TURBINE STARTUP CHECKS

COLTURBINAS 3600 RPM, MECHANICAL CONTROLS


Colombiana de
Turbinas

Customer Rating
Plant Type
Unit No. Date
Serial No. Recorded By
OEM

STARTUP:
Oil Pump Auto Starts Tested Yes No

Main Stop Valve Leakage rpm (Turning Gear)

Control Valve Leakage rpm (< 500rpm)

Oil Trip rpm (~3350 rpm, < 3600rpm)

Low Speed Stop rpm (3450 rpm)

Intercept Valve rpm (3660 - 3680 rpm)

High Speed Stop rpm (3860 rpm)

Low Vacuum Alarm In. Hg (25 In. Hg)

Trip In. Hg (19.5 In. Hg)

INITIAL PRESSURE LIMITER


100% CV Start Closing rpm (90% Rated Boiler Pressure)

No Load CV Position rpm (77% - 83% Rated Boiler Pressure)

AFTER > 3 HOURS AT 25% LOAD:


Backup Overspeed Trip rpm (3906 - 3942 rpm)

Trip Anticipator rpm (3900 - 3940 rpm)

Overspeed Trip (3960 - 3996 rpm)

1st rpm

2nd rpm

3rd rpm

Comments: