Professional Documents
Culture Documents
GTAC Guidelines
Searching for related Documentation
and articles
Safety Manager
Revision:
Revision: 2_01
2_01
Date:
Date: 23
23 April
April 2018
2018
Owner:
Owner: HPS
HPS Technical
Technical Support
Support
Intended
Intended Use:
Use: www.honeywellprocess.com/Support
www.honeywellprocess.com/Support Portal
Portal
SM
Migration
Phone
No
Create service
Answers found
Request
Online Yes
End
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Installation and Upgrade Guide, EP-SM.MAN.6277:
Section Hardware Replacements and Upgrades
- Safety Manager Hardware Reference, EP-SM.MAN.6284
- Safety Manager Safety Manual EP-SM.MAN.6283: section 3, Safety Manager fault detection and reaction
- Article: 68211 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- SDO, Safe Digital Output module - QPP, QPP-0001, QPP-0002, Quad Processor Pack
- SAO, Safe Analog Output Module - USI, USI-0001, USI-0002, Universal Safety Interface
- SDI, Safe Digital Input module - BKM, BKM-0001, Battery and Key switch Module
- SAI, Safe Analog Input module - PSU-240516, Power Supply Unit 24/5 Vdc, 16 A
- USIO, Universal Safe IO - FTA, Field Termination Assembly module
- RUSIO, Remote Universal Safe IO - RUSLS, Remote Universal Safe Logic Solver
Predefined Topic: (Click here to go to the support portal, Search Knowledge Base)
- TopicSMCPChassis
User documentation (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284: Section Control Processor modules
- Safety Manager Software Reference, EP-SM.MAN.6285:
Section Safety Builder configuration tools - hardware configurator,
Appendix: Diagnostic information
- Safety Manager Safety Manual EP-SM.MAN.6283: section 3, Safety Manager fault detection and reaction
- Article: 25323 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- QPP, QPP-0001, QPP-0002, Quad Processor Pack - BKM, BKM-0001, Battery and Key switch Module
- USI, USI-0001, USI-0002, Universal Safety Interface - PSU-240516, Power Supply Unit 24/5 Vdc, 16 A
Loop Fault(s)
Predefined Topic: (Click here to go to the support portal, Search Knowledge Base)
- TopicSMOnline , TopicSMSpecialfunction
User documentation (Click here to go to the release support information hyperlink page)
- Safety Manager Software Reference, EP-SM.MAN.6285:
Appendix: Diagnostic information
- Safety Manager Safety Manual EP-SM.MAN.6283: section 3, Safety Manager fault detection and reaction
Options to include in search: (Click here to go to the page with searching tips)
- QPP, QPP-0001, QPP-0002, Quad Processor Pack - BKM, BKM-0001, Battery and Key switch Module
- USI, USI-0001, USI-0002, Universal Safety Interface - PSU-240516, Power Supply Unit 24/5 Vdc, 16 A
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284:
Section Input modules, Section Input converter modules
Section Output modules, Section Output converter modules
- Safety Manager Troubleshooting and Maintenance Guide EP-SM.MAN.6282
- Safety Manager Software Reference, EP-SM.MAN.6285:
Section Safety Builder configuration tools - hardware configurator
- Safety Manager Safety Manual EP-SM.MAN.6283: section 3, Safety Manager fault detection and reaction
- Article: 25323 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- SDO, Digital Output module, SDO, SAO, SDO-0824, SDOL-0424, SDO-0424, SDO-0448,
SDOL-0448, DO-1224, DO-1624, SDO-04110
- SAO, Analog Output Module: SAO, SAO-0220m
- SDI, Digital Input module, SDI-1624, SDIL-1608, SDI-1648
- SAI, Analog Input module, SAI-1620m, SAI-0410
- Output converter modules, BSDOL-04UNI, setting “S”, setting “L”, setting “M”, setting “H”, None
- Input converter modules, BN-1608, BSN-1608, BSDI-16UNI, BSAI-1620mE, BSAI-04x + BSDIL-0426
- A.R.T. (Advanced Redundancy Technology)
Predefined Topic: (Click here to go to the support portal, Search Knowledge Base)
- TopicSMUSIO
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284: Section SM universal IO modules
- Safety Manager Troubleshooting and Maintenance Guide EP-SM.MAN.6282
- Safety Manager Software Reference, EP-SM.MAN.6285:
Section Safety Builder configuration tools - hardware configurator
- Safety Manager Safety Manual EP-SM.MAN.6283:
section 3, Safety Manager fault detection and reaction
- Article: 25323 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- USIO, Universal Safety IO
- RUSIO, Remote Universal Safety IO, FC-RUSLS-3224
- RUSLS, Remote Universal Safety Logic Solver, FC-RUSIO-3224
Predefined Topic: (Click here to go to the support portal, Search Knowledge Base)
- TopicSMSpecialfunction
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284:
Section Modules for special functions
- Article: 25323 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- ELD - Earth Leakage Detector (ELD)
