Neuropack S1

MEB-9400
EMG/NCV/EP
Measuring System
The feature rich Nihon Available in a 2 or 4 channel amplifier,
the Neuropack is offered in a desktop

Kohden Neuropack or laptop configuration for portability


without compromise.
MEB-9400 offers
efficient EMG, NCV Our compact, low noise
and EP exams with amplifier insures clean
waveforms easily and quickly.
innovative time saving
Basic exam software including Quick Examination
technology. EMG, NCS, SEP, ABR and VEP Innovative hardware and software shorten
is standard with the MEB-9400. the examination time.

Tailor the Quick menu to


your examination workflow
to reduce testing time. Quick
EMG and NCS programs Low Noise, User-Friendly
provide the fastest examination Compact Amplifier Control Panel
possible. The MEB-9400 value
The low noise amplifier speeds up the The easy-to-use control panel allows for smooth
is further enhanced with our examination by giving you clean waveforms and efficient examinations. You can change
gold standard 32 channel easily and quickly. Choose from our 2 the electric stimulation duration and rate with
or 4 channel amplifier (JB-942 or JB-944). a simple one-touch operation. The side/set key
EEG option for the most flexible and muscle/test keys allow quicker EMG and
multi-modality configuration NCS examinations.
Impedance Needle Electrode
on the market today. Check Holder

Select the measurement Reset Key


side in EMG Set the stimulation
and NCS program intensity to zero

Select the electric


Cable stimulation
Hook duration and rate
NeuroNavi Flexible Software Innovation
NeuroNavi® shows Workflow Solutions
examination information and NeuroWorkbench ® is the core integrator of the
electrode and stimulation Nihon Kohden neurology product portfolio.
positions for NCS and other This common interface allows for examination
scheduling, protocol administration and
exams. This guide can be data management that improve workflow.
referenced on the screen at NeuroWorkbench provides HIPAA Compliant
any time. access to clinical data and records with
passwords and three levels of administrative rights,
NeuroWorkbench – Scheduler as well as audit trails. A flexible NeuroWorkbench
option includes an HL7 interface. The
NeuroReport NeuroWorkbench SQL Database integrates all
of the Nihon Kohden neurology devices to
provide a complete database across all neuro-
A customized report can be
diagnostic and -monitoring modalities.
generated with the click of
a button using our proprietary Menu Window for an MEB
NeuroReport™ software. Examination
Included in NeuroReport are several Open an MEB examination screen using the
selectable layouts which can display your examination protocol menu.
NeuroWorkbench – Patient List
facility’s logo, test results with highlighted
abnormals, waveforms and a powerful
Menu Tabs
auto-text summary. Saved within the
database, the report can automatically be Up to eight category tabs with 10 programs
signed electronically and converted to a per tab for a total of 80 preset examination
PDF, protecting the electronic record while programs.
keeping it universally viewable.
Data Manager Tab
• Database files
• Copy, move and delete file
• Patient database with search and
NeuroWorkbench – Protocol Tab
query function

Workbench Tab
• Scheduler
• Remote access
• Review patient files
Nerve Conduction Study Electromyography (EMG)

Hardware Options
• KD-019 or NIH-9000 Cart
• KH-001 Arm
• DR-531-14 Headphones
• LS-102 LED Goggles
• JE-921 EEG Amplifier
The NCS program lets you perform MCS, SCS and F-Wave in one Routine EMG Program Quick Display EMG Playback/EMG Player • LS-120 Photic Stimulator
program. Any number and combination of examinations can The routine EMG program utilizes auto You can easily switch between four You can also easily review any acquired
be created in your own custom routine protocol by selecting MUP detection and classification, and real measurement modes that you can define waveform with sound after measurement
time turns/amp analysis. A functional freely—for example for insertion activity, by clicking the EMG player button. This tool
nerve, side and exam. You can change the examination by just
and sophisticated findings screen meets motor unit detection or turn/amplitude lets you play back EMG files with sound on
clicking the item in the list box, or by clicking a button on the various needs in clinical use by easy analysis or interference—by pressing a a review station for presentations and Software Options
dedicated operation panel of the Neuropack. and smooth operation. button at the bottom of the screen or on lectures.
the control panel. • Display up to 600 sec of EMG with sound • QP-951 Quantitative EMG
Motor NCS/Sensory Repetitive Stim Interference • Sweep speed, sensitivity, and filter Software
MUP Analysis settings can be changed afterwards;
• When measuring with the MEB there is • The amplitude of each sequence is Turns/amp measurement is automatically
a great function for teaching purposes
• QP-952 Single Fiber and
no need to manually pick the stimulation displayed as a bar graph on the performed. The measurement result MUP waveforms are automatically detected
site before starting the recording. same screen. You can see the summary is displayed at every one second on and classified into groups of similar
• Compressed/cascaded waveform Macro EMG Software
display
The software does this automatically of the repetitive stimulation study the turns-interval histogram, turns/amp shaped MUPs. MUP measurement result • QP-954 Autonomic Nervous
for you and, if necessary, it can be at a glance. The waveform of each histogram and turns/amp graph. (duration, amplitude, phase, turns and firing System Testing Software
easily changed. sequence can be displayed by clicking The turns/amp normative data of several rate) are shown next to the waveforms
• Side comparisons and combined the corresponding bar graph. muscles are installed as default settings or in a dedicated summary screen. • QP-930 EMG Playback
motor and sensory tests can be shown • Up to 12 sequences of stimulation and its normative area is displayed in The averaged MUP of the same MUP groups • QP-219 EMG Review Software
in one waveform screen and also patterns can be set for one automatic the turns/amp histogram. You can easily are calculated and displayed with the
have their own dedicated evaluation measurement (automatic sequence recognize whether or not the measuring numeric data.
• NK-NWB NeuroWorkbench
tables. function). waveforms are in the normative range. Server Software
• Normative data are shown on the • Stimulation can be done with either • NK-NWB HL7 Interface
same screen. high or low frequency or combined
Software
• The superimposed waveform in real in the same protocol.
time is shown at the same time, so you
• NK-EEGAddOn
can easily compare the amplitudes
of all stimulation sites and thus judge
the quality of your stimulation.
Nerve Conduction Study Evoked Potentials

