You are on page 1of 52

PowerFlow™ D03

Directional Control Valves

5505 West 123rd Street • Savage, MN 55378-1299 • Ph: 952.895.6400 • Fax: 952.895.6444 • www.continentalhydraulics.com
Form No. 1004532 Rev. 6/08 © 2008 Continental Hydraulics. All rights reserved. Product specifications and appearance are subject to change without notice.
Directional control valves DIRECTIONAL CONTROL VALVES
PRODUCT OVERVIEW ISO 9001:2000 CERTIFIED

Specifications
• Mounting: Sub-plate or manifold mount in D03, D05, When reliability and Product Lineup power and 3 gallon tank size,
D08, and D10 configurations; conforming to NFPA and durability count....count on to 100 horse power, 330 gallon
ANSI/ISO Standards Pumps
Continental Hydraulics! tank, straight out of the catalog.
• PVR Vane Pumps, rugged duty
• Flow: Continental Hydraulics is a world • Custom Designed and larger
pumps for medium pressure
D03 – Up to 20 GPM D05 – Up to 35 GPM leading hydraulic components units to match your application,
D08 – Up to 150 GPM D10 – Up to 275 GPM
applications
manufacturer. Since 1955 we’ve exactly
been designing and manufacturing • PVX Vane Pumps, quiet pumps for
• Pressure: Up to 5,000 PSI higher pressure applications
hydraulic equipment to withstand
• Seals: Viton® • HPV Piston Pumps, efficient pumps Continental Hydraulics manufactured
the most demanding applications.
for higher pressure applications components are covered by a 3 year
• Fluids: Petroleum-base, mostphosphate esters, Continental Hydraulics is ISO
Features & Benefits warranty!
water based fluids (not more than 40% water) 9001:2000 Certified.
• High flow rates and low pressure drops reduce heat
generation and increase efficiency
and water glycol Valves
• Premium bore honing reduces crossport leakage Our Approach • D03/5/8/10 Directional Control How can we help you?
• Interchangeable spools for simplified field maintenance, Options & Accessories Continental Hydraulics welcomes Valves, for a variety of applications Contact your Continental
and eliminate the need to change valve body when • Solenoid, lever, air, soft shift and cam control operators • D03/5/8 Proportional Control Hydraulics representative for
the opportunity to work with
changing spools • Low watt power solutions to your toughest
you to help design your hydraulic Valves offer more control options,
• Below center-line mounting bolt position reduces body • Wide variety of electrical connections hydraulics problems. Whether it’s
distortion that causes sticky spools • Hazardous environment solenoids (dust and gas system from the ground up. Our from programmable On-board
amplifiers to panel and Euro card reducing your operating expenses,
• Two-pin plug-in or DIN connection coils allow for quick classifications) Application specialists and our
mounts. or increasing your production
replacement reducing down time • Wash down trained local support Distributors
capability, you can count on
• All valves with optional electric box include indicator • Anti-shock option can advise you of the most efficient, • Modular Stack Valves for controlling Continental Hydraulics!
lights and electrical transorb surge suppression for coil • Patented DeAccelatrol® motion control valve cost-effective components available flows and pressures in industrial
protection and increased • Wide variety of bolt and stud kits for mounting modular off the shelf, or work with you on and/or mobile applications
valve life stack valves custom designs to meet your needs.
• Sealed wet armature solenoids provide maximum • Spool indication switches • Cartridge Valves for controlling
protection against moisture, corrosion and dirt. • Double redundant monitoring packages and lockout valves flows and pressures in compact
Product Characteristics applications
Product Description Continental Hydraulic’s products
Continental Hydraulics PowrFlow Directional Control

In the event of a component are designed to provide maximum Power Units
Valves offer some of the highest flow and pressure ratings in or system failure, the double overall value. Reliability, durability, • Little Champ series for smaller and/
the industry today, making them the perfect choice whether redundant valve option and efficiency are designed in. Ease or economical applications
you are designing a new system or just simply trying to get shuts down the system in a of maintenance, quiet operation and
more out of your current system. Superior performance and controlled manner to help avoid • JIC and L-Shape series for larger
low operating costs are common
durability makes these Directional Control Valves a great damage and injury. industrial applications
design features.
investment. • Available from fractional horse
With 12 standard spools, numerous specialty spools and 7
functions, these directional control valves can be ordered to
meet the specific needs of your applications.

Precise bore honing and spool grinding results in less


cross-port leakage and less wasted energy. Spools also Continental Hydraulics
utilize U-groove machining making them more tolerant of valves are designed to use
interchangeable spools for
contaminants than v-groove designs resulting in less spool
simplified field maintenance.
hang-ups.

Controller options include solenoid, lever, air, soft shift and


cam operators.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES Because Continental Hydraulics is continually improving its products, specifications and appearance are subject to change without notice.
TABLE OF CONTENTS
DIRECTIONAL CONTROL VALVE CATALOG

Page #

Terminology and General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

VSD03M
Solenoid Actuated, Direct Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13

VS5M
Solenoid Operated (Anti-Shock) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-17
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Electrical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

VMD03M
Lever Actuated, Manually Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

VAD03M
Air Actuated, Direct Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-26
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

VCD03M
Cam Actuated, Direct Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-30
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

VSD03M Special Application Products


Hazardous Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-35
Explosion-Proof Solenoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-39
Ordering Code Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Double Redundant Kit Dual Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 41-42

NFPA
Mounting Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43-44

Valve Bolt Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 1


TERMINOLOGY & GENERAL SPECIFICATIONS
DIRECTIONAL CONTROL VALVES

FEATURES LEVER ACTUATED


• Lever boot keeps contaminants from linkage.
SOLENOID ACTUATED • Lever connects directly to spool for positive hold.
• CSA certified (D03, D05, D08 sizes). • Detent option for positive hold.
• CE approved (D03, D05, D0 8 and D10 sizes). • Internal actuator parts are electro-filmed to
• Wet armature solenoids: resist corrosion.
- 2-pin plug-in coils or DIN (D03, D05, D08, D10
sizes). AIR ACTUATED
- Solenoid failures greatly reduced. • Wide operating range of air pilot pressure.
- Standard and low amp coils available. • Urethane sealing gland on air piston permits very
- High temperature elements are isolated from low air flow rates.
direct human contact. • Excellent control of spool shift rate.
- No oil leakage into electrical cavity. • Air operator internal parts are electro-filmed to
- Fast and easy solenoid replacement. resist corrosion.
- Continuous duty-rated coils.
• No dynamic seals eliminate external oil leakages.
• Electrical quick disconnects as factory installed
GENERAL SPECIFICATIONS
or field installed options.
• 3-, 4- and 5-pin sealed connectors per ANSI RECOMMENDED FLUID
recommended standard B93.55M-1981. • Petroleum.
• Built-in lights, terminals and surge suppressor • Water-based fluids (not more than 40% water).
• Access to mounting bolts without entering • Most phosphate esters.
electrical box. • Other fluids are acceptable, but special O-rings may
• Mounting bolt heads are below spool centerline be required.
to prevent body distortion and spool stick. • Viton seals are standard.

CAM ACTUATED
• Bronze bearing push-rod for increased life.
• Urethane wiper eliminates contamination
from actuator.
• Internal actuator parts are electro-filmed to resist
corrosion.

2 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


TERMINOLOGY & GENERAL SPECIFICATIONS
DIRECTIONAL CONTROL VALVES

FLUID TEMPERATURE RANGE GENERAL INFORMATION


Fluid temperature up to 200° F. will not appreciably
affect valve performance, however, from a safety VALVE OPERATION
standpoint, temperatures above 130° F. are not
recommended. Spring centered and spring offset valve types will
be spring positioned unless actuated continuously.
Detented, no spring valves may be actuated
RECOMMENDED OPERATING VISCOSITY momentarily. When the operator is deactuated, the
80 to 350 SUS. spool will remain shifted provided there is no severe
shock, vibration, or pressure transients.
FLUID OPERATING VISCOSITY
Acceptable start-up viscosity to 1500 SUS. PRESSURE SURGES
Minimum viscosity to 30 SUS. Pressure surges in a common tank line serving these
and other valves can be large enough to cause
inadvertent shifting of these valves. This is particularly
FILTRATION critical in no-spring detented type valves. Separate
ISO 18/16/13. tank lines may be necessary. Maximum pressure
rating on solenoid operated valve tank ports includes
surges.
MOUNTING POSITION
Optional; horizontal preferred.
SILTING
Any sliding spool valve, if held shifted under pressure
NFPA FLOW PATH/ACTUATING PATTERN for long periods of time, may stick and not spring
SOLENOID, AIR AND OIL ACTUATED: return due to fluid residue formation. The valve
Actuating operator (a): connects flow to cylinder should be cycled periodically to prevent this from
port A. happening.
Actuating operator (b): connects flow to cylinder
port B. RESPONSE TIME
CAM ACTUATED: Response times of air actuated valves are dependent
Activated — connects flow to cylinder port B. on air flow rate and pressure supplied to the operator.
Released — connects flow to cylinder port A. Response times of hydraulic actuated valves will vary
with pilot line diameter and length, pilot pressure, pilot
LEVER ACTUATED: control valve shift time, pilot oil flow rate, and fluid
viscosity.
Push— connects flow to cylinder port A.
Pull — connects flow to cylinder port B.

NOTE:
The NFPA flow path/actuating pattern is reversed for
Spool Code L.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 3


VSD03M
SOLENOID ACTUATED, DIRECT OPERATED

Physical Specifications

Weight: (No modifications)


VSD03M - 1, 5 & 6 Single Operators:
3.2 lbs. (1.45 kg)
VSD03M - 2 & 3 Dual Operators:
3.9 lbs. (1.77 kg)

Size: Conforms to American National Standard,


ANSI B93.7M, D03 Size Mounting Interface
(ISO 4401 size 03 / CETOP 3 / NG 6)

Basic Valve Operations Operating Specifications


VSD03M-1 Single solenoid,
2 position, spring offset Flow capacity:
Maximum flows up to 20 GPM (76 lpm)

Maximum operating pressure:


P, A and B ports - 5000 PSI (345 bar)

Maximum tank line back pressure:


VSD03M-2 Double solenoid, - 3000 PSI (207 bar) including transient
2 position, no spring, detented
Recommended fluid:
Any hydraulic fluid compatible with
selected seal materials

Fluid temperature range :


Fluid temperatures up to 200˚F (93˚C) will not
VSD03M-3 Double solenoid, appreciably affect valve performance,
3 position, spring centered however, from a safety standpoint,
temperatures above 130˚F (54˚C) are not
recommended.

Recommended fluid:
Operating viscosity ranges 80 to 350 SUS at
VSD03M-5 Single solenoid, 2 position, operating temperature.
spring centered
Filtration recommendations:
ISO CODE 18/16/13

Cycle rate:
A.C. solenoids -Up to 400 cycle/minute
VSD03M-6 Single solenoid, 2 position, D.C. solenoids -Up to 300 cycle/minute
energize to center
Mounting – Unrestricted:
(Detented models; horizontal preferred)

Recommended mounting bolt torque:


4-5 lb.-ft. (.55 to .70 kg-m)

Duty cycle: Continuous

4 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M
SOLENOID ACTUATED, DIRECT OPERATED

TYPICAL ELECTRICAL CHARACTERISTICS

INRUSH HOLDING
VOLTAGE & VOLTAGE CURRENT HOLDING CURRENT HOLDING
FREQUENCY LIMITS (AMPS) CURRENT MIN. VOLT. POWER

SOLENOID
VOLTS - Hz. MIN. - MAX. MAX. (AMP) (AMP) (WATTS)
CODE
120 - 60 108 - 126 .49 .39 24
33L, 60L 2.10
110 - 50 99 - 116 .58 .45 26
240 - 60 216 - 252 .24 .19 24
34L, 61L 1.10
220 - 50 198 - 231 .29 .22 26
120 - 60 108 - 132 .19 .15 10
39L, 68L 1.10
110 - 50 99 - 121 .21 .17 10
42L, 70L 24 DC 21 - 26 1.00 1.00 .88 24
44L, 75L 12 DC 10 - 13 2.00 2.00 1.67 24

CONNECTION BOX
DIMENSIONS
NFPA D03 SIZE
(Formerly D01)

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 5


VSD03M
SOLENOID ACTUATED, DIRECT OPERATED

DIN CONNECTIONS

6 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M WASH DOWN OPTION
SOLENOID ACTUATED, DIRECT OPERATED

The main changes to the standard D03 valve include:

1. Addition of o-rings to seal the mounting bolt access


holes between the electrical box and valve body.

2. Thicker cover gasket made of 40D nitrile to


protect against direct spray. The softer material
compresses more to provide a tighter seal.

3. .093” Thick gaskets made of 50D nitrile to seal


the solenoid pins where they pass through the
electrical box. Added compression provides better
protection from direct spray. These replace the
DESCRIPTION standard o-rings.
Wash down option with electrical box, rated for IP65.
Tested by CSA. The hose down test consisted 4. RTV sealant added around core tube area.
spraying the valve and enclosure with 45 to 65 GPM
of water from a 25mm nozzle for 5 minutes. The 5. Solid Anodized Aluminum Cover (no bolt access
water stream was directed at the enclosure seams holes) replaces the standard plastic cover for
from a distance of 3 meters and moved along the better sealing and chemical resistance.
joints or surface at a minimum rate of 6mm/s or
1.65in/s.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 7


VSD03M
SPOOL DESCRIPTION CHART

SPOOL DESCRIPTION

CODE SYMBOL SPOOL FUNCTION CENTER POSITION CROSSOVER



A All ports blocked All ports blocked

B All ports open All ports open



All ports blocked,
P & A blocked
E or P & A blocked
B to T
B to T

P blocked P blocked
F
A & B to T A or B to T
P blocked P blocked
F1 A & B restricted A or B restricted
to T to T
P to A or B
P to A & B
G T & A or B
T blocked
blocked

P to A & T
H All ports open
B blocked

All ports blocked,
P to B
J or P to B,
A & T blocked
A & T blocked
All ports blocked,
P & B blocked
K or P & B blocked,
A to T
A to T

P to T All ports open,
L
A & B blocked restricted

All ports blocked,
P to A
N or P to A,
B & T blocked
B & T blocked

P to B & T
Q All ports open
A blocked

All ports blocked
AC-** All ports blocked
Tappered Spool

P blocked
FC-** A & B to T All ports blocked
Tapped Spool

8 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M
MAXIMUM RECOMMENDED FLOW RATINGS

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 9


VSD03M
FLOW / PRESSURE DROP CURVES

Note: See Page 9 for maximum flow rates.

10 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M
FLOW / PRESSURE DROP CURVES

Spool selection notes

Spool shift characteristics are a common cause of shock in a hydraulic system. When a valve shifts, large
decompression and pressure differential combine to create large surges of shock. This is usually in the form of
mechanical vibration and excessive pressure spikes, causing premature failure of system components.
Most of the standard directional control valves designs use spools with sharp edges and as the spool is shifted
the opening rate of the area for passage of oil is very fast. Conversely when the valve is shut off the flow path is
at a sharp rate as well. This sudden change creates many of the pressure spikes we see in the system.

Valve spool type selection is critical, pay close attention to the cross-over or transition conditions when the valve
is shifted form one condition to another. These transitional conditions play a large role in the level of the spike,
as well as helping to control the decompression of stored energy.

Continental Hydraulics offers the above metering spools for use in the standard solenoid valves. This allows for
selecting a spool that better matches the flow requirements, metering characteristics and transition conditions.
Metering spools in a standard solenoid valves, allow the upstream and downstream sides to have a more
gradual rate of change. Matching of the spools to the system requirements encourage a softer shock to the
system. By selecting this “metering” style of spool over the “sharp edge” style of spool, in most cases you may
reduce some of the transitional shocks.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 11


VSD03M
ORDERING CODE INFORMATION

SELECT SELECT SELECT


ONE ONE ON

VSD03M

BASIC VALVE FUNCTION SPOOL SEAL


SEE S POOL SEE SEE
NOTE CODE DE S CR IPTION S YMBOL AVLBL NOTE CODE S YMBOL NOTE CODE DESCRIPTION

SINGLE OPERATOR G VITON


1 2 POSITION A,B A 10 A BUNA
SPRING OFFSET 10, 11, 15 N N E OPR E NE
DOUBLE OPERATOR
2 2 POSITION A,B B
DETENT NO SPRING
DOUBLE OPERATOR A B
ALL
4 3 3 POSITION CTR 7 E
SPOOLS
SPRING CENTER P T

SINGLE OPERATOR
ALL
4 5 2 POSITION CTR F
SPOOLS
SPRING CENTERED
SINGLE OPERATOR
6 2 POSITION SPRING OFFSET CTR A,B, F, G, L 7 FS
ENERGIZE TO CENTER

7 F1

NOTES:
1 NOT AVAILABLE ON DOUBLE S OLE NOID VALVE S . 7 H
2 E LE CTR ICAL BOX OPTION R E QUIR E D ON 2 PIN S OLE NOIDS .
A B
3 BOX OPTION "HD" AVAILABLE ONLY ON CODE 50, 52 COILS .
7 J
4 OPERATOR IDENTIFICATIONREVERSED WITH "L" SPOOL:
P T
5 AVAILABLE ON D.C. ONLY AT THIS TIME.
A B
6 NOT AVAILABLE ON HD ELECTRICAL OPTION. (VITON SEALS ONLY) 7 K
7 S POOL NOT AVAILABLE WITH LOW FOR CE S OLE NOIDS P T
8 CONNE CTOR CONFOR MS TO ANS I/B93.55M-1981
9 S E E WIR ING DIAGR AM FOR PIN CALL OUTS 4 L
10 TANK PORT RATING 1500 PSI
A B
11 AC SOLENOIDS ONLY.
12 AVAILABLE ON FUNCTION CODE 1 ONLY. 7 N
P T
13 AVAILABLE ONLY WITH B5A / B5H BOX OPTIONS
14 AVAILABLE ONLY WITH TOP ELECTRIC CONNECTION BOX
7 Q
15 NOT CSA APPROVED
AC-09
5 AC-16
AC-26
FC-09
5 FC-16
FC-26

12 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M
ORDERING CODE INFORMATION

SELECT SELECT SELECT SELECT DESIGN


AS REQ'D AS REQ’D AS REQ’D ONE LETTER

MECHANICAL OPTIONS ELECTRICAL OPTIONS TERMINATION CONNECTORS FOR VALVES SOLENOID


SEE SEE WITH B OR BE TOP ELEC. CONN. BOX SEE
NOTE CODE DESCRIPTION NOTE CODE DESCRIPTION TOP E LE C. CONN. BOX W/5 PIN NOTE CODE VOLT FR DESCRIPTION
SINGLE SOL. OMIT DIN S TYLE S OLE NOIDS 8, 9, 14 5H MALE MINI R E CE PTACLE , DIN. 43650
OMIT CONNE CTOR ON "B" POR T E ND 33 120/110 60/50
"A" PORT END TOP E LE C. CONN. BOX WITH E LE C. CONN.
SINGLE SOL. OPERATOR TOP E LE C. CONN. BOX W/5 PIN
1 R 2 B TE R MINAL POS TS , LIGHTS AND DIN. 43650
8, 9, 14 5A MALE MINI R E CE PTACLE , 34 240/220 60/50
ON "B" PORT END S UR GE S UPPR E S S OR E LE C. CONN.
M RIVETT MTG. PATTERN CONNE CTOR ON "A" POR T E ND DIN. 43650
TOP ELEC. CONN. BOX WITH TOP E LE C. CONN. BOX W/4 PIN 37 24/24 60/50
MANUAL E LE C. CONN.
U 2 BE TERMINAL POSTS
OVERRIDE BOOT 5, 9, 14 4 MALE MICR O R E CE PTACLE ,
DIN. 43650 E LE C.
MNL OVRD FOR CONNECTOR ON "B" PORT END 39 120/110 60/50
1 Z CONN. LOW FOR CE
SGL SOL VALVE TOP ELEC. CONN. BOX W/4 PIN DIN. 43650
NON SOL END 5, 9,14 4A MALE MICRO RECEPTACLE, 42 24 VDC N/A
E LE C. CONN.
6 WD WASH DOWN CONNECTOR ON "A" PORT END
DIN. 43650
TOP ELEC. CONN. BOX W/4 PIN 44 12 VDC N/A
E LE C. CONN.
5, 9, 14 D4 MALE MICRO RECEPTACLE,
CONNECTOR ON "B" PORT END 2, 3 50 120/110 60/50 HAZARDOUS LOCATION
TOP ELEC. CONN. BOX W/4 PIN
5, 9, 14 D4A MALE MICRO RECEPTACLE, 2, 3 52 240/220 60/50 HAZARDOUS LOCATION
CONNE CTOR ON "A" POR T E ND
TOP E LE C. CONN. BOX W/3 PIN 2 60 120/110 60/50 2 PIN
1, 8, 14 3H MALE MINI R E CE PTACLE ,
CONNECTOR ON "B" PORT END 2 61 240/220 60/50 2 PIN
TOP ELEC. CONN. BOX W/3 PIN
1, 8, 14 3A MALE MINI RECEPTACLE, 2 65 24/24 60/50 2 PIN
CONNECTOR ON "A" PORT END
2 PIN
9, 14 T4 BOX w/ 4 PIN MALE DIN, 2 68 120/110 60/50
LOW AMP, LOW FOR CE
15 CONNECTOR ON "B" PORT END
9, 15 T4A BOX w/ 4 PIN MALE DIN, 2 70 24 VDC N/A 2 PIN
CONNECTOR ON "A" PORT END
HAZARDOUS DUTY, TOP ELEC. 2 75 12 VDC NA 2 PIN
3 HD CONN., BOX CLASS II, GROUPS
E, F & G
9, 12, SW N.O. SPOOL POSITION
13, 14 INDICATOR SWITCH

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 13


VS5M ANTI-SHOCK VALVES
SOLENOID ACTUATED, DIRECT OPERATED

TYPICAL PERFORMANCE
SPECIFICATIONS
Performance is measured on a four-way circuit (full
circuit). Performance may be reduced from that
shown if a three-way circuit (half circuit) is used,
i.e. A or B port plugged.

NOMINAL FLOW RATE


@ 3500 PSI 5 gpm 19 lpm

MAXIMUM FLOW RATE SEE CHART


CSA Certified
MAXIMUM P, A, B Ports 4600 psi 315 bar
OPERATING
T Port (includes surges) 1500 psi 105 bar
DESCRIPTION PRESSURE
As the valve spool shifts, the spool lands cross over
INTERNAL (1-port) 9 cipm 148 mlpm
the valve body ports. This can produce high LEAKAGE 3500 psi 100 SUS 23 cipm 380 mlpm
instantaneous flow rates. The anti-shock valve
provides a slow spool movement; slower than that of MAXIMUM
Option S1 60 cpm
a standard directional valve. This results in reduction CYCLE
Option S2 50 cpm
RATE*
or elimination of hydraulic system shock produced by
the spool movement and high flow rates. TIMING
Option S1 60 cpm
SPOOL
Option S2 50 cpm
SHIFT*
TYPICAL PRESSURE DROP CURVES
ANSI/B93.7-1986 - D08
bar psi MOUNTING SURFACE
ISO 4401 - SIZE 08
16 8 7 6
225
Single Actuator 31 LBS. 14 kg
WEIGHT
14 200 Double Actuator 32 lbs. 14.5 kg

12 175 SPOOL CODES AVAILABLE A, A2C, B2,F1, L


∅ P PRESSURE DROP

5
10 150 * Timingfor spool shift is dependent on fluid voscosity.
4
125 All pressure drops shown on this data page are
8
100 3 based on 100 SUS fluid viscosity and 0.87 specific
6 gravity. See the chart below for other viscosities.
75
2
4 1 Fluid CS 14.5 20.5 32 43 54 65 76 86
50
Viscosities SUS 75 100 150 200 250 300 350 400
2 25 Multiplier 0.93 1.00 1.11 1.19 1.26 1.32 1.37 1.41

For any other specific gravity (G1) the pressure drop


gpm 0 1 2 3 4 5 6 7 8
(∆P) will be approximaately ∆P1 = ∆P (G1/G).
lpm 0 10 20 30
FLOW

FLOW PATH ∆P CURVES

FLOW CURVE NUMBER


SPOOL SPOOL SHIFTED SPOOL CENTERED
TYPE P to A or B A or B to T A or B to T P to T
A 2 1 N/A N/A
A2C 6 6 N/A N/A
B2 2 1 N/A 7
F1 2 1 8 N/A
L 5 4 N/A 3

14 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VS5M ANTI-SHOCK VALVES
SOLENOID ACTUATED, DIRECT OPERATED

SPOOL DESCRIPTION

CODE SYMBOL SPOOL FUNCTION CENTER POSITION CROSSOVER


A
A1C All ports blocked All ports blocked
A2C

B1 All ports open, All ports open,
B2 restricted restricted
P blocked P blocked
F A & B restricted A or B restricted
to T to T
L P to T All ports open,
L3 A & B blocked restricted

MAXIMUM FLOW
SPOOL AND TIMING
S1 S2
FUNCTION A A2C B2 F1 L A L
CODE AC DC AC DC AC DC AC DC AC DC AC DC AC DC
(23) (23) (19) (23)
(lpm) (70 bar) 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
6 6 5 6
@
(27) (27) (15) (23) (23) (30) (23) (23) (23) (19)
gpm 1000 psi 3, 5 N/A N/A N/A N/A
7 7 4 6 6 8 6 6 6 5
(19) (23) (19) (23)
(lpm) (140 bar) 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
5 6 5 6
@
(23) (23) (15) (19) (19) (30) (19) (15) (23) (15)
gpm 2000 psi 3, 5 N/A N/A N/A N/A
6 6 4 5 5* 8 5 4 6 4
(15) (23) (19) (23)
(lpm) 210 bar) 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
4 6 5 6
@
(19) (19) (15) (15) (15) (30) (15) (12) (19) (12)
gpm 3000 psi 3, 5 N/A N/A N/A N/A
5 5 4 4 4* 8 4 3 5 3
N/A Valve is not available in this configuration.

* 95% of rated voltage required at pressure above 2000 psi.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 15


VS5M ANTI-SHOCK VALVES
SOLENOID ACTUATED, DIRECT OPERATED

TYPICAL ELECTRICAL CHARACTERISTICS

INRUSH
VOLTAGE & VOLTAGE CURRENT HOLDING HOLDING
SOLENOID CODE FREQUENCY LIMITS RESISTANCE (AMPS) CURRENT POWER
LEAD DIN
VOLTS - Hz. MIN. - MAX. OHMS MAX. (AMP) (WATTS)
WIRE CONN.
120 - 60 108 - 126 .40 21
60L 33L 36.5 2.10
110 - 50 99 - 116 .43 21
240 - 60 216 - 252 .21 22
61L 34L 145.0 1.10
220 - 50 198 - 231 .25 22
70L 42L 24 DC 21 - 26 24.0 1.00 1.00 24
75L 44L 12 DC 10 - 13 6.3 2.00 2.00 24

NFPA D03 SIZE DIMENSIONS SHOWN IN: (MILLIMETERS)


(Formerly D01) INCHES
FOR INTERFACE PATTERN,
SEE MOUNTING SURFACE
SECTION

TWO LEAD WIRES FOR EACH ACCESS TO MOUNTING BOLTS (4)


SOLENOID APPROX . (153 .0) LONG) TORQUE 4.5 lb.-ft. USE A
6 .0 5/32 HEX WRENCH
HAND TORQUE ONLY
FOR SOLENOID NUT

MIN . CLEARANCE (42 .2) (77 .7)


FOR COIL REMOVAL 1 .64 3 .06
AC SOL .

(195 .6)
7 .70 DOUBLE SOLENOID AC

1/2-14 NPT
ELECTRICAL
CONNECTION
25 ft . lbs . (1 .5) (138 .2) SINGLE
MAX. TORQUE .08 5 .44 SOLENOID AC
(48 .3) ELECTRICAL
1 .90 BOX MAY BE
(81 .0) ROTATED 180°
3 .19
Solenoid Solenoid
OVERRIDE PIN (62 .2) "b" "a" (16 .5)
(SOLENOID 2 .45 .65
ENDS ONLY)
b APB
(22 .9) T
.90
(45 .5) (23 .9)
1 .79 .94 (63 .8) (68 .1) (6 .4)
2 .51 2 .88 .25
ORIENTATION PIN
(3 .0) DIA . x (3 .0) LONG
.12 .12

16 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VS5M ANTI-SHOCK VALVES
SOLENOID ACTUATED, DIRECT OPERATED

CODES 33L, 34L, 42L & 44L DIMENSIONS SHOWN IN: (MILLIMETERS)
Solenoid with DIN 43650/ISO 4400 (form A) connector(s). INCHES

(180 .3) MAX . DOUBLE


7 .10 SOLENOID
(126 .7) SINGLE
(55 .9) 4 .99 MAX .SOLENOID
2 .21 MAX .
BLACK
PLUG GREY
(90 .7) PLUG
3 .57
(79 .5)
3 .13 MAX .

SOLENOID
SOLENOID “a”
“b”
NOTES:
1. No electrical box required
2. Order connectors separately.

CODE B5H
Quick disconnect for single or double solenoids.
PIN NO. WIRE NO. GOES TO: Top electrical box with sealed 5-pin male receptacle.
1 1 SOL. B
2 2 SOL. A
3 (GREEN) GROUND
4 4 SOL.A
5 5 SOL. B

1 5
2 4
3 NOTE:
Connector meets ANSI recommended standard
B93.55M-1981.

CODES L1 & L2
Solenoid indicator lights.

(91 .2)
3 .59

NOTE:
Top electrical box is required.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 17


VS5M ANTI-SHOCK VALVES
SOLENOID ACTUATED, DIRECT OPERATED

ORDERING INFORMATION
SELECT SELECT SELECT SELECT SELECT SELECT
ONE ONE ONE ONE ONE ONE

VS5M ­ G­

BASIC VALVE SPOOLS SEALS ELECTRICAL OPTIONS SOLENOID*


CODE CODE CODE DESCRIPTION CODE VOLTAGE
4-WAY
LEAD WIRE LEAD WIRE
DIRECTIONAL CONNECTIONS
CONNECTIONS
CONTROL REFER TO VITON 110/120 V
TOP 60L
VALVE SPOOL SEALS 50/60 Hz
ELECTRICAL
DESCRIPTION STANDARD B 220/240 V
BOX WITHOUT 61L
SOLENOID CHART 50/60 Hz
TERMINAL POSTS
ACTIVATED 70L 24 VDC
TOP
ELECTRICAL 75L 12 VDC
D03 SUBPLATE SOLENOID(S) WITH DIN
BT BOX WITH
MOUNTING 43650/ISO 4400 (FORM A)
TERMINALS AND
GROUND CONNECTIONS
4600 PSI 110/120 V
TOP 33L
MAXIMUM 50/60 Hz
ELECTRICAL
OPERATING TIMING* BOX WITH 220/240 V
PRESSURE 34L
B5H 5 PIN MALE 50/60 Hz
CODE OPTION
RECEPTACLE 42L 24 VDC
S1 50 - 150 MS
FOR 1 OR 2 44L 12 VDC
100 - 300 MS
S2** SOLENOIDS * Available on Codes 3 and 5
(DC Only)
with DC solenoids only.
FUNCTION * Timing is dependent on
fluid viscosity.
CODE OPTION ** Available on Codes 3 and
5 with DC solenoids only.

1
MECHANICAL OPTIONS
Single actuator • 2 position CODE DESCRIPTION
Spring offset OMIT NONE
SINGLE
SOLENOID
3 R REVERSE
ASSEMBLY
Double actuator • 3 position SOLENOID “A”
Spring centered SUPPLIED

Single actuator • 2 position


Spring centered

TYPICAL ORDERING CODE: VS5M-1A-GS1B-60L

18 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


ELECTRICAL ACCESSORIES

MALE RECEPTACLES

Three Pin Connector, Codes B3A, B3H Five Pin Connector, Codes B5A, B5H Four Pin Micro-Connector, Codes B4, B4A
Use with single solenoid valve Use with single or double solenoid valve Use with single or double solenoid valve
Available with 2-pin DC coils only
1 - Green (Ground) Lead 1 - Lead to Solenoid B
1 - Lead to
2 - Lead to Solenoid 2 - Lead to Solenoid A Solenoid B (Brown)
2 - No Connection (White)
3 - Lead to Solenoid 5 - Lead to Solenoid B
3 - Common Lead to 4 - Lead to
4 - Lead to Solenoid A Solenoid A (Black)
Solenoids A & B (Blue)
1 2 1
1 5 3 4
4
2 3 2 3 M12 x 1 Thread

.875 (22,3)

VEA-3C (5 PIN)
Across Flats
3 - Green (Ground) Lead
1 .0 (25,4) 1 .0 (25,4)
Hex Hex

Three Pin Connector, Codes B3A, B3H Five Pin Connector, Codes B5A, B5H
Use with single solenoid valve Use with single or double solenoid valve
1 - Green (Ground) Lead 1 - Lead to Solenoid B
2 - Lead to Solenoid 2 - Lead to Solenoid A
2 - No Connection
3 - Lead to Solenoid 5 - Lead to Solenoid B
4 - Lead to Solenoid A 3 - Common
Solenoids A &
1 5
1
4
2 3 2 3

VEA-3MH (3 PIN) 1 .0 (25,4)


Hex
1 .0 (25,4)
Hex
3 - Green (Ground) Lead

Three Pin Connector, Codes B3A, B3H Five Pin Connector, Codes B5A, B5H Four Pin Micro-Connector, Codes B4, B4A
Use with single solenoid valve Use with single or double solenoid valve Use with single or double solenoid valve
Available with 2-pin DC coils only
1 - Green (Ground) Lead 1 - Lead to Solenoid B
1 - Lead to
2 - Lead to Solenoid 2 - Lead to Solenoid A Solenoid B (Brown)
2 - No Connection (White)
3 - Lead to Solenoid 5 - Lead to Solenoid B
3 - Common Lead to 4 - Lead to
4 - Lead to Solenoid A Solenoid A (Black)
Solenoids A & B (Blue)
1 2 1
1 5 3 4
4
2 3 2 3 M12 x 1 Thread

.875 (22,3)
Across Flats

VEA-3L41 .0(M12
3 - Green (Ground) Lead
1 .0 (25,4)
Hex
(25,4)
Hex 4 PIN)

VEA-3T4 (DIN 3 + GND)

FEMALE RECEPTACLES

VEA-3L (M12 4 PIN)


VEA-3D (5 PIN) (9 ft. cord)
(9 ft. cord)

VEA-3M (3 PIN) VEA-3E / VEA-3F


(9 ft. cord) (gray) (black)

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 19


VMD03M
LEVER ACTUATED, MANUALLY OPERATED

TYPICAL PERFORMANCE
SPECIFICATIONS
Performance is measured on a four-way circuit (full
circuit. Performance may be reduced from that
shown if a three-way circuit (half circuit) is used, i.e. A
or B port plugged.

FLOW CAPACITY - (up to) 18 gpm 68 lpm



MAXIMUM P, A, B Ports 5000 psi 345 bar
OPERATING
T Port 1000 psi 70 bar
PRESSURE

LEVER FORCE AT
10.0 lbs. 4.5 kg
MAXIMUM PRESSURE

MOUNTING ANSI/B93.7M - 1986 D03


SURFACE ISO 4401 Size 03

WEIGHT 3.4 lbs. 1.5 kg
MAXIMUM RECOMMENDED FLOW
SPOOL CODES AVAILABLE SEE CHART

SPOOL CODE
SPOOL DESCRIPTION
FUNCTION
CODE
A B F G* L**

(68) (42) SPOOL
N/A N/A N/A
18 11 TYPE SPOOL SYMBOL
(lpm) (70 bar)
@ 2 (68) (61) (61) (38)
N/A
gpm 1000 psi 18 16 16 10
(68) (61) (61) (68) (38) A PULL PUSH
3, 5
18 16 16 18 10
1 (68) (38)
N/A N/A N/A
18 10
(lpm) (140 bar) B PULL PUSH
@ 2 (68) (61) (61) (38)
N/A
gpm 2000 psi 18 16 16 10
3, 5 (68) (61) (61) (68) (38)

18 16† 16 18 10
(68) (34) F PULL PUSH
1 N/A N/A N/A
18 9
(lpm) (210 bar)
@ 2 (68) (61) (61) (38)
N/A
gpm 3000 psi 18 16 16 10
(68) (61) (53) (61) (34) F1 PULL PUSH
3, 5
18 16† 14† 16 9
1 (68) (26)
N/A N/A N/A
18 7
(lpm) (276 bar) G PULL PUSH
@ 2 (68) (61) (61) (34)
N/A
gpm 4000 psi 18 16 16 9
3, 5 (68) (61) (45) (53) (26)

18 16† 12† 14† 7
(68) (26) L PULL PUSH
1 N/A N/A N/A
18 7
(lpm) (345 bar)
@ 2 (68) (61) (61) (15)
N/A
gpm 5000 psi 18 16 16 4
3, 5 (68) (53) (45) (45) (34)

18 14† 12† 12† 9
N/A Not Available.
* “G” spool available on code 3 valves only.
** “L” spool available on codes 3 and 4 valves only.
† 11 gpm with 1000 psi tank pressure.

20 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VMD03M
LEVER ACTUATED, MANUALLY OPERATED

TYPICAL PRESSURE DROP CURVES


11 10 9 7 6 5 4 3 2
160
1
8
140

120
PRESSURE DROP (psid)

100

80

60

40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
FLOW (gpm)

PRESSURE DROP CURVE CHART

FLOW CURVE NUMBER


SPOOL SPOOL SHIFTED SPOOL CENTERED
TYPE P to A B to T P to B A to T P to A or B A or B to T P to T
A 4 4 4 4 N/A N/A N/A
B 2 4 2 4 5 6 5
F 5 1 5 1 N/A 10 N/A
F1 5 4 5 4 N/A 11 N/A
G 3 6 3 6 7 N/A N/A
L 8 8 8 8 N/A N/A 9
Subplate S (Full Circuit)

All pressure drops shown on this page are based on


100 SUS fluid viscosity, and 0.87 specific gravity.
See the chart below for other viscosities.

Fluid CS 14.5 20.5 32 43 54 65 76 86


Viscosities SUS 75 100 150 200 250 300 350 400
Multiplier 0.93 1.00 1.11 1.19 1.26 1.32 1.37 1.41

For any other specific gravity (G1) the pressure drop


(∆P) will be approximately ∆P1 = ∆P (G1/G).