- TELD - FC-TELD-0001, Earth Leakage Detector terminal (For USIO)
- 10310 - 3rd party equipment
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284: Section Field Termination Assembly modules
- Safety Manager Installation and Upgrade Guide EP-SM.MAN.6277: Section Connection of external cables
Options to include in search: (Click here to go to the page with searching tips)
Input FTAs
-TSDI-1624, Safe digital input FTA (24 Vdc, 16 channels)
-TSDI-1648, Safe digital input FTA (48 Vdc, 16 channels)
-TSDI-16UNI, Safe digital input FTA (24/48 Vdc, NAMUR, 16 channels)
-TSDI-1624C,,Safe current-limited digital input FTA (24 Vdc, 16 channels)
-TSDI-16115, Safe active/passive digital input FTA (115 Vac/dc, 16 channels)
-TIDI-1624, Non-safe Isolated passive digital input FTA (16 channels)
-TSAI-0410, Safe analog input FTA (4 channels)
-TSAI-1620m, Safe 0-20 mA and 4-20 mA analog input FTA (16 channels)
-TSHART-1620m, Safe 0-20 mA and 4-20 mA analog input FTA with HART interface (16 channels)
-TSGAS-1624, Safe gas / flame detector input FTA (0-20 mA, 16 channels)
-TSGASH-1624, Safe gas/flame detector input FTA with HART interface (0-20 mA, 16 channels)
-TSGASH-1624P, Safe gas/flame detector input FTA with HART interface (0-20 mA,16 channels)
-TSFIRE-1624, Safe fire detector input FTA with line monitoring (24 Vdc, 16 channels)
Output FTAs
-TSDO-0824, Safe digital output FTA (24 Vdc, 8 channels)
-TSDO-0824C, Conformal coated safe digital output FTA, current limited (24 Vdc, 8 channels)
-TDOL-0724, Line-monitored relay contact digital output (7 channels, 24Vdc)
-TDOL-0724P, Line-monitored relay contact digital output (7 channels, 24Vdc)
-TDOL-0724U, Line-monitored relay contact digital output (7 channels, 24Vdc, USIO)
-TDOL-07120, Line-monitored relay contact digital output (7 channels, 120Vac/120Vdc)
-TSDO-0424, Safe digital output FTA (24 Vdc, 4 channels)
-TSDO-04UNI, Safe digital output FTA (24/48/110 Vdc, 4 channels)
-TSDOL-0424C, Conformal-coated safe digital output FTA, current limited, loop monitored (24 Vdc, 4 channels)
-TDO-1624, Non-safe digital output FTA (24 Vdc, 16 channels)
-TSRO-0824, Safe dry digital output FTA for SIL3 applications (8 channels)
-TRO-0824, Non-safe dry digital output FTA (8 channels, NO/NC)
-TRO-1024, Non-safe dry digital output (relay contact) FTA (10 channels)
-TSAO-0220m, Safe analog output FTA (0(4)-20 mA, 2 channels)
-TSAOH-0220m, Safe analog output FTA with HART interface (0-20mA, 2 channels)
Special FTAs:
-TPSU-2430, 24 Vdc to 30 Vdc / 1 A converter
-TSPKUNI-1624, Sub-D to Powered Knife terminals FTA (USIO,16ch)
-DCOM-232/485, RS232/485 communication FTA
-SDW-550 EC, 5 port HSE communication FTA or "switch"
-MTL 24571, Single channel ethernet surge protector
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Hardware Reference, EP-SM.MAN.6284:
Section Power supplies
Section Power distribution
Section 5 Volt and watchdog distribution
- Safety Manager Installation and Upgrade Guide EP-SM.MAN.6277: Section Connection of external cable
Options to include in search: (Click here to go to the page with searching tips)
- Power - Grounding - 24VDC - 5VDC - Watchdog
Power Supply:
- PSU-UNI2450U, 25—28 Vdc Power supply (1200 W) – UL508 approved
- PSU-UNI4825U, 48 Vdc Power supply (1200 W) – UL508 approved
- PSU-UNI6020U, 60 Vdc Power supply (1200 W) – UL508 approved
- PSU-UNI11011U, 110 Vdc Power supply (1200 W) – UL508 approved
- 1200 S 24 P067, 24 Vdc Power supply (45 A) ), Obselete
- 1200 S 48 P073, 48 Vdc Power supply (22.5 A), Obselete
- RUSPSU-R, Redundant Power Supply assembly 24 Vdc, 12 A (USIO)
- RUSPSU-S, Non-redundant Power Supply assembly 24 Vdc, 12 A (USIO)
- PSU-UNI2412, Power Supply unit 24 Vdc, 12 A (USIO)
- PSUTA-0001, Power supply carrier 0001
Power feeder
- FS-FEEDER-24R, 24 Vdc Feeder unit redundant - FS-FEEDER-48R, 48 Vdc Feeder unit redundant
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Software Reference EP-SM.MAN.6285:
Section Network Configurator
Appendix A Communication
- Communication Best Practice EP-M.MAN.6844
- Safety Manager Overview Guide EP-SM.MAN.6275
- Safety Manager Safety Manual EP-SM.MAN.6283: section 4, Safety Manager special functions - SafeNet communication
- Safety Manager System Administration Guide EP-SM.MAN.6281
Options to include in search: (Click here to go to the page with searching tips)
- External communication
- Internal communication
- Network
- SafeNet
- DCS
- Experion
- CDA
- PCDI
- Safety Manager with advanced Experion integration
- Physical network
- Logical view
- Safety Builder
- Modbus
- Serial
- RS485
- RS232
- Ethernet
- Autonegotiate
- 100MB
- Full Duplex
