You are on page 1of 24

Reduces Fuel

Consumption
by 7% - 30%
_______________________

On Properly Installed Commercial Burners


Reduces Harmful
Carbon Emissions
_______________________

Proven to Reduce CO2, NOx,


CO, SO2 and Particulate Matter
Rentar Fuel Catalyst
Is Independently
Verified To:
_______________________
• Reduce Fuel Consumption And Extend Range
• Reduce Greenhouse Gases (NOx, CO and CO2)
• Reduce Particulate Matter (PM)
• Reduce Black Smoke (Opacity)
• Reduce Organic And Elemental Carbon

* VERIFIED BY NUMEROUS INDEPENDENT 3RD PARTY EPA, CARB AND GOVERNMENT RECOGNIZED LABORATORIES
Rentar Is Independently Verified Effective By:
___________________________________________________________

• Southwest Research Institute


EPA Recognized Laboratory
• Aberdeen Proving Grounds
• Naval Facilities Engineering Services
• U.S. Marine Corps
• Olson Ecological Laboratories
EPA And (CARB) Recognized LAB

• Virginia Tech University

• Italian Ministry Of Defense

• England's Millbrook Proving Ground

• Venezuela's Ministry Of The


Environment
Benefits

BENEFITS
______________________________________________

Reduces Fuel Consumption, Greenhouse Gas and Air Pollution.


Pays For Itself In 3 to 12 Months
Mechanism to Generate Carbon Credits
Easy To Install
No Maintenance
10 Year Limited Warranty
Enhances Green Image of User
Rentar Environmental Solutions, Inc. has achieved
____________________________________________

• Fully Developed Technology


• UL Listed
• 27 U.S. and World-wide Patents
• Government and Fortune 500 Clients
• A Mechanism to Create Carbon Credits
• GSA Listing in Process (General Services Administration)
_______________________
Rentar Fuel Catalyst Boiler Study
Conducted for the State of Delaware

9.0% reduction in CO2 (Carbon Dioxide) Greenhouse Gases


13.0% reductions NOx (Nitrous Oxide)
4.0% reduction in CO (Carbon Monoxide)
13.0% reductions in Hydro-carbons
21.0% reduction in SO2 (Sulfur Dioxide)
CBS
Local News
Video
Draft . . . Power Point Furnace Catalyst 24 Slides

Click on Picture to Start Video


How The Rentar Fuel Catalyst Works
__________________________________________

• Fuel is passed thru the catalyst’s


patented combination of metallic
and rare earth elements.

• A reaction occurs separating


the clustered molecules.

• The more fuel molecules that are


exposed to oxygen, the more efficiently the
fuel is burned, leaving less to be blown out the
exhaust as wasted horsepower and pollution.
The Science Of The Rentar Technology
_________________________________________________________

The Rentar Fuel Catalyst consists of an encapsulated epoxy matrix of proprietary catalytic / heterogeneous materials consisting of metal
and rare earth elements (27 patents) which preconditions the fuel before entering the combustion chamber to form an activated
complex with lowered activation energy such that more fuel molecules react to form a fuel mixture consisting of a ratio of fuel species of
aliphatic to aromatics that have improved combustion.

The Rentar technology causes clustered fuel molecules to temporarily repulse each other resulting in more surface area of the fuel
molecules being exposed to oxygen at the point of combustion. Other studies document how the Rentar technology causes “Aromatics”
to form, which creates Hydrogen Gas, which works with the Oxygen at the point of combustion to interact or better surround the
“dispersed” fuel molecules to achieve a more complete combustion. Separating the fuel molecules allows Oxygen and H2 to better
surround the dispersed molecules. The turbulence caused by the Rentar Fuel Catalyst enhances the above described reactions.
Hydrogen is released when the molecular structure changes from saturated to none saturated (aromatic). The resulting double bond
provides an addition combustion source to the fuel.
___________________________

As fuel passes over the chemical complex of


catalytic metals and rare earth elements, fuel
molecules form a classical activated chemical
complex with lowered activation energy, which
lead some of the fuel molecules to react
Hydrogen Release
The RFC causes a change in the ratio of aliphatic
or paraffinic contents of the fuel to aromatics
(i.e. saturated straight-chain to unsaturated ring Classic Catalytic Reaction:
compounds) which result in the release of A+B {AB*} C+D
hydrogen gas Reactants Activated Product
Lower Fuel Vapor Density Complex
The RFC lowers the fuel vapor density as a result
of small amounts of moisture that exists within
diesel fuel which helps to create a galvanic
effect which is created between the different Mexane Benzene+Hydrogen
metals in the RFC CH3CH2CH2CH2CH2CH3 C6H6 + 7H2
Reduced NOx
Better combustion usually requires high
temperature, which lead to more NOx
generation, the RFC combusts at a lower R-(CH2)-R+O2+N2 CO2+CO+H2O+NOx (Unbalanced)
temperature and thus decreases the formation CO+NOx CO2+N2 (Unbalanced)
of NOx
Simple Installation
on a Webster
Burner at a Boston,
MA Area School
__________________

15 Minute Installation
Fuel Savings at a Boston Area Regional High School
Fuel Cost
Heating Degree Gallons of Fuel Fuel Cost
Time Trial
Days Used
Gal HDD Savings $1.99 / Gal
using 7.87
Gal/HDD

BASELINE Total
1457 11461 7.87 $22,807 $22,807
Nov – Dec 2006 Savings
AFTER INSTALL
Jan – Feb 2007
2368 13778 5.82 26% $27,418 $37,068 $9,650
Gallons
Heating Used Per
Degree Heating Degree Days HDD
Gallons Used Per Heating Degree Day
Days

26% Fuel Savings with


the RENTAR.
A $9,650 savings and a
34 day return on
investment!