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 21


VMD03M
LEVER ACTUATED, MANUALLY OPERATED

DIMENSIONS

2.00 NORMAL POSITION


1.00 VMD03M-1 CODE R

8° 8°
REMOVAL
SPOOL CENTERED
"P" OPEN TO "A"
"P" OPEN TO "B"

5.86

BORE

1.03

.75
.93 .13
.91
2.482 .58
1.86 2.442
1.82
2.310 6.04
CLEARANCE
REQUIRED FOR
OPERATOR REMOVAL

22 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VMD03M
LEVER ACTUATED, MANUALLY OPERATED

ORDERING INFORMATION

SELECT SELECT SELECT DESIGN


ONE ONE ONE LETTER

VMD03M ­ G­ 10­ A­

SPOOLS SEALS OPERATOR


CODE CODE TYPE
CODE
REFER TO VITON
SPOOL SEALS
DESCRIPTION STANDARD LEVER
CHART

FUNCTION MECHANICAL OPTIONS


CODE OPTION CODE DESCRIPTION
SINGLE
OMIT SOLENOID
“A” PORT END
1
SINGLE
2 position R SOLENOID
spring offset “B” PORT END
LEVER
OPERATOR
90 ROTATED 90
2
DEG. TOWARDS
2 position “T” PORT
detented, no spring LEVER
OPERATOR
90CW ROTATED 90
DEG. TOWARDS
3
“P” PORT
3 position
spring centered


4
3 position
detented, spring centered

TYPICAL ORDERING CODE: VMD03M-3A-G-10-A

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 23


VAD03M
AIR ACTUATED, DIRECT OPERATED

SPOOL DESCRIPTION

SPOOL
TYPE SPOOL SYMBOL

A b Port a Port

A
Code b Port a Port
1 and 2
TYPICAL PERFORMANCE
SPECIFICATIONS
B b Port a Port
MAXIMUM FLOW RATE - (up to) 15 gpm 57 lpm

MAXIMUM P, A, B Ports 5000 psi 345 bar B
OPERATING
PRESSURE
T Port 300 psi 21 bar Code b Port a Port
1 and 2
PILOT Recommended Max. 150 psi 10.5 bar
PRESSURE Minimum 50 psi 3.5 bar
F b Port a Port
 ACTUATOR Offset to Offset 0.15 cu.in. 2.5 ml
DISPLACEMENT Center to Offset 0.08 cu. in. 1.25 ml

MAXIMUM CYCLE RATE 300 cpm G b Port a Port

MOUNTING ANSI/B93.7M - 1986 D03


SURFACE IISO 4401 Size 03
L a Port b Port
Single Actuator 3.0 lbs. 1.35 kg
WEIGHT
Double Actuator 3.4 lbs. 1.56 kg

SPOOL CODES AVAILABLE A, B F, G, L MAXIMUM FLOW*
SPOOL CODE
FUNCTION
CODE A B F G L
(49) (34)
1 N/A N/A N/A
13 9
(lpm) (105 bar)
(57) (57)
@ 2 N/A N/A N/A
15 15
gpm 1500 psi
(57) (57) (57) (49) (34)
3, 5
15 15 15 13 9
(34) (34)
1 N/A N/A N/A
13 9
(lpm) (210 bar)
(57) (57)
@ 2 N/A N/A N/A
15 15
gpm 3000 psi
(57) (57) (38) (49) (34)
3, 5
15 15 10 13 9
(49) (34)
1 N/A N/A N/A
13 9
(lpm) (345 bar)
(57) (57)
@ 2 N/A N/A N/A
15 15
gpm 5000 psi
(45) (45) (19) (49) (38)
3, 5
12 12 5 13 9
N/A Not Available.
* Performance measured on a four-way circuit with cylinder ports looped together
with 50 psi pilot presure, measured @ 100 SUS oil viscosity.

24 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VAD03M
AIR ACTUATED, DIRECT OPERATED

TYPICAL PRESSURE DROP CURVES


10 9 7 6 5 4 3 2
160

1
8

120
PRESSURE DROP (psid)

S
80

40

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
FLOW (gpm)

FLOW PATH ∆P CURVES

FLOW CURVE NUMBER


SPOOL SPOOL SHIFTED SPOOL CENTERED
TYPE P to A B to T P to B A to T P to A or B A or B to T P to T
A 4 4 4 4 N/A N/A N/A
A
Code 4 4 4 4 N/A N/A N/A
1 & 2
B 2 4 2 4 5 6 5
B
Code 3 2 3 2 5 6 5
1 & 2
F 5 1 5 1 N/A 10 N/A
G 3 6 3 6 7 N/A N/A
L 8 8 8 8 N/A N/A 9
Subplate S (Full Circuit)

Performance is measured on a four-way circuit (full circuit). Performance may


be reduced from that shown if a three-way circuit (half circuit) is used, i.e. A or B
port plugged.
All pressure drops shown on this data page are based on 100 SUS fluid viscosity
and 0.87 specific gravity. See the chart below for other viscosities.
Fluid CS 14.5 20.5 32 43 54 65 76 86
Viscosities SUS 75 100 150 200 250 300 350 400
Multiplier 0.93 1.00 1.11 1.19 1.26 1.32 1.37 1.41

For any other specific gravity (G1) the pressure drop (∆ P) will be approximately
∆P1 = ∆P (G1/G).

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 25


VAD03M
AIR ACTUATED, DIRECT OPERATED

DIMENSIONS: MODELS VAD03M-1 & VADO3M-5

1 .44
1 .84
.92

WRENCH ACCESS TO MOUNTING


THRU TOP OF VALVE ASSEMBLY
4 HOLES TYPICAL

5 .36
.26 2 .10 3 .001 .312
2 .999
.030
.20
.495 T
2 .06 .61
1 .02 1 .250
1 .220
B A
1 .03
P
.50
2 .75 .85
.13 .12
1 .19
1 .300
1 .594
2 .244

DIMENSIONS: MODELS VAD03M-2 & VAD03M-3

1 .44
1/8”
NPT 1 .84
.92

WRENCH ACCESS TO MOUNTING


THRU TOP OF VALVE ASSEMBLY
4 HOLES TYPICAL
7 .20
5 .10
2 .10

2 .06

1 .03

.13 2 .75

26 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VAD03M
AIR ACTUATED, DIRECT OPERATED

ORDERING INFORMATION

SELECT SELECT SELECT DESIGN


ONE ONE IF REQ’D LETTER

VAD03M ­ G­ 10 ­ A­

BASIC VALVE FUNCTION SPOOLS OPERATOR


CODE OPTION CODE CODE DESCRIPTION
4-WAY 10 PISTON
DIRECTIONAL b
A B
REFER TO
CONTROL 1 SPOOL
VALVE P T DESCRIPTION
Single operator • 2 position CHART
AIR Spring offset
ACTIVATED MECHANICAL OPTIONS
A B a
b
D03 SUBPLATE CODE DESCRIPTION
2 SEALS
MOUNTING P T
SINGLE
CODE R OPERATOR
Double operator • 2 position
4600 PSI “B” PORT END
Detented (No spring)
MAXIMUM VITON
b A B a
OPERATING SEALS
PRESSURE 3* STANDARD
P T

Double operator • 3 position


Spring centered
b A B

5*
P T

Single operator • 2 position


Spring centered
* Operator identification reversed with “L” spool.

TYPICAL ORDERING CODE: VAD03M-1A-G-10

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 27


VCD03M
CAM ACTUATED, DIRECT OPERATED

Physical Specifications

Weight (No modifications):


VCD03M-1 Single Operators
3.2 lbs. (1.45 kg)

Size: conforms to American National


Standard, ANSI B93.7M, D03 Size
Mounting Interface (ISO 4401 size 03 /
CETOP 3 / NG 6)

VSD03M-1 Single Operator, Operating Specifications


2 position, spring offset
Flow capacity: Maximum flows up to
12 GPM (46 lpm)
Maximum operating pressure:
P, A and B ports -5000 PSI
(345 bar)
Maximum tank line back pressure:
600 PSI (42 bar) including transient
Recommended fluid : Any hydraulic fluid
compatible with selected seal
materials
Basic Valve Operation Fluid temperature range
This valve incorporates a cam operator on Fluid temperatures up to 200°F
one end of the spool and an offset spring (93°C) will not appreciably affect
on the opposite end of the spool. With the valve performance, however, from a
spool in the normal position, the spring- safety standpoint, temperatures
loaded spool is held in position at the above 130°F. (54°C) are not
operator’s side of the body by the offset recommended.
spring providing a specific flow pattern. Recommended fluid:
Actuating the push rod causes the spool to Operating viscosity ranges 80 to
shift against the spring, to a position at the 350 SUS at operating temperature.
opposite side of the valve body providing Filtration recommendations:
a flow pattern opposite that obtained in the ISO CODE 18/16/13
first (normal) position. The spool will remain Cycle rate:
in this position until the load is released from Up to 1000 cycle/minute
the push rod, allowing the spring to shift Mounting: unrestricted
the spool back to its normal offset position. Recommended mounting bolt torque:
There is no center position dwell in this 4-5 lbs.-ft.
valve. .55 to .70 kg-m)
Duty cycle: Continuous

28 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VCD03M
CAM ACTUATED, DIRECT OPERATED

PRESSURE DROP CURVE CHARTS

FLOW CURVE NUMBERS

Spool Spool Shifted


Code P to A or B A or B to T
A 3 2
G 1 3

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 29


VCD03M
CAM ACTUATED, DIRECT OPERATED

DIMENSIONS:

30 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VCD03M
CAM ACTUATED, DIRECT OPERATED

ORDERING INFORMATION

SELECT DESIGN
ONE LETTER

VCD03M ­ 1 ­ G­ 13 ­ A­

BASIC VALVE FUNCTION OPERATOR


CODE OPTION CODE DESCRIPTION
4-WAY 13 CAM TYPE
DIRECTIONAL
CONTROL
1
VALVE
CAM operated • 2 position
AIR Spring offset
ACTIVATED

D03 SUBPLATE
MOUNTING SPOOL SEALS
CODE SYMBOL CODE
4600 PSI
MAXIMUM VITON
OPERATING A SEALS
PRESSURE STANDARD

TYPICAL ORDERING CODE: VCD03M-1A-G-13-A

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 31


VSD03M SPECIAL APPLICATION PRODUCTS
HAZARDOUS DUTY, SOLENOID ACTUATED, DIRECT OR PILOT OPERATED

VALVE FEATURES

• Ground terminal located in wiring cavity.

• Electrical certification in accordance with


CSA STD. C22.2 No. 25-1966 for use in
Class II; groups E, F, & G hazardous locations.

• May be used in locations as defined in the National


Electrical Code Class II; Div. 1 & 2; Groups E, F, &
G. Designed in accordance with ANSI/NEMA
ICS6110.26 Type 9 standards. (Combustible dust
environments, i.e. metallic, coal, grain).

NFPA SIZE D03 • CSA Certified (Canadian Std.Assn.).

• Same performance curves and specifications as


standard valves unless noted below.

TYPICAL ELECTRICAL & RESPONSE TIME


SOLENOID CODE* INRUSH
50L VOLTAGE & VOLTAGE CURRENT HOLDING HOLDING RESPONSE TIME
(110/120V FREQUENCY LIMITS (AMPS) CURRENT POWER (MILLISECONDS)
50/60 Hz)
VOLTS - Hz. MIN. - MAX. MAX. (AMP) (WATTS) SOLENOID SPRING


120 - 60 108 - 126 .56 28 12 15
VSD03M 2.50
110 - 50 99 - 116 .69 31 14 15
* Consult factory on other voltages:

32 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M SPECIAL APPLICATION PRODUCTS
HAZARDOUS DUTY, SOLENOID ACTUATED, DIRECT OR PILOT OPERATED

SPOOL DESCRIPTION

CODE SYMBOL SPOOL FUNCTION CENTER POSITION CROSSOVER



A All ports blocked All ports blocked

A2 All ports blocked All ports blocked




B All ports open All ports open


P & A blocked
E All ports blocked
B to T


P blocked P blocked
F
A & B to T A or B to T
P blocked P blocked
F1 A & B restricted A or B restricted
to T to T
P to A or B P to A or B
G* T & A or B T & A or B
blocked blocked

P to A & T
H All ports open
B blocked


P to B
J All ports blocked
A & T blocked


P to B blocked
K All ports blocked
A to T


P to T All ports open,
L
A & B blocked restricted


P to A
N All ports blocked
B & T blocked

A B
P to B & T
Q All ports open
A blocked

P T
* VSD03M G spool available for quantity orders only. Consult factory for price and delivery.

NOTES: Code G or L available on Codes 3 and 5 valves only.


Code F1 available on Codes 1, 3 and 5 valves only.
Code B not available on Code 1 with D.C. solenoids.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 33


VSD03M SPECIAL APPLICATION PRODUCTS
HAZARDOUS DUTY, SOLENOID ACTUATED, DIRECT OR PILOT OPERATED

VSD03M VALVES DIMENSIONS SHOWN IN: (MILLIMETERS)


AC SOLENOIDS (SINGLE & DOUBLE) INCHES
NFPA D03 SIZE
SEE MOUNTING
SURFACES SECTION FOR
INTERFACE PATTERN

34 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M SPECIAL APPLICATION PRODUCTS
SOLENOID ACTUATED, DIRECT OR PILOT OPERATED

ORDERING INFORMATION
SELECT SELECT SELECT SELECT
ONE ONE ONE ONE

VSD03M­ G­ HD ­

FUNCTION SPOOLS MECHANICAL OPTIONS SOLENOID


CODE OPTION AVAILABLE CODE OPTION CODE VOLTS
A B CODES OMIT NONE
b
SINGLE SOLENOID
50L
120/110
1
P T A
R
REVERSE ASS’Y. VAC
B SOLENOID “A”
Single actuator • 2 position F SUPPLIED
Spring offset 240/220
52L
A B VAC
a b
A
2 B
P T
F
Double actuator • 3 position
No spring, detented

b A B a

3 ALL
P T SPOOLS
Double actuator • 3 position
Spring centered
A B b
ALL
5 Spool Center SPOOLS
P T Position

Single actuator • 2 position


Spring centered

b A B
A G
B L
6 P T F
Single actuator • 2 position
Spring offset,
energize to center

ORDERING INFORMATION: VSD03M-2A-GHD-50L

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 35


VSD03M SPECIAL APPLICATION PRODUCTS
HAZARDOUS DUTY, SOLENOID ACTUATED, DIRECT OR PILOT OPERATED

NFPA SIZE D03 TYPICAL PERFORMANCE


SPECIFICATIONS
Performance is measured on a four-way circuit (full
circuit). Performance may be reduced from that
shown if a three-way circuit (half-circuit) is used, i.e.
A or B port plugged.

FLOW RATE - (up to) 20 gpm 76 lpm

MAXIMUM P, A, B Ports 5000 psi 345 bar


OPERATING
T Port (Includes surges) 1000 psi 69 bar
PRESSURE

MAXIMUM AC Solenoids 400 cpm


CYCLE RATE DC Solenoids 300 cpm

  NFPA/T3.5.1M R1-1984
MOUNTING (D03) (Formerly D01)
SURFACE ANSI/B93.7M - 1986 - D03
ISO 4401 - SIZE 05
TYPICAL PRESSURE DROP CURVES
Single Actuator 8.3 lbs. 3.76 kg
WEIGHT
1 2 3 4 5 6 Double Actuator 14.1 lbs. 6.40 kg
160
7 SPOOL CODES AVAILABLE SEE CHART

P
120 LISK SOLENOIDS ARE:
r
e Class I Groups C & D
s
s
u S Class II Groups E,F & G
r
e 80 (Both Division I & 2)
D
r Temperature Code No. T3C
o
p • CSA Certified LR 49650-1
(psid)
• UL Listed; File No. E71190 (N)
40
• Recognized by U.S. Coast Guard
• Registered by Lloyd”s Register of Shipping
0
0 2 4 6 8 10
Flow (gpm)
12 14 16 18 20
All pressure drops shown on this data page are
based on 100 SUS fluid viscosity and 0.87 specific
gravity. See the chart below for other viscosities.

Fluid CS 14.5 20.5 32 43 54 65 76 86


Viscosities SUS 75 100 150 200 250 300 350 400
Multiplier 0.93 1.00 1.11 1.19 1.26 1.32 1.37 1.41

For any other specific gravity (G1) the pressure


drop (∆P) will be approximately ∆P1 = ∆P (G1/G).

36 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M SPECIAL APPLICATION PRODUCTS
WITH EXPLOSION-PROOF SOLENOIDS

FLOW PATH ∆P CURVES

FLOW CURVE NUMBER


SPOOL SPOOL SHIFTED SPOOL CENTERED
TYPE P to A or B A or B to T P to A or B A or B to T P to T
A 5 4 N/A N/A N/A
A
Code 2 2 N/A N/A N/A
1 & 2
B 1 4 1 3 3
B
Code 2 1 3 3 4
1 & 2
F 5 1 N/A 6 N/A
L 3 5 N/A N/A 7

SPOOL DESCRIPTION

CODE SYMBOL SPOOL FUNCTION CENTER POSITION CROSSOVER



A All ports blocked All ports blocked


B All ports open All ports open


P blocked P blocked
F
A & B to T A or B to T

P to T All ports open,
L
A & B blocked restricted

NOTE: Consult the factory for other spool configurations.

TYPICAL ELECTRICAL & RESPONSE TIME


HOLDING HOLDING HOLDING
RATED MAXIMUM CURRENT CURRENT & POWER &
VOLTAGE & ACCEPTABLE INRUSH & RATED MINIMUM RATED
SOLENOID FREQUENCY VOLTAGE CURRENT VOLTAGE ACCEPTABLE VOLTAGE
CODE NO. (VOLTS - Hz.) (MIN. - MAX.) (AMP) (AMP) VOLTAGE (WATTS)
80L 120 - 60 108 - 126 2.2 .58 .38 27
87L 24 DC 21 - 26 1.37 1.37 1.20 33
88L 12 DC 10 - 13 2.75 2.75 2.29 33

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 37


VSD03M SPECIAL APPLICATION PRODUCTS
WITH EXPLOSION-PROOF SOLENOIDS

MAXIMUM FLOW**

SPOOL CODE
FUNCTION A B F* L
CODE AC DC AC DC AC DC AC DC
(49) (49) (60) (45)
1 N/A N/A N/A ­N/A
13 13 16 12
(lpm) (70 bar)
(57) (49) (64) (49)
@ 2 N/A N/A N/A ­N/A
15 13 17 13
gpm 1000 psi
(76) (68) (49) (38) (49) (45)
3, 5 N/A ­N/A
20 18 13 10 13 12
(42) (42) (53) (34)
1 N/A N/A N/A ­N/A
11 11 14 9
(lpm) (140 bar)
(53) (45) (64) (49)
@ 2 N/A N/A N/A ­N/A
14 12 17 13
gpm 2000 psi
(76) (68) (49) (38) (49) (38)
3, 5 N/A ­N/A
20 18 13 10 13 10
(42) (42) (49) (19)
1 N/A N/A N/A ­N/A
11 11 13 5
(lpm) (210 bar)
(49) (45) (64) (34)
@ 2 N/A N/A N/A ­N/A
13 12 17 9
gpm 3000 psi
(76) (64) (45) (38) (45) (23)
3, 5 N/A ­N/A
20 17 12 10 12 6
(42) (42) (49) (11)
1 N/A N/A N/A ­N/A
11 11 13 3
(lpm) (276 bar)
(49) (42) (60) (23)
@ 2 N/A N/A N/A ­N/A
13 11 16 6
gpm 4000 psi
(68) (64) (42) (26) (15)
3, 5 N/A N/A ­N/A
18 17 11 7 4
(42) (42) (45) (11)
1 N/A N/A N/A ­N/A
11 11 12 3
(lpm) (345 bar)
(49) (38) (60) (15)
@ 2 N/A N/A N/A ­N/A
13 10 16 4
gpm 5000 psi
(68) (57) (38) (11)
3, 5 N/A N/A N/A ­N/A
18 15 10 3
N/A Not Available. * “F” spool pilot valve may be used up to 5000 psi.