- External Clock Source
- Time synchronisation
- FDM
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Software Reference EP-SM.MAN.6285:
Section Safety Builder Configuration Tools – Point Configurator
Section Safety Manager system points
Section Safety Manager Reset Option
Section Point Properties
Section Import and Export
Safety Manager Safety Manual EP-SM.MAN.6283: section 3, Safety Manager fault detection and reaction
Options to include in search: (Click here to go to the page with searching tips)
- Point
- Tagnumber
- Point properties
- Fault Reaction
- COM
- SYS
Application
Predefined Topic: (Click here to go to the support portal, Search Knowledge Base)
- TopicSMAPPL
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Software Reference EP-SM.MAN.6285:
Section Safety Builder Configuration Tools – Application Editor
Section Appendix B, FLD symbols
Section Safety Manager Reset Option
Section Point Properties
Section Import and Export
- Safety Manager Safety Manual EP-SM.MAN.6283:
Section 3, Safety Manager fault detection and reaction
- Safety Manager On-line Modification Guide EP-SM.MAN.6350 section 4, On-Line Modification - Important Considerations
Options to include in search: (Click here to go to the page with searching tips)
- symbols (Timer, AND, OR, XOR….)
- Copy Sheet , Import FLD
- On-sheet reference, Of-sheet reference
- Latch
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Hardware Reference EP-SM.MAN.6284
- Safety Manager Safety Manual EP-SM.MAN.6283
Options to include in search: (Click here to go to the page with searching tips)
- Instrumented Protective Systems (IPS)
- Safety Interlocks System (SIS)
- Safety Related Systems (SRS)
- Emergency Shut-down Systems (ESD)
- Burner Management Systems (BMS)
- High Integrity (Pressure) Protection System (HIPS)
- Safeguarding System (SGS)
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Safety Manual EP-SM.MAN.6283
- Hardware Reference EP-SM.MAN.6284
- Section Field Termination Assembly modules:
TDOL-0724, Line-monitored relay contact digital output (7 channels, 24Vdc), Chassis IO
TDOL-0724P, Line-monitored relay contact digital output (7 channels, 24Vdc), Chassis IO
TDOL-0724U, Line-monitored relay contact digital output (7 channels, 24Vdc, RUSIO), USIO
TDOL-07120, Line-monitored relay contact digital output (7 channels, 120Vac/120Vdc), Chassis IO
TSFIRE-1624, Safe fire detector input FTA with line monitoring (24 Vdc, 16 channels), Chassis IO
TSGAS-1624, Safe gas / flame detector input FTA (0-20 mA, 16 channels), , Chassis IO
TSGASH-1624, Safe gas/flame detector input FTA with HART interface (0-20 mA, 16 channels), Chassis IO
TSGASH-1624P, Safe gas/flame detector input FTA with HART interface (0-20 mA, 16 channels), , Chassis IO
Options to include in search: (Click here to go to the page with searching tips)
- FGS
- F&G
- Detector
- Flame
- Gas
- Fire
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- Safety Manager Software Reference EP-SM.MAN.6285:
Section Safety Builder on-line tools
Appendix I, Diagnostic information
- Safety Manager Installation and Upgrade Guide EP-SM.MAN.6277:
Section Normal operation
Section Software loading and upgrading
Section Diagnostic information
- Safety Manager On-line Modification Guide EP-SM.MAN.6350
- Article: 68211 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- Online
- Application Viewer
- Point Viewer
- Controller management
- Communication statistics
- link status
- OLM (Online Modification)
- Force
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
User documentation: (Click here to go to the release support information hyperlink page)
- SCN of Safety Manager version to be upgraded
- Safety Manager Installation and Upgrade Guide EP-SM.MAN.6277:
- Section Normal operation
- Software loading and upgrading
- Diagnostic information
- Safety Manager On-line Modification Guide EP-SM.MAN.6350
- Article: 68211 - Safety Manager error-code list
Options to include in search: (Click here to go to the page with searching tips)
- Online Modification
- OLM (Online Modification)
- Consideration
- Limitation
User documentation: (Click here to go to the release support information hyperlink page)
- Safety manager user documentation R160 and Higher
Options to include in search: (Click here to go to the page with searching tips)
- FSC-SM Migration
- Note: In order to access features of the Support Portal, you will need to login.
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
- Note: In order to access features of the Support Portal, you will need to login.
Back to Home page
- Click Here to find Tips to improve search results while searching in Support Community - knowledge base
2) Select Support: