2 400
n = 2500 RPM
F
5 350 Fa
Power loss Ps [HP]
Load F [Lbs]
P1-P2
Shaft keyed N°1
4 300
3 250
P1-P2
2 200
1 150
0 100
0 500 1000 1500 2000 2500 3000 3500 600 900 1200 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 180 Lbs
its operating conditions.
Parker Hannifin
32 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 123.4 Lbs - T7DD - T7DDS SERIES
.09 x 45°
.09 x 45°
2.31
P2 S P1
6.39
2.31
7.17
5.13
1.668 MAXI
SAE C INVOLUTE SPLINE DATA
1.498 DIA
CLASS 1-FLAT ROOT SIDE FIT
1.500
J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE
13.69 3.31
5.28 5.84 1.51 w
.31
.25 MAXI
KEY .3126
.3106
1.94
d2
D
IA
4.52
4.00
4.00
d1 DIA
C.G.
2.53 DIA
S DIA
K2
M10 x .79 DEEP
6.73
.09 x 45°
3.59
1.389 MAXI
1.248 DIA
e x 45°
1.250
2.68 1.81 SH
SHAFT
AFT CO
CODE
DE 1 K1
.39 .31
Keyed SAE C 8.39
1.97 .97
.06 x 45°
M10 x .79 DEEP
1.614 MAXI
1.260 DIA
1.261
SH
SHAFT
AFT CO
CODE
DE 5 SH
SHAF
AFT
T CO
CODE
DE 4
Keyed ISO 3019/2 -G32M SAE BB INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 16/32
15 TEETH - 30° PRESSURE ANGLE
Shaft torque limits [in3/rev. x PSI]
Shaft Vi x p max.
Alternate mounting flange 1 38299
S DIA 2 63552
Series e x 45° W K1 d1 DIA K2 d2 DIA
Max. Min. 3 54207
T7DD 4.921 4.919 .079 .374 7.087 .709 4.454 .551 4 31780
T7DDS 5.000 4.998 .059 .500 7.126 .689 4.508 .563 5 40035
OPERATING CHARACTERISTICS - TYPICAL [115 SUS]
Pressure Volumetric Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM
Series
port Displacement Vi p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI
B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74
B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60
B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46
B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96
P1 B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35
&
B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20
B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19
P2 B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27
B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37
B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27
045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)
050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)
1) 045 = 3500 PSI max. int. 2) 050 = 3000 PSI max. int.
Parker Hannifin
33 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7EB - T7EBS SERIES
7,5 nnSérie1
==1200
1200RPM
RPM
60 SUS
nnSérie2
==1800
1800RPM
RPM
P1 75 υu ==150150SUS
SUS
6 Lw
Lw == Lp
Lp ++88dbdb(A)(A)
4,5 70
P1
3
P2 65
1,5
P2
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
7 450
6
P1
5
P1 400
4
F
3
Power loss Ps [HP]
P1 350
2 n = 1200 RP M Fa
Load F [Lbs]
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
34 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 121.2 Lbs - T7EB - T7EBS SERIES
3.54
.39
B x 1.16 DEEP - 4 HOLES A x .92 DEEP - 4 HOLES W
2.75
1.41 T7EB
C x .75 DEEP - 4 HOLES
.87
1.38
1.97 .31
2.20
.31
* 2.45 .31
2.44
KEY .313
M10 x .79 DEEP .311
.09 x 45° .09 x 45°
2.38
S DIA
P2 S P1
1.87
2.75
4.75
1.626 MAX
1.389 MAX
.09 x 45°
1.496 DIA
1.248 DIA
1.497
.09 x 45°
1.250
e x 45°
S
SHAF
AFT CODE 5 SHAF
SHAFTT CODE 3 SHAFT CO DE 4 SHA
CODE SHAFT CODE 2
.75 DIA PRESSURE ( Keyed ISO/R775 - G38M) SAE C INVOLUTE SPLINE DATA SAE *CC INVOLUTE SPLINE DATA (Keyed no SAE )
1.46 DIA PRESSURE CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
3.50 DIA SUCTION J498b - PITCH 12/24 J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE 17 TEETH - 30° PRESSURE ANGLE
13.06 3.58 8.39
5.38 4.67 2.06 W T7EBS K
.31
K/2
.25 MAX 2.00
KEY .375
.373
3.87
DIA
2.94
d
1.668 MAX
1.498 DIA
C.G.
3.00 DIA
S DIA
1.500
.09 x 45°
3.00
5.87
3.50
e x 45°
Parker Hannifin
35 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T67EC SERIES
60 SUS nnSérie2
==1800
1800RPMRPM
75 υu ==150
170SUS
SUS
6 Lw
Lw = Lp++88dbdb
= Lp (A)(A)
P2
4,5 70
3 P2
P1
65
1,5
0 60
0 500 1000 1500 2000 2500 3000 3500 4000
0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
8
450
7
P1
6
5 400
P1 F
4
Power loss Ps [HP]
3 P1 350 Fa
Load F [Lbs]
2 n = 1200 RP M
1 n = 1800 RP M [115 SUS] Shaft keyed N°1
n = 2200 RP M 300
0
0 500 1000 1500 2000 2500 3000 3500
4 250
n = 1200 RP M
n = 1800 RP M [115 SUS]
3 n = 2200 RP M P2
P2 200
2 P2
150
1
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 1000 1400 1800 2200
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
36 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 121.2 Lbs - T67EC SERIES
5/8 11 UNC x 1.16 DEEP - 4 HOLES 1/2 13 UNC x .92 DEEP - 4 HOLES
(M16 x 1.16 DEEP - METRIC VERSION ) (M12 x .92 DEEP -METRIC VERSION )
.69 2.44
3/8 16 UNC x .75 DEEP - 4 HOLES .31
(M10 x .75 DEEP - METRIC VERSION) 1.41
2.75
1.03
1.38 .70 2.20
.52 .31 2.45
1.50 .31
1.50
1.24
KEY .3125
.3105
.09 x 45° .09 x 45°
1.03
P2 S P1
2.06
1.389 MAX
1.248 DIA
.09 x 45°
1.250
SH
SHAFT
TCCODE
DE 2 SHAF
SHAFTT CODE 3 SHAF
SHAFTT CODE 4
1.00 DIA PRESSURE 3.50 DIA SUCTION 1.50 DIA PRESSURE ( Keyed no SAE ) SAE C INVOLUTE SPLINE DATA SAE CC INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
13.06 3.58 14 TEETH - 30° PRESSURE ANGLE 17 TEETH - 30° PRESSURE ANGLE
.31 7.13
3.56
KEY .375
.25 MAXI 2.00 .373
3.87
.69 DIA
2.94
4.998 DIA
3.00 DIA
C.G.
5.000
1.668 MAX
1.498 DIA
3.00
5.87
3.50
1.500
.09 x 45°
.05 x 45°
Parker Hannifin
37 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7ED - T7EDS SERIES
7,5
60 SUS nnSérie2
==1800
1800RPMRPM
υu ==150150SUS
SUS
6 P2 75 Lw
Lw = Lp++88dbdb
= Lp (A)(A)
4,5
3 70
P1
P2
1,5
0 65
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
8 875
7
P1
6 800
5
P1 F
4 725
3 P1 Fa
Power loss Ps [HP]
Load F [Lbs]
2 n = 1200 RP M 650
n = 1800 RP M [115 SUS] Shaft keyed N°1
1 n = 2200 RP M
0 575
0 500 1000 1500 2000 2500 3000 3500
7 500
n = 1200 RP M
6 n = 1800 RP M [115 SUS] P2 425
5 n = 2200 RP M
P2
4 350
3 P2
2 275
1
200
0
600 1000 1400 1800 2200
0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
38 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 145.5 Lbs - T7ED - T7EDS SERIES
1.50
M10 x .79 DEEP .09 x 45° .09 x 45°
2.56
1.37
1.16
1.626 MAX
1.496 DIA
2.75
S DIA
P2 S P1
2.31
1.497
5.13
.09 x 45°
e x 45°
SHAF
SHAFTT CO
CODE
DE 5 SHAFT
SH AFT C
CODE
DE 4 SHA
SHAFT
T CODE 3
1.25 DIA PRESSURE 4.00 DIA SUCTION 1.46 DIA PRESSURE ( Keyed ISO/R775 - G38M) SAE CC INVOLUTE SPLINE DATA SAE C INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
17 TEETH - 30° PRESSURE ANGLE 14 TEETH - 30° PRESSURE ANGLE
8.39
5.83
14.21
5.26 2.06 W
3.58
T7EDS K
3.88
d DIA
1.668 MAX
3.00 DIA
1.498 DIA
C.G.
S DIA
1.500
.09 x 45°
3.19
3.50
6.34
e x 45°
SHAF
SHAFTT CODE 1
MOUNTING TORQUE 138 ft.lbs
2.44
MOUNTING TORQUE 138 ft.lbs
(Keyed SAE CC )
.09 x 45°
1.250
Parker Hannifin
39 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7EE - T7EES SERIES
nn == 1200
1200RPMRPM
60 SUS Série1
7 nnSérie2
== 1800
1800RPMRPM
υu == 150
150SUS
SUS
P1-P2 Lw
Lw==Lp + 88db
db(A)
(A)
6
75 Lp +
5
4 P1-P2
3 70
0 65
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Double pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
P1-P2
5 Fa
Load F [Lbs]
3 500
425
2
350
n = 1200 RPM
1 n = 1800 RPM [115 SUS] 275
n = 2200 RPM
0 200
0 500 1000 1500 2000 2500 3000 3500 600 1000 1400 1800 2200
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
40 Denison Vane Pump Division
Vierzon - France
DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 209.4 - T7EE AND T7EES SERIES
16.84 2.45
3.62
.39 M12 x 1.10 DEEP .31
KEY .551 x .354 1.41
1/2 - 13UNC x .92 DEEP - 4 HOLES 1/2 - 13UNC x 1.18 DEEP - 4 HOLES
(M12 x .92 - METRIC VERSION) (M12 x 1.18 - METRIC VERSION)
5/8 - 11UNC x 1.18 DEEP - 4 HOLES
3.06
(M16 x 1.18 - METRIC VERSION)
2.48 1.41
.09 x 45°
M12 x .94 DEEP
1.909 MAX
1.7707 DIA
9.840 DIA
5.75 DIA
P2 S P1
8.77
6.82
2.75
1.7717
9.843
5.13
8.23
2.75
.12 x 45°
SH
SHAFT
AFT C
CODE 3
SAE CC SPLINED SHAFT
CLASS 1- J498b
T7
T7EE
12/24 D.P. - 17 TEETH
30° PRESSURE ANGLE
FLAT ROOT SIDE FIT
.06 x 45°
.87 .35 (KEYED G45N-ISO 3019-2) .25
16.02
10.75
8.84 .81 6.22 6.59 1.69 3.58
.31
2.00
.31
KEY .375
.373
2.50
5.50
4.53
1.668 MAX
3.87
C.G.
4.002 DIA
6.498 DIA
10.75
8.84
4.004
6.500
4.11
1.499 DIA
3.41
6.69
1.500
4.65
M10 x .79 DEEP
.06 x 45°
.61
2.95 3.94
.31 .31
2.50
KEY .437
1.92
.435
1/2 - 13 UNC
.12 x 45° x .94 DEEP
1.941 MAX
1.748 DIA
.09 x 45°
1.750
SHAFT CO
CODE 4 SHAF
AFT CODE 5
SAE D & E SPLINED SHAFT
CLASS 1- J498b (KEYED SAE D&E)
8/16 D.P. - 13 TEETH
30° PRESSURE ANGLE
FLAT ROOT SIDE FIT
Parker Hannifin
41 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T67DBB SERIES
Parker Hannifin
42 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T67DBB SERIES
3 P1
P2-P3
2 65
1
P2-P3
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
0 300
0 500 1000 1500 2000 2500 3000 3500
3,5 250
n = 1200 RPM
3 n = 1800 RPM [115 SUS]
2,5 n = 2500 RPM P2-P3 200
2
P2-P3
1,5
P2-P3 150
1
0,5
100
0
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
43 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T67DCB SERIES
Parker Hannifin
44 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T67DCB SERIES
6 80
P1 Pe = 13 PSI abs
Pe = 13 PSI abs
115 SUS
5 nnSérie1
==1200
1200RPMRPM
60 SUS
nnSérie2
==1800
1800RPMRPM
P2
Internal leakage Qs [GPM]
3 70
P2
P1
2 P3
65
1
P3
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
4 P1
3
P1
2 450
1
0
400
Power loss Ps [HP]
5 Fa
n = 1200 RPM 350
4 n = 1800 RPM [115 SUS] P2 Shaft keyed N°1
n = 2500 RPM
3 P2
300
2
P2
1
0 250
0 500 1000 1500 2000 2500 3000 3500 4000
4 200
n = 1200 RPM
3 n = 1800 RPM [115 SUS] P3
n = 2500 RPM
2 P3
150
P3
1
0
100
0 500 1000 1500 2000 2500 3000 3500 4000
6001200900 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 180 Lbs
its operating conditions.