** Performance measured on a four-way circuit (full circuit) with cylinder ports looped together @ 90%
voltage for AC & DC solenoids measured @ 100 SUS oil viscosity & warm solenoids. Performance
may be reduced from that shown with one flow direction as in the case when “A” or “B” port is plugged
(half circuit).

38 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VSD03M SPECIAL APPLICATION PRODUCTS
WITH EXPLOSION-PROOF SOLENOIDS

DIMENSIONS DIMENSIONS SHOWN IN: (MILLIMETERS)


INCHES

(94 .0)
(64 .5) 3 .70
P
2 .54 A B
T
(18 .5)
.73 (42 .4)
1 .67

(6 .35) (68 .1)


.25 2 .68
(188 .7)
7 .43

(151 .6)
5 .97

(73 .2)
2 .88
W ATTAG E
(45 .0)
1 .77
DIRECTIONAL VALV
ALVE

M AX. OPER.PRESS

(72 .4)
2 .85
(40 .6) (53 .6)
1 .60 2 .11

(1 .14)
.045

P
A B
T

(35 .05)
1 .38

#10-24 THREAD (17 .5)


4 PLACES .69
4-5 FT/LBS
(113 .0) TORQUE (70 .4) (113 .0)
4 .45 2 .77 4 .45
(296 .42)
11 .67

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 39


VSD03M SPECIAL APPLICATION PRODUCTS
WITH EXPLOSION-PROOF SOLENOIDS

ORDERING INFORMATION

SELECT SELECT SELECT SELECT SELECT DESIGN


ONE ONE IF REQ’D ONE ONE LETTER

VSD03M* ­ G­ EX ­ A­

FUNCTION SPOOLS SEALS SOLENOID MFG.


CODE OPTION CODE CODE CODE DESCRIPTION
A B L LISK
b
REFER TO VITON
1 SPOOL SEALS
P T
DESCRIPTION STANDARD
Single operator • 2 position CHART
Spring offset
A B
b a

2
P T

Double operator • 2 position


Detented (No spring)

b A B a MECHANICAL OPTIONS EXPLOSION-PROOF SOLENOID


3 OPTIONS CODE VOLTAGE
CODE DESCRIPTION
P T
SINGLE CODE DESCRIPTION WITH 24” LEAD WIRES
Double operator • 3 position R SOLENOID EXPLOSION 80 120VAC - 60 Hz
Spring centered “B” PORT END EX PROOF 87 24 VDC
A B SOLENOIDS 88 12 VDC
b

5
P T

Single operator • 2 position


Spring centered

* PLEASE NOTE:
The complete VSD03M valve assembly is not CSA or UL certified.
However, the Lisk solenoid valves are certified. Rise block
included.

TYPICAL ORDERING CODE: VSD03M-3A-GEX-80L-A

40 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


DOUBLE REDUNDANT
DUAL KIT MOUNTING

Helping You Design Greater


Safety Into Your Product
Many new regulations require double redundant
monitoring in virtually all hydraulic systems. Only
Continental Hydraulics offers an off-the-shelf double
redundant directional control valve assembly that can
help you meet the new regulations.
Double directional control valve redundancy means
that if one critical valve fails, or your control circuit (i.e.
light curtain) tells one of the valves to shut off, the
machine or down-stream system will be disconnected
from the pressure source. Any stored hydraulic pressure
will routed back to the tank. Your system monitoring
equipment will alert you to the failure, so the system can
be shut down gracefully, avoiding damage and injury.
These double redundant monitoring valve assemblies
are equipped with two main spool position monitoring
switches, and two pressure tap ports. This allows
your control circuit to monitor the spool position, and
whether pressure is rising or falling. This information
can be used by the controls to help meet some
of the new regulations, and help you design a better
machine.
Continental Hydraulics Double Redundant Valve
Assemblies are ideal for applications such as:
• Brick and Block Manufacturing • Saw Mills
• Automotive Assembly Lines • Pouring Molten Steel
• Machining Centers • Fish and Poultry Processing Plants
• Crushing Boxes • Powering Dam Gates
• Compacting Refuse • Motion Simulators
• Missile Test Stations • Controlling Entertainment Rides
• Recharging Systems in Critical Petro- ­ ontinental Hydraulics Double Redundant Directional
C
Chemical/Energy Producing Applications Control Valve Assemblies are available in D03 and D05
• Pulp and Paper Product Production sizes, with flow rates from 1 to 20 GPM­.
• Manufacturing Automobiles
• Positioning Precision Machine Tools

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 41


DOUBLE REDUNDANT
SOLENOID ACTUATED, DIRECT OPERATED

CONNECTIONS

OUT T

B4
S2 DC ONLY

S1

B5A

IN T

KIT DUAL MONITORING D03

* ALLOW CLEARANCE ON EACH


SIDE FOR COIL REMOVAL.
1.70 AC COIL
2.31 DC COIL
8.17 AC COILS
9.38 DC COILS

SAE -12 TUBE PORT 6.79


SAE -04 TUBE PORT
1 1/16-12 UNF 7/16-20 UNF
4 PLACES 2 PLACES
.31
5/16-18 UNC .50 2.94
4 PLACES 2.19
1.25

2.38 .31
1.50

.75 3.65
2.51 AC COILS 2.66 AC COILS
3.11 DC COILS 3.00 3.26 DC COILS 5.17

ORDERING INFORMATION
SELECT SELECT
ONE ONE

Kit Dual Monitoring D 0 3 - - -M 1 2 3 3

Electrical Connection Solenoid


Code Description Code Voltage Description
5 pin Connector 60L 120/110 AC 2 pin Coil
Omit AC or DC Coils
4 pin Connector 70L 24 VDC 2 pin Coil
B4 DC Voltage Only

42 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


NFPA MOUNTING SURFACES

DIMENSIONS: Mounting surfaces must be flat within 0.1 mm per NOTES: A = Cylinder Port B = Cylinder Port T = Tank Port
100 mm (.0004 in. per 4.0 in.) and N8 63AA finish. P = Pressure Port X = Pilot Port Y = Drain Port

D03 MOUNTING SURFACE DIMENSIONS SHOWN IN: (MILLIMETERS)


Conforms to ANSI/B93.7-M-1986, ISO 4401 SIZE 03 INCHES

DIMENSIONS M Min .
L

mm INCH mm INCH mm INCH K

A 43.0 1.70 G .075 0.03 N 33.0 1.30 J


B 31.8 1.2 H 12.7 0.50 O 6.3 0.25 H
C 31.0 1.22 J 21.5 0.85 P 10-24UNC-2B F G
D 25.9 1.02 K 30.2 1.19 Q 4.0 .16
E 15.5 0.61 L 40.5 1.594 R 4.0 .16 T
F 5.1 0.20 M 51.0 2.00 E
C D
B
A A B
MIN .
P

N Q DIA . x R DP
P(4) THD . O DIA .
(4) MAX .

D05 MOUNTING SURFACE


Conforms to ANSI/B93.7-M-1986, ISO 4401 SIZE 05

DIMENSIONS A Min .
B
mm INCH mm INCH mm INCH C
D
A 72.1 2.84 F 3.2 0.13 L 32.5 1.28
J H E
B 54.0 2.13 G 9.1 0.36 M 46.0 1.81 F
C 37.3 1.47 H 11.2 0.44 N 57.9 2.28 G
D 27.0 1.06 J 6.4 0.25 O 11.2 0.44 P(4) THD .
E 16.7 0.66 K 21.4 0.844 P 1/4-20 UNC P

K
N L B
MIN .
M A
O(4) DIA .
T MAX .

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES 43


NFPA MOUNTING SURFACES

DIMENSIONS: Mounting surfaces must be flat within 0.1 mm per NOTES: A = Cylinder Port B = Cylinder Port T = Tank Port
100 mm (.0004 in. per 4.0 in.) and N8 63AA finish. P = Pressure Port X = Pilot Port Y = Drain Port

D08 MOUNTING SURFACE DIMENSIONS SHOWN IN: (MILLIMETERS)


Conforms to ANSI/B93.7-M-1986, ISO 4401 SIZE 08 INCHES

DIMENSIONS A MIN .
B
C
D
mm INCH mm INCH mm INCH E
A 154.0 6.00 J 11.1 0.44 R 116.0 4.57 F
B 130.2 5.13 K 17.5 0.69 S 1/2-13 UNC G
H
C 112.7 4.44 L 4.8 0.19 T 11.2 0.44
J
D 100.8 3.97 M 17.5 0.69 U 7.5 .28 K
M L
E 94.5 3.719 N 19.0 0.75 V 9.7 0.38
F 77.0 3.03 O 73.0 2.8 W 23.4 0.92
G 53.2 2.09 P 74.6 2.93
H 29.4 1.16 Q 92.1 3.63 P O T P Y
Q
R N
X A B
MIN .

S(6) THD . W(4) DIA. MAX.