Gallons
of Fuel Gallons of Fuel Oil Used Comparing Cost Of Fuel Used With & Without RENTAR
Used

Jan - Feb Test Period


$9,650 savings was
achieved with RENTAR
installed in just two months
of use
Laboratory Test
Conducted by Leading Manufacturer of Commercial, Industrial and Institutional Burners

Oil Heating Value BTU lb 19,340


Input-Output Efficiency Improvement 14.9% Oil Specific Gravity 0.8708

Rentar Furnace Catalyst

STD RENTAR
TEST DURATION, MINUTES 120 120

WATER METER STOP FT3 2,722,928.50 2,723,071.38

WATER METER START FT3 2,722,858.50 2,722,990.00

FUEL STOP, LBS 355.38 360.32

FUEL START, LBS 0.00 0.00

H2O CONSUMED, FT3 70.00 81.38

#2 OIL CONSUMED, LBS 355.38 360.32

H2O CONSUMED, LBS 4,360.86 5,069.81

DELTA H STEAM & FEED H2O 1,148.15 1,148.15

OUTPUT, BTU'S 5,006,921.41 5,820,903.78

OUTPUT, AVG BTU/HR 2,503,460.70 2,910,451.89

INPUT, BTU'S 6,873,049.20 6,968,492.10

INPUT, AVG BTU/HR 3,436,524.60 3,484,246.05

INPUT-OUTPUT EFFICIENCY, % 72.85 83.53

Avg Stack Temperature, oF 494.8 497.4


Avg Ambient Temperature, oF 85 85
Avg Flue Gas O2, % 4.6 4.1
Avg Flue Gas CO2, % 12.22 12.6
Avg Flue Gas CO, ppmv 0.1 0
Avg NOx (corr to 3% O2), ppmv 100.2 96.9
Avg Smoke Spot <1 <1
STACK LOSS EFFICIENCY, % 82.74 82.96
RENTAR FURNACE CATALYST – FIELD BUILDING REPORT
Broadway Towers. Total fuel savings from Oct. 2004 thru Jan. 2005: ..............$18,477.80 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 59,314 42,516 28.3% 27.2%
NOx Reduction 47% on a ppm basis
Edward L. Grant Avenue. Total fuel savings from Oct. 2004 thru Jan. .……… $6,924.16 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
4 oil 21,891 16,307 25.5% 23.0%
NOx Reduction 42.7% on a ppm basis
West 177th Street. Total fuel savings from Oct. 2004 thru Jan. 2005: .............…$6,897.00 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 21,358 15,088 29.4% 27.6%
Broadway. Total fuel savings from Oct. 2004 thru Jan.2005:………… $6,398.40 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
4 oil 16,970 11,810 30.4% 28.6%
West 174th Street. Total fuel savings from Oct. 2004 thru Jan.2005:……….…. $5,526.40 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 23,549 18,525 21.3% 19.4%
NOx Reduction 52.3% on a ppm basis
Broadway. Total fuel savings from Oct. 2004 thru Jan. 2005 ………………… $3,968.00 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 16,244 13,044 9.7% 17.7%
West 184th Street. Total fuel savings from Oct. 2004 thru Jan. 2005 …….... $3,882.44 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
4 oil 18,469 15,338 17% 15.2%
East 169th Street. Total fuel savings from Oct. 2004 thru Jan. 2005 ………..…. $3,834.70 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
2 oil 20,977 18,503 11.8% 9%
Isham Street. Total fuel savings from Oct. 2004 thru Jan. 2005 …………..……. $3,733.40 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 21,637 18,243 15.7% 13.5%
Riverside Drive. Total fuel savings from Oct. 2004 thru Jan. 2005 …...............…..$2,796.20 SAVINGS
Fuel Readings: 10/03-2/04 10/04-2/05 Savings Degree Day Net Savings
6 oil 24,420 21,878 10.4% 8.6%
Rentar Furnace Catalyst

Cleaver Brooks 100 Hp


Rentar Furnace Catalyst

Power Flame in Blast Tube


Rentar Furnace Catalyst

Power Flame
Rentar Furnace Catalyst

Cleaver Brooks
Genset with Cat 3306 | Saipan | 5.3% improvement in fuel efficiency
Genset with Cat 3516| Alaska | 6.1% improvement in fuel efficiency
Rentar Fuel Catalyst
11586 Pierson Road * West Palm Beach, Florida 33414
(561-333-3411* Email (Furnace@Rentar.com) * Website: www.Rentar.com