Parker Hannifin
45 Denison Vane Pump Division
Vierzon - France
B x 1.18 DEEP- 4 HOLES
A x .88 DEEP- 4 HOLES
C x .75 DEEP- 4 HOLES .62 3.53
C x .75 DEEP- 4 HOLES 1.03 3.06 1.19 2.17
.87 2.50 2.40
1.24
1.50
46
M10 x .79 DEEP .09 x 45 ° .09 x 45 °
1.87
P3 P2 S P1
5.13
2.31
1.664 MAX
1.500
1.499 DIA
2.06
.09 x 45°
5.00
4.00
3.25
2.94
.69 DIA
C.G.
2.53 DIA
5.000
4.998 DIA
7.09
2.91
DIMENSIONS - Weight : 134.5 - T67DBB - T67DCB SERIES
.09 x 45°
3.35
1.360 MAX
1.250
1.248 DIA
SHAF
AFTTC
CODE
DE 1
.05 x 45°
( Keyed non SAE ) 3.56
MOUNTING TORQUE 138 ft.lbs 7.13
MOUNTING TORQUE 50 ft.lbs
Shaft torque limits [in3/rev. x PSI] MOUNTING TORQUE 138 ft.lbs
Shaft Vi x p max. P1 + P2 + P3 Alternate connect. variables
Vierzon - France
Parker Hannifin
1 38299 01 M1
2 58902 A 7/16” - 14 UNC M12
3 54207 B 5/8” - 11 UNC M16
4 58902 C 3/8” - 16 UNC M10
47
.09 x 45°
A
2.31
P3 P2 S P1
2.06
5.13
.09 x 45°
1.664 MAX
1.500
1.499 DIA
C DIA PRESSURE
SH
SHAFT
AFT CODE 2 SHA
SHAFT CODE 3 S
SHAF
AFTT CODE 4
1.00 DIA PRESSURE 4.00 DIA SUCTION 1.25 DIA PRESSURE ( keyed SAE CC ) SAE C INVOLUTE SPLINE DATA SAE CC INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE 17 TEETH - 30° PRESSURE ANGLE
15.91 3.29
8.36
3.32 4.70 5.43 1.50 .50
.31
.25 MAXI
1.94
KEY .250
.248
5.00
4.00
3.25
2.94
.69 DIA
C.G.