The NCS program lets you perform MCS, SCS and F-Wave in one Standard SEP examination Standard AEP examination
program. Any number and combination of examinations can protocols are: protocols are:
be created in your own custom routine protocol by selecting • SEP (somatosensory evoked potential) • ABR (auditory brainstem response)
nerve, side and exam. You can change the examination by just • SSEP (short-latency SEP) • MLR (middle latency response)
• ECG-SSEP (ECG-triggered SSEP) • SVR (slow vertex response)
clicking the item in the list box, or by clicking a button on the • ESCP (evoked spinal cord potential) • EcochG (electrocochleogram)
dedicated operation panel of the Neuropack.
Standard VEP examination Three types of auditory
Motor NCS/Sensory Repetitive Stim
protocols are: stimulation
• When measuring with the MEB there is • The amplitude of each sequence is
• Pattern-VEP Click, tone burst, and tone pip stimulation
no need to manually pick the stimulation displayed as a bar graph on the
• Goggle-VEP are available.
site before starting the recording. same screen. You can see the summary
• Flash-VEP
The software does this automatically of the repetitive stimulation study
• ERG (electroretinogram) ABR auto marking
for you and, if necessary, it can be at a glance. The waveform of each
• EOG (electrooculogram)
easily changed. sequence can be displayed by clicking In the ABR protocol, automatic waveform
• Side comparisons and combined the corresponding bar graph. marking allows time-saving measurement
motor and sensory tests can be shown • Up to 12 sequences of stimulation
Flexible pattern stimulations of latency, amplitude, and interval.
in one waveform screen and also patterns can be set for one automatic VEP protocol requires a VEP monitor.
have their own dedicated evaluation measurement (automatic sequence Pattern reversal stimulation can Side comparison
tables. function). be selected from full, half, and quarter
Split screen display allows for side
visual field. 4 to 128 horizontal divisions
• Normative data are shown on the • Stimulation can be done with either comparisons at a glance.
can be selected for patterns.
same screen. high or low frequency or combined
• The superimposed waveform in real in the same protocol.
time is shown at the same time, so you
can easily compare the amplitudes
of all stimulation sites and thus judge
the quality of your stimulation.
Specifications
Amplifier Dimensions and Weight
Number of channels: Main unit:
JB-942: 2, JB-944: 4 350 (W) x 62 (H) x 395 (D) mm, 3.0 kg
PC Unit depends on the model selected
Input impedance:
>200 MΩ (differential mode), ≥ 1000 MΩ JB-942 amplifier:
(common mode) 217 (W) x 174 (H) x 34 (D) mm, .71 kg
Noise: JB-944 amplifier:
<0.6 µVrms or less at 1 Hz to 10 kHz 217 (W) x 174 (H) x 34 (D) mm, .74 kg
with input shorted
Sensitivity:
1, 2, 5, 10, 20, 50, 100, 200, 500 µV/div, Power Requirements
1, 2, 5, 10 mV/div ±5%
Line voltage:
High cut filter:
100 to 240 V AC ±10% Line
10, 20, 50, 100, 200, 500 Hz, 1, 1.5, 2, 3, 5,
10, 20 kHz at 12 dB/oct (±20%) Frequency:
50/60 Hz
AC interference notch filter:
50 or 60 Hz (rejection ratio: <1/2-0) Power input:
75 VA (DC-110B)
Amplitude calibration:
1, 10, 100 µV, 1, 10mV (within ±5%)
Skin-electrode contact
impedance check: Environment
2, 5, 10, 20 kΩ indication (within ±20%)
Operating temperature:
Low cut filter: 10 to 35°C (50 to 95°F)
0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5,
Operating humidity:
10, 20, 50, 100, 200, 500 Hz, 1, 2, 3 kHz
30% to 80%
6 dB/oct (±20%)
Operating atmospheric pressure:
70 to 106 kPA
Storage temperature:
-20 to +65°C (-4 to 149°F)
Storage humidity:
20 to 80%
Storage atmospheric pressure:
70 to 106 kPa

us.nihonkohden.com

NMLB 047 [G]-CO-0467 NeuroReport is a trademark and, NeuroNavi and NeuroWorkbench


are registered trademarks of Nihon Kohden Corporation.