T(2) DIA . MAX . U DIA. x V DP.(2)

D10 MOUNTING SURFACE


Conforms to ANSI/B93.7-M-1986, ISO 4401 SIZE 10

A MIN .
B
DIMENSIONS C
D
E
mm INCH mm INCH mm INCH F
A 230.1 9.06 H 41.3 1.63 P 158.8 6.25 J G R DIA . x S DP .(2)
B 190.5 7.50 J 19.0 0.75 Q 198.9 7.83 H
C 168.4 6.63 K 19.0 0.75 R 7.1 0.28 V (6) THD.
K
D 147.6 5.81 L 35.1 1.38 R 9.7 .38 T(2) DIA . MAX .
M L
E 114.3 4.50 M 44.5 1.75 T 11.2 0.44
N
F 82.6 3.25 N 123.8 4.88 U 32.0 1.25 P O T
P Y
Q
G 76.2 3.00 O 130.2 5.13 V 3/4-10 UNC MIN . U(4) DIA. MAX.
B
X A

44 CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES


VALVE BOLT KITS

WORKING
MODULAR ORDER LENGTH WEIGHT
STACK VALVE VALVE STACK(MM) INCH CODE TYPE (MM) INCH lbs. (kg)

V5M / VD03M DIRECTIONAL (25 .5) (0 .02)


VALVE ONLY BD03-100 BOLT 0 .05
NFPA D03 1 .00
CETOP 3
NG6 VALVE + (1) (40 .0) MODULAR BD03-250 BOLT (63 .8) (0 .04)
1 .57 STACK 2 .50 0 .08
KIT: VALVE + (1) (50 .0) MODULAR BD03-300 BOLT (76 .0) (0 .05) SOCKET HEAD
(4) 10-24NC 1 .96 STACK 3 .00 0 .13 CAP SCREW
FASTENERS
(4) #10 VALVE + (2) (40 .0) MODULAR BD03-4125 BOLT (104 .8) (0 .08)
LOCKWASHERS 1 .57 STACK 4 .125 0 .18
VALVE +(1) (40 .0) +(1) (50 .0) BD08-450 (114 .0) (0 .09)
BOLT
MODULAR 1 .57 1 .96 4 .50 0 .20

VALVE + (3) (40 .0) MODULAR BD03-575 BOLT (146 .0) (0 .10)
1 .57 STACK 5 .75 0 .23
BOLT
(0 .08) LENGTH
VALVE+ (2) (40 .0) MODULAR BD03-460 STUD (104 .8)
4 .125 0 .18
1 .57 STACK
VALVE + (3) (40 .0)MODULAR BD03-616 STUD (146 .0) (0 .10)
1 .57 STACK 5 .75 0 .23

V12M / VD0-5M DIRECTIONAL (44 .6) (0 .05)


NFPA D05 VALVE ONLY BD05-175 BOLT 0 .11
1 .75
CETOP 5
NG10 VALVE + (1) (55 .0) MODULAR BD05-400 BOLT (102 .0) (0 .10)
2 .17 STACK 4 .00 0 .24
KIT:
(4) 1/4-20NC VALVE + (2) (55 .0) MODULAR BD05-6125 BOLT (155 .6) (0 .20)
FASTENERS 2 .17 STACK 6 .125 0 .44
(4) 1/4” (0 .25)
VALVE + (3) (55 .0) MODULAR BD05-825 BOLT (209 .6)
LOCKWASHERS 2 .17 STACK 8 .25 0 .55

VALVE + (2) (55 .0) MODULAR BD05-667 STUD (155 .6) (0 .20)
2 .17 STACK 6 .125 0 .44
STUD NUT
VALVE + (3) (55 .0)MODULAR BD05-884 STUD (209 .6) (0 .25)
2 .17 STACK 8 .25 0 .55
V50M / VD08M DIRECTIONAL (70 .1) (0 .57)
DVS50M BD08-275 BOLT 1 .25
VALVE ONLY 2 .75
NFPA D08
CETOP 8 VALVE + (1) (88 .9) MODULAR BD08-625 BOLT (159 .4) (1 .02)
NG25 3 .44 STACK 6 .25 2 .25 EFFECTIVE
STUD
(6) 1/2-13NC VALVE + (1) (101 .6)MODULAR BD08-675 BOLT (172 .1) (1 .08) LENGTH STUD
FASTENERS 4 .00 STACK 6 .75 2 .40 Rc 39-45
(6) 1/2” HARDNESS
LOCKWASHERS VALVE + (2) (88 .9) MODULAR BD08-9625 BOLT (244 .5) (1 .70)
3 .44 STACK 9 .625 3 .75

VALVE +(1) (88 .9)+(1 )(101 .6) BD08-1020 BOLT (260 .0) (1 .81)
MODULAR 3 .44 4 .00 10 .25 4 .00

VALVE + (2)(101 .6)MODULAR BD08-1080 BOLT (273 .0) (1 .87)


4 .0 STACK 10 .75 4 .13

VALVE + (2) (88 .9) MODULAR BD08-1025 STUD (244 .5) (1 .70)
3 .44 STACK 9 .625 3 .75 DIRECTIONAL
CONTROL
(1 .81) VALVE
VALVE +(1) (88 .9) +(1 )(101 .6) BD08-1075 STUD (260 .0)
MODULAR 3 .44 4 .00 10 .25 4 .00 POLYSTAC EFFECTIVE
VALVE LENGTH
VALVE +(2)(101 .6)MODULAR BD08-1125 STUD (273 .0) (1 .87) POLYSTAC
4 .00 STACK 10 .75 4 .13 VALVE

V100M / VD10M DIRECTIONAL (1 .19) SUBPLATE/


(63 .8) MANIFOLD
NFPA D1 0 VALVE ONLY BD10-250 BOLT 2 .63
2 .50
CETOP 10
KIT: (6) 3/4-10NC
FASTENERS
(6) 3/4"
LOCKWASHERS
VALVE
F12M FLOW (57 .8) (0 .11)
NFPA 2F06 CONTROL B2F06-225 BOLT CONTINENTAL
0 .25 HYDRAULICS DIRECTIONAL CONTROL VALVES 45
2 .25
KIT:
(4) 5/16"-18NC
Directional control valves DIRECTIONAL CONTROL VALVES
PRODUCT OVERVIEW ISO 9001:2000 CERTIFIED

Specifications
• Mounting: Sub-plate or manifold mount in D03, D05, When reliability and Product Lineup power and 3 gallon tank size,
D08, and D10 configurations; conforming to NFPA and durability count....count on to 100 horse power, 330 gallon
ANSI/ISO Standards Pumps
Continental Hydraulics! tank, straight out of the catalog.
• PVR Vane Pumps, rugged duty
• Flow: Continental Hydraulics is a world • Custom Designed and larger
pumps for medium pressure
D03 – Up to 20 GPM D05 – Up to 35 GPM leading hydraulic components units to match your application,
D08 – Up to 150 GPM D10 – Up to 275 GPM
applications
manufacturer. Since 1955 we’ve exactly
been designing and manufacturing • PVX Vane Pumps, quiet pumps for
• Pressure: Up to 5,000 PSI higher pressure applications
hydraulic equipment to withstand
• Seals: Viton® • HPV Piston Pumps, efficient pumps Continental Hydraulics manufactured
the most demanding applications.
for higher pressure applications components are covered by a 3 year
• Fluids: Petroleum-base, mostphosphate esters, Continental Hydraulics is ISO
Features & Benefits warranty!
water based fluids (not more than 40% water) 9001:2000 Certified.
• High flow rates and low pressure drops reduce heat
generation and increase efficiency
and water glycol Valves
• Premium bore honing reduces crossport leakage Our Approach • D03/5/8/10 Directional Control How can we help you?
• Interchangeable spools for simplified field maintenance, Options & Accessories Continental Hydraulics welcomes Valves, for a variety of applications Contact your Continental
and eliminate the need to change valve body when • Solenoid, lever, air, soft shift and cam control operators • D03/5/8 Proportional Control Hydraulics representative for
the opportunity to work with
changing spools • Low watt power solutions to your toughest
you to help design your hydraulic Valves offer more control options,
• Below center-line mounting bolt position reduces body • Wide variety of electrical connections hydraulics problems. Whether it’s
distortion that causes sticky spools • Hazardous environment solenoids (dust and gas system from the ground up. Our from programmable On-board
amplifiers to panel and Euro card reducing your operating expenses,
• Two-pin plug-in or DIN connection coils allow for quick classifications) Application specialists and our
mounts. or increasing your production
replacement reducing down time • Wash down trained local support Distributors
capability, you can count on
• All valves with optional electric box include indicator • Anti-shock option can advise you of the most efficient, • Modular Stack Valves for controlling Continental Hydraulics!
lights and electrical transorb surge suppression for coil • Patented DeAccelatrol® motion control valve cost-effective components available flows and pressures in industrial
protection and increased • Wide variety of bolt and stud kits for mounting modular off the shelf, or work with you on and/or mobile applications
valve life stack valves custom designs to meet your needs.
• Sealed wet armature solenoids provide maximum • Spool indication switches • Cartridge Valves for controlling
protection against moisture, corrosion and dirt. • Double redundant monitoring packages and lockout valves flows and pressures in compact
Product Characteristics applications
Product Description Continental Hydraulic’s products
Continental Hydraulics PowrFlow Directional Control

In the event of a component are designed to provide maximum Power Units
Valves offer some of the highest flow and pressure ratings in or system failure, the double overall value. Reliability, durability, • Little Champ series for smaller and/
the industry today, making them the perfect choice whether redundant valve option and efficiency are designed in. Ease or economical applications
you are designing a new system or just simply trying to get shuts down the system in a of maintenance, quiet operation and
more out of your current system. Superior performance and controlled manner to help avoid • JIC and L-Shape series for larger
low operating costs are common
durability makes these Directional Control Valves a great damage and injury. industrial applications
design features.
investment. • Available from fractional horse
With 12 standard spools, numerous specialty spools and 7
functions, these directional control valves can be ordered to
meet the specific needs of your applications.

Precise bore honing and spool grinding results in less


cross-port leakage and less wasted energy. Spools also Continental Hydraulics
utilize U-groove machining making them more tolerant of valves are designed to use
interchangeable spools for
contaminants than v-groove designs resulting in less spool
simplified field maintenance.
hang-ups.

Controller options include solenoid, lever, air, soft shift and


cam operators.

CONTINENTAL HYDRAULICS DIRECTIONAL CONTROL VALVES Because Continental Hydraulics is continually improving its products, specifications and appearance are subject to change without notice.
PowerFlow™ D03
Directional Control Valves

5505 West 123rd Street • Savage, MN 55378-1299 • Ph: 952.895.6400 • Fax: 952.895.6444 • www.continentalhydraulics.com
Form No. 1004532 Rev. 6/08 © 2008 Continental Hydraulics. All rights reserved. Product specifications and appearance are subject to change without notice.

You might also like