2.53 DIA
5.000
4.998 DIA
7.09
DIMENSIONS - Weight : 134.5 Lbs - T67DCC SERIES
2.91
.09 x 45°
3.35
.05 x 45°
1.362 MAX
1.250
1.248 DIA
Vierzon - France
Parker Hannifin
1 38299 00 & M0 01 & M1
2 58902 A 2.063 1.874
3 54207 B 1.031 .874
4 58902 C 1.000 .748
Parker Hannifin
48 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T67DCC SERIES
6 80
Pe = 13 PSI abs
115 SUS Pe = 13 PSI abs
5 P1 nSérie1
n ==1200
1200RPM
RPM
60 SUS
nSérie2
n = 1800
= 1800 RPMRPM
75 υ = 150 SUS
P2-P3 uLw==150
Lp SUS
+ 8 db (A)
4 Lw = Lp + 8 db (A)
Internal leakage Qs [GPM]
0 60
0 500 1000 1500 2000 2500 3000 3500 4000
0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
3
P1 400 Shaft keyed n°1
Power loss Ps [HP]
2
F
Load F [Lbs]
1 350 Fa
0 Shaft keyed N°1
0 500 1000 1500 2000 2500 3000 3500 300
4
n = 1200 RPM
3,5 250
n = 1800 RPM [115 SUS] P2-P3
3 n = 2500 RPM
2,5
P2-P3 200
2
P2-P3
1,5
1 150
0,5
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
49 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7DDB - T7DDBS SERIES
Parker Hannifin
50 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T7DDB - T7DDBS SERIES
6 80
Pe = 13 PSI abs
Pe = 13 PSI abs
115 SUS
5 nSérie1
n ==1200
1200RPM
RPM
P1-P2
Lw = Lp + 8 db (A)
3 70
P1-P2
2 P3
65
1
P3
0 60
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Pressure p [PSI] Pressure p [PSI]
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
4 P1-P2
400
3
P1-P2
2
350 F
Power loss Ps [HP]
1
Fa
Load F [Lbs]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
51 Denison Vane Pump Division
Vierzon - France
7/16 14UNC x .88 DEEP
7/16 14UNC x .94 DEEP M12 x .88 DEEP-METRIC VERSION
M12 x .94 DEEP-METRIC VERSION
2.20
3/8 16UNC x .75 DEEP 5/8 11UNC x 1.18 DEEP
M16 x 1.18 DEEP-METRIC VERSION .31
M10 x .75 DEEP-METRIC VERSION
B 1.19 3.06 1.19 .25 MAXI
2.68 3.58
.39 .31
1.97
2.00 KEY .375
.373
52
1.50 KEY .394 x .315
.09 x 45°
.09 x 45°
5.13
2.31
7.17
P3 P2 S P1
2.31
1.500
1.498 DIA
1.668 MAX
1.614 MAX
1.261
1.260 DIA
M10 x .79 DEEP
17.91 3.31
4.72 4.92 5.85 1.50 W
.31
.09 x 45°
4.52
4.00
4.00
2.94
C.G.
K2
S DIA
2.53 DIA
8.13
d1 DIA
.09 x 45°
3.59
M10 x .79 DEEP
e x 45°
SHA
SHAFT C
CODE
DE 4
1.250
1.248 DIA
1.389 MAX
.75
DIMENSIONS - Weight : 145.5 Lbs - T7DDB - T7DDBS SERIES
MOUNTNG TORQUE 59 ft.lbs MOUNTING TORQUE 140 ft.lbs MOUNTING TORQUE 140 ft.lbs K2 SAE CC INVOLUTE SPLINE DATA
SHA
SHAFT
T COD
CODE 1 K1 CLASS 1-FLAT ROOT SIDE FIT
8.39 J498b - PITCH 12/24
Keyed SAE C 17 TEETH - 30° PRESSURE ANGLE
Vierzon - France
Parker Hannifin
1 38299
2 64044 Series S Dia e x 45° W K1 d1 Dia K2 d2 Dia 00 & M0 01 & M1
3 54207 Max. Min. A 2.063 1.874
4 58902 T7DDB 4.921 4.919 .079 .374 7.087 .709 4.454 .551 B 1.031 .874
5 47033 T7DDBS 5.000 4.998 .059 .500 7.126 .689 4.508 .563 C 1.000 .748
2.35
2.00 KEY .375
KEY .3126
53
.3106 .373
.09 x 45°
.09 x 45° .09 x 45°
A
7.17
5.13
P3 P2 S P1
2.31
2.31
1.668 MAX
1.500
1.498 DIA
1.374
1.372 DIA
1.513 MAX
S
SHAF
AFT COD
CODE 3 SH
SHAFT
AFT CO
CODE
DE 5 SHAF
SHAFTT COD
CODE 2
SAE C INVOLUTE SPLINE DATA (KEYED NO SAE) ( KEYED SAE CC )
C DIA PRESSURE 4.00 DIA SUCTION CLASS 1-FLAT ROOT SIDE FIT
1.25 DIA PRESSURE 1.25 DIA PRESSURE J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE
17.91 3.31
.09 x 45°
4.53
4.00
4.00
2.94
C.G.
4.51
2.53 DIA
5.000
4.998 DIA
8.13
.69 DIA
.09 x 45°
3.59
DIMENSIONS - Weight : 145.5 Lbs - T67DDCS SERIES
1.389 MAX
.05 x 45°
1.250
1.248 DIA
Vierzon - France
Parker Hannifin
1 38299
2 64044 Alternate port
3 54207 Port Code A B C
4 58902 00 - M0 2.063 1.031 1.000
P3
5 49247 01 - M1 1.874 .874 .748
Parker Hannifin
54 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T67DDCS SERIES
6 80
P1-P2 Pe = 13 PSI abs
115 SUS Pe = 13 PSI abs
5 nnSérie1
==1200
1200RPM
RPM
3 70
P1-P2
2 P3
65
1
0 60
0 500 1000 1500 2000 2500 3000 3500 4000
0 500 1000 1500 2000 2500 3000 3500
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
7
n = 1200 RPM
6 n = 1800 RPM [115 SUS] 450
n = 2500 RPM
5 P1-P2
4 400
F
P1-P2
3
Fa
2
350
P1-P2 Shaft keyed N°1
Power loss Ps [HP]
1
Load F [Lbs]
0
300
0 500 1000 1500 2000 2500 3000 3500
4
n = 1200 RP M
250
n = 1800 RP M [115 SUS]
3 n = 2500 RP M
P3 200
P3
2
P3
150
1
0 100
0 500 1000 1500 2000 2500 3000 3500 4000 600 900 1200 1500 1800 2100 2400
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 270 Lbs
its operating conditions.
Parker Hannifin
55 Denison Vane Pump Division
Vierzon - France
ORDERING CODE - T7EDB - T7EDBS SERIES
Parker Hannifin
56 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T7EDB - T7EDBS SERIES
υnSérie2
==1800
150RPM
6 75 Lw = Lp + 8 db (A)
P2
4,5
P2
3 70
P1
P3
1,5
P3
0 65
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
7 Fa
Load F [Lbs]
n = 1200 RPM
6
n = 1800 RPM [115 SUS] P2 300 Shaft keyed N°1
5 n = 2200 RPM
4 P2
3 P2
2 250
1
0
0 500 1000 1500 2000 2500 3000 3500 200
4
n = 1200 RPM
3 n = 1800 RPM [115 SUS] P3
2 n = 2200 RPM 150
P3
1
P3
0 100
0 500 1000 1500 2000 2500 3000 3500 4000
600 1000 1400 1800 2200
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
57 Denison Vane Pump Division
Vierzon - France
3.62
2.95
.39
3/8 - 16 UNC x .75 DEEP- 4 HOLES 5/8 - 11 UNC x 1.18 DEEP- 4 HOLES
(M10 x .75 DEEP- METRIC VERSION) (M16 x 1.18 DEEP- METRIC VERSION) w c x 45° T7EDB .31
1/2 - 13 UNC x 1.18 DEEP- 4 HOLES
7/16 - 14 UNC x .94 DEEP- 4 HOLES (M12 x 1.18 DEEP- METRIC VERSION) 1.41 1.92
(M12 x .94 DEEP-METRIC VERSION)
3.06
1.19
B 2.48
58
DIA
A
P3 P2 S P1
2.75
2.31
5.13
8.23
.12 x 45° .12 x 45°
C DIA PRESSURE
1.772
1.771 DIA
1.909 MAX
S
SHAFT
AFT CO
CODE
DE 3
KEY .437
.435
45°
5.50
2.50
4.53
2.94
4.00
C.G.
10.75
S DIA
1.941 MAX
6.74
.09 x 45°
1.750
1.748 DIA
4.17
DIMENSIONS - Weight : 224.9 Lbs - T7EDB - T7EDBS SERIES
Shaft torque limits [in3/rev. x PSI] Alternate mounting flange Alternate connect. variables
Vierzon - France
Parker Hannifin
Shaft Vi x p max. P1 + P2 + P3 Series S Dia e x 45° W K Z Dia d Dia 00 & M0 01 & M1
1 101506 Max. Min. A 2.063 1.874
2 104818 T7EDB 9.842 9.840 .079 .354 - 12.401 .866 B 1.031 .874
3 112312 T7EDBS 6.500 6.498 .079 .354 8.838 - .811 C 1.000 .748
59
A
P3 P2 S P1
S DIA
2.75
2.31
5.13
8.23
.12 x 45° .12 x 45°
C DIA PRESSURE
SHAF
AFTT CO
CODE 3
1.772
1.771 DIA
1.909 MAX
MOUNTING TORQUE 165 ft.lbs SAE D & E INVOLUTE SPLINE DATA
45°
5.50
2.50
4.53
2.94
4.00
C.G.
10.75
S DIA
1.941 MAX
6.74
.09 x 45°
4.17
1.750
1.748 DIA
Shaft torque limits [in3/rev. x PSI] Alternate mounting flange Alternate connect. variables
Vierzon - France
Parker Hannifin
Shaft Vi x p max. P1 + P2 + P3 Series S Dia e x 45° W K Z Dia d Dia 00 & M0 01 & M1
1 101506 Max. Min. A 2.063 1.874
2 104818 T7EDC 9.842 9.840 .079 .354 - 12.401 .866 B 1.031 .874
3 112312 T7EDCS 6.500 6.498 .079 .354 8.838 - .811 C 1.000 .748
Parker Hannifin
60 Denison Vane Pump Division
Vierzon - France
TECHNICAL DATA - T67EDC - T67EDCS SERIES
Lw Lp + 8 db (A)
6 75 Lw = Lp + 8 db (A)
P3
P2
4,5
3 70
P1 P2
P3
1,5
0 65
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500
Do not operate pump more than 5 seconds at any speed or vis- Triple pump noise level is given with each section discharging
cosity if internal leakage is higher than 50% of theoretical flow. at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
Fa
8
7 n = 1200 RPM
300 Shaft keyed N°1
6 n = 1800 RPM [115 SUS] P2
Load F [Lbs]
5 n = 2200 RPM
4
3 P2
2
250
1 P2
0
0 500 1000 1500 2000 2500 3000 3500 200
6
5 n = 1200 RPM
n = 1800 RPM [115 SUS] P3
4
3
n = 2200 RPM
P3
150
2 P3
1
0
100
0 500 1000 1500 2000 2500 3000 3500 4000
600 1000 1400 1800 2200
Pressure p [PSI] Speed n [RPM]
Total hydromechanical power loss is the sum of each section at Maximum permissible axial load Fa = 449 Lbs
its operating conditions.
Parker Hannifin
61 Denison Vane Pump Division
Vierzon - France
PORTING DIAGRAMS - GENERAL CATALOG
T7BB/T7BBS 00 01 02 03 04 05 06 07
P1-P2 P1-P2 S-P1-P2 P1-P2 P1 P1 P1 P1-S
T6CC S S
S S P2
P2 P2
S S-P2
T67CB
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1 P1 P1 P1 P1
T7DB/T7DBS P2
S P2
P2 S P2
P2 S S
T67DC P2 P2 S P2 S
T7EB/T7EBS 16 17 18 19 20 21 22 23
P1 P1 P1 P1 P1 P1 P1 P1
P2 P2 P2 P2
T67EC S S S S
P2 P2 P2 P2
S S S S
24 25 26 27 28 29 30 31
P1-S P1-S P1-S P1-S P1 P1 P1 P1
P2 P2 P2 P2
S S S S
P2 P2 P2 P2
T7DD/T7DDS 00 01 02 03 04 05 06 07
P1-P2 P1-P2 S-P1-P2 P1-P2 P1 P1 P1 P1-S
T7ED/T7EDS S S
S S P2
P2 P2
S S-P2
T7EE/T7EES
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1 P1 P1 P1 P1
S P2 P2
P2 S P2
P2 S S
P2 P2 S P2 S
T67DBB 00 01 02 03 04 05 06 07
P1-P2-P3 P1-P2-P3 S-P1-P2-P3 P1-P2-P3 P1 P1 P1 P1-S
S S
T67DCB S S P2 P2
P2
P3
P3 P3
S S-P2-P3
T67DCC
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1-P2 P1-P2 P1-P3 P1 P1-P3
T7DDB/T7DDBS S
P2 S P2 S
S
P3 P3 S P2
P2
T67DDCS P2-P3 P2-P3 S-P3 P2-P3
16 17 18 19 20 21 22 23
T7EDB/T7EDBS S-P1-P2 S-P1-P2 S-P1-P2 S-P1-P3 S-P1-P3 S-P1-P3 P1-P2 P1
S
P3
P3 P3 P2 P2 S
T67EDC/T67EDCS P2
P3
P3 P2
24 25 26 27 28 29 30 31
P1 P1 P1 P1-P3 P1-S P1-S P1-S P1-S
P2
P3 P2 P2 P3
S
P2 P3 P2 P3
P3
S S S-P2 P3 P3 P2 P2
32 33 34 35 36 37 38 39
P1-S P1-S P1-P2 P1-P2 P1-P2 P1-P2 P1-P2 P1-P2
P2 S S P3 S S
P3 P3 P3 P3
P2 P3
P3 P3 S S
40 41 42 43 44 45 46 47
P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1 P1
S
P2 P2 P2 S
S S S S
P2 P2 P3 P2
P2 P2 S S P3
48 49 50 51 52 53 54 55
P1 P1 P1 P1 P1 P1 P1 P1
S S
P3 P3 P3 P2 P3
P2 P3 P2 S S
P2 P2
P2 S-P2 S-P2 S-P3 S-P3 P3
56 57 58 59 60 61 62 63
P1 P1 P1 P1 P1 P1 P1 P1
S P2 S S P2 P2 P3
P3 P3
P3 S P2 P3 S P2 S
P3
P2 P2 P3 S P3 S P2
Parker Hannifin
62 Denison Vane Pump Division
Vierzon - France
PORTING DIAGRAMS - GENERAL CATALOG
T67DBB 64 65 66 67 68 69 70 71
P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
P2 P2 P2 P2
T67DCB
P3 P3 P3 P3
S S S S S-P2 S-P2 S-P2 S-P2
T67DCC 72 73 74 75 76 77 78 79
P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
T7DDB/T7DDBS P2 P2 P2 P2
P3 P3 P3 P3
S S S S S S S S
T67DDCS
80 81 82 83 84 85 86 87
P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
T7EDB/T7EDBS S S S S
S S S S
P2 P2 P2 P2
P3 P3 P3 P3
T67EDC/T67EDCS P2 P2 P2 P2
88 89 90 91 92 93 94 95
P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
P2 P2 P2 P2
S S S S
S S S S
P3 P3 P3 P3
96 97 98 99 1A 1B 1C 1D
P3 P1-S P1-S P3 P1-S P1-S P3 P1-S P1-S P3 P1-S P1-S
P2 P2 P2 P2
P3 P3 P3 P3
P2 P2 P2 P2
1E 1F 1G 1H 1J 1K 1L 1M
P3 P1-S P1-S P3 P1-S P1-S P3 P1-S-P2 P1-S-P2 P3 P1-S-P2 P1-S-P2
P2 P2 P2 P2
P3 P3 P3 P3
1N 1P 1R 1S 1T 1U 1V 1W
P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
S S S
P2 S S S S S
P2 P2 P2
P3 P3 P3 P3
P2 P2 P2 P2
1X 1Y 1Z 2A 2B 2C 2D 2E
P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
S
S S S S S S S
P2
P2 P2 P2
P3 P3 P3 P3
P1
S P2 P3 P2 P3
02 16 17 18 20 30 08 31
19 07 28 32 21 33 29 09
01 22 34 38 40 48 10 58
13 04 46 47 45 49 59 23
00 36 11 37 27 51 05 50
42 24 53 60 43 62 52 25
03 39 35 12 41 63 14 57
44 26 61 56 15 54 55 06
Parker Hannifin
63 Denison Vane Pump Division
Vierzon - France